BrandYSI
OriginUSA
ModelYSI 58
TypePortable
Measurement PrincipleClark-type polarographic electrode
DO Range (mg/L)0–20 mg/L
DO Resolution (mg/L)0.01 mg/L
DO Accuracy (mg/L)±0.03 mg/L
DO Range (% air saturation)0–200%
DO Resolution (% sat)0.1%
DO Accuracy (% sat)±0.3%
Temperature Range−5 to +45 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C
Temp Compensation Range0 to +45 °C
Salinity Compensation Range0–40 ppt
Salinity Compensation Accuracy±0.3% of compensated reading ±1 digit
Recorder Output0–1 V DC (0.5 V = 1 digit), ±0.4% full scale ±1 least significant digit, min. load 50 kΩ
Power4 × D-cell batteries (Zn-C or alkaline), ~1000 h life
Dimensions21.6 × 28.0 × 9.5 cm
Weight1.90 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelDO200
Instrument TypePortable
Temperature Measurement PrincipleThermistor (10 kΩ @ 25 °C)
Temperature Range–6 to +46 °C
Temperature Resolution0.1 °C
Temperature Accuracy±0.3 °C ±1 LSD
DO (% Air Saturation) PrincipleSteady-State Polarographic (PE Membrane)
DO (% AS) Range0–200 %
DO (% AS) Resolution0.1 %
DO (% AS) Accuracy±2 % of reading or ±2 % air saturation, whichever is greater
DO (mg/L) PrincipleSteady-State Polarographic (PE Membrane)
DO (mg/L) Range0–20 mg/L
DO (mg/L) Resolution0.01 mg/L
DO (mg/L) Accuracy±2 % of reading or ±0.2 mg/L, whichever is greater
Enclosure RatingIP65
CompensationAutomatic temperature compensation
Membrane TypeNext-generation fast-response, low-stirring-dependency PE membrane
Cable Options4 m or 10 m
Probe ConstructionStainless steel sensor with protective polymer sheath
ConnectorStrain-relieved cable interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI ROX
Measurement PrincipleFluorescence Lifetime Detection
DO Range (Air Saturation)0–500%
Resolution (Air Saturation)0.1%
Accuracy (0–200%)±1% of reading or ±1% air saturation, whichever is greater
Accuracy (200–500%)±15% of reading
DO Range (mg/L)0–50 mg/L
Resolution (mg/L)0.01 mg/L
Accuracy (0–20 mg/L)±1% of reading or ±0.1 mg/L, whichever is greater
Accuracy (20–50 mg/L)±15% of reading
Membrane LifeUp to 12 months
Flow IndependenceYes
Zero-Point CalibrationSupported
H₂S ResistanceYes
CompatibilityFully compatible with YSI ProDSS and EXO platforms (via optical port), YSI 6-Series multiparameter sondes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 52
DO (Air Saturation)0.0–199.9%
Resolution0.1% air saturation
Accuracy±0.1% air saturation + 1 LSD
DO (mg/L)0.0–19.99 mg/L
Resolution0.01 mg/L
Accuracy±0.03 mg/L
Temperature Range−5 to +45 °C
Resolution0.1 °C
Accuracy±0.1 °C
Temp Compensation Range0 to +45 °C
Salt Compensation Range0–40 ppt
Resolution0.01 ppt
Accuracy±1.0% of reading or ±0.1 ppt (whichever is greater)
Data Storage70 non-volatile memory records (DO, temp, date, time)
IP Rating>IP65
Power6 × D-cell alkaline batteries (typical life: 100 h)
Dimensions21.6 × 28.0 × 9.5 cm
Weight2.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandXylem
OriginUSA
ModelYSI Pro20
Instrument TypePortable
Measurement PrinciplePolarographic & Galvanic (User-Selectable Sensor Types)
DO Range0–50 mg/L
Accuracy±2% of reading (0–20 mg/L) or ±0.2 mg/L, whichever is greater
Repeatability±2%
Detection Limit0.1 mg/L
Temperature Range–5 to 55 °C
Temp Accuracy±0.3 °C
Barometric Pressure Range53–133 kPa
Pressure Accuracy±0.4 kPa (within ±15 °C of calibration temperature)
Salinity Compensation0–70 ppt (manual input, automatic compensation)
Data Storage50 datasets with timestamp
IP RatingIP67
Drop Test1-meter drop resistance
CertificationsRoHS, CE, WEEE
Warranty3 years (instrument), 2 years (cable), 1 year (polarographic sensor), 6 months (galvanic sensor)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYSI
OriginUSA
ModelYSI 550A
Instrument TypePortable
IP RatingIP67
Measurement PrinciplePolarographic (Clark-type) Electrode with Thermistor Temperature Compensation
DO Range0–50 mg/L (0–500% air saturation)
Temperature Range–5 to +45 °C
DO Accuracy±2% or ±2% air saturation (0–200%), ±6% (200–500%)
Temp Accuracy±0.3 °C
Resolution0.01/0.1 mg/L (selectable), 0.1 °C, 0.1/1% air saturation (selectable)
Battery LifeUp to 2000 hours
Cable Options3.7 m, 7.5 m, 15 m, 30 m
CalibrationBuilt-in DO calibration chamber, automatic temperature compensation, manual salinity & altitude compensation