Empowering Scientific Discovery

Xylem Analytics China

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 58
TypePortable
Measurement PrincipleClark-type polarographic electrode
DO Range (mg/L)0–20 mg/L
DO Resolution (mg/L)0.01 mg/L
DO Accuracy (mg/L)±0.03 mg/L
DO Range (% air saturation)0–200%
DO Resolution (% sat)0.1%
DO Accuracy (% sat)±0.3%
Temperature Range−5 to +45 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C
Temp Compensation Range0 to +45 °C
Salinity Compensation Range0–40 ppt
Salinity Compensation Accuracy±0.3% of compensated reading ±1 digit
Recorder Output0–1 V DC (0.5 V = 1 digit), ±0.4% full scale ±1 least significant digit, min. load 50 kΩ
Power4 × D-cell batteries (Zn-C or alkaline), ~1000 h life
Dimensions21.6 × 28.0 × 9.5 cm
Weight1.90 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
ModelTresCon COD-3250
TypeOnline Analyzer
Measurement PrinciplePotassium Dichromate Digestion (High-Temperature Closed-System)
Wavelength620 nm
Range20–5000 mg/L COD
Accuracy≤ ±10% at ≥30 mg/L
Repeatability≤ ±3%
Detection LimitNot Specified
Cycle Time35 min per sample
Sample Throughput1 sample per cycle
ComplianceDesigned to meet GB 11914-1989 and HJ 399-2007 requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 6920DW / 600DW
Residual Chlorine0–3 mg/L (±15% of reading or ±0.05 mg/L, whichever is greater
resolution0.01 mg/L)
Conductivity0–100 mS/cm (±0.5% of reading + 0.001 mS/cm
resolution0.001–0.1 mS/cm, range-dependent)
Temperature−5 to +70 °C (±0.15 °C
resolution0.01 °C)
pH0–14 (±0.2
resolution0.01)
ORP−999 to +999 mV (±20 mV
resolution0.1 mV)
Turbidity0–1000 NTU (±2% of reading or ±0.3 NTU, whichever is greater
resolution0.1 NTU)
Data StorageUp to 150,000 readings
Power OptionsRechargeable battery or AC adapter
ComplianceUS EPA verified (residual chlorine sensor), USGS & DoD validated, ETVP-certified (Environmental Technology Verification Program)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelEXO NitraLED
Instrument TypeSubmersible Optical Nitrate Analyzer for Freshwater
Dimensions21.3 cm (L) × 1.5 cm (D)
Weight0.07 kg
Measurement UnitNO₃–N (mg/L)
Light SourceDual UV LED (235 nm & 275 nm)
Optical Path Length10 mm
Range0–10 mg/L-N
LOD0.005 mg/L-N
Accuracy±0.1 mg/L-N or ±5% of reading (whichever is greater) within ±2 °C
T95 Response Time<30 s
Drift (30-day deployment, 15-min logging)≤0.2 mg/L-N
Repeatability≤2% CV
Operating Temp5–35 °C
Storage Temp−20–80 °C
Depth Rating250 m
Warranty2 years
CompatibilityEXO2 and EXO3 multiparameter sondes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTCU/A111
Instrument TypeOnline Analyzer
Measurement PrincipleAmmonia Gas-Sensing Electrode
Measurement Range0.1–1000 mg/L NH₃–N
Accuracy≤ ±5% FS
Detection Limit0.1 mg/L NH₃–N
Analysis Time3 minutes per sample
Sample Throughput1 sample per cycle
ComplianceCertified per China EPA Environmental Protection Product Certification (HJ 758–2015)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelProQuatro
Instrument TypePortable/Handheld Water Quality Analyzer
Measured ParametersDissolved Oxygen (DO), Electrical Conductivity, Specific Conductivity, Salinity, Resistivity, Barometric Pressure
Dimensions8.3 cm × 21.6 cm × 2.3 cm
Weight (with batteries)475 g
Power SupplyTwo C-cell alkaline batteries (80 h runtime at ambient temperature, backlight off) or micro-USB power input
Operating Temperature−10 °C to +60 °C
Storage Temperature−20 °C to +70 °C
DisplayBacklit graphical LCD
Memory Capacity5,000 data sets with 50 unique ID tags
Data Logging ModesSingle-point or continuous logging with auto-stability detection
Cable OptionsField cables (1, 4, 10, 20, 30 m)
Barometer Range375–825 mmHg
Accuracy±1.5 mmHg (0–50 °C)
Resolution0.1 mmHg
DO Membrane Response Time (T95)8 s (1.25 mil PE, flow = 0.15 m/s), 17 s (2.0 mil PE, flow = 0.08 m/s), 18 s (1 mil Teflon®, flow = 0.30 m/s)
