Used Instruments
Filter
Showing 511–540 of 645 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Corona Ultra CAD |
| Detection Principle | Charged Aerosol Detection (CAD) |
| Power Supply | 100–240 V AC, 100 VA |
| Serial Number | DU-0136 |
| Age | 3–5 years |
| Warranty | 6 months |
| Compliance | Designed for GLP/GMP-compliant laboratories |
| Software Compatibility | Compatible with Chromeleon CDS (v7.2+), Empower (v3+), and other industry-standard chromatography data systems |
| Regulatory Alignment | Supports 21 CFR Part 11 audit trail requirements when paired with validated CDS configurations |
| Sample Compatibility | Non-volatile and semi-volatile analytes across small molecules to macromolecules |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Dionex ICS-6000 |
| Operating Pressure | Up to 5000 psi (34.5 MPa) |
| Column Compatibility | Capillary and Analytical Format (e.g., 4 µm particle size columns) |
| Detector Options | DC Conductivity Detector (dual-zone temperature control), ED Electrochemical Detector, VWD/PDA UV-Vis Detector |
| Software | Dionex Chromeleon Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | ~10 years (refurbished & validated) |
| Brand | Thermo Fisher Scientific Dionex |
|---|---|
| Origin | USA |
| Instrument Model | ICS-900 |
| Year of Manufacture / Service Life | ~2019–2020 (3–4 years operational use) |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Fully compliant with ASTM D4327, ISO 14911, USP <645>, and EPA Methods 300.0, 300.1, 310.1 |
| Software Platform | Chromeleon 7.2.10 or later (licensed, validated for GLP/GMP environments) |
| Detector Type | Digital conductivity detector with temperature-compensated cell |
| Pump System | Dual-piston isocratic pump (flow range: 0.001–5.000 mL/min, pressure rating: up to 35 MPa) |
| Suppressor Compatibility | MMS™ 300 (DCR mode) and ERS™ 500 series electrolytic suppressors |
| Fluidic Path | All-PEEK, metal-free, chemical-resistant (pH 0–14, compatible with organic modifiers up to 40% ACN/MeOH) |
| Data Interface | USB 2.0 (supports audit trail, electronic signatures per 21 CFR Part 11) |
| Certification Status | Delivered with full IQ/OQ documentation (performed by SpectraLab Scientific prior to resale) |
| Automation Ready | Compatible with AS-DV autosampler (optional, not included unless specified) |
| Brand | Thermo Fisher Scientific (formerly Dionex) |
|---|---|
| Origin | USA |
| Model | ICS-2100 |
| Instrument Type | Ion Chromatograph |
| Configuration | RFIC-EG + RFIC-ESP Enabled |
| Column Options | 2 mm & 4 mm ID |
| Detector | Digital Conductivity Detector with Temperature Compensation |
| Pump | Dual-piston High-Pressure Isocratic Pump (RFIC-EG Compatible) |
| Flow Rate Precision | ≤0.1% RSD |
| Conductivity Cell | Digital Thermostatted, Low-Dead-Volume |
| Software | Chromeleon 7.2 or Later (FDA 21 CFR Part 11 Compliant) |
| Operating Environment | Lab-grade Cleanroom-Tested |
| Reconditioning Standard | SpectraLab Certified Refurbishment Protocol (ASTM E2500-Aligned) |
| Warranty | 6 Months Limited Hardware Warranty |
| Service History | <4 Years Operational Use |
| Compliance | ISO/IEC 17025 Traceable Performance Verification |
| Connectivity | USB 2.0, Ethernet, Digital I/O |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quanta 250 |
| Instrument Age | 5 Years |
| Vacuum Modes | High Vacuum, Low Vacuum, Environmental SEM (ESEM) Mode |
| Max Chamber Pressure | 2600 Pa |
| Accelerating Voltage Range | 200 V – 30 kV (continuously adjustable) |
| Stage Travel (Quanta 250) | X = Y = 50 mm |
| SE Resolution | 3.0 nm @ 30 kV (HV), 8 nm @ 3 kV (HV), 7 nm @ 3 kV (HV deceleration mode, optional), 3.0 nm @ 30 kV (LV), 10 nm @ 3 kV (LV), 3.0 nm @ 30 kV (ESEM) |
