- All
- Favorite
- Popular
- Most rated
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for EPA Method 200.8, ISO 11969, and ASTM D3559/D3590 compatibility |
| Environmental Rating | IP65 enclosure with humidity-resistant internal architecture |
| Calibration | Automated on-board standard addition and multi-point calibration routines |
| Brand | Met One |
|---|---|
| Origin | USA |
| Model | BT-610 |
| Flow Rate | 1.0 cfm (28.3 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±10% |
| Repeatability | ±5% |
| Size Channel Resolution | 0.3–10.0 µm (6 calibrated channels at 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm) |
| User-Selectable Sizing | 0.3–2.0 µm in 0.1 µm increments |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/m³) |
| Measurement Accuracy | ±10% (per ISO 21501-4 calibration aerosol) |
| Data Storage Capacity | >8,000 sample events |
| Power | Internal 14.8 V Li-ion battery (8 h continuous / 24 h intermittent) |
| Communication Interfaces | RS-232, RS-485, USB, SD card slot |
| Analog Output | 0–5 VDC |
| Environmental Operating Range | 0–40 °C, 10–90% RH (non-condensing) |
| Dimensions (H×W×D) | 22.2 × 17.1 × 21.5 cm (3.67 kg) |
| Compliance | ISO 21501-4, ISO 14644-1, 21 CFR Part 11, CE, ISO 9001 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| IP Rating | IP67 |
| Power Options | Rechargeable Battery / AC Adapter / Vehicle Cigarette Lighter Socket |
| Operating Time | Up to 6 h (hot-swappable battery) |
| Connectivity | Wi-Fi, GSM Mobile Internet |
| Electrode Configuration | Triple-electrode system (working, counter, reference) + integrated temperature sensor + built-in micro-stirrer |
| Supported Parameters | As(III), Total As, Bi, Cd, Cr, Co, Cu, Au, Fe, Pb, Mn, Hg, Ni, Sn, Zn |
| Detection Limit | Down to 1 ppb (matrix-dependent) |
| Data Handling | On-device AVVOR software for real-time calibration, peak integration (manual/automatic), regression analysis, correlation coefficient calculation, and direct sample concentration derivation |
| Compliance | Designed for field-deployable compliance with EPA Method 200.8, ISO 11969, and ASTM D3559 (adapted for portable ASV platforms) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10 / PM2.5 |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| EPA EQPM Certification | EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Cutoffs | PM₁₀, PM₂.₅, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Frequency | Hourly |
| Filter Tape | Rotating glass fiber tape (30-sample capacity) |
| RH Control | Integrated heater for dew point suppression |
| Data Storage | 182 days (internal) |
| Communication | RS-232 serial interface |
| Meteorological Inputs | Up to 6 sensors |
| Remote Operation | Unattended operation up to 60 days via web-based telemetry |
| Calibration | Automated zero/drift checks per cycle |
| Compliance | U.S. EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited field deployment records |
| Operating Environment | -30°C to +50°C ambient |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation |
| Range | 0–50 mg/m³ |
| Sampling Method | Impaction with Rotating Glass Impactor |
| Filter Tape | Circular, 30-sample capacity |
| Calibration | Automated zero & span drift correction using reference membrane |
| Data Storage | 182 days internal memory |
| Humidity Control | Integrated heater for RH conditioning |
| Connectivity | RS-232 serial interface |
| Compliance | EPA Reference Method for PM2.5 and PM10 |
| Brand | WTW |
|---|---|
| Model | Oxi 3310 |
| Type | Portable |
| Measurement Principle | Galvanic Cell Electrochemical Probe |
| Range | 0.00–19.99 mg/L (conc.), up to 90 mg/L (extended) |
| Accuracy | ±0.5% of reading |
| Repeatability | 0.05% |
| Detection Limit | 0.01 ppb |
| Temperature Range | –5.0 to 105.0 °C (±0.1 °C) |
| Auto-Temperature Compensation (ATC) | Yes |
| Calibration | 1–5-point, automatic recognition of 16 DIN/NIST buffers |
| Data Storage | 5000 automatic + 200 manual entries |
| IP Rating | IP66/IP67 |
| Battery Life | Up to 1000 h (display off), 150 h (backlight on) |
| Interface | Waterproof USB |
| Built-in Barometric Pressure Sensor | Yes |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Modules | 2 |
| Simultaneous Parameters per Module | Up to 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for EPA Method 7063, ISO 11969, ASTM D3559, and GLP/GMP-aligned data integrity protocols |
| Brand | BGI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PQ200 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Measurement Range | 0–10 mg/L Cl₂ |
| Cycle Time | 110 s – 10 min (user-selectable) |
| Accuracy | ±5% or ±0.03 mg/L Cl₂ (whichever is greater) for 0–6 mg/L |
| Resolution | 0.01 mg/L |
| Method | EPA-Approved DPD Colorimetric Analysis |
| Output | 4–20 mA analog + RS-485 with Modbus RTU protocol |
| Alarms | Two user-configurable concentration-based digital alarms |
| Operating Temperature | 5–40 °C |
| Inlet Pressure | 5–150 psi |
| Enclosure Rating | NEMA 4X / IP66 |
| Housing Material | ABS plastic |
| Power Supply | 100–240 V AC, auto-ranging, 47–63 Hz |
| Certifications | CE, UL, CSA, ETL, ETLc |
