| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| IP Rating | IP67 |
| Power Options | Rechargeable Battery / AC Adapter / Vehicle Cigarette Lighter Socket |
| Operating Time | Up to 6 h (hot-swappable battery) |
| Connectivity | Wi-Fi, GSM Mobile Internet |
| Electrode Configuration | Triple-electrode system (working, counter, reference) + integrated temperature sensor + built-in micro-stirrer |
| Supported Parameters | As(III), Total As, Bi, Cd, Cr, Co, Cu, Au, Fe, Pb, Mn, Hg, Ni, Sn, Zn |
| Detection Limit | Down to 1 ppb (matrix-dependent) |
| Data Handling | On-device AVVOR software for real-time calibration, peak integration (manual/automatic), regression analysis, correlation coefficient calculation, and direct sample concentration derivation |
| Compliance | Designed for field-deployable compliance with EPA Method 200.8, ISO 11969, and ASTM D3559 (adapted for portable ASV platforms) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-3 |
| Pricing | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | 11 minutes per sample |
| Accuracy | ±1% RSD |
| Resolution | 1 ppb (for most target metals) |
| Detectable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12V DC car socket |
| Data Logging | Internal timestamped storage |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB and optional Bluetooth for PC data upload |
| Accessories Included | Sample cups, photometric cuvettes, full set of calibration buffers and ASV reagents |
| Language Support | Multilingual UI (English, Spanish, French, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Instrument Type | Portable |
| Measurable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Detection Range | ppb to ppm |
| Ingress Protection | IP68 |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Time-stamped internal memory |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Included Accessories | Sample analysis cups, photometric cuvettes, full set of calibration buffers and reagents for 12 metals |
| Language Support | Multilingual interface |
| Electrode System | Triple-electrode immersed probe (working, reference, auxiliary), integrated stirrer and temperature sensor, modular plug-in working electrodes (up to 3 simultaneously) |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-1 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As(III), Total As, Cd, Cu, Pb, Hg, Mn, Ni, Zn |
| Detection Time | < 300 s per metal |
| Accuracy | ±5% RSD (at 10× LOD) |
| Resolution | 0.1 ppb (for Cd, Pb, Cu in aqueous matrix) |
| IP Rating | IP67 |
| Data Storage | 1000 measurement records |
| Power Options | Rechargeable Li-ion battery, AC adapter, 12 V DC car socket |
| Interface | USB 2.0 |
| Display | Backlit LCD with joystick navigation |
| Electrode System | Triple-electrode immersed probe (WE/RE/AE), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to 3 interchangeable working electrodes in single probe housing |
| Software | Windows-based ASV Analysis Suite with audit trail, calibration history, and report export (PDF/CSV/XLSX) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn (12 metals) |
| Detection Range | ppb to ppm |
| Accuracy | ±7.5% |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Internal timestamped storage with LCD backlight display |
| Interface | Touch keypad, USB for data export |
| Sample Preparation | Minimal—buffer addition and direct water sampling |
| Analysis Time | Rapid (typically < 5 min per metal, multi-parameter in sequence) |
| Electrode System | Triple-electrode immersed probe with integrated stirrer and temperature sensor |
| Expandability | Up to three working electrodes in one probe housing |
| Software | On-device guided workflow with step-by-step visual prompts |
| Language Support | Multilingual UI |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | ≤1 min per metal |
| Detection Limit | ≤1 ppb (for Pb, Cd, Cu, Zn, As, Hg) |
| Accuracy | ±5% of reading (at 10 ppb level) |
| Resolution | 0.1 ppb |
| Portability | IP67-rated ruggedized field instrument |
| Power Options | Rechargeable Li-ion battery (6 h operation), AC adapter, 12 V DC (cigarette lighter socket) |
| Connectivity | Wi-Fi, GSM/4G LTE, USB, Bluetooth |
| Electrode Configuration | 5 interchangeable sensor modules with integrated temperature probe and magnetic stirrer |
| Software | AVVOR ASV Suite v3.2 (compliant with FDA 21 CFR Part 11 audit trail & electronic signature support) |
| Compliance | Meets ASTM D3559, ISO 8692, USP <232>/<233>, and EPA Method 7000B requirements for trace metal analysis in aqueous matrices |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11929, USP <232>/<233>, EPA Method 7000B & 7473 |
| Environmental Certification | IP65 enclosure, NEMA 4X-rated housing |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AVVOR 8000, AVVOR 9000, HM1000 |
| Pricing | Available Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AVVOR 9000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Hg, Cd, Pb, Cu, Zn, Ni, Cr(VI), As, Mn, Fe, Al, B |
| Detection Time | ≤30 min per sample |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppb (for Hg) |
| IP Rating | IP68 |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12 V DC (cigarette lighter socket) |
| Data Storage | Internal timestamped logging |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Language Support | Multilingual (English, French, Spanish, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Instrument Type | Portable (8000) & Online Continuous Analyzer (9000) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Cd, Pb, Zn, Ni, As, Hg, Cr (total & Cr⁶⁺), Fe, Mn, Sb, Tl, Se, Co, Mo, Ag, Au, Pd, Sn, U |
| Measurement Time | ≤30 min per sample (8000) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppt (ng/L) for key elements |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Tl, Fe, Ni, Sn, Cr, Cr(VI), Co, Mo, Au, Ag, Pd, U |
| Configuration | Dual-module support (up to 5 simultaneous metals per module) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in industrial effluent, municipal wastewater, surface water, groundwater, drinking water and seawater applications |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance Support | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, EPA Method 7000B (ASV-based), GLP/GMP-ready data logging |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> guidance |
| Environmental Rating | IP65 Enclosure with Humidity Control |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) and Spectrophotometry |
| Detection Range | Sub-ppb to ppm levels (e.g., As(III): 0.1–100 µg/L, Cd: 0.05–50 µg/L, Pb: 0.05–50 µg/L, Hg: 0.02–25 µg/L, Cu: 0.1–100 µg/L, Zn: 0.5–200 µg/L) |
| Supported Analytes | As(III), Total As, Cd, Cr(VI), Cu, Pb, Mn, Hg, Ni, Zn, Co, Se |
| Compliance | ASTM D3559, ISO 11969, US EPA Method 7000B (ASV), ISO 6603 (spectrophotometric metal chelation) |
| Data Management | Onboard tablet with GLP-compliant audit trail, CFR Part 11–ready export, Wi-Fi/Bluetooth connectivity |
| IP Rating | IP67 (instrument housing and integrated tablet) |
| Power | Rechargeable Li-ion battery (≥12 h continuous operation) |