| Brand | Qinji |
|---|---|
| Origin | Shanghai, China |
| Model | QUV1003 (Spray-Type) |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Humidity Range | ≥75% RH |
| Illumination Temperatures | 50°C / 60°C / 70°C (60°C recommended) |
| Condensation Temperature | 50°C (±3°C) |
| Cycle Options | 4h UV / 4h Condensation or 8h UV / 4h Condensation |
| UV Lamp Type | UV-B (280–315 nm) |
| Lamp Center-to-Center Spacing | 65–70 mm |
| Specimen-to-Lamp Distance | 55 mm |
| Standard Specimen Size | 75 × 150 mm |
| Water Consumption | 8 L/day (deionized or distilled water required) |
| Interior Dimensions (D×W×H) | 450 × 1165 × 500 mm |
| External Dimensions (D×W×H) | 600 × 1325 × 1480 mm |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| Brand | OK Instruments |
|---|---|
| Model | OK-UV-290 |
| Chamber Internal Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temperature Control Accuracy | ≤±0.5 °C |
| Temperature Uniformity | ≤±2 °C or ≤±3% |
| UV Light Source | Fluorescent UV Lamps (UVA-340 or UVB-313 typical, 280–400 nm) |
| Lamp Lifetime | ~1500 h |
| Exposure Time Setting Range | 0–999 h |
| Construction Material | SUS#304 Stainless Steel (Interior & Exterior) |
| Heating System | U-shaped Titanium Alloy High-Speed Heating Elements |
| Safety Protections | Interlocked Door Cut-off, Over-Temperature Protection, Low-Water Level Detection |
| Power Supply | AC 220 ±5 V, 50 ±0.5 Hz |
| Brand | OEM / Industrial Grade |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Pricing | USD 3,150 (FOB) |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temp. Control Accuracy | ≤±0.5 °C |
| Temp. Uniformity | ≤±2 °C or ≤±3% |
| UV Wavelength Range | 280–400 nm |
| UV Lamp Type | Fluorescent UVA-340 / UVB-313 (typical) |
| Lamp Lifetime | ~2,000 h |
| Exposure Time Range | 0–999 h (adjustable) |
| Interior Dimensions (W×H×D) | 114×40×40 cm |
| Exterior Dimensions (W×H×D) | 135×140×65 cm |
| Construction Material | SUS#304 Stainless Steel (interior & exterior) |
| Heating System | U-shaped Titanium Alloy Heaters |
| Safety Features | Door-interlocked UV cutoff, Over-temperature Protection, Low-water Level Cut-off |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | QUV1003 (Spray-Type) |
| Price | USD 7,800 (FOB Shanghai) |
| Cycle Options | 4h UV irradiation + 4h condensation OR 8h UV irradiation + 4h condensation |
| Irradiance | 0.72 W/m² @ 313 nm |
| Lamp Power | 25 W per UV-B lamp |
| Humidity Range | ≥75% RH (condensation mode) |
| Irradiation Temperature Range | RT+10°C to 70°C |
| Black Panel Temperature Range | RT+10°C to 70°C |
| UV Spectrum | UV-B, 280–315 nm |
| Chamber Internal Dimensions (L×W×H) | 450 × 1165 × 500 mm |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | 16S |
| Spectral Class | ASTM "A"-Grade UV Output |
| Spectral Range | UVB (280–320 nm) and UVA (320–400 nm) |
| Beam Diameter Options | 1 cm or 3 cm |
| Irradiance Range | 1–700 J/m²/min |
| Uniformity | ±5% |
| Output Stability | ±2% |
| Calibration | NIST-traceable |
| Compliance | ASTM G151, ASTM G155, COLIPA, JCIA, FDA Photobiological Safety Standards |
| Cooling | Cold-filtered (heat-free UV irradiation) |
| Lamp Type | 150 W or 300 W Xenon Arc Lamp |
| Power Supply | XPS200 (200 W) or XPS400 (400 W) |
| Integrated Igniter | Yes |
| Optical System | Precision collimating and homogenizing optics |
| Warranty | 1 year standard (extendable) |
| Technical Support | Lifetime toll-free phone support |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | LAL |
| Radiation Source | Metal Halide Lamp with CIE 85 Spectral Match |
| Power Supply | Electronic Power Supply (EPS-Modul) with Square-Wave Current Drive |
| Spectral Range | 280–4000 nm (UV–NIR), UV-A/UV-B selectable via filters |
| Irradiance Uniformity | ±5% over defined test area |
| Control Interface | PC-based menu-driven software with programmable test sequences |
| Positioning System | Motorized 2-axis mechanical tracking mount (optional) |
| Compliance | DIN 75220, SAE J2527/J2412, MIL-STD-810G Method 505.6, EPA Protocol 40 CFR Part 1065 |
| Modular Design | Configurable radiation unit size, mounting system, and filter sets |
| Lamp Lifetime | >1,500 hours under EPS-controlled operation |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,000 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamps |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature (BPT) Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter System | Custom High-Borosilicate Glass + 30% IR-Blocking Filter (optional) |
| Irradiance Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Display & Control | LCD-based Irradiance Accumulation Meter with Auto-Calculation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Time | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ±8 W/m² |
