- All
- Favorite
- Popular
- Most rated
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Modules | 2 |
| Simultaneous Parameters per Module | Up to 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (portable), AVVOR 9000 (online) |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV) |
| Detection Range | Sub-ppb to low ppb (e.g., 0.05–100 µg/L, matrix-dependent) |
| Supported Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Output Interfaces | 4–20 mA (×8), RS-232, RS-485 |
| Data Management | Onboard LCD (AVVOR 8000), Dual-screen option (AVVOR 9000), PC software with audit trail, GLP-compliant reporting |
| Power | Rechargeable Li-ion battery (AVVOR 8000) |
| Enclosure Rating | IP67 (AVVOR 8000) |
| Brand | Teledyne RDI |
|---|---|
| Origin | USA |
| Model | ChannelMaster H-ADCP |
| Frequency Options | 300 kHz, 600 kHz, 1200 kHz |
| Velocity Range | ±10 m/s (configurable) |
| Velocity Resolution | 0.1 mm/s |
| Depth Cell Size | 0.1–2.0 m (user-selectable, up to 128 cells) |
| Water Level Sensors | Ultrasonic (0.1–10 m, ±0.25% FS, 0.01 cm res), Pressure (0.1–10 m, ±0.5% FS, 0.1 cm res) |
| Temperature Sensor | −4 °C to +40 °C (±0.2 °C, 0.01 °C res) |
| Tilt Sensor | Dual-axis (±10°, ±0.2° @ 0°, ±0.5° @ 10°, 0.01° res) |
| Memory | 4 MB internal flash |
| Communication | RS-232, RS-422, SDI-12 v1.3 |
| Power | 10–18 VDC (typical consumption: 0.13–0.16 W |
| standby | 0.25 mW) |
| Housing | Polyurethane-cast body, titanium fasteners, stainless steel mounting frame |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Detection Principle | Anodic Stripping Voltammetry (ASV) & Cathodic Stripping Voltammetry (CSV) |
| Detection Range | Sub-ppb to low ppb levels (e.g., As(III): 0.05–100 µg/L |
| Cd | 0.02–50 µg/L |
| Pb | 0.03–100 µg/L |
| Hg | 0.01–20 µg/L |
| Cu | 0.05–200 µg/L |
| Zn | 0.1–500 µg/L |
| Ni, Cr, Mn | optional with dedicated electrodes) |
| Measurable Elements | As(III), Total As, Cd, Cr(VI), Cu, Pb, Hg, Mn, Ni, Zn |
| Operating Temperature | –20 °C to +70 °C |
| IP Rating | IP67 |
| Data Storage | 1,000 measurement records with sample ID, timestamp, and operator notes |
| Power Options | Rechargeable Li-ion battery (≥50 assays per charge), AC adapter, 12 V DC car socket |
| Display | 128 × 128 pixel backlit monochrome LCD |
| Interface | Joystick navigation, USB 2.0 for data export and firmware/software updates |
| Electrode System | Triple-electrode immersed probe (working, reference, counter), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to three working electrodes simultaneously installed |
| Compliance | CE-marked |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Electrode Options | Gold, Mercury-plated, Bismuth-plated, and Bare Carbon Working Electrodes |
| Max Simultaneous Metals | 5 per module (up to 2 modules) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in compliance with ISO 10560, ASTM D3559, and EPA Method 7063 for trace metal analysis in aqueous matrices |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Sb³⁺, Tl, Fe, Ni, Sn, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> trace metal guidance |
| Environmental Rating | IP65 enclosure with humidity-resistant design |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Teledyne RDI (distributed by AVVOR) |
|---|---|
| Origin | USA |
| Model | ChanneIMaster H-ADCP |
| Frequency Options | 300 kHz |
| Velocity Accuracy | ±0.5% of measured value or ±0.2 cm/s (whichever is greater) |
| Velocity Resolution | 1 mm/s |
| Velocity Range | ±5 m/s (default), ±20 m/s (max) |
| Cell Size Range | 0.25–8 m (model-dependent) |
| Maximum Profiling Range | 20–300 m (model-dependent) |
| Beam Configuration | Dual-beam, ±20° tilt, 1.5–2.2° beam divergence |
| Memory | 4 MB internal |
| Integrated Sensors | Ultrasonic water level sensor, pressure transducer, tilt sensor (pitch & roll) |
| Standard Cell Count | 128 user-configurable cells |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (HM-1, HM-2, HM-3) and AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurement Range | Sub-ppb to ppm |
| Electrode Options | Gold, Mercury-film, Bismuth-film, and Bare Carbon Working Electrodes |
| Output Interfaces | Dual 4–20 mA analog outputs, RS-232, RS-485 |
| Compliance | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, and EPA Method 7000B |
| Software | Onboard data logging with timestamped audit trail, GLP-compliant reporting |
| Enclosure Rating | IP65 (AVVOR 8000 series), IP67 (AVVOR 9000 outdoor cabinet) |
Show next