- All
- Favorite
- Popular
- Most rated
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | Enviro-Genie |
| Instrument Type | Full-temperature orbital shaker/incubator |
| Timer Range | 1 s – 99 hr |
| Oscillation Frequency | 2–70 cycles/min |
| Temperature Range | 4–75 °C |
| Number of Shaking Platforms | 1 |
| Rotation Speed | 1–35 rpm |
| Stirring Speed | 1–2000 rpm (with reverse) |
| Temperature Accuracy | ±0.2 °C |
| Temperature Uniformity | ±0.5 °C |
| Chamber Volume | 24 L |
| Platform Load Capacity | 4.5 kg |
| Net Weight | 36 kg |
| Interface | RS232 |
| Brand | Qsonica LLC |
|---|---|
| Country of Origin | USA |
| Model | Q700 |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 700 W |
| Operating Frequency | 20 kHz |
| Temperature Range | 1–121 °C |
| Sample Volume Capacity | 5 µL – 1000 L (via flow cell or microtip) |
| Throughput | 1–384 samples per run |
| Compliance | UL, CE, CSA, RoHS |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 455 |
| Price | €50,000 |
| Static Evaporation Rate | <0.5 L/day |
| Dispensing Flow Rate | Droplet-to-2 L/min (Fixed, Non-adjustable) |
| Operating Pressure | <200 mBar |
| Hose Pre-cooling Time | 10–40 s (Dependent on LN₂ Level) |
| Power Supply | 115 V / 230 V AC or 12 V AC/DC |
| Average Power Consumption | 10 W (Peak: 50 W) |
| Dewar Capacity | 35 L / 50 L |
| Dewar Diameter | 480 mm / 500 mm |
| Dewar Height | 643 mm / 727 mm |
| Empty/Full Weight | 13 / 41.5 kg (35 L) or 17 / 57.5 kg (50 L) |
| Standard Equipment | Controller, Power Unit, Interconnecting Cables |
| Optional Accessories | 5-Wheel Mobile Base (10 cm height), LN₂ Pump Mounting Bracket |
| Brand | IBI Scientific |
|---|---|
| Origin | USA |
| Model | Belly Button |
| Instrument Type | Mini Orbital Shaker |
| Speed Range | 0–100 rpm |
| Tilt Angle Adjustment | 0–8° |
| Operating Temperature | 0–40 °C |
| Platform Size | 18 × 18 cm |
| Load Capacity | 2 kg (5 lbs) |
| Platform Material | Chemically Resistant Polymer |
| Noise Level | <45 dB(A) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE, RoHS |
| Compliance | Suitable for ISO 13485-aligned lab workflows, compatible with GLP documentation requirements |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Model | 900 |
| Supply Pressure Range | 0.01–270 mBar (adjustable) |
| Flow Rate | Dropwise to 0.5 L/min |
| Maximum Working Pressure | 300 mBar |
| Static Evaporation Rate | <0.5 L/day |
| LN₂ Lift Height | 5 m |
| Power Supply | 115/230 V AC or 12–24 V AC/DC |
| Average Power Consumption | 5 W (50 W during dispensing) |
| Standard Tubing | 2 m length, 4 mm ID / 6.25 mm OD PTFE, insulated with 32 mm foam jacket |
| Integrated LN₂ Dewar Options | 35 L, 50 L, or 100 L |
| System Includes | Dewar, cryogenic pump, 2 m tubing, phase separator, power supply, cables, level sensor(s), PC software |
| Brand | Norhof |
|---|---|
| Country of Origin | Netherlands |
| Model | 608 |
| Supply Voltage | 115/230 V AC or 12–24 V AC/DC |
| Power Consumption | 10 W (avg.), 50 W (during dispensing) |
| Static Evaporation Rate | <0.5 L/day |
| Working Pressure | <300 mbar |
| Precooling Time (1.6 m tubing) | ±1 min |
| Tubing | PTFE, OD 6.25 mm / ID 4 mm, insulated with 32 mm foam jacket |
| LN₂ Tank Options | 35 L / 50 L / 100 L |
| Tank Dimensions (Ø × H) | 480 × 791 mm / 500 × 875 mm / 500 × 1235 mm |
| Empty/Full Weight | 13/41.5 kg / 17/57.5 kg / 32/113 kg |
| Dispensing Control | Timer-based auto-fill (1 level sensor) or external 5 V TTL / RS232 trigger |
| Software Interface | PC-based monitoring suite with real-time pump status, event logging, and configurable alarms |
| Safety Protections | Mechanical overpressure relief valve, low-LN₂ (≤5 L) alert, empty-tank detection, sensor failure alarm, freeze detection |
| Optional Accessories | Bruker FTIR detector adapter, Shimadzu AIM-8800 adapter, 5-wheel mobile base (10 cm height), LN₂ pump mounting bracket, custom sensor mounting fixtures |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CG-1 |
| Capacity | 46 L (below rotary rack) / 407 L (total) |
| Evaporation Rate | 8 L/day |
| Hold Time | 33 days |
| External Dimensions | 864 mm (Ø) × 1524 mm (H) |
| Net Weight | 295 kg |
| Operating Temperature | ≤ −135 °C (vapor phase) |
| Control System | Auto Protector Plus with 7-level capacitive liquid level sensors, dual temperature monitoring (sample & vapor), RS232 data logging, 3–5 day battery backup |
| Brand | Cryosafe |
|---|---|
| Origin | USA |
| Model | CryoMizer |
| Capacity Options | CM-1 / CM-2 / CM-3 / CM-4 |