| UV Sensor | Calibrated UV Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Filter Requirement | Optional 30 % IR-reducing filter |
| Irradiance Monitoring | LCD-based integrated radiometric energy integrator |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Calibrated UV Spectral Irradiance Transmitter (Developed by No. 622 Research Institute) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| UV Irradiance | 200 ± 8 W/m² |
| UV Spectral Irradiance Transmitter | Integrated, developed by Beijing Institute of Space Mechanics and Electricity (622 Institute) |
| IR-Reduction Filter | Custom 30% infrared energy attenuation filter (optional, specify at order) |
| Irradiance Monitoring | LCD-based cumulative irradiance meter with real-time auto-calculation |
| Cooling System | Internal forced-air circulation cooling |
| UV Transmitting Filter | Single custom high-borosilicate glass filter |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ± 8 W/m² |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90 % |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50 ± 10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Direct Reflective Illumination |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance | 200 ± 8 W/m² (broadband, 295–450 nm) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| IR Filter | Optional 30% infrared energy rejection filter |
| Irradiance Monitoring | LCD-based Cumulative Irradiance Integrator |
| Cooling Method | Internal Forced-Air Circulation System |
| Irradiance Uniformity | ≥90% across sample plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Heating Time | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Configuration | Top-mounted, Reflective Direct Illumination |
| Irradiance Uniformity | ≥90% |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| IR Filter | Optional 30% Infrared Energy Blocking Filter |
| Irradiance Monitoring | LCD-Based Cumulative Irradiance Integrator with Real-Time Calculation |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (Single) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across rack surface |
| UV Monitoring | Integrated UV Spectral Irradiance Transmitter (developed by China Academy of Engineering Physics – Institute 622) |
| Filter System | Custom High-Borosilicate Glass + IR-Blocking Filter (removes ~30% infrared energy) |
| Control Interface | LCD-based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Cooling Method | Internal Forced-Air Circulation System |
| Compliance | Designed per ISO 4892-2, ASTM G155, SAE J2527, and GB/T 16422.2 requirements |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Sample Rack Dimensions | 500 × 400 mm |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90% |
| Black Panel Temperature Range | 40–85 °C |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass (IR-Reduction ~30%) |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (calibrated per ISO 4892-2) |
| Control Display | LCD-Based Irradiance Integration & Cumulative Dose Monitoring |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Sample Capacity | 500 × 400 mm Test Tray |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Uniformity | ≥90% across Exposure Plane |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass + Optional IR-Reduction Filter (30% IR attenuation) |
| UV Monitoring | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Control Interface | LCD-Based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Output | 295–450 nm (UV-A/UV-B/Visible) |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Temperature Range | RT to 85°C (operational test temp: 50 ± 10°C) |
| Humidity Range | 40–70% RH (lighting), 50–90% RH (dark cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Rack | 500 × 400 mm stainless steel rack |
| Irradiation Geometry | Top-mounted, direct-reflection configuration |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across exposure area |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ±8 W/m² (295–450 nm) |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (Calibrated per ISO 17025 Traceable Standards) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm (UV-A/UV-B broadband) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral UV Irradiance Transmitter (developed by China Academy of Engineering Physics, Institute 622) |
| IR Filtering | Optional 30 % infrared energy rejection filter (custom order required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Reflector-Assisted Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90% across Exposure Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Operational Control) |
| Humidity Control | Simulated Dew via Condensation |
| Spray Function | Optional Water Spray Nozzle Assembly |
| Compliance | Designed to meet ASTM G154, ISO 4892-3, and SAE J2020 test protocols |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (Reference Only) |