UV Aging Test Chamber
Filter
Showing 121–150 of 253 results
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Qlab QUV |
| Pricing | Upon Request |
| Irradiance Temperature Range (°C) | Configurable per ASTM G154 and ISO 4892-3 |
| Black Panel Temperature Range (°C) | 30–75 °C (standard operation) |
| UV Wavelength Options | UVA-340 (315–400 nm), UVA-351 (320–400 nm), UVB-313 (280–360 nm) |
| Chamber Dimensions (L×W×H) | 112 × 50 × 42 cm (44 × 20 × 16.5 in) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| Chamber Dimensions (L×W×H) | 114 × 50 × 42 cm |
| Light Source | Fluorescent UV-B (UV-340) or UV-A (UV-351) lamps |
| Irradiance Control | None (fixed-output lamps) |
| Condensation Humidity Simulation | Yes |
| Water Spray Function | No |
| Sample Capacity | 50 specimens (75 × 150 mm) |
| Black Panel Temperature Range | 35–60 °C |
| Irradiance Stability | ±5% over lamp life |
| Lamp Life | ~1600 hours (UV-B), ~5000 hours (UV-A) |
| Power Supply | 120 V/60 Hz, 14 A or 230 V/50–60 Hz, 7 A |
| Water Consumption | 8 L/day (condensation only) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| Compliance | ASTM G154, ISO 4892-3, IEC 60068-2-5, SAE J2020 |
| UV Lamp Options | UVA-340 (295–365 nm), UVB-313 (280–365 nm) |
| Condensation Cycle | Simulated dew via heated water pan |
| Temperature Control | Black panel thermometer (BPT) and chamber air temperature regulation |
| User Interface | Microprocessor-based controller with real-time exposure condition display |
| Calibration | Patented AutoCal system |
| Connectivity | Ethernet port for data logging and remote diagnostics |
| Software Option | Q-Lab’s “Virtual Strip Chart” PC software (Windows-compatible) |
| Water System | Tap water compatible for condensation |
| Operational Duty | Continuous 24/7 unattended operation |
| Safety & Compliance Features | Built-in self-diagnostic alerts, service reminders, automatic shutdown on fault detection |
| Data Integrity | Audit-trail capable with timestamped exposure logs (supports GLP/GMP documentation requirements per FDA 21 CFR Part 11 when paired with validated software) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| UV Wavelength Range | 320–400 nm (UVA-340 primary spectral output) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Cooling Mechanism | Water-cooled condensation system |
| Lamp Type | Fluorescent UV-B or UV-A lamps (standard UVA-340 or UVB-313) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, and other core UV exposure standards |
| Control System | Fixed-intensity timer-based operation (no irradiance feedback or SOLAR EYE® sensor) |
| Chamber Dimensions | Custom-configurable — consult technical specifications sheet for exact internal volume (L×W×H) |
| Operating Temperature Range (Black Panel) | 40–75 °C (typical operational range) |
| Illuminated Surface Temperature | Ambient to 60 °C (dependent on lamp type and cycle) |
| Humidity Simulation | Condensation-only (non-spray, non-humidity-controlled) |
| Power Supply | 120/240 VAC, 50/60 Hz (model-dependent) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| UV Wavelength Range | 320–400 nm (UVA-340 & UVB-313 lamp options standard) |
| Sample Capacity | 24 specimens (75 mm × 300 mm) or 48 specimens (75 mm × 150 mm) |
| Condensation Cycle | Simulated dew via heated water reservoir and controlled chamber humidity |
| Irradiance Control | Optional CR-10 radiometer-based feedback system with NIST-traceable calibration |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, and other international UV exposure standards |
| Black Panel Temperature Range | 40–75 °C (adjustable per test protocol) |
| Operating Ambient | 10–30 °C, < 80% RH non-condensing |
| Cabinet Dimensions (approx.) | 1100 mm (L) × 600 mm (W) × 500 mm (H) |
| Weight | ~90 kg (net) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| UV Wavelength Range | 280–400 nm |
| Compliance | ASTM G154, ISO 11507, JIS D0205, SAE J2020, ASTM D4587, ISO 4892-3, DIN 53384, GM 9125P, NACE TM-01-84 |
| Sample Capacity | Two 75 mm × 150 mm specimens per rack |
| Light Source | Fluorescent UV lamps (UVA-340 standard) |
| Condensation Mechanism | Water-cooled condensate cycle |
| Irradiance Control | None (manual lamp replacement & positioning required) |
