PULUODY
Filter
Showing 1–30 of 412 results
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-262A |
| Price | Upon Request |
| Measuring Range | Ambient Temperature to 150 °C |
| Stirring Speed | 0–1200 rpm |
| Heating Power | 25 W |
| Brand | PULUODY |
|---|---|
| Model | PLD-3535E |
| Origin | Shaanxi, China |
| Instrument Type | Benchtop Automatic Pour/Cloud Point Analyzer |
| Standards Compliance | ASTM D5950-14, GB/T 3535 |
| Temperature Control Range | +50 °C to –70 °C |
| Control Accuracy | ±0.1 °C |
| Detection Method | Optical Liquid Surface Detection |
| Test Interval | 2 °C, 3 °C or User-Defined |
| Tilt Angles | 45° and 90° (Motorized Mechanical Actuation) |
| Dual Independent Bath Positions | 2 |
| Sample Volume | 10 mL per test |
| Test Duration | <10 s per measurement step |
| Repeatability | ±0.2% (of reading) |
| Power Supply | AC 200 V ±10%, 50 Hz |
| Power Consumption | 2000 W |
| Operating Environment | 5–35 °C, <85% RH |
| Display | 7″ Touchscreen LCD |
| Output | Panel-Mount Thermal Printer |
| Cooling System | Miniature Cascade Compressor (Air-Cooled, No External Chiller Required) |
| Key | Brand: PULUODY |
|---|---|
| Model | PLD-0232A |
| Temperature Control Range | 40 °C |
| Temperature Accuracy | ±0.5 °C |
| Timing Range | 0–100 min (user-adjustable) |
| Power Supply | AC 220 V |
| Max. Power Consumption | 1200 W |
| Construction | Stainless Steel Bath & Lid |
| Compliance | SH/T 0232 |
| Key | Brand: PULUODY |
|---|---|
| Model | PS-8011 |
| Material | High-purity borosilicate glass |
| Volume | 220 mL / 250 mL (standard) |
| Cleanliness Grade | NAS 00–4 |
| RCL | ≤15 particles/100 mL |
| AOQL | 0.5% |
| Temperature Resistance | up to 150 °C |
| Pressure Rating | 0.1 MPa |
| Compliance | ISO 3722, ISO 4406, NAS 1638, ISO 16232, GJB 420A/B, GB/T 14039, GB/T 17484, SAE AS749D, DL/T 427, DL/T 1096 |
| Sterilization Method | Ultrasonic cleaning + Class 100,000 cleanroom air shower + nitrogen-purged sealing |
| Cap Type | Leak-proof external-thread cap with O-ring seal |
| Cap Color Options | Blue, Orange-Yellow, Pink |
| Manufacturing | Fully automated production line |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2QY |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–0.5 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + piston pump |
| Accuracy | ±3% typical |
| Volume Accuracy | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex spheres |
| Output | 4–20 mA analog signal,超标 alarm (customizable) |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen UI) |
| Compliance | Designed for ISO 14644-1 cleanroom monitoring, USP <788> & <789>, ASTM F3239, and semiconductor-grade ultrapure water (UPW) validation protocols |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Light Obscuration (LO) |
| Standards Compliance | ISO 4406:1999, NAS 1638, GJB 420B, GJB 380, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95 |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min (electromagnetically regulated piston pump) |
| Sampling Volume | 1 mL to unlimited (programmable) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Pressure Range | –0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment system) |
| Max. Fluid Viscosity | ≤350 cSt |
| Operating Temperature | Ambient to 65 °C |
| Ambient Temperature Range | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Data Output | Onboard thermal printer, RS232 interface, histogram & distribution curve generation |
| Calibration Traceability | Certified by CALIBRATION STATION NO. 116, National Defense Science & Technology Industry Particle Metrology Level-1 Station (Aviation Industry Particle Metrology Center) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CCACS1.0 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm (c), customizable bins (e.g., 4–128 bins) |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | Offline 0–99 mm²/s |
| Temperature Range | Fluid 0–80 °C |
| Sampling Precision | <±1% |
| Output Interfaces | RS232, RS485, USB, LAN, 4–20 mA analog, MODBUS protocol |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, GBW reference materials |
| Compliance | GB/T 11446.9, GJB 420B-2006, HB 6639/6649, QJ 2850/3024, MIL-STD-1246C, SAE AS4059F, NAVAIR 01-1A-17, ROCT 17216-2001 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | CCACS1.0-01 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Light Obscuration (LO) |
| Laser Sensor | 7th-Generation Dual-Laser Narrow-Beam Detector |
