Used Gas Chromatography Mass Spectrometry
Filter
Showing 1–30 of 32 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890 Plus GC + 5973 MSD |
| Configuration | GC-MS System for VOC/SVOC Quantification per GB/T 23986.2–2023 |
| Condition | Professionally Refurbished & Functionally Verified |
| Compliance | Fully Compatible with ASTM D6886, ISO 11890-2, and US EPA Method 8260D workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890N + 5973N |
| Price | USD 22,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7200 |
| Price Range | USD 135,000 – 205,000 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Configuration | Gas Chromatography–Triple Quadrupole Mass Spectrometry (GC-QQQ) |
| Model | 7890A GC System + 7000B MS/MS |
| Condition | Certified Pre-Owned, Fully Refurbished and Performance-Verified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A + 5975C |
| Ion Source Temp Range | 100–300 °C (independently controlled) |
| Electron Energy | 10–200 eV |
| Sensitivity (EI) | ≥185:1 S/N for 1 pg OFN (m/z 272, full scan) |
| Sensitivity (NCI) | ≥300:1 S/N for 10 fg OFN (m/z 272, SIM) |
| Mass Range | 1.5–1050 amu |
| Resolution | Unit mass |
| Scan Speed | ≥10,000 amu/sec |
| Mass Axis Stability | ≤0.1 amu/48 h |
| Detector | Off-axis electron multiplier |
| Quadrupole | All-metal molybdenum, pre-filtered, permanently contamination-resistant |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Software | MSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A + 7000A/B |
| Configuration | Gas Chromatography–Triple Quadrupole Mass Spectrometry (GC–MS/MS) |
| Ion Source | Electron Ionization (EI) |
| Collision Gas | Nitrogen/He Mix |
| Detector Type | Triple Quadrupole (QqQ) |
| Regulatory Compliance Support | ASTM D5845, EPA Method 8270/1613/1631, USP <621>, FDA 21 CFR Part 11 (Software-Enabled) |
| Data System | MassHunter Workstation (vB.08.x or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A-5975C |
| Mass Range | 1–1050 u |
| Scan Rate | 12,500 u/s |
| Sensitivity | 20 pg/μL octafluoronaphthalene (OFN), S/N ≥ 10:1 at m/z 272 |
| Ion Source Temperature | Up to 300 °C |
| Quadrupole | Heated dual-curved rod assembly |
| Carrier Gas Compatibility | Helium, Hydrogen, Nitrogen |
| Software | MSD ChemStation with Deconvolution Reporting Software (DRS), Retention Time Locking (RTL), Capillary Flow Technology support |
| Warranty | 90-day parts and labor |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Origin | Imported |
| Model | 7890B + 7010B |
| Price | USD 95,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B + 7000C/D |
| Configuration | GC with ALS G7693A, Heated EI Extractor Ion Source, Gold-Plated Quadrupole Mass Filters, HED-EM Detector, Dual Turbo Molecular Pumping System, MassHunter Software Suite |
| Compliance | ASTM D5845, EPA Methods 8270/1613/1631, USP <621>, ISO/IEC 17025 |
| Service History | Fully Refurbished & Performance-Verified per Agilent OEM Standards |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977B |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Vacuum System | High-Performance Turbomolecular Pump |
| Ion Source | Dual-Filament EI Source, Inert (Non-Coated, Non-Stainless Steel) |
| Mass Analyzer | Gold-Plated Quartz Quadrupole with Turner-Kruge Lenses |
| Mass Range | 1.6–1050 u (0.1 u increments) |
| Resolution | Unit Mass Resolution |
| Mass Stability | ≤0.10 u / 48 h |
| Full-Scan Sensitivity (EI) | ≥400:1 S/N for 1 pg OFN (m/z 272, 50–300 u scan) |
| SIM Sensitivity (EI) | ≥10:1 S/N for 20 fg OFN |
| Max Scan Rate | 12,500 u/s (1 ms dwell in SIM) |
| Dynamic Range | 10⁶ |
| SIM Capacity | 100 groups, up to 60 ions/group |
| GC Oven Temp Range | 4 °C above ambient to 450 °C |
