| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | LactoFlash |
| Automation | Fully Automatic |
| Analysis Speed | Up to 120 samples/h |
| Measurement Range | Fat 0.00–30.00%, Non-Fat Solids (NFS) 0.00–15.00% |
| Repeatability | ±0.02% (Fat, 0–5%), ±0.04% (NFS) |
| Accuracy | ±0.01% (Fat & NFS) |
| Sample Volume | 12–20 mL |
| Interface | 1× Parallel Port, 1× RS232, 1× USB, 1× 6 V DC output |
| Power Supply | 230 V / 115 V AC, 50–60 Hz, 180 W |
| Dimensions (W×H×D) | 30 × 24 × 33 cm |
| Weight | 5 kg |
| Display | Integrated LCD interface |
| Calibration | Two-point calibration with on-screen prompts |
| Data Storage | Internal memory for sample results and calibration logs |
| Language Options | English and German |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | SuperVario-N |
| Max Speed | 1130 rpm |
| Max RCF | 372 × g |
| Speed Range | 600–1130 rpm (adjustable in 10 rpm increments) |
| Temperature Range | Ambient to 68 °C (adjustable in 1 °C increments) |
| Time Setting | 1–99 min |
| Heating Function | Yes (maintains sample tube temperature ≥50 °C during operation) |
| Pre-programmed Methods | Gerber, Babcock, Rose-Gottlieb, Solubility Method |
| Safety Features | Automatic lid lock, imbalance detection, electronic braking |
| Power Supply | 230 V / 50 Hz |
| Net Weight | 26 kg |
| Rotor Options | Rotor A (Gerber, 36×31 mm tubes), Rotor B (Babcock, 36×32 mm tubes), Rotor C (Rose-Gottlieb, custom adapter), Rotor D (Solubility/ADMI, 36×33 mm tubes) |
| Compliance | CE-marked, designed per IEC 61010-1 for laboratory equipment safety |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | LactoStar |
| Automation | Fully Automatic |
| Analysis Speed | Up to 90 samples/h |
| Measurement Range | 0.00–40.00% (fat), 0.00–10.00% (protein, lactose, non-fat solids), 0.00–5.00% (minerals) |
| Repeatability | ±0.01% (fat @ 0–8%), ±0.02% (fat @ 8–40%), ±0.03% (protein/lactose), ±0.04% (non-fat solids), ±0.02% (minerals) |
| Accuracy | ±0.01% (all parameters) |
| Sample Volume | 12–20 mL |
| Display | LCD interface |
| Dimensions | 43 × 20 × 43 cm (W × H × D) |
| Weight | 15.7 kg |
| Power Supply | 230 V / 115 V AC, 50–60 Hz, 180 W |
| Interfaces | 1× Parallel port, 1× RS232, 1× USB, 1× 6 V DC output |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | CryoStar |
| Automation | Fully Automatic |
| Analysis Speed | Up to 40 samples/h (typical 30 samples/h) |
| Measurement Range | 0.0000 °C to −1.5000 °C |
| Repeatability | ±0.0020 °C |
| Accuracy | 0.0001 °C |
| Sample Volume | 2.2 mL (recommended) |
| Power Supply | 230 V / 115 V AC, 50–60 Hz, 180 VA |
| Cooling Time | ~15 min |
| Display | 7″ color touchscreen |
| Interfaces | 2× RS-232, 2× USB, Ethernet |
| Dimensions (CryoStar 1) | 290 × 380 × 190 mm (W×D×H), 12.0 kg |
| Dimensions (CryoStar Automatic) | 440 × 440 × 200 mm (W×D×H), 14.6 kg |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | FermentoFlash |
| Instrument Type | Dedicated Beer Analyzer |
| Application | Laboratory Use |
| Measurement Time | 1 min |
| Alcohol Content Range | 0.00–15.00 % v/v |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 300 × 240 × 330 mm |
| Weight | 5 kg |
| Density Range | 0.95–1.05 g/cm³ |
| Extract Range | 0.00–10.00 % m/m |
| Apparent Extract Range | 0.00–10.00 % m/m |
| Original Wort Gravity Range | 0.00–20.00 °P |
| Density Repeatability | ±0.0002 g/cm³ |
| Alcohol Repeatability | ±0.02 % v/v |
| Extract & Apparent Extract Repeatability | ±0.04 % m/m |
| Original Wort Gravity Repeatability | ±0.02 °P |
| Calibration Memory | 18 profiles |
| Interface | USB/RS-232 for PC connectivity |
| Included Accessories | Integrated thermal printer, 100 mL conical sample vial, 5 L zero-point calibration buffer, 500 mL cleaning solution |