| Channel Count | 1000 adjustable channels |
| Size Range | 0.1 µm (c) to 100 µm |
| Resolution | >95% |
| Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (5% error) |
| Sample Flow Rate | 5–1500 mL/min |
| Viscosity Range | 0–99 mm²/s (offline), up to 500 mm²/s (pressurized) |
| Temperature Range | Fluid 0–80°C, Ambient −15–50°C |
| Calibration Standards | JJG 1061, ISO 21501-4, GB/T 11446.9, GJB 420B-2006, SAE AS4059F, MIL-STD-1246C, HB 6639/HB 6649, NAVAIR 01-1A-17 |
| Compliance | GLP/GMP-ready data integrity, 21 CFR Part 11-compatible audit trail (via optional software module) |
| Interface | RS232/RS485, USB, LAN, 4–20 mA analog output, MODBUS protocol |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic Instrument |
| Model | CLDEE-CCACS2.0 |
| Price | USD 5,180 (FOB) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CLDEE-CCACS2.0 |
| Price | USD 5,150 (approx.) |
| Brand | PULUODY |
|---|---|
| Model | DMA-135 |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Sample Volume | 2 mL |
| Measurement Time | ≤60 s |
| Display | 2.4″ Color LCD (320×240) |
| Power | 9 V alkaline battery (≈90 h operation) |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, DB/T 1231–2010, SN/T 2383–2009 |
| Brand | PULUODY |
|---|---|
| Model | DMA-135D |
| Principle | U-tube Oscillation Method |
| Measurement Range | 0.0000–3.0000 g/cm³ |
| Resolution | 0.0001 g/cm³ |
| Accuracy | ±0.001 g/cm³ |
| Repeatability | ±0.0005 g/cm³ |
| Temperature Range | 0.0–50.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Temp. Repeatability | ±0.1 °C |
| Sample Volume | 2 mL |
| Sampling Method | Manual syringe or integrated pump (for liquids < 2000 mPa·s) |
| Measurement Time | ≤60 s |
| Display | 2.4″ color LCD, 320×240 pixels |
| Power | 9 V alkaline battery |
| Battery Life | ~90 h |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Type | Portable Instrument |
| Compliance | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, DB/T 1231–2010, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DMA-135D |
| Instrument Type | Portable Oscillating U-Tube Densimeter |
| Sample Type | Liquids |
| Density Range | 0.001–1.999 g/cm³ |
| Density Accuracy | ±0.01 g/cm³ |
| Temperature Range | 0–50 °C |
| Repeatability | ±0.01 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | 10 mL |
| Compliance Standards | GB/T 29617–2013, GB/T 2013–2010, SH/T 0604–2000, SN/T 2383–2009, ASTM D4052–11, ASTM D5002–13, ASTM D3505–12e1, ISO 12185:1996, IP 559–2008 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1511 |
| Instrument Type | Optical Particle Counter |
| Measurement Principle | Laser Diffraction & Dynamic Light Scattering (DLS) / Flow Imaging |
| Test Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Detection System | 7th-Generation Dual-Laser Narrow-Beam Sensor |
| Compliance | ISO 13320, ISO 13321, SY/T 5329-2012, SY/T 6596-2016 |
| Repeatability | ≤ ±1% for D50 (certified reference materials) |
| Sample Throughput | ≤ 2 min per sample |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 10–30 °C, RH < 85%, vibration-free, EMI-shielded, grounded power |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1511 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–500 µm |
| Repeatability | <1% |
| Measurement Time | 60 sec |
| Detection Principle | Optical Diffraction & Scattering / Laser Flow Imaging |
| Compliance | ISO 13320, ISO 13321 |
| Sample Throughput | One sample per ≤2 min |
| Software Interface | Bilingual (English/Chinese), Windows-compatible |
| Reporting | D3, D10, D25, D50, D75, D80, D90, D97, D100, Span, Specific Surface Area, Aspect Ratio, Circularity Distribution |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513 |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Laser Diffraction & Flow Imaging Hybrid Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | <5% (D50) |
| Measurement Time | ≤30 s per sample |
| Detection Principle | Laser Diffraction (ISO 13320 compliant) + Hydrodynamic Focusing Flow Imaging (ISO 13321 compatible) |
| Sample Introduction | Static cuvette & recirculating wet dispersion unit |
| Software Platform | Windows-native, bilingual (EN/CN), 20 report templates |
| Compliance | SY/T 5329–2012, Q/SY 01004–2016, SY/T 6596–2016, SY/T 5523–2016 |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1513-1 |
| Measurement Principle | Optical Diffraction & Scattering (ISO 13320) / Laser Flow Imaging (ISO 13321) |