| BSE Resolution | 4.0 nm @ 30 kV |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Surveyor MSQ |
| Mass Analyzer Type | Single Quadrupole |
| Mass Range | 17–2000 m/z |
| Scan Speed | Up to 12,000 amu/sec |
| Ionization Modes | ESI and APCI (dual-source, polarity-switchable) |
| Flow Rate Compatibility | ESI 10 μL/min–2 mL/min |
| Source Temperature | Ambient to 650 °C |
| Nebulizing Gas | Nitrogen, 12 L/min |
| Detector | Ion Bright™ electron multiplier |
| Warranty | 6 months |
| Operational Age | 4–7 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | DSQ |
| Instrument Type | Quadrupole GC-MS System |
| Year of Manufacture / Service Life | 2019–2020 (4 years operational use) |
| Warranty | 6 months limited hardware warranty |
| Mass Range | m/z 10–1000 |
| Operating Temperature Range | 30–300 °C |
| Detection Limit | Low ppm (typical for EI full-scan mode) |
| Vacuum Lock Feature | Yes |
| Ion Source | Dual-mode (EI/CI) with curved lens optics |
| Scan Modes | Simultaneous Full-Scan + Selected Ion Monitoring (SIM) |
| CI Capability | Pulse Positive/Negative Chemical Ionization (PPINCI) option available |
| Included Components | Trace GC Ultra, DSQ MS detector, CTC Combi PAL autosampler, dedicated acquisition PC with Xcalibur software, installation cabling and consumables |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Trace DSQ |
| Mass Range | 1–1050 amu |
| Mass Stability | 0.1 amu/12 hr |
| Sensitivity (EI Full Scan) | 1 pg Octafluoronaphthalene, S/N ≥ 50:1 |
| Vacuum System | Turbo-molecular Pump Options (70 L/s, 250 L/s, or dual 200 L/s) |
| Ion Source | Dual-mode Electron Ionization (EI) / Chemical Ionization (CI) with Electronic Reaction Gas Control |
| Quadrupole | Molybdenum Rods with Curved Pre-filter Quadrupole |
| GC Oven Max Temp | 450 °C |
| GC Temperature Program | 7 ramp stages, 8 setpoints, 0.1–120 °C/min |
| Usage Duration | 6–8 years |
| Warranty | 6 months |
| Condition | Refurbished & Performance-Verified |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Trace GC 2000 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Dimensions (H×W×D) | 444 × 648 × 558 mm |
| Column Oven Temperature Range | Ambient + x°C to 450°C (optional LN₂ cooling to –99°C) |
| Ramp Rate | 0.1–120 °C/min (7-stage, 8-step programming) |
| Cool-down Time | 250 s (450 °C → 50 °C) |
| Heating Time | 390 s (50 °C → 450 °C) |
| Power Supply | 220/230 V ±10%, 50/60 Hz, 16 A |
| Max Power Consumption | 2700 W |
| Avg Power Consumption | 650 W |
| Sample Introduction | Split/Splitless (S/SL), Programmable Temperature Vaporizer (PTV), Cold On-Column (COC), PTV, HeadSpace, Purge & Trap, Thermal Desorption |
| Detectors Supported | FID, TCD, ECD, NPD, FPD, PID, PDD, Full Line of Thermo Scientific MS Detectors |
| Autosamplers | AS2000, TriPlus AS |
| Electronic Pressure & Flow Control (EPC) | Yes |
| Column Evaluation & Leak Detection | Automated self-test and column performance assessment |
| Detector Simultaneity | Up to 3 detectors operational concurrently with detector switching/sequencing capability |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE Ultra with FID & NPD |
| Usage Duration | 4–5 Years |
| Warranty Period | 6 Months |
| Product Category | Gas Chromatography System |
| Detector Configuration | Dual-detector (FID + NPD) |
| Autosampler | AS2000 |
| Condition | Refurbished & Fully Tested |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Trace GC Ultra |
| Usage Duration | 3–4 Years |
| Warranty | 6 Months |
| Key Components | Electron Capture Detector (ECD), Programmable Temperature Vaporizing (PTV) Injector, Thermo Scientific TriPlus RSH Autosampler |
| Detection Options | Flame Ionization Detector (FID), Flame Photometric Detector (FPD) |
