Empowering Scientific Discovery

PerkinElmer Spectrum ONE FTIR Spectrometer (Refurbished)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin USA
Model Spectrum ONE
Instrument Type Fourier Transform Infrared (FTIR) Spectrometer
Age 3–4 years
Warranty 6 months
Configuration Includes Spectrum ONE main unit, Spectrum Spotlight FTIR Imaging System, and dedicated PC with proprietary software
Compliance Fully refurbished and performance-verified per ASTM E1421–22 standard for FTIR instrument qualification
Software Spectrum v6.x (with full license transfer eligibility)
Detector Dual-channel DTGS/KBr beam splitter configuration
Spectral Range 4000–400 cm⁻¹ (standard)
Resolution Adjustable down to 0.5 cm⁻¹
Scan Speed Up to 20 kHz mirror velocity
Data Format Compatible with JCAMP-DX, ASCII, and HDF5 export

Overview

The PerkinElmer Spectrum ONE FTIR Spectrometer is a rigorously refurbished, benchtop Fourier Transform Infrared spectrometer engineered for high-fidelity molecular fingerprinting across research, quality control, and regulatory environments. Based on Michelson interferometry with patented DynaScan™ moving-mirror scanning technology, it delivers exceptional optical stability, signal-to-noise ratio (>35,000:1 at 4 cm⁻¹, 1 min scan), and long-term spectral reproducibility. Designed for operational continuity in ISO 17025-accredited labs and GMP-compliant facilities, the Spectrum ONE integrates a thermally stabilized optical bench, sealed interferometer housing, and real-time internal reference laser tracking (HeNe, 632.8 nm) to ensure wavelength accuracy within ±0.02 cm⁻¹ over extended duty cycles. Its modular architecture supports seamless integration of transmission, ATR, diffuse reflectance, and gas cell accessories — all auto-recognized via embedded EEPROM identification.

Key Features

  • Patented DynaScan™ interferometer with dynamic alignment compensation, eliminating manual recalibration between sessions
  • Dual-detector capability (DTGS and optional MCT) with automatic detector switching and gain optimization
  • Intelligent accessory recognition: Each PerkinElmer-certified module (e.g., Universal ATR, Specac Golden Gate) self-reports calibration parameters and measurement history upon insertion
  • Onboard diagnostics suite with continuous monitoring of laser intensity, mirror position error, and beam deviation; alerts trigger before data degradation occurs
  • Thermally isolated optical path with active temperature stabilization (±0.1°C) to minimize drift during multi-hour acquisition sequences
  • Pre-aligned, factory-qualified optical train — no user collimation required during installation or relocation

Sample Compatibility & Compliance

The Spectrum ONE accommodates solid, liquid, and gaseous samples via standardized interfaces compliant with ASTM E1252 (general IR sampling), ASTM E168 (qualitative analysis), and USP <197> (pharmaceutical identity testing). Its integrated Spotlight imaging module enables spatially resolved chemical mapping at 10–25 µm pixel resolution across 10 × 10 mm fields of view, supporting ICH Q5E comparability assessments and polymer phase distribution analysis. All refurbished units undergo full IQ/OQ protocol execution per manufacturer-recommended procedures, including linearity verification (NIST-traceable polystyrene film), photometric accuracy (KBr pellet standards), and wavenumber repeatability (±0.01 cm⁻¹ RMS over 24 h). Documentation includes Certificate of Performance Verification, traceable calibration records, and compliance summary aligned with FDA 21 CFR Part 11 audit trail requirements.

Software & Data Management

Controlled by PerkinElmer Spectrum v6.x software (licensed for transfer), the system provides validated workflows for quantitative analysis (PLS, PCA), spectral library searching (Sadtler, BioRad, and custom libraries), and automated peak identification. The software architecture supports electronic signatures, user role-based access control (admin/operator/analyst), and immutable audit trails meeting GLP/GMP data integrity criteria. Raw interferograms and processed spectra are stored in HDF5 format with embedded metadata (instrument ID, operator, date/time, environmental conditions), enabling traceability from acquisition through reporting. Export modules support LIMS integration via ASTM E1384-compliant XML schema and direct import into MATLAB, Python (SciPy), or Thermo Fisher Omnic platforms.

Applications

  • Pharmaceutical raw material identification and polymorph screening per USP <197> and EP 2.2.24
  • Failure analysis of polymeric packaging components (delamination, oxidation, additive migration)
  • Forensic fiber and paint chip characterization using spectral subtraction and hierarchical clustering
  • Quality assurance of catalysts and battery electrode materials via in-situ DRIFTS under controlled atmosphere
  • Microplastic identification in environmental matrices using focal plane array (FPA) imaging coupled with chemometric classification
  • Educational laboratories requiring robust, low-maintenance FTIR platforms with pedagogical workflow templates

FAQ

Is this instrument eligible for FDA 21 CFR Part 11 compliance?
Yes — the included Spectrum v6.x software supports electronic signatures, audit trails, and role-based permissions. Full validation documentation is provided upon request.
What refurbishment standards are applied prior to shipment?
Each unit undergoes optical realignment, detector responsivity recalibration, interferometer vacuum integrity testing, and full functional verification against PerkinElmer’s OEM acceptance criteria (documented in IQ/OQ report).
Can the Spotlight imaging module be upgraded to FPA detection?
Yes — the Spotlight platform is mechanically and electronically compatible with optional 128 × 128 or 256 × 256 MCT FPA detectors; upgrade paths are available with technical consultation.
Does the 6-month warranty cover labor and parts globally?
Warranty covers parts and labor for defects in materials or workmanship. On-site service is available in North America, EU, and APAC regions via authorized PerkinElmer service partners.
Are original manuals and software installation media included?
Digital copies of all user manuals, application notes, and software installers are provided. Physical media is not shipped; secure download links with license keys are issued post-purchase.