| Dynamic Range | 1 nm – 2000 µm (configurable sub-ranges: 1–10,000 nm |
| Repeatability | ≤ ±1% RSD for D50 (certified reference materials) |
| Sample Throughput | ≤2 min per analysis |
| Compliance | SY/T 5329–2022, SY/T 5523–2016, Q/SY 01004–2016, ISO 13320, ISO 13321 |
| Detector | 7th-generation dual-laser narrow-beam photodetector |
| Software | Windows-compatible bilingual (EN/CN), 20 report templates, automated workflow (alignment, background, concentration adjustment, acquisition, analysis, cleaning) |
| Power | AC 220 V ±10%, 50 Hz, 300 W |
| Operating Environment | 0–40 °C, clean lab environment |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1513-a |
| Price | USD 39,200 (approx.) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 1% |
| Measurement Time | 30–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513-b |
| Origin | Shaanxi, China |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 5% |
| Measurement Time | 30–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DPC-2602 |
| Price Range | USD 140 – 39,500 (FOB) |
| Sensor Technology | 7th-Generation Dual-Laser Narrow-Beam Optical Detection |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/5.0/10.0 µm |
| Counting Accuracy | <5% coincidence error at 2×10⁶ particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | Programmable (default 60 s) |
| Operating Temperature | 5–45 °C |
| Relative Humidity Limit | ≤90% RH (non-condensing) |
| Battery | Rechargeable 4100 mAh Li-polymer |
| Display | 3.45″ industrial-grade full-view color LCD |
| Data Storage | 10,000 measurement records |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, EU GMP Annex 1 (2022), USP <788> |
| Optional Modules | Integrated temperature/humidity sensor (–40 to 120 °C / 0–100% RH), CO/HCHO electrochemical gas sensors |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/3.0/5.0/10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, ≥98% at ≥0.5 µm (per ISO 21501-4) |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Data Storage | 10,000 measurement records |
| Battery | 4100 mAh Rechargeable Polymer Li-ion |
| Display | 3.45″ Full-View Industrial Color LCD |
| Operating Temperature | 5–45 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, ISO 21501-4:2018 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, and 10.0 µm (configurable channel sets A–D) |
| Counting Efficiency | ≥50% at 0.3 µm |
| Coincidence Error | <5% at 2,000,000 particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Mode | Timed (60 s default) or cyclic |
| Data Storage | 10,000 measurement records |
| Display | 3.45″ industrial-grade full-view color LCD |
| Power | Rechargeable 4100 mAh polymer lithium battery |
| Operating Temp. | 5–45 °C |
| Operating Humidity | ≤90% RH, non-condensing |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, EU GMP Annex 1 (2022), USP <788> |
| Optional Sensors | Temperature & relative humidity (–40 to 120 °C / 0–100% RH), CO, HCHO |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Sensor Technology | 7th-Generation Dual-Laser Narrow-Beam Detection |
| Particle Size Channels | Configurable Sets Including 0.3/0.5/1.0/2.5/5.0/10.0 µm |
| Counting Accuracy | <5% coincidence error at 2,000,000 particles/ft³ |
| Flow Rate | 2.83 L/min (0.1 cfm) |
| Sampling Time | Programmable (default 60 s) |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤90% RH (non-condensing) |
| Battery | Rechargeable 4100 mAh polymer lithium-ion |
| Data Storage | Up to 10,000 measurement records |
| Display | 3.45-inch industrial-grade full-view color LCD |
| Compliance | ISO 14644-1:2015, GB/T 16292–1996, GMP Annex 1 (2022), USP <788> (particle counting in compressed gases) |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Instrument Type | Optical Airborne Particle Counter |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, or 100 L/min |
| Sampling Time | 60 s default |
| Display | 10.0-inch industrial TFT-LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11-ready |
| Environmental Monitoring Modes | Particle count (#/L), Mass concentration (µg/m³), Filtration efficiency (%) |
| Integrated Sensors | Ambient temperature (−40–120 °C), Relative humidity (0–100% RH), Optional gas sensors (CO, HCHO, etc.) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Conditions | 5–45 °C, ≤90% RH (non-condensing) |
| Protection Features | Overvoltage, overcharge, short-circuit, ESD, and EMI shielding |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83, 28.3, 50, or 100 L/min |