| Max Ramp Rate | 120 °C/min |
| Temperature Stability | <0.01 °C per 1 °C ambient change |
| Programmable Temperature Zones | ≥6 heated zones (including inlet, detector, transfer line), all independently controlled up to 400 °C |
| EPC Pressure Control Accuracy | ±0.001 psi |
| Split/Splitless Inlet | Up to 7500:1 split ratio, 0–1250 mL/min H₂/He flow range |
| Auto-sampler | 16-position (standard), optional 150-position tray |
| Detectors Included | FID (detection limit <1.8 pg C/s), micro-ECD (<6 fg/mL lindane), NPD (<0.4 pg N/s, <0.2 pg P/s) |
| Compliance | Fully compatible with EPA Methods (e.g., 502.2, 524.4, 8260, 8270), USP <621>, ASTM D5845, and GLP/GMP data integrity requirements per FDA 21 CFR Part 11 |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890B + 5977A |
| Configuration | Gas Chromatography–Mass Spectrometry (GC-MS) System |
| Ion Source | High Efficiency Source (HES) with Electron Ionization (EI) |
| Detection Limit (IDL) | 1.5 fg (as reported for chlorobenzene, per Agilent specification) |
| Sensitivity Gain | Up to 10× vs. prior-generation single quadrupole MSDs |
| Pump Option | IDP-3 Dry Scroll Vacuum Pump (optional, low-noise, oil-free operation) |
| Software Platform | Agilent MassHunter Workstation (v10.x or later, license transferable per Agilent policy) |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B GC / 5977A MSD |
| Configuration | G4513A + G4514A (7693A) Autosamplers (150-position tray), Edwards Turbo Pump, MassHunter Software Suite |
| Warranty | 90-day comprehensive hardware warranty |
| Condition | Refurbished & fully validated by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 8860-5977B |
| Price Range | USD 68,000 – 136,000 |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | 450-GC+300MS |
| Configuration | GC-MS/MS (Triple Quadrupole) |
| Instrument Condition | Refurbished & Fully Qualified Used System |
| Regulatory Compliance | Designed to meet ASTM D5845, EPA Method 8270/8260, and ISO 17025 laboratory requirements |
| Software Platform | Bruker Compass DataAnalysis 5.4+ with QuantAnalysis and TargetScreener modules |
| Brand | Bruker |
|---|---|
| Origin | USA |
| Model | GC456-SCION TQ |
| Configuration | Used, Refurbished & Fully Qualified Triple Quadrupole GC-MS/MS System |
| Compliance | Meets ASTM D5845, EPA Method 8270/8260, and ISO 17025-aligned operational readiness standards |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-800D |
| Configuration | Magnetic Sector GC-MS System for Dioxin Analysis |
| Detector Type | Photomultiplier Tube (PMT) |
| Software | Diok Suite for Dioxin/Furan Quantitation |
| Vacuum System | Oil-diffusion or Turbo-molecular Pumping (Typical for JMS-800D Era) |
| Mass Resolution | >10,000 (10% Valley) at m/z 320 |
| Mass Range | Up to m/z 1000 |
| Ion Source | Electron Ionization (EI), Dual-Channel Design |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 Plus |
| Configuration | GC-2010 Plus GC, TD-20 Thermal Desorber, AOC-20s 100-position Autosampler Tray, AOC-20i Autosampler, LabSolutions Software Workstation, Dual-inlet Turbo Molecular Pump (≥360 L/s), Vacuum System |
| Warranty | 90 days post-installation verification |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 Plus |
| Instrument Type | Benchtop GC-MS |
| Configuration | Single Quadrupole |
| Detection Mode | Electron Ionization (EI) |
| Mass Range | 1.5–1099 u |
| Scan Speed | Up to 10,000 u/sec |
| Interface Temperature | Up to 300 °C |
| Ion Source | Dual-mode (EI/CI optional with upgrade) |
| Vacuum System | Turbomolecular pump + backing pump |
| Compliance | Fully compatible with ASTM D5845, EPA Method 8270/8260, USP <621>, ISO 17025 workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | QP2010 Ultra |