| Chamber Construction | Stainless steel interior, insulated enclosure |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| UV Wavelength Range | 280–400 nm |
| Compliance | ASTM G151, ASTM G154, ISO 4892-3, ISO 11507, JIS D0205, SAE J2020, GB/T 14522 |
| Control System | Programmable microprocessor controller with self-diagnostic function |
| Condensation Mechanism | Water condensation via heated chamber air and cooled specimen surface |
| Lamp Type | Fluorescent UV-A (UVA-340) or UV-B (UVB-313) lamps |
| Chamber dimensions | Custom-configurable — contact technical support for volume specifications |
| Operating temperature range (black panel) | 30–70 °C (typical, model-dependent) |
| Light exposure cycle | Adjustable UV-only or UV/condensation alternating cycles |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/basic |
| Test Duration | 1–5000 h |
| Humidity Range | 0–95% RH |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength | 340 nm |
| Lamp Type Compatibility | UVA-340, UVA-351, UVB-313 |
| Irradiance Control | None (no SOLAR EYE sensor) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/cw |
| Test Duration | 1–5000 h |
| Irradiance Range | 10 W/m² |
| UV Wavelength | 340 nm |
| Light Source | Cold-white fluorescent lamps |
| Irradiance Control System | SOLAR EYE® Visible-light monitoring and feedback control |
| Condensation System | Tap-water-based |
| Temperature Control | Black panel temperature and chamber air temperature (exact ranges available upon request) |
| Compliance | Preloaded ISO and ASTM test protocols (e.g., ISO 4892-3, ASTM G154) |
| Data Logging | Built-in Ethernet-enabled recorder with automatic timestamped event logging, alarm history, and diagnostic traceability |
| Calibration Support | AutoCal®-compatible |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/cw |
| UV Wavelength Range | 320–400 nm |
| Light Source Type | Cold-White Fluorescent Lamps |
| Irradiance Control | SOLAR EYE® Visible-Light Monitoring System |
| Condensation Capability | Yes (with controlled humidity cycle) |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Lamp Lifetime | Approx. 5,000 hours |
| Compliance | ASTM G154, ISO 4892-3, IEC 60068-2-5, JIS D 0205, SAE J2020 (where applicable for visible-light exposure protocols) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/cw |
| UV Wavelength Range | 280–400 nm |
| Lamp Type | Cold White Fluorescent (CW) |
| Compliance | ISO 9000, ISO 4892-3, ASTM G154, IEC 60068-2-5 |
| Sample Mounting | Clip-in Rack System |
| Control System | Digital PID Controller with Manual/Programmable Modes |
| Chamber Construction | Stainless Steel Interior, Aluminum Exterior |
| Safety Features | Over-temperature Protection, UV Interlock Door Switch, Ground Fault Circuit Interrupter (GFCI) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/CW |
| UV Wavelength Range | 280–400 nm |
| Sample Capacity | 24 specimens (75 mm × 300 mm) or 48 specimens (75 mm × 150 mm) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, IEC 61215, GB/T 14522 |
| Calibration Support | CR-10/CW Radiometer with traceable NIST-calibrated reference sensor |
| Condensation System | Gravity-fed distilled/deionized water reservoir with external level indicator |
| Irradiance Control | “SunEye” closed-loop feedback system with real-time spectral irradiance monitoring and auto-compensation |
| Lamp Type | UVA-340 or UVB-313 EL (CW-specific), rated lifetime ≥1600 h under controlled irradiance |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/se, QUV/spray |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Exposure Duration | 1–9999 hours (programmable) |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Compliance | ASTM G154, ISO 4892-3, IEC 61215, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (software-enabled audit trail optional) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/SE |
| UV Lamp Types | UVA-340, UVA-351, UVB-313, QFS-40, Cool White (QUV/cw only) |
| Irradiance Control | SOLAR EYE closed-loop feedback system |
| Condensation Mechanism | Water distillation via natural evaporation/condensation cycle |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, and other international UV exposure standards |