| Dimensions (L×W×H) | 41 × 41 × 26 cm |
| Weight | 3.6 kg |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000-CODmn |
| Pricing | Available Upon Request |
| Key | Origin: Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | TresCon A |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N (NH₄⁺-N), Total Phosphorus (TP), Total Nitrogen (TN) |
| Module Capacity | Up to 3 Independent Analytical Modules |
| Compliance | Designed for ISO/IEC 17025-aligned operation, supports GLP/GMP data integrity requirements via audit-trail-enabled software |
| Communication | RS-485, Modbus RTU, optional analog 4–20 mA outputs and Ethernet/IP integration |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | AVVOR 9000 NH4-N |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ammonia Gas-Sensing Electrode Method |
| Measurement Range | 0.05–1000 mg/L (multi-range configurable) |
| Accuracy | ±3% FS |
| Detection Limit | 0.01 mg/L |
| Measurement Cycle | 5 min per sample |
| Batch Capacity | 10 samples |
| Compliance | HJ/T 101–2003 (China EPA Standard) |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | VSCC |
| Regulatory Designation | U.S. EPA Reference Method (RFPS-0498-116) |
| EPA EQPM Certification | EQPM-0202-1428 (upgraded to Reference Method, October 17, 2006) |
| Cutpoint | 2.5 µm aerodynamic diameter (D₅₀) |
| Operating Principle | Inertial cyclonic separation |
| Maintenance Interval | Up to 30 days continuous 24-hr sampling before cleaning |
| Cleaning Method | Dry, tool-free, field-cleanable with lint-free cloth and deionized water |
| Compatibility | Direct drop-in replacement for WINS impactor-based FRM samplers (e.g., Thermo Fisher Partisol 2025, Teledyne API models, Met One BAM-1020, etc.) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-3 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | 11 minutes per sample |
| Accuracy | ±1% RSD |
| Resolution | 1 ppb (for most target metals) |
| Detectable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12V DC car socket |
| Data Logging | Internal timestamped storage |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB and optional Bluetooth for PC data upload |
| Accessories Included | Sample cups, photometric cuvettes, full set of calibration buffers and ASV reagents |
| Language Support | Multilingual UI (English, Spanish, French, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (portable), AVVOR 9000 (online) |
| Measurement Principle | Anodic Stripping Voltammetry (ASV) / Differential Pulse Anodic Stripping Voltammetry (DP-ASV) |
| Detection Range | Sub-ppb to low ppb (e.g., 0.05–100 µg/L, matrix-dependent) |
| Supported Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Output Interfaces | 4–20 mA (×8), RS-232, RS-485 |
| Data Management | Onboard LCD (AVVOR 8000), Dual-screen option (AVVOR 9000), PC software with audit trail, GLP-compliant reporting |
| Power | Rechargeable Li-ion battery (AVVOR 8000) |
| Enclosure Rating | IP67 (AVVOR 8000) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 9000 |
| Pricing | Upon Request |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Model | ISCO 4700 |
| Enclosure Material | Rotomolded Linear Low-Density Polyethylene (LLDPE) |
| Operating Temperature Range | –29 °C to +49 °C |
| Refrigeration System | High-Efficiency Compressor with Thermal-Insulated Cabinet |
| Pump Type | Heavy-Duty Peristaltic Pump |
| Maximum Lift Height | 7.6 m |
| Minimum Flow Velocity | 0.6 m/s (per US EPA requirements) |
| Sampling Modes | Time-Proportional, Flow-Proportional (Volume- or Time-Triggered), Composite or Discrete Bottle Sampling |
| Alarm Outputs | 4 Digital Relay Outputs |
| Input Compatibility | 4–20 mA and Pulse Flow Signals |
| Data Logging | Internal 24-hour Temperature & Event Log |
| Software Interface | RS-232 Serial Communication (HyperTerminal-Compatible) |
| Origin | Fujian, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Lawlink System |
| Price Range | USD 70,000 – 140,000 |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | deltaCal DC1 & tetraCal TC5 |
| Flow Range (deltaCal) | 1.5–19.5 L/min |
| Flow Range (tetraCal) | 0.1–30.0 L/min |
| Operating Temperature | −30 °C to +55 °C |
| Barometric Pressure Range | 400–800 mmHg (534–1066 hPa) |
| Temperature Measurement Range | −40 °C to +55 °C |
| Power | 4×AA batteries (20 hr) or universal 120/240 VAC adapter |
| Certifications | NIST-traceable calibration, ISO 9001 certified, compliant with U.S. EPA PM2.5/PM10 field verification requirements |
| Brand | ISCO |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Isco 5800 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Range (Ca²⁺) | 0.02–4010 ppm |
| Detection Range (F⁻) | 0.02–1900 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ±5% of full scale |
| Output Signal | Isolated 4–20 mA (max load 1 kΩ) |
| Operating Temperature | 0–55 °C |
| Enclosure Rating | IP65 |
| Dimensions (H×W×D) | 400 × 300 × 150 mm |
| Display | 7-inch color touchscreen with multilingual UI |
| Data Storage | Internal memory + optional 8 GB microSD/USB drive |
| Calibration | ≥5-point linear or empirical calibration |