Empowering Scientific Discovery

Xiamen Longlide Environmental Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000 HM-3
Detection PrincipleAnodic Stripping Voltammetry (ASV)
IP RatingIP67
Power OptionsRechargeable Battery / AC Adapter / Vehicle Cigarette Lighter Socket
Operating TimeUp to 6 h (hot-swappable battery)
ConnectivityWi-Fi, GSM Mobile Internet
Electrode ConfigurationTriple-electrode system (working, counter, reference) + integrated temperature sensor + built-in micro-stirrer
Supported ParametersAs(III), Total As, Bi, Cd, Cr, Co, Cu, Au, Fe, Pb, Mn, Hg, Ni, Sn, Zn
Detection LimitDown to 1 ppb (matrix-dependent)
Data HandlingOn-device AVVOR software for real-time calibration, peak integration (manual/automatic), regression analysis, correlation coefficient calculation, and direct sample concentration derivation
ComplianceDesigned for field-deployable compliance with EPA Method 200.8, ISO 11969, and ASTM D3559 (adapted for portable ASV platforms)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUK
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAVVOR 8000 HM-3
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginFujian, China
ModelAVVOR 8000 HM-2
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detection Time11 minutes per sample
Accuracy±1% RSD
Resolution1 ppb (for most target metals)
Detectable ElementsAl, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn
ComplianceIP68-rated enclosure
Power OptionsRechargeable Li-ion battery / AC adapter / 12V DC car socket
Data LoggingInternal timestamped storage
DisplayBacklit LCD with touch keypad
ConnectivityUSB and optional Bluetooth for PC data upload
Accessories IncludedSample cups, photometric cuvettes, full set of calibration buffers and ASV reagents
Language SupportMultilingual UI (English, Spanish, French, German, Chinese)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000 HM-2
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Instrument TypePortable
Measurable ElementsAl, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn
Detection Rangeppb to ppm
Ingress ProtectionIP68
Power OptionsRechargeable battery / AC adapter / Vehicle cigarette lighter socket
Data LoggingTime-stamped internal memory
DisplayBacklit LCD with touch keypad
ConnectivityUSB for PC data upload
Included AccessoriesSample analysis cups, photometric cuvettes, full set of calibration buffers and reagents for 12 metals
Language SupportMultilingual interface
Electrode SystemTriple-electrode immersed probe (working, reference, auxiliary), integrated stirrer and temperature sensor, modular plug-in working electrodes (up to 3 simultaneously)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginFujian, China
ModelAVVOR 8000 HM-1
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsAs(III), Total As, Cd, Cu, Pb, Hg, Mn, Ni, Zn
Detection Time< 300 s per metal
Accuracy±5% RSD (at 10× LOD)
Resolution0.1 ppb (for Cd, Pb, Cu in aqueous matrix)
IP RatingIP67
Data Storage1000 measurement records
Power OptionsRechargeable Li-ion battery, AC adapter, 12 V DC car socket
InterfaceUSB 2.0
DisplayBacklit LCD with joystick navigation
Electrode SystemTriple-electrode immersed probe (WE/RE/AE), integrated stirrer and Pt100 temperature sensor
ExpandabilityUp to 3 interchangeable working electrodes in single probe housing
SoftwareWindows-based ASV Analysis Suite with audit trail, calibration history, and report export (PDF/CSV/XLSX)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000 HM-2
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Target AnalytesAl, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn (12 metals)
Detection Rangeppb to ppm
Accuracy±7.5%
ComplianceIP68-rated enclosure
Power OptionsRechargeable battery / AC adapter / Vehicle cigarette lighter socket
Data LoggingInternal timestamped storage with LCD backlight display
InterfaceTouch keypad, USB for data export
Sample PreparationMinimal—buffer addition and direct water sampling
Analysis TimeRapid (typically < 5 min per metal, multi-parameter in sequence)
Electrode SystemTriple-electrode immersed probe with integrated stirrer and temperature sensor
ExpandabilityUp to three working electrodes in one probe housing
SoftwareOn-device guided workflow with step-by-step visual prompts
Language SupportMultilingual UI
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAVVOR 8000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
ModelAVVOR 8000 HM-3
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detection Time≤1 min per metal
Detection Limit≤1 ppb (for Pb, Cd, Cu, Zn, As, Hg)
Accuracy±5% of reading (at 10 ppb level)
