BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurable ElementsCu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U
Electrode OptionsGold, Mercury-Film, Bismuth-Film, Bare Carbon
Max Modules2
Simultaneous Parameters per ModuleUp to 5
Analog Outputs8 × 4–20 mA
Digital InterfacesRS-485, RS-232
ComplianceDesigned for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000 (portable), AVVOR 9000 (online)
Measurement PrincipleAnodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV)
Detection RangeSub-ppb to low ppb (e.g., 0.05–100 µg/L, matrix-dependent)
Supported ElementsCu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U
Electrode OptionsGold, Mercury-film, Bismuth-film, Bare Carbon
ComplianceUS EPA Methods 7063, 7472, 1001
Output Interfaces4–20 mA (×8), RS-232, RS-485
Data ManagementOnboard LCD (AVVOR 8000), Dual-screen option (AVVOR 9000), PC software with audit trail, GLP-compliant reporting
PowerRechargeable Li-ion battery (AVVOR 8000)
Enclosure RatingIP67 (AVVOR 8000)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne RDI
OriginUSA
ModelChannelMaster H-ADCP
Frequency Options300 kHz, 600 kHz, 1200 kHz
Velocity Range±10 m/s (configurable)
Velocity Resolution0.1 mm/s
Depth Cell Size0.1–2.0 m (user-selectable, up to 128 cells)
Water Level SensorsUltrasonic (0.1–10 m, ±0.25% FS, 0.01 cm res), Pressure (0.1–10 m, ±0.5% FS, 0.1 cm res)
Temperature Sensor−4 °C to +40 °C (±0.2 °C, 0.01 °C res)
Tilt SensorDual-axis (±10°, ±0.2° @ 0°, ±0.5° @ 10°, 0.01° res)
Memory4 MB internal flash
CommunicationRS-232, RS-422, SDI-12 v1.3
Power10–18 VDC (typical consumption: 0.13–0.16 W
standby0.25 mW)
HousingPolyurethane-cast body, titanium fasteners, stainless steel mounting frame
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelAVVOR 8000 HM-1
PriceUpon Request
Detection PrincipleAnodic Stripping Voltammetry (ASV) & Cathodic Stripping Voltammetry (CSV)
Detection RangeSub-ppb to low ppb levels (e.g., As(III): 0.05–100 µg/L
Cd0.02–50 µg/L
Pb0.03–100 µg/L
Hg0.01–20 µg/L
Cu0.05–200 µg/L
Zn0.1–500 µg/L
Ni, Cr, Mnoptional with dedicated electrodes)
Measurable ElementsAs(III), Total As, Cd, Cr(VI), Cu, Pb, Hg, Mn, Ni, Zn
Operating Temperature–20 °C to +70 °C
IP RatingIP67
Data Storage1,000 measurement records with sample ID, timestamp, and operator notes
Power OptionsRechargeable Li-ion battery (≥50 assays per charge), AC adapter, 12 V DC car socket
Display128 × 128 pixel backlit monochrome LCD
InterfaceJoystick navigation, USB 2.0 for data export and firmware/software updates
Electrode SystemTriple-electrode immersed probe (working, reference, counter), integrated stirrer and Pt100 temperature sensor
ExpandabilityUp to three working electrodes simultaneously installed
ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Electrode OptionsGold, Mercury-plated, Bismuth-plated, and Bare Carbon Working Electrodes
Max Simultaneous Metals5 per module (up to 2 modules)
Output Interfaces8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces
ComplianceDesigned for continuous unattended operation in compliance with ISO 10560, ASTM D3559, and EPA Method 7063 for trace metal analysis in aqueous matrices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurable ElementsAs, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Sb³⁺, Tl, Fe, Ni, Sn, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U
Electrode OptionsGold, Mercury-film, Bismuth-film, Bare Carbon
Max Modules2
Max Simultaneous Parameters per Module5
Analog Outputs8 × 4–20 mA
Digital InterfacesRS-485, RS-232
ComplianceDesigned for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> trace metal guidance
Environmental RatingIP65 enclosure with humidity-resistant design
Power Supply100–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTeledyne RDI (distributed by AVVOR)
OriginUSA
ModelChanneIMaster H-ADCP
Frequency Options300 kHz
Velocity Accuracy±0.5% of measured value or ±0.2 cm/s (whichever is greater)
Velocity Resolution1 mm/s
Velocity Range±5 m/s (default), ±20 m/s (max)
Cell Size Range0.25–8 m (model-dependent)
Maximum Profiling Range20–300 m (model-dependent)
Beam ConfigurationDual-beam, ±20° tilt, 1.5–2.2° beam divergence
Memory4 MB internal
Integrated SensorsUltrasonic water level sensor, pressure transducer, tilt sensor (pitch & roll)
Standard Cell Count128 user-configurable cells
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAVVOR 9000
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000 (HM-1, HM-2, HM-3) and AVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurement RangeSub-ppb to ppm
Electrode OptionsGold, Mercury-film, Bismuth-film, and Bare Carbon Working Electrodes
Output InterfacesDual 4–20 mA analog outputs, RS-232, RS-485
ComplianceDesigned for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, and EPA Method 7000B
SoftwareOnboard data logging with timestamped audit trail, GLP-compliant reporting
Enclosure RatingIP65 (AVVOR 8000 series), IP67 (AVVOR 9000 outdoor cabinet)