| Price | USD 27,500 (approx.) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | QP2010 |
| Configuration | VOC/SVOC Analysis-Optimized (per GB/T 23986.2–2023) |
| Regulatory Alignment | Compliant with ISO 11843, ASTM D6886, and US EPA Method TO-17 for VOC quantification |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010Plus |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets Original Shimadzu Factory Specifications |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010SE |
| Configuration | GC-2010 Plus GC + QP2010SE MS + Auto-sampler (Headspace or Liquid, selectable) + Vacuum Pump + LabSolutions Workstation PC + Essential Tubing/Cabling |
| Warranty | 90-day comprehensive hardware warranty |
| Condition | Fully tested and verified operational status |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8040 |
| Configuration | Refurbished Unit with Full Functional Validation |
| Compliance | Meets Original Shimadzu Factory Specifications for GC-MS/MS Operation |
| Software | Includes Licensed GCMSsolution Ver. 5.x (with Smart MRM, ASSP, and Scan/MRM Simultaneous Acquisition Modules) |
| Instrument Status | Fully Recertified with Performance Verification Report (PVR) per ISO/IEC 17025 Traceable Protocols |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8050 |
| Year of Manufacture | 2018 |
| Condition | Refurbished & Certified Pre-Owned |
| Configuration | Complete Benchtop System with GC, TQMS, Autosampler, and GCMS Insight Software |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2020 NX |
| Configuration | Single Quadrupole GC-MS |
| Vacuum System | Dual-stage Turbo Molecular Pump (High-Capacity) |
| Ionization Modes | Electron Impact (EI) and Chemical Ionization (CI) with Quick-CI™ |
| Gas Control | Advanced Flow Control (AFC) with Constant Linear Velocity (CLV) mode |
| Scan Speed | Up to 20,000 u/sec with ASSP™ (Advanced Scanning Speed Protocol) |
| Software Platform | LabSolutions Insight v2.x with GCMS Insight, Smart SIM, AART, and Retention Index–Enabled Libraries |
| Compliance Support | ASTM D5847, ISO 17025 workflows, USP <621>, FDA 21 CFR Part 11 audit trail ready (configuration-dependent) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GCMS-QP2010 |
| Price | ¥150,000 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2020 |
| GC Unit | GC-2010 |
| Oven Temperature Range | 2 °C above ambient to 450 °C |
| Column Oven Ramp Rate | Up to 120 °C/min |
| Injector Temperature Range | Ambient to 450 °C |
| AFC Pressure Range | 0–1035 kPa |
| Retention Time Reproducibility | <0.0008 min |
| Peak Area RSD | <1% |
| MS Interface Temperature | 50–350 °C |
| Ion Source | Front-access, maintenance-friendly EI/CI/NCI source with dual filaments |
| Ionization Energy | 10–200 eV |
| Filament Current | 5–250 µA |
| Mass Analyzer | All-metal quadrupole with pre-quadrupole |
| m/z Range | 1.5–1090 |
| Optional DI Probe | Ambient to 500 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | DFS High-Resolution Magnetic Sector GC/MS |
| Configuration | Dual-Trace 1300 GC + TriPlus RSH Autosampler |
| Detector | Dual-mode Faraday Cup / Secondary Electron Multiplier (SEM) |
| Mass Resolution | Up to 10,000–100,000 (M/ΔM, 10% valley) |
| Mass Accuracy | < 1 ppm (with internal lock mass) |
| Ion Source | Removable, maintenance-optimized EI/CI source |
| Vacuum System | Pneumatic valve–locked ion box |
| Compliance | Fully compatible with EPA Methods 1613, 23, 8270, USP <1225>, ISO/IEC 17025, and GLP/GMP audit trails (when configured with Thermo Xcalibur 3.1+ and 21 CFR Part 11–enabled software modules) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISQ LT |
| Price Range | USD 13,500 – 40,500 |
