Balance/Scale
Filter
Showing 271–300 of 864 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | ME54 / ME104 / ME204 / ME54E / ME104E / ME204E |
| Maximum Capacity | 52 g / 120 g / 220 g |
| Readability | 0.1 mg |
| Repeatability | ≤ ±0.1 mg |
| Linearity Error | 0.2 mg |
| Stabilization Time | 2 s |
| Sensitivity Drift | 2.0 ppm/°C |
| Pan Diameter | Ø 90 mm |
| Net Weight | 4.7 kg (ME) / 4.5 kg (ME E) |
| Calibration | Internal (ME series) or External (ME E series) |
| Compliance | ISO/IEC 17025, GLP, GMP, USP <41>, ASTM E898 |
| Power Consumption | Reduced by up to 50% vs. prior generation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ME Series |
| Readability | 0.1 mg to 0.1 g |
| Repeatability | ±0.1 mg to ±0.2 g |
| Linearity Error | ±0.2 mg to ±0.2 g |
| Pan Size | 90 mm to 180 × 180 mm |
| Internal Calibration | Yes (auto or manual) |
| External Calibration | Yes |
| Compliance | ISO/IEC 17025, GLP, GMP, USP <41>, ASTM E898, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ME103 |
| Maximum Capacity | 120 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity Error | ±0.002 g |
| Stabilization Time | 1.5 s |
| Sensitivity Drift | 3.0 ppm/°C |
| Pan Diameter | 120 mm |
| Net Weight | 4.6 kg |
| Calibration | Internal |
| Compliance | ISO/GLP-compliant data logging (date/time stamping) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Internal Calibration | Yes |
| Pan Size | 90 mm diameter |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 210 × 344 × 344 mm |
| Construction | Die-cast metal base with reinforced polymer housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104E |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.08 mg |
| Linearity | ±0.2 mg |
| Calibration Method | External (with optional calibration weights) |
| Pan Size | 90 mm diameter |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 210 × 344 × 344 mm |
| Construction | Robust metal chassis with high-grade polymer housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ME104E |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 110 g |
| Readability | 0.0001 g |
| Repeatability | ≤0.0001 g |
| Linearity Error | 0.0002 g |
| Stabilization Time | 2 s |
| Sensitivity Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | 90 mm |
| Dimensions (W × D × H) | 210 × 344 × 344 mm |
| Net Weight | 4.5 kg |
| Calibration | External |
| Interface | RS232 |
| Legal for Trade Class | OIML Class I |
| GLP/GMP Compliance | Date & time stamp, ISO/GLP-compliant reporting |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME2002 |
| Instrument Type | Precision Balance |
| Maximum Capacity | 2200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Linearity | 0.02 g |
| Calibration | Internal |
| Dimensions (W × D) | 180 × 180 mm |
| Display | Backlit LCD with large digits |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME2002E |
| Instrument Type | Precision Balance |
| Maximum Capacity | 2200 g |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Linearity | 0.02 g |
| Calibration Method | External (with standard weights) |
| Dimensions (W × D) | 180 × 180 mm |
| Construction | Reinforced metal frame with ergonomic housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME203 |
| Instrument Type | Precision Balance |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Internal Calibration | Yes |
| Pan Size | 120 mm (diameter) |
| Draft Shield Height | 170 mm |
| Dimensions (W×D×H) | 210 × 319 × 289 mm |
| Construction | Die-cast metal base with reinforced housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME203E |
| Instrument Type | Precision Balance |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Calibration Method | External (using certified weights) |
| Pan Size | 120 mm diameter |
| Draft Shield Height | 170 mm |
| Dimensions (W×D×H) | 210 × 319 × 289 mm |
| Power Supply | AC adapter (included) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Calibration | Internal |
| Pan Size | 90 mm diameter |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 210 × 344 × 344 mm |
| Construction | Die-cast metal base with reinforced housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-manufactured) |
| Model | ME204 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Internal Calibration | Yes |
| Pan Size | 90 mm diameter |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 210 × 344 × 344 mm |
| Weight | Approx. 5.2 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204E |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.0001 g |
| Repeatability | 0.08 mg |
| Linearity | 0.2 mg |
| Calibration Method | External (using certified weights) |
| Pan Size | 90 mm diameter |
| Draft Shield Height | 220 mm |
| Dimensions (W×D×H) | 210 × 344 × 344 mm |
| Construction | Die-cast metal base with reinforced polymer housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ME204T/02 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.08 mg |
| Calibration | Internal (FACT) |
