PULUODY PLD-601 Liquid Particle Counting and Size Distribution Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PULUODY
Origin United Kingdom
Manufacturer Type Original Equipment Manufacturer (OEM)
Product Category Imported Instrument
Model PLD-601
Price Range USD 55,000–69,000 (FOB UK)
Dispersion Method Wet Dispersion
Instrument Type Laboratory Laser-Based Particle Counter
Measurement Range 0.1–800 µm
Repeatability ≥99%
Measurement Time 10–60 s

Overview

The PULUODY PLD-601 Liquid Particle Counting and Size Distribution Analyzer is a dedicated optical blockage (light extinction) particle counter engineered for high-precision quantification and sizing of suspended particulate matter in liquid media. Unlike laser diffraction-based instruments optimized for broad size distribution profiling, the PLD-601 implements the ISO 21501-4–compliant light blockage principle—where individual particles passing through a focused laser beam generate transient voltage pulses proportional to their cross-sectional area. This enables absolute counting (particles/mL), discrete channel-based size binning, and statistically robust contamination assessment down to 0.1 µm. Designed specifically for quality control laboratories in pharmaceutical manufacturing, semiconductor process chemistry, medical device validation, and precision fluid maintenance, the PLD-601 meets or exceeds the photometric sensitivity and calibration traceability requirements of USP , USP , EP 2.9.19, JP 6.07, and ChP 2015 Edition General Chapter 0903. Its dual-laser narrow-beam detection architecture minimizes coincidence error and enhances signal-to-noise ratio across ultra-low concentration regimes (<100 particles/mL) and high-concentration slurries (up to 10,000 particles/mL with ≤5% coincidence deviation).

Key Features

  • Seventh-generation dual-laser optical sensing system with configurable sensor modules (A–N), supporting simultaneous multi-range detection from 0.03 µm to 2000 µm
  • Integrated industrial-grade embedded controller with 7-inch color TFT touchscreen interface—enabling standalone operation without external PC or printer
  • Onboard thermal printer and non-volatile memory storing ≥20,000 test records; expandable via USB mass storage
  • Modular channel configuration: user-selectable binning schemes (4–1024 channels) with customizable threshold values per channel
  • RS232, RS485-to-USB, and MODBUS RTU communication protocols for integration into LIMS, MES, or SCADA systems
  • Compliance-ready firmware architecture supporting audit trails, electronic signatures, and 21 CFR Part 11–compatible data integrity controls (optional configuration)
  • Micro-liter precision metering pump with ±1% volumetric accuracy and programmable flow rates (5–60 mL/min for sampling; 5–500 mL/min for cleaning)
  • Calibration traceable to NIST-traceable polystyrene latex (PSL) standards and certified reference materials (GBW series); optional third-party metrological verification report available

Sample Compatibility & Compliance

The PLD-601 is validated for use with aqueous and organic liquid matrices including ultrapure water (UPW), pharmaceutical injectables (large-volume parenterals, small-volume parenterals, lyophilized reconstitution solutions), grinding fluids, cutting oils, hydraulic fluids, electroplating baths, and sterile filtration challenge streams. It accommodates viscosity ranges up to 500 mm²/s under pressurized sampling and operates within fluid temperature limits of 0–80 °C. All measurement protocols align with ISO 11171 (calibration standard), ISO 4402 (obsolete but referenced in legacy methods), JJG 1061 (Chinese national metrological verification regulation), and ASTM F312-22 (standard test methods for microparticle contamination in liquids). The instrument supports dual-mode reporting: absolute particle count per milliliter and ISO 4406 / NAS 1638 / SAE AS4059 contamination code assignment.

Software & Data Management

The analyzer runs P6.4 Analytical Software Suite—an integrated firmware environment supporting automated cleaning cycles, multi-point calibration, pulse-height threshold optimization, and real-time histogram generation. Data export formats include CSV, PDF, and XML compliant with laboratory informatics systems. Optional PC-hosted P6.4 Desktop Edition adds advanced statistical analysis (Weibull fitting, cumulative distribution overlays, batch trend monitoring), GLP-compliant electronic lab notebook (ELN) linkage, and automated report templating per regulatory submission requirements (e.g., FDA IND/NDA filings). Audit trail logs record all user actions—including parameter changes, calibration events, and result modifications—with immutable timestamps and operator ID attribution.

Applications

  • Pharmaceutical: Quantitative insoluble particle testing per USP and ChP 0903; filter integrity validation; container closure system extractables/leachables screening
  • Biotechnology: Protein aggregation monitoring in monoclonal antibody formulations; viral vector suspension characterization
  • Semiconductor: UPW and chemical mechanical planarization (CMP) slurry cleanliness verification per SEMI F63
  • Medical Devices: Particulate shedding assessment from catheters, stents, and implant packaging per ISO 10993-12
  • Industrial Fluids: Wear debris analysis in gear oil and turbine oil per ISO 4406; contaminant profiling in phosphating and cleaning baths
  • Academic Research: Fundamental studies of colloidal stability, nanoparticle dispersion kinetics, and microfiltration fouling mechanisms

FAQ

Does the PLD-601 comply with 21 CFR Part 11 for electronic records and signatures?
Yes—when configured with optional secure login, role-based access control, and encrypted audit trail logging, the system satisfies predicate rule requirements for regulated environments.
Can the instrument measure sub-100 nm particles in aqueous suspensions?
With Sensor D/E/F modules (0.03–0.20 µm range), it achieves reliable detection at 30–200 nm under optimized flow and background noise suppression; however, ISO 21501-4 defines the lower practical limit as 0.1 µm for certified light blockage counters.
Is calibration verification performed using NIST-traceable standards?
All factory calibrations use PSL spheres certified to ISO 21501-4 and NIST SRM 1963; customers receive calibration certificates with uncertainty budgets and traceability statements.
What maintenance intervals are recommended for routine operation?
Daily rinse cycle post-use; quarterly optical path inspection and sensor alignment verification; annual full metrological recalibration using GBW-certified reference materials.
How does the PLD-601 handle high-viscosity samples such as glycerol-based formulations?
Integrated pressure-assisted sampling permits stable aspiration up to 500 mm²/s kinematic viscosity; optional heated sample chamber maintains consistent fluid rheology during analysis.