Empowering Scientific Discovery

Shimadzu GC-2010 Used Gas Chromatograph

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Shimadzu
Origin Japan
Manufacturer Type Authorized Distributor
Origin Category Imported
Model GC-2010
Price Range USD 4,200 – 7,000 (FOB)
Instrument Type Laboratory Gas Chromatograph

Overview

The Shimadzu GC-2010 is a high-performance, benchtop gas chromatograph engineered for precision separation and quantitative analysis of volatile and semi-volatile organic compounds. Based on robust capillary column technology and temperature-programmed oven control, the GC-2010 employs flame ionization detection (FID), thermal conductivity detection (TCD), or electron capture detection (ECD) configurations—depending on system configuration—to deliver high sensitivity, reproducibility, and retention time stability. Designed and manufactured in Japan, the instrument adheres to Shimadzu’s stringent quality standards for analytical instrumentation and is widely deployed in regulated laboratory environments including pharmaceutical QC, environmental monitoring, food safety testing, and academic research. Its modular architecture supports dual-column, dual-detector operation and integrates seamlessly with Shimadzu’s Class-GC software for method development, data acquisition, and report generation.

Key Features

  • Temperature-controlled oven with programmable ramp rates (0.1–60 °C/min) and precise isothermal hold capability (±0.01 °C stability)
  • Electronic pressure control (EPC) for carrier gas (He, H2, N2) with real-time flow optimization and retention time locking
  • Split/splitless injection system with adjustable liner geometry and cool-on-column (COC) compatibility
  • Auto-sampler interface support (e.g., AOC-20i or AOC-5000+) enabling unattended multi-sample analysis
  • Modular detector options: FID (detection limit ≤ 3 pg C/sec), TCD (universal detection), ECD (halogen-selective, sub-pg sensitivity)
  • Compliant with ISO/IEC 17025 calibration traceability requirements when operated with certified reference standards and documented SOPs

Sample Compatibility & Compliance

The GC-2010 accommodates a broad range of sample matrices—including aqueous extracts, organic solvent solutions, headspace vapors, and thermal desorption tubes—when paired with appropriate sample introduction modules (e.g., purge-and-trap, thermal desorption units, or pyrolyzers). It supports capillary columns up to 60 m in length and internal diameters from 0.10 to 0.53 mm, compatible with standard stationary phases (e.g., DB-5ms, HP-INNOWAX, DB-VRX). The system meets key regulatory framework prerequisites for routine use in GLP- and GMP-compliant laboratories: audit trail functionality (via Class-GC software), electronic signature support per FDA 21 CFR Part 11 (when validated), and alignment with ASTM D3699 (gasoline hydrocarbons), EPA Method 8260C (VOCs in water), and USP <621> (chromatography system suitability).

Software & Data Management

Class-GC software provides full instrument control, peak integration, calibration curve generation (linear, quadratic, or weighted), and customizable reporting templates compliant with LIMS export formats (e.g., CSV, XML, PDF/A-1a). Data files are stored in proprietary .GCW format with embedded metadata (instrument parameters, operator ID, timestamp, method version), ensuring integrity and traceability. Audit trail logs record all user actions—including method edits, reprocessing events, and calibration updates—with immutable timestamps. Optional integration with LabSolutions software enables cross-platform data comparison with Shimadzu LCMS or UV-Vis systems, supporting unified workflow management across hyphenated techniques.

Applications

  • Pharmaceutical impurity profiling and residual solvent quantification per ICH Q2(R2) guidelines
  • Environmental analysis of pesticides, PCBs, PAHs, and chlorinated hydrocarbons in soil/water per EPA SW-846 methods
  • Fatty acid methyl ester (FAME) profiling in biodiesel and edible oils (AOCS Ce 1h-05)
  • Volatile organic compound (VOC) screening in indoor air and packaging materials (ISO 16000-6)
  • Quality control of petrochemical feedstocks and finished fuels (ASTM D5504, D6729)
  • Forensic toxicology screening for ethanol, methanol, and acetone in biological fluids

FAQ

Is the GC-2010 compatible with modern data systems and LIMS?
Yes—the instrument supports standard RS-232, USB, and Ethernet connectivity; Class-GC exports results in comma-separated values (CSV), XML, and PDF formats, enabling direct ingestion into most LIMS platforms.
What documentation is provided with a refurbished GC-2010 unit?
Each unit undergoes functional verification per Shimadzu’s OEM service checklist and includes a Certificate of Inspection, as-found/as-left performance test report, and full service history (where available). Calibration certificates are issued traceable to NIST standards.
Can the GC-2010 be upgraded with newer detectors or automation modules?
Yes—original Shimadzu accessories (e.g., FID-2010+, AOC-20i autosampler, SIL-20AC injector) remain fully compatible; firmware updates and hardware retrofits are supported via authorized service channels.
Does this used instrument meet current regulatory compliance expectations?
When installed, qualified, and maintained according to manufacturer-recommended protocols—and operated under validated methods—it satisfies baseline requirements for ISO/IEC 17025, CLIA, and FDA-regulated environments. Full 21 CFR Part 11 compliance requires additional validation documentation and IT infrastructure controls.
What is the typical lead time for installation and operational qualification (IQ/OQ)?
Standard IQ/OQ packages—including site assessment, mechanical/electrical verification, system suitability testing, and user training—are typically completed within 5–10 business days post-delivery, depending on lab readiness and scope of qualification protocol.

InstrumentHive