| Sampling Time | 60 s default |
| Display | 10.0-inch industrial TFT-LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB/SD) |
| Environmental Sensors | Integrated temperature (−40 to +120 °C), relative humidity (0–100% RH), dew point |
| Gas Detection Capability | Optional 1–3-channel electrochemical or NDIR sensors (e.g., CO, HCHO) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11 (audit trail, electronic signatures, role-based access) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤90% RH non-condensing |
| Protection | Overvoltage, overcharge, short-circuit, ESD & EMI shielding |
| Brand | PULUODY |
|---|---|
| Model | DPC-2611 |
| Instrument Type | Optical Airborne Particle Counter |
| Detection Principle | Light Scattering (Mie Theory) |
| Particle Size Range | 0.10–25.0 µm (configurable channels) |
| Channel Count | 20 user-selectable size bins |
| Counting Accuracy | ≤±30% (per ISO 21501-4) |
| Concentration Accuracy | ≤±30% |
| Repeatability | ≤±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, or 100 L/min |
| Sampling Time | 60 s default |
| Environmental Sensors | Integrated temperature (−40 to +120 °C), relative humidity (0–100% RH), dew point |
| Gas Detection Capability | Up to 3 optional electrochemical or NDIR gas sensors (e.g., CO, HCHO) |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE, 21 CFR Part 11 (audit trail, electronic signatures, role-based access) |
| Display | 10.0-inch industrial-grade TFT LCD with full-view angle |
| Data Storage | ≥10,000 test records (expandable via USB/SD) |
| Output Interfaces | RS232, RS485, LAN, USB |
| Alarm Modes | Configurable particle count/mass thresholds |
| Power | AC 100–240 V, 50/60 Hz |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Safety Protections | Overvoltage, overcharge, short-circuit, ESD-hardened, EMI-shielded enclosure |
| Brand | PULUODY |
|---|---|
| Model | DPC-2615 |
| Instrument Type | Handheld |
| Flow Rate | 1.0 L/min |
| Flow Accuracy | ≤ ±5% |
| Timing Accuracy | ≤ ±1 s |
| Repeatability | ≤ ±5% |
| Size Distribution Accuracy | ≤ ±5% |
| Indication Error | ≤ ±5% |
| PM Measurement Channels | PM1.0, PM2.5, PM10, TSP |
| Mass Concentration Range | 0–10 mg/m³ (extendable to 100 mg/m³) |
| Laser Source | IEC 60825-1 Class 2 |
| Response Time | 1 s |
| Data Storage Capacity | ≥ 7,000,000 records |
| Battery Life | ≥ 4.5 h @ 25°C, 50% RH |
| Operating Temperature | −20 to +60°C |
| Relative Humidity Range | 0–99% RH |
| Atmospheric Pressure Range | 86–110 kPa |
| Power Input | DC 16.8 V / 1 A |
| Rated Power | 4.1 W |
| Display | 3.5-inch touchscreen |
| Dimensions | 175 × 105 × 65 mm |
| Weight | 0.89 kg |
| Calibration Traceability | NIST-traceable standard particles |
| Compliance Standards | HJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015 |
| Brand | PULUODY |
|---|---|
| Model | DPC-2615A |
| Instrument Type | Handheld |
| Flow Rate | 1 L/min |
| Flow Accuracy | ≤±5% |
| Timing Error | ≤±1 s |
| Repeatability | ≤±5% |
| Size Distribution Error | ≤±5% |
| Indication Error | ≤±5% |
| PM1.0 Accuracy | ±9.5% or ±7.5 µg/m³ |
| TSP Accuracy | ±15% or ±25 µg/m³ |
| Operating Temperature | −20–60 °C |
| Relative Humidity Range | 0–99% RH |
| Atmospheric Pressure Range | 86–110 kPa |
| Response Time | 1 s |
| Data Storage Capacity | ≥7,000,000 records |
| Battery Life | ≥4 h (25 °C, 50% RH) |
| Laser Source | IEC 60825-1 Class 2 |
| Compliance Standards | HJ 1263–2022, WS/T 206–2001, LD 98–1996, GB/T 45795–2025, AQ/T 4268–2015 |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-2623, DPC-2611, DPC-2602 |
| Instrument Type | Optical Particle Counter |
| Flow Rate Options | 2.83 L/min, 28.3 L/min, 50 L/min, 100 L/min |
| Particle Size Channels | Configurable from 0.10 µm to 25.0 µm (6-channel selectable calibration sets) |
| Counting Accuracy | ≤ ±30% for particle size distribution |
| Repeatability | ≤ ±10% FS |
| Coincidence Error | <5% at 2×10⁶ particles/ft³ |
| Compliance | ISO 21501-4, ISO 14644-1, GB/T 16292, GB/T 6167, JJF 1190, JIS B9921, CE |
| Data Storage | ≥10,000 test records with timestamp, location tag, and operator ID |
| Communication | RS232, RS485, LAN, USB |
| Regulatory Features | Audit trail, user access control, electronic signatures per 21 CFR Part 11 |
| Operating Environment | 5–45 °C, ≤90% RH (non-condensing) |
| Power Supply | AC 100–240 V, 50/60 Hz |