| Brand | Met One |
|---|---|
| Origin | USA |
| Model | BT-610 |
| Flow Rate | 1.0 cfm (28.3 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±10% |
| Repeatability | ±5% |
| Size Channel Resolution | 0.3–10.0 µm (6 calibrated channels at 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 µm) |
| User-Selectable Sizing | 0.3–2.0 µm in 0.1 µm increments |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/m³) |
| Measurement Accuracy | ±10% (per ISO 21501-4 calibration aerosol) |
| Data Storage Capacity | >8,000 sample events |
| Power | Internal 14.8 V Li-ion battery (8 h continuous / 24 h intermittent) |
| Communication Interfaces | RS-232, RS-485, USB, SD card slot |
| Analog Output | 0–5 VDC |
| Environmental Operating Range | 0–40 °C, 10–90% RH (non-condensing) |
| Dimensions (H×W×D) | 22.2 × 17.1 × 21.5 cm (3.67 kg) |
| Compliance | ISO 21501-4, ISO 14644-1, 21 CFR Part 11, CE, ISO 9001 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BAM-1020 |
| Measurement Method | Beta Ray Attenuation |
| Measured Parameters | PM10 / PM2.5 |
| Brand | Metone |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| EPA EQPM Certification | EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Cutoffs | PM₁₀, PM₂.₅, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Frequency | Hourly |
| Filter Tape | Rotating glass fiber tape (30-sample capacity) |
| RH Control | Integrated heater for dew point suppression |
| Data Storage | 182 days (internal) |
| Communication | RS-232 serial interface |
| Meteorological Inputs | Up to 6 sensors |
| Remote Operation | Unattended operation up to 60 days via web-based telemetry |
| Calibration | Automated zero/drift checks per cycle |
| Compliance | U.S. EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited field deployment records |
| Operating Environment | -30°C to +50°C ambient |
| Power Requirement | 100–240 VAC, 50/60 Hz |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation |
| Range | 0–50 mg/m³ |
| Sampling Method | Impaction with Rotating Glass Impactor |
| Filter Tape | Circular, 30-sample capacity |
| Calibration | Automated zero & span drift correction using reference membrane |
| Data Storage | 182 days internal memory |
| Humidity Control | Integrated heater for RH conditioning |
| Connectivity | RS-232 serial interface |
| Compliance | EPA Reference Method for PM2.5 and PM10 |
| Brand | BGI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PQ200 |
| Pricing | Upon Request |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | VSCC |
| Regulatory Designation | U.S. EPA Reference Method (RFPS-0498-116) |
| EPA EQPM Certification | EQPM-0202-1428 (upgraded to Reference Method, October 17, 2006) |
| Cutpoint | 2.5 µm aerodynamic diameter (D₅₀) |
| Operating Principle | Inertial cyclonic separation |
| Maintenance Interval | Up to 30 days continuous 24-hr sampling before cleaning |
| Cleaning Method | Dry, tool-free, field-cleanable with lint-free cloth and deionized water |
| Compatibility | Direct drop-in replacement for WINS impactor-based FRM samplers (e.g., Thermo Fisher Partisol 2025, Teledyne API models, Met One BAM-1020, etc.) |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | deltaCal DC1 & tetraCal TC5 |
| Flow Range (deltaCal) | 1.5–19.5 L/min |
| Flow Range (tetraCal) | 0.1–30.0 L/min |
| Operating Temperature | −30 °C to +55 °C |
| Barometric Pressure Range | 400–800 mmHg (534–1066 hPa) |
| Temperature Measurement Range | −40 °C to +55 °C |
| Power | 4×AA batteries (20 hr) or universal 120/240 VAC adapter |
| Certifications | NIST-traceable calibration, ISO 9001 certified, compliant with U.S. EPA PM2.5/PM10 field verification requirements |
| Brand | METONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Available Upon Request |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | Bios Defender 510 & 520 |
| Certification | ISO/IEC 17025 Accredited by NVLAP (NIST) |
| Operating Temperature Range | –20 °C to +50 °C |
| Display | Backlit LCD with Navigation Menu |
| Connectivity | RS-232 Serial Interface |
| Compliance | RoHS Directive 2011/65/EU |
| Flow Units | mL/min, L/min, cc/min, CFM |
| Data Logging | Up to 100+ readings with user-defined intervals (1–60 min) |
| Integrated Sensors | Built-in temperature sensor and pressure transducer (Defender 520 only) |
| Software | PC-based calibration data acquisition, curve plotting, report generation, and GLP-compliant audit trail export |
| Brand | Metone |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E-BAM |
| Pricing | Upon Request |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Model | GT-324 |
| Instrument Type | Handheld |
| Flow Rate | 2.83 L/min |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0.0 s |
| Repeatability | ±5% |
| Size Distribution Accuracy | ±10% |