| Compliance | Fully Tested & Certified per ISO/IEC 17025 Pre-Delivery Protocol |
| Software | Chromeleon CDS v7.3 or Later (FDA 21 CFR Part 11 Ready) |
| Configuration | Dual-channel architecture with independent oven zones, pressure/flow control, and detector signal routing |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TriPlus AS |
| Product Category | Chromatography |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| Instrument Model | TriPlus AS |
| Instrument Age | 4 years |
| Brand | Thermo Fisher |
|---|---|
| Brand | Waters |
| Origin | Canada |
| Model | TSP UV-150 / FI-2000, Waters UV-486 / Pump 510 |
| Usage Duration | 2–3 years |
| Warranty | None |
| Category | Used Liquid Chromatograph Components |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | TSP 100 & TSP 200 |
| Product Category | Chromatography |
| Usage Duration | 3–4 years |
| Warranty | Not Applicable |
| Condition | Factory-Refurbished and Fully Tested |
| Regulatory Compliance | Designed to meet legacy ASTM D4790 and ISO 13877 compatibility requirements for HPLC pump performance validation |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | P100 |
| Product Category | Chromatography |
| Operational Age | 5–7 Years |
| Warranty | 6 Months |
| Condition | Refurbished & Fully Tested |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Model | UV100 |
| Product Category | Chromatography Detector |
| Usage Duration | 4–5 years |
| Warranty | 6 months |
| Condition | Refurbished & Fully Tested |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSQ Quantiva |
| Price Range | USD 68,000 – 136,000 (FOB) |
| Product Category | Mass Spectrometer |
| Operational Age | 1–2 years |
| Warranty | 12 months |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | TSQ Quantum Access MAX |
| Mass Range | m/z 10–3000 |
| Resolution | ≥10,000 (FWHM) |
| H-SRM Dwell Time | <2 ms |
| Polarity Switching Time | <25 ms |
| Scan Speed | 5000 u/sec (full range) |
| Mass Stability | ±0.050 amu/24 h |
| Sensitivity (ESI/APCI) | 1 pg reserpine, S/N >200:1 (peak-to-peak) |
| Ion Source | H-ESI II & APCI |
| Vacuum System | Three-stage oil-free turbomolecular pumps (400 L/sec in Q2 region) |
| Detection | ±15 kV post-acceleration, 90° electron multiplier |
| Software | LC Quan 2.5, QED-MS/MS™, RER™, real-time isotope correlation, dynamic exclusion, >700-compound LC/MS/MS spectral library |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Model | TSQ Quantum Access |
| Mass Analyzer Configuration | Triple Quadrupole |
| Detection Principle | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) coupled with tandem mass spectrometry (MS/MS) |
| Typical Service Life | 6–8 years |
| Warranty | 6 months |
| Regulatory Compliance Context | Designed for GLP/GMP-aligned workflows |
| Software Platform | Xcalibur (v2.2 or later) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | TSQ Quantum |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Configuration | Integrated with TRACE GC Ultra and TriPlus 100 Autosampler |
| Operational Age | 7 years |
| Vacuum System | Included |
| Software | Pre-installed on dedicated PC (monitor excluded) |
| Warranty | 90-day limited hardware warranty |
| Compliance | Designed to meet ASTM D5845, EPA Method 8270/8260, ISO 17025-aligned operation |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | TRACE GC Ultra + TSQ Quantum GC/XLS/ULTRA |
| Configuration | Used, Fully Functional, Pre-Owned |
| Compliance | Meets Original Factory Specifications (as verified per pre-delivery QC checklist) |
| Service History | Full maintenance log available upon request |
| Calibration Status | Requires user-site requalification per ISO/IEC 17025 or GLP protocols |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TSQ Quantum XLS |
