Xylem Analytics China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTCU/A111
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode
Measurement Range0.1–1000 mg/L NH₃–N
Accuracy≤ ±5% FS
Detection Limit0.1 mg/L NH₃–N
Analysis Time3 minutes per sample
Sample Throughput1 sample per cycle
ComplianceCertified per China EPA Environmental Protection Product Certification (HJ 758–2015)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelAlyza IQ
Instrument TypeOnline Analyzer
Measurement PrincipleColorimetric Method
Measurement Range0.02–20 mg/L NH₄–N
Detection Limit0.02 mg/L
AccuracyMR1: ±2% ±0.02 mg/L (0.02–5 mg/L)
MR2±3% ±0.10 mg/L (0.1–20 mg/L)
IntegrationFully compatible with IQ Sensor Net platform (supports IQ System 2020, 282, and 284)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Sensor ModelsAmmoLyt, NitraLyt, VARiON
TypeOnline ISE-based sensor system
Measurement PrinciplePotentiometric ion-selective electrode (ISE) method
Measurement RangesNH₄⁺-N: 1–2000 mg/L (1 mg/L resolution) or 0.1–100 mg/L (0.1 mg/L resolution)
NH₄⁺1–2580 mg/L (1 mg/L) or 0.1–129.0 mg/L (0.1 mg/L)
NO₃⁻-N1–1000 mg/L (1 mg/L) or 0.1–100 mg/L (0.1 mg/L)
NO₃⁻5–4500 mg/L (1 mg/L) or 0.5–450.0 mg/L (0.1 mg/L)
Accuracy±5% of reading ±0.2 mg/L
Detection LimitNH₄⁺-N: 0.1 mg/L
NO₃⁻-N0.1 mg/L
Response Time0–3 min
ComplianceDesigned for continuous operation in wastewater treatment environments per DIN EN ISO 5667-3, ASTM D1426, and EPA Method 350.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTresCon
Instrument TypeOnline Analyzer
Measurement PrincipleGas-Sensing Electrode (NH₄⁺-N), Optical Absorption (NO₃⁻-N), Diazotization Colorimetry (NO₂⁻-N)
Measurement RangeNH₄⁺-N: 0.1–1000 mg/L
NO₃⁻-N0.1–60 mg/L
NO₂⁻-N0.005–1.200 mg/L
Detection LimitNH₄⁺-N: 0.1 mg/L
NO₃⁻-N0.1 mg/L
NO₂⁻-N0.005 mg/L
AccuracyNH₄⁺-N: ±5% of reading ±0.2 mg/L (<1.0 mg/L)
NO₃⁻-N±2% of reading ±0.4 mg/L
NO₂⁻-N±2% of reading ±0.05 mg/L
Cycle TimeMinimum 30 s per parameter
Batch Capacity3 independent measurement channels
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTresCon (NH₄-N + TP)
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode (NH₄-N)
Measurement RangeNH₄-N: 0.1–1000 mg/L
TP0.01–3.00 mg/L (standard), up to 6.00 mg/L with external dilution module
AccuracyNH₄-N: ±5% of reading ±0.2 mg/L (<1.0 mg/L)
TP±3% of reading ±0.05 mg/L
Detection LimitNH₄-N: 0.1 mg/L
TP0.01 mg/L
Minimum Cycle Time3 min (per parameter, configurable)
Sample ThroughputUp to 2 independent sample streams (expandable via multi-channel inlet manifold)
ComplianceDesigned for continuous operation in accordance with EN ISO 15839, ASTM D1426 (ammonia), and ISO 6878 (total phosphorus)