| Software Interface | Multilingual (English, French, Spanish, Italian, German), real-time exposure condition display, self-diagnostic alerts, AUTOCAL calibration assistant |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QUV/se |
| Irradiance Range | 0.48–0.95 W/m² @ 340 nm |
| Exposure Time | Adjustable from 1 to 9999 hours |
| UV Wavelength Range | 250–400 nm |
| Chamber Capacity | Up to 48 specimens (75 mm × 150 mm each) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 280–400 nm |
| Chamber Dimensions (L×W×H) | 137 × 53 × 135 cm |
| Sample Capacity | 48 specimens (75 mm × 150 mm) |
| Irradiance Control | SOLAR EYE closed-loop feedback system |
| Condensation Simulation | Yes |
| Water Spray Option | Not included (standard QUV/se model) |
| Lamp Type | UVB-313 or UVA-340 selectable |
| Lamp Life | 5,000 hours (typical) |
| Temperature Range (Irradiation) | 45–80 °C |
| Temperature Range (Condensation) | 40–60 °C |
| Power Supply | 120/60 V/Hz, 16 A or 230/50–60 V/Hz, 8 A |
| Water Consumption | ~8 L/day (condensation only) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/Se |
| Test Duration | Adjustable |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | Adjustable |
| Light Exposure Temperature Range | 45–80 °C |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 320–400 nm |
| Chamber Dimensions (L×W×H) | 48 cm × 75 cm × 150 cm |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SE |
| Chamber Dimensions (L×W×H) | 114 × 50 × 40 cm |
| Light Source Options | UVA-340 or UVB-313 fluorescent lamps |
| Irradiance Control | Solar Eye® closed-loop feedback system |
| Black Panel Temperature Range | 35–80 °C |
| Condensation Temperature Range | 40–60 °C |
| Illumination Temperature Range | 45–80 °C |
| Sample Capacity | 48 specimens (75 × 150 mm) |
| Power Supply | 120 V / 60 Hz, 16 A or 230 V / 50–60 Hz, 8 A |
| Water Consumption | 8 L/day (condensation mode) |
| Lamp Life (avg.) | 5000 h |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 280–400 nm |
| Sample Capacity | 24 pieces of 75 mm × 300 mm specimens or 48 pieces of 75 mm × 150 mm specimens |
| Lamp Options | UVB-313 (for aggressive, high-intensity UV stress) and UVA-340 (spectrally matched to terrestrial solar UV, 295–365 nm) |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, ISO 11507, JIS K 5600-7-8, SAE J2020, DIN 53384, GB/T 14522, and other international weathering standards |
| Condensation Capability | Yes, for realistic moisture cycling simulation |
| Irradiance Control | Solar Eye® closed-loop feedback system calibrated per ISO/IEC 17025-accredited procedures |
| Chamber Construction | Stainless steel interior, corrosion-resistant housing, precision-engineered UV reflector geometry |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | QUV/se |
| Price | Upon Request |
| UV Irradiance Control | SOLAR EYE Feedback System |
| UV Lamp Types | UVA-340, UVA-351, UVB-313, QFS-40, Cool White (QUV/se/cw only) |
| Black Panel Temperature Range | 35–80 °C |
| Chamber Temperature Range | 25–80 °C |
| UV Wavelength Range | 295–400 nm (lamp-dependent) |
| Test Chamber Dimensions (L×W×H) | 114 × 51 × 42 cm |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Condensation Mechanism | Distilled-water-equivalent cold condensation using tap water |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, MIL-STD-810, FDA 21 CFR Part 11 (with optional software) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB-QUV/se |
| Sample Capacity | 48 × 75 mm × 150 mm specimens |
| UV Lamp Options | UVA-340 (295–365 nm), UVB-313 (peak at 313 nm) |
| Condensation Humidity Simulation | Yes, via heated water pan |
| SOLAR EYE Irradiance Control System | Yes, with ISO-traceable calibration |
| Temperature Control | Black panel temperature range up to 80 °C, chamber air temperature up to 70 °C |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, and other international UV weathering standards |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| Light Exposure Temperature Range | 45–80 °C |
| Condensation Temperature Range | 40–60 °C |
| UV Wavelength Range | 290–400 nm (UVA-340 & UVB-313 lamp options) |
| Chamber Internal Dimensions (L×W×H) | 110 × 105 × 50 cm |
| Sample Capacity | 48 standard panels (75 × 150 mm) |
| Power Supply | 230 V / 50 Hz, 1500 W |
| Weight | 136 kg |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| Sample Capacity | 24 pcs (75 mm × 300 mm) or 48 pcs (75 mm × 150 mm) |