| Product Category | Mass Spectrometer |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Mass Range | 1.2–3000 u |
| Ion Source | DuraBrite IRIS |
| Collision Cell | 90° curved, zero-crosstalk |
| Detection Mode | SRM, H-SRM, PPINICI, QED-MS/MS |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready |
| Data System | QuanLab Forms, EZ-Method import via Excel |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | U3000 |
| Instrument Age | 6–8 years |
| Warranty | 1 year |
| Category | Liquid Chromatography System |
| Import Status | Imported |
| Distributor Type | Authorized Reseller |
| Price Range | USD 9,200 – 13,000 (FOB) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 |
| Instrument Type | Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 620 bar |
| UV Detector Wavelength Range | 190–900 nm |
| UV Noise | < ±2.5 µAU |
| UV Drift | < 0.1 mAU/h |
| Fluorescence Excitation/Emission Range | 200–900 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Autosampler Carryover | < 0.005% |
| Injection Cycle Time | 15 s |
| Column Oven Temperature Range | 5–85 °C |
| Temperature Stability | < ±0.1 °C |
| Solvent Channels | 6 |
| Degasser | Integrated Online Vacuum Degasser |
| Pump Configuration | Dual Triple-Quaternary Gradient System |
| Software | Chromeleon CDS (7.x or later) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vanquish Horizon |
| Product Category | Chromatography |
| Operational Age | 4 years |
| Warranty | 6 months |
| Pump Pressure Rating | 1500 bar (22,000 psi) |
| Maximum Flow Rate | 5 mL/min |
| Sample Capacity | Up to 8832 samples via 23 microplates |
| Detector Technology | LightPipe-enabled Diode Array Detection (DAD) |
| Temperature Control | Dual-mode column oven with active pre-heating |
| System Architecture | Integrated, fully bio-inert UHPLC platform |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | Vanquish VC-P21-A-01 |
| Category | Liquid Chromatograph (UHPLC) |
| Pump Type | Quaternary Solvent Manager |
| Maximum Pressure | 1500 bar |
| Flow Rate Range | 0.001–5.000 mL/min |
| Solvent Channels | 6 (2×3 configuration) |
| Column Oven Temperature Range | 5–120 °C |
| Detector | Diode Array Detector (DAD) with LightPipe™ Technology |
| Software | Dionex Chromeleon CDS v7.3 or later |
| Compliance | FDA 21 CFR Part 11 ready, GLP/GMP-supportive audit trail, ASTM D7941, ISO 17025 applicable |
| Warranty | 12 months limited hardware warranty |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | Canada |
| Model | Accela |
| Pressure Rating | Up to 15,000 psi |
| Pump Delay Volume | 65 µL |
| Detector | Accela PDA Detector (LightPipe™ technology) |
| Column Compatibility | Sub-2 µm particles |
| System Age | 2–3 years |
| Warranty | 6 months |
| Compliance | Designed for ASTM D4790, USP <621>, ISO 17025-aligned operation |
| Software Platform | Thermo Scientific Chromeleon CDS v7.x |
| Brand | Thermo Fisher |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AS-AP |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Service Life | 4–5 years |
| Warranty | 6 months |
| Brand | Thermo Scientific Dionex |
|---|---|
| Origin | USA |
| Model | ICS-4000 |
| Configuration | Capillary High-Performance Ion Chromatography (HPIC) System |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Detection Options | Conductivity Detector (CD), Charge Detector (QD), Electrochemical Detector (ED) |
| Column Compatibility | Dionex IonPac™ Fast IC and standard capillary columns (≥20 chemistries available) |
| Eluent Generation | Electrolytic eluent generation (EG) for isocratic and gradient elution up to 200 mM (acidic/alkaline) |
| Footprint | Compact integrated benchtop design (<0.5 m²) |