Ingress ProtectionIP67 (submersible even with battery door open)
Warranty3 years instrument, 2 years cables
CertificationsRoHS, CE, FCC
Language SupportEnglish, Simplified/Traditional Chinese, French, German, Italian, Japanese, Norwegian, Portuguese, Spanish
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXylem
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelEMM550
Instrument TypeOnline Water Quality Analyzer
Buoy Construction MaterialSurlyn®-based Ionomeric Foam
Structural DesignModular, Symmetric Circular Hull with Integrated Ballast Chamber
Certified ComplianceNOAA NDBC & USCG Approved Buoy Platform
Deployment ClassCoastal, Estuarine, and Inland Open-Water Long-Term Monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelChlorine 3017M
Instrument TypeOnline Analyzer
Measurement PrincipleDPD Spectrophotometry
Measured ParametersFree Chlorine, Total Chlorine, Chlorine Dioxide (optional reagent configuration)
Range0–5 mg/L (free or total chlorine, reagent-dependent)
Accuracy±0.03 mg/L or ±5% (whichever is greater)
Resolution0.01 mg/L
Detection Limit0.03 mg/L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 6600EDS
DO Range (sat.)0–500% (±2% or 2% sat., whichever greater, 0–200%)
DO Range (mg/L)0–50 mg/L (±2% or 0.2 mg/L, 0–20 mg/L)
Conductivity0–100 mS/cm (±0.5% + 0.001 mS/cm)
Temperature−5 to 50 °C (±0.15 °C)
pH0–14 (±0.2)
ORP−999 to +999 mV (±20 mV)
Salinity0–70 ppt (±1.0% or 0.1 ppt)
Depth (shallow/medium/deep)0–9 m (±0.018 m) / 0–61 m (±0.12 m) / 0–200 m (±0.3 m)
Barometric Pressure Compensated Water Level0–9 m (±0.003 m)
Turbidity0–1000 NTU (±2% or 0.3 NTU)
Chlorophyll-a0–400 µg/L (LOD: 0.1 µg/L
Rhodamine WT0–200 µg/L (±5% or 1.0 µg/L)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTriOxmatic
Instrument TypeOnline Water Quality Analyzer
Measured ParameterDissolved Oxygen (DO)
O₂ Concentration Ranges0.0–60.0 mg/L (TriOxmatic® 700 IQ), 0.00–20.00 mg/L (701 IQ), 0.001–2.000 mg/L (702 IQ)
O₂ Saturation Ranges0–600 %, 0.0–200.0 %, 0–110 %
Resolution0.1 mg/L / 0.01 mg/L / 0.001 mg/L
Response Time (t₉₀)180 s (700 IQ), 30 s (701/702 IQ)
Minimum Flow Rate0.05–0.3 m/s
Temperature CompensationIntegrated NTC, –5 to +60 °C
Accuracy±0.1 mg/L or ±1% of reading
Electrode MaterialsStainless Steel 316, Titanium, POM (for seawater)
Max. Pressure Rating10 bar (standard), 1 bar (F-type)
Power Consumption0.2 W
DiagnosticsSensReg (electrolyte depletion alarm), SensLeck (membrane breach detection)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
Model6820EDS / 6920EDS
Instrument TypeIn-situ Online Water Quality Analyzer
DO (% air saturation)0–500%, ±2% or ±2% air saturation (0–200%), ±6% (200–500%)
DO (mg/L)0–50 mg/L, ±2% or ±0.2 mg/L (0–20 mg/L), ±6% (20–50 mg/L)
Conductivity0–100 mS/cm, ±0.5% + 0.001 mS/cm
Temperature−5 to 50 °C, ±0.15 °C
pH0–14, ±0.2
ORP−999 to +999 mV, ±20 mV
Salinity0–70 ppt, ±1.0% or ±0.1 ppt
Depth (shallow)0–9 m, ±0.018 m
Depth (mid-depth)0–61 m, ±0.12 m
Barometrically Compensated Water Level0–9 m, ±0.003 m
Turbidity0–1000 NTU, ±2% or ±0.3 NTU
Rhodamine WT0–200 µg/L, ±1.0 µg/L or ±5%
Chlorophyll-a0–400 µg/L, LOD 0.1 µg/L, R² > 0.9999
Ammonia-N / Nitrate-N / Chloride (freshwater only)0–200 mg N/L, ±10% or ±2 mg N/L
Sensor CleaningIntegrated YSI Patented Auto-Cleaning Brush (for turbidity, DO, pH)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTCU/COD3260
Measurement PrincipleAcidic Potassium Permanganate Oxidation with Potentiometric Endpoint Detection (Dual Platinum Electrodes)
Temperature Control100 °C ± 1 °C
Detection Range0.5–10 mg/L O₂ (as KMnO₄)
Accuracy±5% of reading (typical, matrix-dependent)
Reagent Consumption≤3.5 mL per analysis cycle
Sample Flow Requirement0.5–2.0 L/min
Power Supply230 VAC, 50/60 Hz
IP RatingIP65 (enclosure)
ComplianceEN ISO 8467:2022, DIN 38409-H12, EPA Method 410.2 (adapted), GLP-ready architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 556MPS