| Indication Accuracy | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (selectable 4-channel configuration) |
| Concentration Range | 0–3,000,000 particles/ft³ (0–105,900 particles/L) |
| Data Storage Capacity | 2,200 samples |
| Operating Temperature | 0–50 °C |
| Battery Life | 11 h (Li-ion, 7.2 V) |
| Charging Time | 2.5 h |
| Light Source | 780 nm laser diode, 90 mW |
| Display | 16×2 character LCD |
| Interface | Rotary encoder + membrane keypad |
| Communication | USB |
| Compliance | ISO 21501-4, FDA 21 CFR Part 11 (user access control) |
| Brand | MET ONE |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Stack Emission Heavy Metal & Black Carbon Analyzer |
| Model | BC 1054 |
| Measurement Principle | Optical Absorption (Multi-Wavelength Aethalometer Principle) |
| Measurement Range | <1 ng/m³ to >100,000 ng/m³ (effective) |
| Detection Limit | 0.1 ng/m³ |
| Filter Tape Replacement Interval | 24 hours |
| Operating Temperature Range | 1–40 °C |
| Operating Relative Humidity Range | 10–90 % RH (non-condensing) |
| Operating Pressure Range | 80–106 kPa |
| Wavelengths | 370, 430, 470, 525, 565, 590, 660, 700, 880, 950 nm |
| Time Resolution | Standard 1 min |
| Sample Flow Rate | 2 or 5 L/min (user-selectable) |
| Inlet Compatibility | TSP, PM₁₀, PM₂.₅, PM₁ |
| Calibration Method | Factory-calibrated in smoke chamber against traceable NIST-traceable reference standards per ASTM D6216 and ISO 12103-1 |
| Data Output | Analog (4–20 mA), RS-232/RS-485, Ethernet (TCP/IP), Modbus RTU/TCP |
| Compliance | Designed for EPA Reference Method equivalency assessment |
| Brand | Met One Instruments (USA) |
|---|---|
| Origin | USA |
| Model | MetOne 804 |
| Instrument Type | Handheld |
| Flow Rate | 0.1 cfm (2.83 L/min) |
| Flow Accuracy | ±5% |
| Timing Accuracy | ±0 s |
| Repeatability | ±5% |
| Size Distribution Error | ±10% |
| Indication Error | ±10% |
| Particle Size Channels | 0.3, 0.5, 0.7, 1.0, 2.5, 5.0, 10.0 µm (user-selectable, 4 active simultaneously) |
| Concentration Limit | 1,000,000 particles/ft³ (105,900 particles/L) |
| Light Source | 780 nm laser diode, 30 mW |
| Power Supply | 7.2 V Li-ion rechargeable battery (30 h intermittent / 8 h continuous) |
| Dimensions | 9.5 × 17.2 × 5.1 cm (W × H × D) |
| Weight | 0.60 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Data Storage | 2,500 records |
| Display | 2-line × 16-character LCD |
| Interface | USB 2.0 |
| Compliance | ASTM F50, ISO 21501-4, ISO 14644-1, CE, JIS B 9921 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Range | 0–50 mg/m³ |
| Sampling Method | Isokinetic Impactor with Rotating Glass Impactor Plate (30-sample capacity) |
| Data Output | Real-time mass concentration (µg/m³ or mg/m³), automatic zero/drift correction, event logging |
| Compliance | US EPA EQPM, UK MCERTS, Korea K-EMAS, China HJ 653-2013 |
| Brand | METONE |
|---|---|
| Origin | USA |
| Model | BAM-1020 |
| Certification | U.S. EPA EQPM-0798-122 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Particle Size Fractions | PM₂.₅, PM₁₀, TSP |
| Measurement Range | 0–50 mg/m³ |
| Sampling Interval | Hourly |
| Data Storage Capacity | 182 days |
| RH Control | Integrated Heater with Precise Relative Humidity Management |
| Calibration | Automated Zero/Drift Checks per Cycle |
| Output Interface | RS-232 |
| Meteorological Integration | Up to 6 Sensors |
| Remote Operation Duration | Up to 60 Days Unattended |
| Compliance | EPA EQPM, UK MCERTS, Korea KEPIC, China CNAS-accredited Ambient Monitoring Applications |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | PQ167HA |
| Operating Altitude | up to 15,000 ft (4,572 m) |
| Flow Rate | 5.0 L/min (±2% accuracy) |
| Sampling Duration | 24 h on internal DC battery |
| Particle Size Cutpoints | TSP, PM10, PM4.0, PM2.5, PM1.0 |
| Filter Format | 47 mm diameter membrane |
| Compliance | U.S. EPA Federal Reference Method (FRM) for PM2.5 |
| Sampling Head | BGI miniPM with integrated water separator |
| Power Options | Internal rechargeable DC battery + AC adapter |
| Brand | METONE |
|---|---|
| Country of Origin | USA |
| Model | BAM-1020 |
| Measurement Principle | Beta Ray Attenuation (¹⁴C source) |
| Measured Parameters | PM₂.₅, PM₁₀, TSP (with optional inlets) |
| Measurement Range | 0–1.000 mg/m³ |
| Sampling Flow Rate | 16.7 L/min (nominal, adjustable 0–20 L/min) |
| Detection Limit | 0.1 µg/m³ (1-hour average) |
| Measurement Interval | 1 hour |
| Flow Stability | ±2% over operating range |
| EPA Certification | U.S. EPA EQPM-0607-193 (PM₂.₅), EQPM-0607-194 (PM₁₀) |
| Operating Temperature | –30°C to +50°C |
| Relative Humidity Control | Integrated heated inlet with RH stabilization <40% |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T200 |
| Type | Online Gas Analyzer |
| Measurement Principle | Chemiluminescence |
| Detection Targets | NO, NO₂, NOₓ (simultaneously independent) |
