Copper Strip Corrosion Tester for Liquefied Petroleum Gas (LPG) – PULUODY PLD-0232A
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0232A |
| Temperature Control Range | 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Timing Range | 0–100 min (user-adjustable) |
| Power Supply | AC 220 V |
| Max. Power Consumption | 1200 W |
| Construction | Stainless Steel Bath & Lid |
| Compliance | SH/T 0232 |
Overview
The PULUODY PLD-0232A Copper Strip Corrosion Tester is a precision-engineered laboratory instrument designed specifically for evaluating the corrosivity of liquefied petroleum gas (LPG) toward copper, in strict accordance with the Chinese national standard SH/T 0232—“Test Method for Copper Strip Corrosion by Liquefied Petroleum Gases”. This test method is based on the principle of exposing a standardized polished copper strip to vapor-phase LPG under controlled temperature and time conditions, followed by visual comparison of the resulting discoloration or tarnish against the ASTM D130 copper corrosion rating scale. The PLD-0232A provides a reproducible, thermally stable environment essential for achieving inter-laboratory consistency in corrosion assessment—a critical parameter for quality control in LPG refining, storage, transportation, and end-use applications.
Key Features
- Stainless steel constant-temperature water bath and lid ensure long-term resistance to oxidation and chemical degradation, maintaining structural integrity and thermal uniformity over repeated operational cycles.
- Dual-slot configuration supports up to two copper strip test cylinders simultaneously, enabling parallel testing or comparative analysis without cross-contamination or thermal interference.
- High-precision digital PID temperature controller with auto-tuning capability delivers stable thermal regulation at the specified test temperature of 40 °C (±0.5 °C), minimizing drift during extended exposure periods.
- Programmable digital timer (0–100 minutes) with audible alert ensures precise adherence to SH/T 0232 exposure durations and eliminates manual timing errors.
- Integrated mechanical design unifies the bath, cylinder mounting fixtures, and cover assembly into a compact, rigid platform—reducing vibration sensitivity and enhancing operator safety.
- Dedicated accessory hooks securely hold test cylinders, crescent wrenches, and polishing tools, supporting organized workflow and compliance with GLP-aligned laboratory housekeeping practices.
Sample Compatibility & Compliance
The PLD-0232A is validated exclusively for vapor-phase copper strip corrosion testing of commercial LPG streams containing propane, butane, and their blends. It accommodates standard ASTM D130-compliant copper strips (19 × 12.7 × 1.5 mm), pre-polished per SH/T 0232 requirements. All thermal and temporal operating parameters align with SH/T 0232’s procedural mandates—including immersion depth, vapor saturation time, and post-test evaluation window. While SH/T 0232 is the primary reference, results generated using this instrument are technically comparable to those obtained under ASTM D130 and ISO 6251, facilitating international data exchange in refinery QA/QC reporting. The unit does not require regulatory certification under FDA 21 CFR Part 11; however, its digital timer and temperature logging interface (when paired with optional external data acquisition modules) support audit-ready documentation for ISO/IEC 17025-accredited laboratories.
Software & Data Management
The PLD-0232A operates as a standalone hardware system with embedded digital controls—no proprietary software installation is required. Temperature setpoint, real-time bath temperature, and elapsed time are displayed via dual LED readouts for immediate operator verification. For laboratories requiring electronic record retention, the unit features analog voltage outputs (0–5 V) compatible with third-party data loggers or SCADA systems. When integrated into a validated analytical workflow, these signals can be timestamped and archived alongside copper strip evaluation reports to satisfy traceability requirements under GLP and internal quality management systems (QMS). No firmware updates or cloud connectivity are provided; all calibration and maintenance procedures follow manufacturer-recommended intervals documented in the English-language operation manual.
Applications
- Refinery final product release testing of LPG prior to pipeline injection or cylinder filling.
- Monitoring sulfur compound breakthrough in amine treaters and molecular sieve beds via accelerated copper corrosion response.
- Verification of inhibitor efficacy in LPG distribution systems where mercaptan scavengers or corrosion inhibitors are deployed.
- Research and development of low-corrosivity LPG formulations for automotive or residential fuel applications.
- Third-party inspection agencies performing contractual compliance verification per supply agreements referencing SH/T 0232 or equivalent specifications.
FAQ
What standards does the PLD-0232A comply with?
It is engineered and verified for full conformance with SH/T 0232. Its thermal performance and mechanical configuration also support method equivalence with ASTM D130 and ISO 6251.
Can the instrument be used for liquid-phase testing?
No. The PLD-0232A is configured strictly for vapor-phase exposure per SH/T 0232. Liquid immersion testing requires alternative apparatus meeting ASTM D130 Annex A1 or IP 154 specifications.
Is calibration traceable to national standards?
Yes. The integrated PT100 sensor is factory-calibrated against NIM-traceable references; users receive a calibration certificate with each unit. Annual recalibration is recommended.
What maintenance is required for long-term reliability?
Routine cleaning of the stainless bath with deionized water, periodic inspection of heater element continuity, and verification of gasket integrity on test cylinder caps are sufficient. No lubrication or consumable parts are required.
Does the unit support external data export?
It provides analog output signals (temperature and timer) for integration with external logging hardware. USB or Ethernet interfaces are not included in the base configuration.

