- All
- Favorite
- Popular
- Most rated
| Brand | COULBOURN |
|---|---|
| Origin | USA |
| Model | AASS |
| Sound Output Range | 20 Hz – 25.5 kHz (audio), 20 Hz – 20 kHz (white noise) |
| Max SPL | 128 dB |
| Stimulus Control | Computer-controlled amplitude, frequency, duration, rise/fall time |
| Optional Modules | Footshock (up to 3.0 mA), Visual Flash Stimulus |
| Chamber Configuration | Single or 8-chamber sound-attenuated enclosures |
| Data Acquisition | Analog signal conditioning (amplification + integration), 16-bit ADC |
| Compliance | Designed for GLP-compliant behavioral phenotyping workflows |
| Brand | BLS |
|---|---|
| Origin | Hungary |
| Model | CF-150C |
| Pulse Voltage Range (Square Wave) | 12–185 V |
| Pulse Duration | 10–200 µs |
| Inter-Pulse Interval | 200 µs |
| Pulse Count | 1–10 |
| HF Oscillator Frequency | 1 MHz ±100 Hz |
| HF Amplitude (Coarse) | 0–30 V<sub>eff</sub> |
| HF Amplitude (Fine) | 0–3 V<sub>eff</sub> |
| Operating Medium | Electrolytic or Non-electrolytic Solutions |
| Dimensions | 200 × 130 × 45 mm |
| Weight | 380 g |
| Power Consumption | 15 VA |
| Protection Class | Class I (Earthed) |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | BTX Model 524 |
| Electrode Type | Reusable tweezer-style in vivo electroporation electrode |
| Electrode Disk Diameter Options | 7 mm (Model 520) or 10 mm (Model 523) |
| Adjustable Inter-Electrode Gap | <1 mm to >20 mm |
| Compatible Pulse Generators | BTX ECM 830, ECM 630, ECM T820, ECM 2001 |
| Electrode Material | Stainless steel |
| Sterilization Method | Ethanol or ethylene oxide |
| Connection | BTX Model 524 Cable |
| Compliance | Designed for GLP-compliant preclinical research workflows |
| Brand | BLS |
|---|---|
| Origin | EU-manufactured |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | European Union |
| Model | CF150B |
| Pricing | Available upon Request |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | PLI-10 |
| Input Pressure Range | 480–720 kPa (70–105 psi) |
| Output Pressure Range | 2.8–413 kPa (0.2–60 psi), continuously adjustable |
| Pulse Width Resolution | 10 ms (0.01–0.99 s) |
| Injection Count Display | 0–9999 (digital LED) |
| Trigger Modes | Front-panel knob, foot switch, external TTL pulse via BNC input |
| Operating Mode | Timed pulse or continuous gate-controlled duration |
| Pressure Release | Multi-turn manual regulator with bidirectional control |
| Compliance | Designed for GLP-compliant electrophysiology and microinjection workflows |
| Brand | BLS |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | Custom Camera Filter |
| Pricing | Available Upon Request |
| Filter Types | FS/CEF-1C2, FS/CEF-2G2, FS/CEF-3GY2, FS/CEF-3GY1, FS/CEF-4Y3, FS/CEF-4Y2, FS/CEF-4Y1, FS/CEF-4R2, FS/CEF-4O2 Emission Filters |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | SurgiVet V6004 |
| Pricing | Available Upon Request |
| Brand | HEKA (now part of Harvard Bioscience) |
|---|---|
| Origin | Germany (manufactured in Lambrecht, Germany |
| Model | EPC 10 USB |
| Architecture | Integrated analog amplifier + digital I/O (LIH 8+8 AD/DA interface) |
| Interface | High-speed USB 2.0 |
| Configurations | Single-, dual-, triple-, and quad-patch headstage options |
| Compatible Software | PatchMaster v2.x / PatchMaster Next, FitMaster, SmartLux |
| Compliance | CE-marked, RoHS-compliant, designed for GLP/GMP-adjacent electrophysiology labs |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | RWD Standard Stereotaxic Instrument |
| Price Range | USD 7,000 – 14,000 |
| Frame Design | U-shaped rigid cast aluminum architecture |