| UV Irradiance Control | Yes (Solar Eye® feedback system) |
| Condensation Simulation | Yes |
| Compliance | ASTM G154, ISO 4892-3, JIS K 5600-7-8, SAE J2020, GB/T 14522, and other international standards |
| Chamber Dimensions (L×W×H) | As specified in technical documentation |
| Black Panel Temperature Range | As specified in technical documentation |
| UV Wavelength Range | UVA-340 (315–400 nm) or UVB-313 (280–315 nm), configurable per lamp type |
| Illumination Uniformity | ±15% across specimen plane per ASTM G154 Annex A1 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 280–400 nm |
| Condensation System | Yes |
| Irradiance Control | SOLAR EYE® Feedback-Controlled UV Intensity |
| Sample Capacity | Up to 48 specimens (75 mm × 150 mm) |
| Temperature Control | Precise black-panel and chamber air temperature regulation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, FDA 21 CFR Part 11 (with optional software), GLP/GMP-ready data logging |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/se |
| UV Wavelength Range | 295–400 nm (UVA-340), 280–360 nm (UVB-313) |
| Black Panel Temperature Range | 30–75 °C |
| Irradiance Control | SOLAR EYE® Closed-Loop Radiometric Feedback System |
| Condensation Mechanism | Water Jacket Heating with 100% RH Saturation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, FDA 21 CFR Part 11 (via optional audit trail software) |
| Sample Capacity | Configurable per standard chamber dimensions (standard internal volume: 45 L) |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model Variants | QUV/se, QUV/spray, QUV/cw, QUV/uvc |
| Lamp Power | 1800 W |
| Humidity Range | ≥95% RH |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength | 340 nm (UVA-340) |
| Chamber Dimensions (L×W×H) | 137 × 53 × 135 cm |
| Test Duration Capability | Up to 5000 hours |
| Compliance | ASTM G154, ASTM G151, ISO 4892-3, JIS D0205, SAE J2020, ISO 11507, IEC 60335, AATCC TM186, and others |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV/se/Spray |
| Quotation | Upon Request |
| UV Wavelength Range | 340–400 nm |
| Chamber Dimensions (L×W×H) | 137 × 53 × 135 cm |
| Black Panel Temperature Range | Consult Technical Support |
| Irradiance Control | Solar Eye® Feedback System |
| Condensation Simulation | Yes |
| Water Spray Function | Yes |
| Sample Capacity | Up to 48 standard specimen racks (each holds two 75 × 150 mm samples) |
| Calibration | ISO/IEC 17025-compliant via CR-10 UV Radiometer traceable to NIST |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | QUV/SP |
| Pricing | Upon Request |
| UV Irradiance Control | SOLAR EYE® Radiometric Feedback System |
| Black Panel Temperature Range | 35–80 °C (adjustable) |
| Cabinet Dimensions (L×W×H) | 1120 × 570 × 540 mm |
| Internal Chamber Volume | ~34 L |
| UV Lamp Type | UVA-340 or UVB-313 Fluorescent Lamps |
| Condensation Cycle | Automatic distilled-water condensation via heated water pan |
| Spray Function | Optional integrated water spray (deionized water recommended) |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, IEC 61215, GB/T 14522, MIL-STD-810G |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | QUV/SP |
| Light Source Options | UVA-340, UVA-351, UVB-313, QFS-40, Cool White Fluorescent |
| Temperature Control | Black Panel & Chamber Air Temperature |
| Condensation Simulation | Yes |
| Irradiance Control | Solar Eye® (Standard on QUV/SP) |
| Compliance | ASTM D4329, ASTM D4587, ISO 11507, IEC 61345, AATCC TM186, and over 30 additional international standards |
| Chamber Dimensions | See technical datasheet |
| Warranty | 5,000-hour lamp life guarantee |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | QUV/Spray |
| Test Duration | 1–5000 h |
| Irradiance Range | Adjustable |
| Lamp Power | Adjustable |
| Humidity Range | 0–95% RH |
| Black Panel Temperature Range | 45–80 °C |
| UV Wavelength Range | 280–400 nm |
| Spray Nozzles | 12 (Total Flow Rate: 7 L/min) |
| Sample Capacity | 48 standard panels (75 × 150 mm) |
| Irradiance Control | Closed-loop “SunEye” system with ±0.01 W/m² @ 340 nm display resolution |
| Compliant Standards | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020, GB/T 14522, DIN 50017, BS EN 60068-2-5 |