Empowering Scientific Discovery

Aoran Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScientific Industries
OriginUSA
ModelEnviro-Genie
Instrument TypeFull-temperature orbital shaker/incubator
Timer Range1 s – 99 hr
Oscillation Frequency2–70 cycles/min
Temperature Range4–75 °C
Number of Shaking Platforms1
Rotation Speed1–35 rpm
Stirring Speed1–2000 rpm (with reverse)
Temperature Accuracy±0.2 °C
Temperature Uniformity±0.5 °C
Chamber Volume24 L
Platform Load Capacity4.5 kg
Net Weight36 kg
InterfaceRS232
Added to wishlistRemoved from wishlist 0
Add to compare
BrandQsonica LLC
Country of OriginUSA
ModelQ700
Instrument TypeUltrasonic Cell Disruptor
Ultrasonic Power Output700 W
Operating Frequency20 kHz
Temperature Range1–121 °C
Sample Volume Capacity5 µL – 1000 L (via flow cell or microtip)
Throughput1–384 samples per run
ComplianceUL, CE, CSA, RoHS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorhof
OriginNetherlands
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
Model455
Price€50,000
Static Evaporation Rate<0.5 L/day
Dispensing Flow RateDroplet-to-2 L/min (Fixed, Non-adjustable)
Operating Pressure<200 mBar
Hose Pre-cooling Time10–40 s (Dependent on LN₂ Level)
Power Supply115 V / 230 V AC or 12 V AC/DC
Average Power Consumption10 W (Peak: 50 W)
Dewar Capacity35 L / 50 L
Dewar Diameter480 mm / 500 mm
Dewar Height643 mm / 727 mm
Empty/Full Weight13 / 41.5 kg (35 L) or 17 / 57.5 kg (50 L)
Standard EquipmentController, Power Unit, Interconnecting Cables
Optional Accessories5-Wheel Mobile Base (10 cm height), LN₂ Pump Mounting Bracket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIBI Scientific
OriginUSA
ModelBelly Button
Instrument TypeMini Orbital Shaker
Speed Range0–100 rpm
Tilt Angle Adjustment0–8°
Operating Temperature0–40 °C
Platform Size18 × 18 cm
Load Capacity2 kg (5 lbs)
Platform MaterialChemically Resistant Polymer
Noise Level<45 dB(A)
Power Supply100–240 VAC, 50/60 Hz
CertificationsCE, RoHS
ComplianceSuitable for ISO 13485-aligned lab workflows, compatible with GLP documentation requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorhof
OriginNetherlands
Model900
Supply Pressure Range0.01–270 mBar (adjustable)
Flow RateDropwise to 0.5 L/min
Maximum Working Pressure300 mBar
Static Evaporation Rate<0.5 L/day
LN₂ Lift Height5 m
Power Supply115/230 V AC or 12–24 V AC/DC
Average Power Consumption5 W (50 W during dispensing)
Standard Tubing2 m length, 4 mm ID / 6.25 mm OD PTFE, insulated with 32 mm foam jacket
Integrated LN₂ Dewar Options35 L, 50 L, or 100 L
System IncludesDewar, cryogenic pump, 2 m tubing, phase separator, power supply, cables, level sensor(s), PC software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorhof
Country of OriginNetherlands
Model608
Supply Voltage115/230 V AC or 12–24 V AC/DC
Power Consumption10 W (avg.), 50 W (during dispensing)
Static Evaporation Rate<0.5 L/day
Working Pressure<300 mbar
Precooling Time (1.6 m tubing)±1 min
TubingPTFE, OD 6.25 mm / ID 4 mm, insulated with 32 mm foam jacket
LN₂ Tank Options35 L / 50 L / 100 L
Tank Dimensions (Ø × H)480 × 791 mm / 500 × 875 mm / 500 × 1235 mm
Empty/Full Weight13/41.5 kg / 17/57.5 kg / 32/113 kg
Dispensing ControlTimer-based auto-fill (1 level sensor) or external 5 V TTL / RS232 trigger
Software InterfacePC-based monitoring suite with real-time pump status, event logging, and configurable alarms
Safety ProtectionsMechanical overpressure relief valve, low-LN₂ (≤5 L) alert, empty-tank detection, sensor failure alarm, freeze detection
Optional AccessoriesBruker FTIR detector adapter, Shimadzu AIM-8800 adapter, 5-wheel mobile base (10 cm height), LN₂ pump mounting bracket, custom sensor mounting fixtures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCryosafe
OriginUSA
ModelCG-1
Capacity46 L (below rotary rack) / 407 L (total)
Evaporation Rate8 L/day
Hold Time33 days
External Dimensions864 mm (Ø) × 1524 mm (H)
Net Weight295 kg
Operating Temperature≤ −135 °C (vapor phase)
Control SystemAuto Protector Plus with 7-level capacitive liquid level sensors, dual temperature monitoring (sample & vapor), RS232 data logging, 3–5 day battery backup
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCryosafe
OriginUSA
ModelCryoMizer
Capacity OptionsCM-1 / CM-2 / CM-3 / CM-4