Instrument TypePortable Multiparameter Water Quality Analyzer
DO (Air Saturation)0–500%, Resolution: 0.1%, Accuracy: ±2% or ±2% air saturation (0–200%), ±6% (200–500%)
DO (mg/L)0–50 mg/L, Resolution: 0.01 mg/L, Accuracy: ±2% or ±0.2 mg/L (0–20 mg/L), ±6% (20–50 mg/L)
Temperature−5 to +45 °C, Resolution: 0.1 °C, Accuracy: ±0.15 °C
Conductivity0–200 mS/cm, Resolution: 0.001–0.1 mS/cm (range-dependent), Accuracy: ±0.5% or ±0.001 mS/cm (4-m cable), ±1.0% or ±0.001 mS/cm (20-m cable)
Salinity0–70 ppt, Resolution: 0.01 ppt, Accuracy: ±1.0% or ±0.1 ppt
pH (optional)0–14, Resolution: 0.01, Accuracy: ±0.2
ORP (optional)−999 to +999 mV, Resolution: 0.1 mV, Accuracy: ±20 mV
TDS0–100 g/L, Resolution: 4-digit
Barometer (optional)500–800 mmHg, Resolution: 0.1 mmHg, Accuracy: ±3 mmHg (within ±15 °C of calibration temperature)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
Model6820 / 6920
Dissolved Oxygen (DO)0–500% air saturation (±2% or 2% of reading, whichever is greater, for 0–200%
Conductivity0–100 mS/cm (±0.5% + 0.001 mS/cm)
Temperature−5 to 50 °C (±0.15 °C)
pH0–14 (±0.2)
ORP−999 to +999 mV (±20 mV)
Salinity0–70 ppt (±1.0% or 0.1 ppt, whichever is greater)
Depth (Shallow)0–9 m (±0.018 m)
Depth (Medium)0–61 m (±0.12 m)
Barometric Pressure-Compensated Water Level0–9 m (±0.003 m)
Turbidity0–1000 NTU (±2% or 0.3 NTU, whichever is greater)
Chlorophyll-a0–400 µg/L (detection limit: 0.1 µg/L
Rhodamine WT0–200 µg/L (±5% or 1 µg/L, whichever is greater)
Ammonia/Nitrate (Freshwater only)0–200 mg N/L (±10% or 2 mg N/L, whichever is greater)
Chloride (Freshwater only)0–1000 mg/L (±15% or 5 mg/L, whichever is greater)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelDO200
Instrument TypePortable
Temperature Measurement PrincipleThermistor (10 kΩ @ 25 °C)
Temperature Range–6 to +46 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C ±1 LSD
DO (% Air Saturation) PrincipleSteady-State Polarographic (PE Membrane)
DO (% AS) Range0–200 %
DO (% AS) Resolution0.1 %
DO (% AS) Accuracy±2 % of reading or ±2 % air saturation, whichever is greater
DO (mg/L) PrincipleSteady-State Polarographic (PE Membrane)
DO (mg/L) Range0–20 mg/L
DO (mg/L) Resolution0.01 mg/L
DO (mg/L) Accuracy±2 % of reading or ±0.2 mg/L, whichever is greater
Enclosure RatingIP65
CompensationAutomatic temperature compensation
Membrane TypeNext-generation fast-response, low-stirring-dependency PE membrane
Cable Options4 m or 10 m
Probe ConstructionStainless steel sensor with protective polymer sheath
ConnectorStrain-relieved cable interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI ROX
Measurement PrincipleFluorescence Lifetime Detection
DO Range (Air Saturation)0–500%
Resolution (Air Saturation)0.1%
Accuracy (0–200%)±1% of reading or ±1% air saturation, whichever is greater
Accuracy (200–500%)±15% of reading
DO Range (mg/L)0–50 mg/L
Resolution (mg/L)0.01 mg/L
Accuracy (0–20 mg/L)±1% of reading or ±0.1 mg/L, whichever is greater
Accuracy (20–50 mg/L)±15% of reading
Membrane LifeUp to 12 months
Flow IndependenceYes
Zero-Point CalibrationSupported
H₂S ResistanceYes
CompatibilityFully compatible with YSI ProDSS and EXO platforms (via optical port), YSI 6-Series multiparameter sondes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelFDO
Measurement PrincipleFluorescence-based (dynamic quenching)
Detection ParameterDissolved Oxygen (DO)
Instrument TypeOnline Water Quality Analyzer
ComplianceDesigned for continuous monitoring in wastewater treatment and environmental applications
CalibrationFactory-calibrated smart sensor with embedded calibration chip (IQMC)
Optical SystemDual-path EPRS (Equal Path Reference System)
Light SourceGreen LED (GLT technology)
Sensor Geometry45° beveled tip for bubble rejection