| Range Options | 0–50 ppb or 0–20 ppm (dual-range selectable) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 d |
| Response Time (T95) | <60 s |
| Lag Time | 20 s |
| Sample Flow Rate | 500 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Range | 5–40 °C |
| Temp. Coefficient | <0.1%/°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Voltage Coefficient | <0.1%/V |
| Dimensions (H×W×D) | 178 mm × 432 mm × 597 mm |
| Weight (Analyzer) | 18 kg |
| External Pump Weight | 7 kg |
| Power | 100–240 VAC, 50/60 Hz, 250 W |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, isolated 4–20 mA, dual bidirectional RS-232 |
| Certifications | U.S. EPA EQPM Designated, CE, Eignungsgeprüft (German PTB Verification) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T100 |
| Detection Principle | Ultraviolet Fluorescence |
| Measurement Range | 0–50 ppb or 0–20 ppm (selectable dual range) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5%/24 h, <1%/7 d |
| Response Time (T95) | <100 s |
| Sample Flow Rate | 700 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Compensation | Yes |
| Pressure Compensation | Yes |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 16 kg |
| Certifications | U.S. EPA EQPM Designated, Eignungsgeprüft, CE |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T400 |
| Instrument Type | Fixed-mount |
| Measurement Range | 0–10 ppb (standard), optional dual-range 0–100 ppb / 0–10 ppm |
| LOD | <0.6 ppb |
| Response Time (T95) | <20 s |
| Zero Drift | <1.0 ppb/24 h |
| Span Drift | <1% of reading/7 days |
| Resolution | 0.1 ppb (0–50 ppb range) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Output Signals | 0–10 V, 0–5 V, 0–1 V, 0–100 mV, 0–20 mA, or 4–20 mA (isolated) |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T751H |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Flow Rate | 10 SLPM @ 30 psig |
| Max Output Pressure | 30 psig |
| Dew Point | < −20 °C (until desiccant saturation) |
| Desiccant Type | Regenerable, heatless silica gel |
| Desiccant Lifetime | >5 years |
| SO₂ Output Concentration | < 0.025 ppb |
| NO Output Concentration | < 0.025 ppb |
| NO₂ Output Concentration | < 0.025 ppb |
| O₃ Output Concentration | < 0.3 ppb |
| CO Output Concentration | < 10 ppb |
| Hydrocarbon (HC) Output Concentration | < 0.25 ppb |
| Compressor | Single-cylinder, oil-free piston pump |
| Power Input | 110–240 VAC, 50–60 Hz, 425 W |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 229 × 559 × 351 mm |
| Weight | 21.3 kg |
| Brand | API |
|---|---|
| Model | N901 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Measured Parameters | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| NMHC Calculation Method | NMHC = THC − CH₄ |
| Detector Type | Flame Ionization Detector (FID) |
| Sample Inlet Filtration | Stainless Steel Sintered Filter |
| Control & Data Processing | Integrated NumaView™ Software (NVS), Standalone Operation |
| Compliance Context | Designed for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU Directive 2008/50/EC ambient air monitoring requirements |
| Power Consumption | Low-power embedded architecture |
| Design Philosophy | Modular hardware, field-serviceable electronics, maintenance-minimized gas path |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T751 |
| Output Flow Rate | 5 SLPM @ 30 psig |
| Maximum Output Pressure | 30 psig |
| Dew Point | < –20 °C (until desiccant saturation) |
| SO₂, NO, NO₂, O₃, H₂S Removal | < 0.5 ppb |
| CO Removal (with optional CO scrubber) | < 0.025 ppm |
| Compressor Type | Single-cylinder, oil-free piston pump |
| Power Input | 110–240 VAC, 50–60 Hz, 130 W |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 178 × 470 × 356 mm |
| Weight | 10.9 kg |
| Desiccant | Silica gel with dew point LED indicator |
| Warm-up Time | 30 minutes |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T300 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Gas Filter Correlation Infrared Absorption (GFC-IR) |
| Measurement Range | 0–1 ppm or 0–1000 ppm (selectable dual range) |
| Repeatability | ±1% of Full Scale (F.S.) |
| Resolution | 0.1 ppm |
| Response Time (T95) | <60 s |
| Zero Drift | <0.1 ppm/24 h, <0.2 ppm/7 days |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 days |
| Linearity Error | ±1% of full scale |
| Zero Noise (RMS) | <0.02 ppm |
| Span Noise | <0.5% of reading |
| LOD (Limit of Detection) | <0.04 ppm |
| Optical Path Length | 14 m |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Pressure & Temperature Compensation | Yes |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, 4–20 mA (isolated), dual RS-232 (bidirectional) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Certifications | U.S. EPA Designated Method, Eignungsgeprüft (German Performance Verification), CE |