Operating ModesVapor-phase (−135 °C) and Liquid-phase (−196 °C) Storage
Standard ConfigurationCryogenic Rack System, Castor-Mounted Base, LN₂ Level Gauge
ComplianceDesigned for GLP/GMP-aligned biobanking workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandNorhof
OriginNetherlands
Model606
Static Evaporation Rate<0.5 L/day
Dispensing Flow Rate0.1 L/min (dropwise)
Operating Pressure<300 mBar
Power Supply115/230 V AC or 12 V AC/DC
Average Power Consumption10 W (50 W during dispensing)
LN₂ Tank Capacities35 L / 50 L / 100 L
Tank Dimensions (Ø × H)480 × 791 mm / 500 × 875 mm / 500 × 1235 mm
Empty/Full Weight13/41.5 kg / 17/57.5 kg / 32/113 kg
TubingPTFE, OD 6.25 mm, ID 4 mm, insulated with 32 mm foam sheath
Control Interface5 V TTL trigger (on/off), RS232 serial command set
SoftwarePC-based monitoring suite with real-time pump status, alarm logging (empty tank, <5 L remaining, sensor fault, freeze detection), and mechanical overpressure relief valve
Added to wishlistRemoved from wishlist 0
Add to compare
BrandScientific Industries
OriginUSA
ModelIncubator-Genie
Instrument TypeAir-Jacketed Temperature-Controlled Orbital Shaker
Programmable Timer RangeUp to 99 hr
Oscillation Speed3–35 rpm
Temperature Range28–75 °C
Platform Quantity1
Temperature Uniformity±0.5 °C
Temperature Accuracy±0.2 °C
Chamber Volume24 L
Platform Load Capacity4.5 kg
Net Weight19.5 kg
InterfaceRS232
Optional Accessory3D Orbit Module
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCRmax
OriginUnited Kingdom
ModelAC-1
Instrument TypeGradient PCR Thermal Cycler
Sample Capacity96-well (0.2 mL) or 384-well module (field-replaceable)
Max Heating/Cooling Rate3.4 °C/s
Temperature Accuracy±0.25 °C
Inter-well Temperature Uniformity±0.3 °C
Temperature Range4–100 °C
Gradient Range10–100 °C
Gradient Span1–29 °C
Gradient Channels12 independent temperature zones
Heat Lid Temperature35–115 °C (adjustable, manually pressure-controlled)
Heat Lid Uniformity±5 °C
Heat Lid Preheating Time<2 min
Display7" 1080P full-color LCD touchscreen
OSEmbedded Android-based firmware
Onboard Program Storage≥1,000 protocols
USB Expansion SupportYes (USB-A & USB-B)
Power Consumption (30-cycle run)0.3 kWh
Dimensions (W×D×H)200 × 260 × 430 mm
Rated Power425 W
Noise Level<50 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPeqlab
OriginGermany
ModelPerfect Blot
Instrument TypeNucleic Acid Hybridization Incubator
Temperature RangeAmbient +5°C to 80°C
Temperature Uniformity±0.1°C
Rotation Speed4–20 rpm
Chamber Capacity12 large or 24 small hybridization tubes
External Dimensions48.3 × 44.5 × 49.5 cm
Internal Dimensions36.8 × 27.9 × 34.3 cm
Weight26.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPCRmax
OriginUnited Kingdom
ModelAC-2
Sample CapacityTwo independent blocks (configurable as two 96-well, two 384-well, or mixed 96/384 modules)
Max Heating Rate3.4 °C/s
Temperature Accuracy±0.1 °C
Block Uniformity±0.3 °C
Temperature Range4–100 °C
Gradient Range10–100 °C
Gradient Span1–29 °C
Gradient Steps12 distinct temperatures with identical hold times
Thermal LidAdjustable manual pressure, 35–115 °C (or off), uniformity ±5 °C, preheat time <2 min
Cooling MethodPeltier-based semiconductor
Programmable CyclesUp to 99
Onboard Storage≥1000 protocols
Interface1× USB-A, 1× USB-B
Power900 W
Dimensions (W×D×H)470 × 535 × 330 mm
Noise Level<50 dB (per module)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiochrom
OriginUSA
ModelBioDrop DUO+
Sample Volume Requirement0.5 µL
Detection Time<3 s
Wavelength Accuracy±2 nm
Wavelength Range190–1100 nm
Absorbance Range–0.3 A to 2.5 A
dsDNA Detection Limit1–12,000 ng/µL
Protein (BSA) DetectionSupported
Light SourcePulsed Xenon Lamp
Detector1024-pixel CCD Array
Spectral Bandwidth5 nm
Stray Light<0.5% T (220 nm, NaCl
Absorbance Accuracy±0.005 A or ±1% of reading (whichever is greater, at 546 nm)
Absorbance Reproducibility±0.003 A (0–0.5 A), ±0.007 A (0.5–1.0 A)
Optical Path Accuracy (Microvolume)±5 µm
Dimensions410 × 280 × 190 mm
Weight3.55 kg
Power Input120–250 V, 50/60 Hz, max. 40 VA
Interface7-inch capacitive color touchscreen (English, French, German, Spanish, Chinese), USB port for flash drive and PC connectivity
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0