Operating EnvironmentAqueous media, activated sludge, surface water, and effluent streams
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelMPP IDS
Instrument TypePortable Multi-Parameter Water Quality Sensor
Measurable ParameterspH / ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity
Probe InterfaceDigital IDS (Intelligent Digital Sensor) interface supporting up to three simultaneous IDS-compatible probes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXylem
OriginUSA
ModelYSI ProDSS
Instrument TypePortable/Handheld Water Quality Analyzer
Sensor Interface4x Smart Sensor Ports
DisplayHigh-Resolution Color LCD
Depth RatingIP67 (submersible to 1 m for 30 min)
Cable OptionsUp to 100 m (with or without integrated depth sensor)
PowerRechargeable Lithium-Ion Battery
GPSOptional Integrated Module
ComplianceDesigned for ASTM D3370, ISO 5814, ISO 7888, USP <643>, EPA Method 180.1, and GLP-compliant field data collection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelAlyza IQ
Instrument TypeOnline Analyzer
Measurement PrincipleColorimetric Method
Measurement Range0.02–20 mg/L NH₄–N
Detection Limit0.02 mg/L
AccuracyMR1: ±2% ±0.02 mg/L (0.02–5 mg/L)
MR2±3% ±0.10 mg/L (0.1–20 mg/L)
IntegrationFully compatible with IQ Sensor Net platform (supports IQ System 2020, 282, and 284)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelMIQ/TC 2020 3G
Instrument TypeOnline Water Quality Analyzer
Measured ParameterspH/ORP, Temperature, Dissolved Oxygen (DO), Conductivity, Turbidity, Sludge Concentration, COD/BOD/TOC/DOC/SAC/UVT, Ammonia-N, Nitrate-N, Nitrite-N, Sludge Interface, Phosphate
Max Sensor Channels20
Analog Outputs & Relaysup to 48
Max Total Cable Length1000 m
Data Storage Capacity526,600 records
Enclosure RatingIP66
Communication ProtocolsPROFIBUS-DP, MODBUS RTU, Ethernet/IP, MODBUS TCP, PROFINET
USB InterfaceData export & password-protected system unlock via USB key
Optional Remote ConnectivityGSM/Analog modem, Wireless module
Calibration SupportIQ-LabLink intelligent calibration system
Surge ProtectionIntegrated lightning protection
RedundancyStandby controller functionality with automatic failover to MIQ/CM3 display unit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
Model VariantsPB-S/1, PB-S/R12, PB-S/R24
Housing MaterialStainless Steel (IP65-rated)
Sampling Control ModesTime-based & Event-triggered
Sample PreservationIntegrated Cooling/Heating Module
Sample Volume Accuracy±1.5% of set volume (vacuum-driven aspiration)
Operating Environment-20 °C to +50 °C
Power Supply100–240 V AC, 50/60 Hz
ComplianceEN ISO 5667-10, ASTM D3370, EPA Method 1664
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelTetraCon LR
Measurement Principle4-Electrode Conductivity
Range1 µS/cm to 2 S/cm
Minimum Resolution0.01 µS/cm (dependent on transmitter)
Electrode ConstantK = 0.475 cm⁻¹ (standard), adjustable range 0.475–1.008 cm⁻¹
Temperature CompensationBuilt-in, -5 °C to +60 °C
Pressure Rating10 bar (20 °C)
Accuracy±2% of reading ±1 µS/cm at 25 °C
Response Time (t₉₀)<20 s
ComplianceISO 7888, ASTM D1125, DIN EN 27888
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 85
Probe TypeIntegrated (YSI 85) or Replaceable D-Series (YSI 85D)
DO Range0–200% air saturation / 0–20 mg/L
DO Accuracy±2% air saturation or ±0.3 mg/L
Conductivity Ranges0–499.9 µS/cm, 0–4999 µS/cm, 0–49.99 mS/cm, 0–200.0 mS/cm
Conductivity Accuracy±0.5% of reading per range
Salinity Range0–80 ppt
Salinity Accuracy±2% or ±0.1 ppt
Temperature Range–5 to +65 °C
Temp Accuracy±0.1 °C (±1 lsd)
ResolutionDO: 0.1% sat / 0.01 mg/L
Cond0.1 µS/cm to 0.1 mS/cm (range-dependent)
Salinity0.1 ppt
Temp0.1 °C
Data Storage50 readings (non-volatile memory)
DisplayBacklit LCD
EnclosureIP67-rated housing (YSI 85D with MS connector)
ComplianceDesigned for ASTM D888, ISO 5814, USP <781>, EPA Method 4500-O G
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0