| Motion Axes | X/Y/Z with 80 mm travel per axis |
| Positioning Resolution | 100 µm (micrometer-scale vernier scale) |
| Rotation Capability | 360° horizontal azimuthal rotation, 180° vertical elevation adjustment with mechanical locking |
| Scale Marking | Laser-etched dual-scale graduations (mm and 0.1 mm) |
| Drive Mechanism | Dual-lead precision brass-on-steel micrometer screws |
| Surface Treatment | Anodized aluminum frame and base plate for wear resistance and autoclave-compatible cleanability |
| Animal Adapter | Curved craniomandibular contour design for rat skull conformity |
| Ear Bar Fixation | Dual-side compression plate locking system |
| Compatibility | Integrated mounting interfaces for microinjection pumps (e.g., RWD KDS200 series), stereomicroscopes (Leica MZ10F, Olympus SZX16), and cranial drill systems (RWD 60000 series) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Table Top |
| Gas Delivery System | Non-rebreathing, single-circuit |
| Vaporizer Type | TECH3 Isoflurane/Sevoflurane |
| Flow Range | 0–1000 mL/min (O₂) |
| Vapor Output Range | 0.5–5% |
| Weight | ~10 kg (unit + vaporizer) |
| Safety Features | Vaporizer lockout, visual drug level window, activated carbon scavenging system |
| Compliance | ASTM F2749-22 (Anesthetic Equipment), ISO 80601-2-13:2021 (Medical Electrical Equipment – Particular Requirements for Anesthetic Workstations) |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | MM-33 |
| Control Type | Manual |
| Coarse Adjustment Range (X/Y/Z) | 37 mm / 20 mm / 20 mm |
| Coarse Resolution | 0.1 mm per axis |
| Fine Adjustment Range (X) | 10 mm |
| Fine Resolution | 0.01 mm |
| Rotational Base | Lockable, Dual-Axis (Horizontal & Vertical) |
| Mounting Compatibility | Magnetic base, standard dovetail or clamp-style stage adapters |
| Intended Use | Electrophysiology, patch-clamp, microinjection, and extracellular stimulation |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | IPA |
| Type | Integrated Electrophysiology Amplifier System with Built-in ADC/DAC |
| Compliance | Designed for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings |
| Software | SutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving) |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 38450 |
| Force Range | 0–1000 g |
| Force Resolution | 0.1 g |
| Observation System | Integrated Triangular Prism Viewing Platform |
| Data Storage | Onboard memory for >100 test sessions |
| Stimulus Control | User-adjustable ramp rate and inter-stimulus interval |
| Compliance | Designed for GLP-compliant rodent nociception studies |
| Accessories | Optional grip bar, mesh floor platform (5 × 5 mm² laser-cut apertures, 1 mm spacing), calibrated von Frey filament sets (37450/277, 0.008–300 g) |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | Gemini SC2 |
| Waveforms | Square Wave & Exponential Decay Wave |
| Voltage Range (LV) | 5–500 V (1 V step), 505–3000 V (5 V step) |
| Voltage Range (HV) | 10–500 V (5 V step), 510–3000 V (10 V step) |
| Pulse Duration (Square, LV) | 10 µs–999 µs (1 µs), 1 ms–999 ms (1 ms) |
| Pulse Duration (Square, HV) | 10 µs–600 µs (1 µs) |
| Pulse Duration (Exponential, LV) | 1.25 ms–3.275 s (1.25 ms) |
| Pulse Duration (Exponential, HV) | 0.5 ms–50 ms (0.5 ms) |
| Pulse Number (Square) | 1–10 (LV), 1–3 (HV) |
| Pulse Number (Exponential) | 1–12 (R < 100 Ω), 1–24 (R > 100 Ω) |
| Pulse Interval | 0.1–10 s (Square), 5–30 s (Exponential) |
| Capacitance (LV) | 3775 µF (fixed) |
| Capacitance (HV) | 85 µF (fixed) |
| Capacitance (Exponential, LV) | 25–3275 µF (25 µF step) |