Resolution0.1 ppb
PortabilityIP67-rated ruggedized field instrument
Power OptionsRechargeable Li-ion battery (6 h operation), AC adapter, 12 V DC (cigarette lighter socket)
ConnectivityWi-Fi, GSM/4G LTE, USB, Bluetooth
Electrode Configuration5 interchangeable sensor modules with integrated temperature probe and magnetic stirrer
SoftwareAVVOR ASV Suite v3.2 (compliant with FDA 21 CFR Part 11 audit trail & electronic signature support)
ComplianceMeets ASTM D3559, ISO 8692, USP <232>/<233>, and EPA Method 7000B requirements for trace metal analysis in aqueous matrices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurable ElementsCu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U
Electrode OptionsGold, Mercury-film, Bismuth-film, Bare Carbon
Max. Simultaneous Channels2 modules × 5 elements each
Output Interfaces8 × 4–20 mA analog outputs, RS-485, RS-232
ComplianceDesigned for ASTM D3559, ISO 11929, USP <232>/<233>, EPA Method 7000B & 7473
Environmental CertificationIP65 enclosure, NEMA 4X-rated housing
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelsAVVOR 8000, AVVOR 9000, HM1000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelAVVOR 8000 HM-1
PriceUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginCanada
Manufacturer TypeAuthorized Distributor
Origin CategoryImported Instrument
ModelAVVOR 9000
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
Model8000 HM-2
Instrument TypePortable
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Target AnalytesHg, Cd, Pb, Cu, Zn, Ni, Cr(VI), As, Mn, Fe, Al, B
Detection Time≤30 min per sample
Accuracy±0.5% of reading
Resolution0.5 ppb (for Hg)
IP RatingIP68
Power OptionsRechargeable Li-ion battery / AC adapter / 12 V DC (cigarette lighter socket)
Data StorageInternal timestamped logging
DisplayBacklit LCD with touch keypad
ConnectivityUSB for PC data upload
Language SupportMultilingual (English, French, Spanish, German, Chinese)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
Instrument TypePortable (8000) & Online Continuous Analyzer (9000)
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable ElementsCu, Cd, Pb, Zn, Ni, As, Hg, Cr (total & Cr⁶⁺), Fe, Mn, Sb, Tl, Se, Co, Mo, Ag, Au, Pd, Sn, U
Measurement Time≤30 min per sample (8000)
Accuracy±0.5% of reading
Resolution0.5 ppt (ng/L) for key elements
ComplianceUS EPA Methods 7063, 7472, 1001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Detectable MetalsAs, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Tl, Fe, Ni, Sn, Cr, Cr(VI), Co, Mo, Au, Ag, Pd, U
ConfigurationDual-module support (up to 5 simultaneous metals per module)
Output Interfaces8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces
ComplianceDesigned for continuous unattended operation in industrial effluent, municipal wastewater, surface water, groundwater, drinking water and seawater applications
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurable ElementsCu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U
Electrode OptionsGold, Mercury-Film, Bismuth-Film, Bare Carbon
Max Simultaneous Channels2 modules × 5 elements each
Output Interfaces8 × 4–20 mA analog outputs, RS-485, RS-232
Compliance SupportDesigned for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, EPA Method 7000B (ASV-based), GLP/GMP-ready data logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 9000
Detection PrincipleAnodic Stripping Voltammetry (ASV)
Measurable ElementsCu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U
Electrode OptionsGold, Mercury-film, Bismuth-film, Bare Carbon
Max Modules2
Max Simultaneous Parameters per Module5
Analog Outputs8 × 4–20 mA
Digital InterfacesRS-485, RS-232
ComplianceDesigned for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> guidance
Environmental RatingIP65 Enclosure with Humidity Control
Power Supply100–240 VAC, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAVVOR
OriginCanada
ModelAVVOR 8000
Detection PrincipleAnodic Stripping Voltammetry (ASV) and Spectrophotometry
Detection RangeSub-ppb to ppm levels (e.g., As(III): 0.1–100 µg/L, Cd: 0.05–50 µg/L, Pb: 0.05–50 µg/L, Hg: 0.02–25 µg/L, Cu: 0.1–100 µg/L, Zn: 0.5–200 µg/L)
Supported AnalytesAs(III), Total As, Cd, Cr(VI), Cu, Pb, Mn, Hg, Ni, Zn, Co, Se
ComplianceASTM D3559, ISO 11969, US EPA Method 7000B (ASV), ISO 6603 (spectrophotometric metal chelation)
Data ManagementOnboard tablet with GLP-compliant audit trail, CFR Part 11–ready export, Wi-Fi/Bluetooth connectivity
IP RatingIP67 (instrument housing and integrated tablet)
PowerRechargeable Li-ion battery (≥12 h continuous operation)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0