| Operating Modes | Vapor-phase (−135 °C) and Liquid-phase (−196 °C) Storage |
| Standard Configuration | Cryogenic Rack System, Castor-Mounted Base, LN₂ Level Gauge |
| Compliance | Designed for GLP/GMP-aligned biobanking workflows |
| Brand | Norhof |
|---|---|
| Origin | Netherlands |
| Model | 606 |
| Static Evaporation Rate | <0.5 L/day |
| Dispensing Flow Rate | 0.1 L/min (dropwise) |
| Operating Pressure | <300 mBar |
| Power Supply | 115/230 V AC or 12 V AC/DC |
| Average Power Consumption | 10 W (50 W during dispensing) |
| LN₂ Tank Capacities | 35 L / 50 L / 100 L |
| Tank Dimensions (Ø × H) | 480 × 791 mm / 500 × 875 mm / 500 × 1235 mm |
| Empty/Full Weight | 13/41.5 kg / 17/57.5 kg / 32/113 kg |
| Tubing | PTFE, OD 6.25 mm, ID 4 mm, insulated with 32 mm foam sheath |
| Control Interface | 5 V TTL trigger (on/off), RS232 serial command set |
| Software | PC-based monitoring suite with real-time pump status, alarm logging (empty tank, <5 L remaining, sensor fault, freeze detection), and mechanical overpressure relief valve |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | Incubator-Genie |
| Instrument Type | Air-Jacketed Temperature-Controlled Orbital Shaker |
| Programmable Timer Range | Up to 99 hr |
| Oscillation Speed | 3–35 rpm |
| Temperature Range | 28–75 °C |
| Platform Quantity | 1 |
| Temperature Uniformity | ±0.5 °C |
| Temperature Accuracy | ±0.2 °C |
| Chamber Volume | 24 L |
| Platform Load Capacity | 4.5 kg |
| Net Weight | 19.5 kg |
| Interface | RS232 |
| Optional Accessory | 3D Orbit Module |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-1 |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well (0.2 mL) or 384-well module (field-replaceable) |
| Max Heating/Cooling Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.25 °C |
| Inter-well Temperature Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Channels | 12 independent temperature zones |
| Heat Lid Temperature | 35–115 °C (adjustable, manually pressure-controlled) |
| Heat Lid Uniformity | ±5 °C |
| Heat Lid Preheating Time | <2 min |
| Display | 7" 1080P full-color LCD touchscreen |
| OS | Embedded Android-based firmware |
| Onboard Program Storage | ≥1,000 protocols |
| USB Expansion Support | Yes (USB-A & USB-B) |
| Power Consumption (30-cycle run) | 0.3 kWh |
| Dimensions (W×D×H) | 200 × 260 × 430 mm |
| Rated Power | 425 W |
| Noise Level | <50 dB(A) |
| Brand | Peqlab |
|---|---|
| Origin | Germany |
| Model | Perfect Blot |
| Instrument Type | Nucleic Acid Hybridization Incubator |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Uniformity | ±0.1°C |
| Rotation Speed | 4–20 rpm |
| Chamber Capacity | 12 large or 24 small hybridization tubes |
| External Dimensions | 48.3 × 44.5 × 49.5 cm |
| Internal Dimensions | 36.8 × 27.9 × 34.3 cm |
| Weight | 26.8 kg |
| Brand | PCRmax |
|---|---|
| Origin | United Kingdom |
| Model | AC-2 |
| Sample Capacity | Two independent blocks (configurable as two 96-well, two 384-well, or mixed 96/384 modules) |
| Max Heating Rate | 3.4 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Block Uniformity | ±0.3 °C |
| Temperature Range | 4–100 °C |
| Gradient Range | 10–100 °C |
| Gradient Span | 1–29 °C |
| Gradient Steps | 12 distinct temperatures with identical hold times |
| Thermal Lid | Adjustable manual pressure, 35–115 °C (or off), uniformity ±5 °C, preheat time <2 min |
| Cooling Method | Peltier-based semiconductor |
| Programmable Cycles | Up to 99 |
| Onboard Storage | ≥1000 protocols |
| Interface | 1× USB-A, 1× USB-B |
| Power | 900 W |
| Dimensions (W×D×H) | 470 × 535 × 330 mm |
| Noise Level | <50 dB (per module) |
| Brand | Biochrom |
|---|---|
| Origin | USA |
| Model | BioDrop DUO+ |
| Sample Volume Requirement | 0.5 µL |
| Detection Time | <3 s |
| Wavelength Accuracy | ±2 nm |
| Wavelength Range | 190–1100 nm |
| Absorbance Range | –0.3 A to 2.5 A |
| dsDNA Detection Limit | 1–12,000 ng/µL |
| Protein (BSA) Detection | Supported |
| Light Source | Pulsed Xenon Lamp |
| Detector | 1024-pixel CCD Array |
| Spectral Bandwidth | 5 nm |
| Stray Light | <0.5% T (220 nm, NaCl |
| Absorbance Accuracy | ±0.005 A or ±1% of reading (whichever is greater, at 546 nm) |
| Absorbance Reproducibility | ±0.003 A (0–0.5 A), ±0.007 A (0.5–1.0 A) |
| Optical Path Accuracy (Microvolume) | ±5 µm |
| Dimensions | 410 × 280 × 190 mm |
| Weight | 3.55 kg |
| Power Input | 120–250 V, 50/60 Hz, max. 40 VA |
| Interface | 7-inch capacitive color touchscreen (English, French, German, Spanish, Chinese), USB port for flash drive and PC connectivity |