| Capacitance (Exponential, HV) | 10, 25, 50 µF (selectable) |
| Resistance Measurement Range | 25–1575 Ω (25 Ω step, LV) |
| Display | Touchscreen Interface |
| Preloaded Protocols | Yes |
| Arc Suppression | Active |
| Short-Circuit Protection | Integrated |
| Compliance | CE, RoHS, FDA-listed device (Class II) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Nanoliter2000 |
| Pricing | Upon Request |
| Brand | Ugo Basile |
|---|---|
| Origin | Italy |
| Model | 33 or 33T |
| Light Source Intensity Range | 0–250 (arbitrary units, ±1% accuracy) |
| Focal Spot Size | 4 × 6 mm |
| Reaction Time Resolution | 0.01 s |
| Preheating Temperature Range | 0–75 °C |
| Automatic Cut-off Timer | User-configurable |
| Data Output | RS-232 serial interface + thermal printer support |
| Compliance | Designed for GLP-compliant preclinical analgesia studies |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | AS-01-006 |
| Oxygen Inlet Pressure | 50 PSI (fixed) |
| Max Oxygen Flow | 50 LPM (safety-limited) |
| Adjustable O₂ Flow Range | 0–4 LPM |
| Isoflurane Vaporizer Range | 0.5–5.0% |
| CO₂ Absorber Capacity | 3 lb (1.36 kg) |
| Dimensions (L×W×H) | 40 × 35.5 × 85 cm |
| Compliance | ASTM F2739, ISO 80601-2-13, USP <1211>, GLP-ready design |
| Brand | Harvard Apparatus |
|---|---|
| Origin | USA |
| Model | CDS 9000 |
| Certification | CE, ISO 13485 |
| Gas Flow Range | 0.2–4 L/min (O₂) |
| Vaporizer | Original 100 Series or TECH3 Isoflurane Vaporizer (≥250 mL, output accuracy ±0.5%) |
| CO₂ Absorbent Canister Capacity | ≥900 mL |
| Pressure Gauge Range | 0–60 cm H₂O |
| Circuit Type | Dual-path F-circuit with integrated Pop-off valve (2 cm H₂O constant negative pressure) |
| Construction | Anodized matte-finish aluminum chassis |
| Compliance | FDA-recognized materials (NASA-derived loop board), USP <1210> compatible design |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Amani-650 |
| Pricing | Available Upon Request |
| [Origin | Denmark |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 111P |
| Price | Upon Request |
| Vessel Diameter Range | >60 µm |
| Tension Range | ±50 mN |
| Tension Resolution | 0.01 mN |
| Pressure Range | 0–250 mmHg |
| Pressure Accuracy | ±0.1 mmHg |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.1 °C |
| Bath Volume | Up to 10 mL (3 mL standard) |
| Bath Material | Acid-Resistant Stainless Steel |
| Heating | Integrated Electronic Feedback Control |
| Analog Output | 1.0 V F.S. (12-bit) |
| Digital Interface | RS232 / RS485 |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Environmental Operating Temp | 15–30 °C] |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | P-97 |
| Type | Horizontal Programmable Micropipette Puller |
| Heating Mechanism | Dual-Independent Filament (Tungsten/Platinum) |
| Control Architecture | Microprocessor-Based with Ramp Detection Algorithm |
| Program Storage | 100 User-Defined Protocols with Write-Protection and Timestamping |
| Electrode Symmetry | Dual-Output Symmetric Pulling |
| Tip Diameter Reproducibility | Sub-100 nm (verified by SEM) |
| Integrated Gas System | Regulated Compressed Air with Particulate Filter, Desiccant Dryer, and Humidity Stabilization |
| Display | Vacuum Fluorescent Display (VFD) with Real-Time Parameter Monitoring |
| Compliance | Designed for GLP/GMP-aligned electrophysiology workflows |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 454 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | LabLincV |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | C76688 |
| Pricing | Available Upon Request |
Show next