| Display | 4.5" color TFT touchscreen |
| Interface Options | USB, RS232, optional Bluetooth |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME4001 |
| Instrument Type | Precision Balance |
| Maximum Capacity | 4200 g |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Linearity | ±0.2 g |
| Calibration | Internal |
| Dimensions (W × D) | 180 × 180 mm |
| Construction | Reinforced metal frame with integrated leveling feet |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME4001E |
| Maximum Capacity | 4200 g |
| Readability | 0.1 g |
| Repeatability | 0.1 g |
| Linearity | ±0.2 g |
| Calibration Method | External (with standard weights) |
| Dimensions (W × D) | 180 × 180 mm |
| Pan Size | 180 mm diameter |
| Construction | Reinforced metal frame with durable housing |
| Display | Backlit LCD with large-digit readout |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML Series (ML54 / MS104 / MS204) |
| Maximum Capacity | 52 g / 120 g / 220 g |
| Readability | 0.1 mg |
| Repeatability (sd) | 0.1 mg |
| Linearity Error | 0.2 mg |
| Pan Diameter | Ø90 mm |
| Calibration | Internal |
| Power Supply | AC adapter or 8×AA batteries (up to 8 h operation) |
| Connectivity | RS232 and USB |
| Compliance | GxP-ready with audit trail-capable printing (when used with RS-P26 printer) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Range | ML54, ML104, ML204, ML203, ML802, ML6001, ML303E |
| Max Capacity | 52 mg to 6200 g |
| Readability | 0.1 mg to 0.1 g |
| Repeatability | 0.1 mg to 0.001 g |
| Linearity Error | 0.2 mg to 0.002 g |
| Pan Dimensions | Ø90 mm to 170×190 mm |
| Calibration | Internal or External |
| Connectivity | RS232 & USB |
| Power | AC adapter or rechargeable battery |
| Applications | Formulation, piece counting, density determination, statistical analysis, dynamic weighing, checkweighing, percentage weighing, and data retrieval |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML-T |
| Instrument Type | Precision Balance |
| Capacity | ≥ 5000 g |
| Readability | 0.001 g (1 mg) |
| Display | 4.5-inch color TFT touchscreen |
| Weighing Technology | MonoBloc single-module electromagnetic force compensation sensor |
| Calibration | FACT — Fully Automatic Calibration Technology with internal temperature-controlled reference mass |
| Leveling | LevelControl integrated tilt sensor with visual guidance |
| Connectivity | USB Device, USB Host, RS232, optional Bluetooth |
| Data Output | PC Direct mode (no driver or software required) |
| Compliance | ISO/IEC 17025, GLP/GMP traceability support, FDA 21 CFR Part 11 ready (with optional software and user management) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model Variants | ML1602T / ML203T / ML3001T / ML303T / ML4002T / ML503T |
| Maximum Capacity | 6 kg |
| Readability | 0.01 g |
| Repeatability | 0.01 g |
| Calibration | FACT Automatic Internal Calibration |
| Power Supply | AC adapter or rechargeable Li-ion battery |
| Display | 4.5-inch full-color capacitive touchscreen |
| Compliance | ISO/IEC 17025, ASTM E899, USP <41>, GLP/GMP-ready audit trail support |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML104T/02 |
| Type | Analytical Balance |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 100 g) |
| Minimum Weight (USP, typical) | 0.16 g |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Calibration | Internal / FACT |
| Connectivity | RS232, USB Device, USB Host, Optional Bluetooth |
| Housing | Die-cast aluminum with ABS plastic |
| Dimensions (D×H×W) | 290 mm × 193 mm × ? mm |
| Legal for Trade | No |
| Hygienic Design | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ML203T |
| Maximum Capacity | 220 g |
| Readability | 1 mg |
| Calibration | Internal (FACT) |
| Repeatability (typ.) | 0.7 mg |
| Repeatability (100 g test weight) | 1 mg |
| Minimum Weight (USP <0.1% RSD, typical) | 1.4 g |
| Linearity (typ.) | 0.6 mg |
| Settling Time | 1.5 s |
| Weighing Pan Diameter | 120 mm |
| Display | 4.5" color TFT touchscreen |
| Interfaces | RS232, USB Device, USB Host |
| Housing | Die-cast aluminum base with ABS plastic enclosure |
| Power | AC adapter + rechargeable battery |
| Temperature Coefficient | ±3 ppm/°C |
| Legal for Trade | No |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Type | Precision Balance |
| Model | ML203T |
| Maximum Capacity | 220 g |
| Readability | 0.001 g |
| Repeatability | ≤ ±1 mg |
| Construction | Stainless steel base with chemical-resistant housing |
| Power Options | AC adapter or rechargeable battery |
| Compliance | ISO/IEC 17025, ASTM E898, USP <41>, GLP/GMP-ready |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ML204T |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 100 g) |
| Internal Calibration | FACT (Fully Automatic Calibration Technology) |
| Weighing Pan Diameter | 90 mm |
| Display | 4.5" Color TFT Touchscreen |
| Stabilization Time | 2 s |
| Linearity Error (typ.) | ±0.2 mg |
| Minimum Weight (USP <0.1% RSD, typical) | 0.16 g |
| Power Supply | AC adapter + rechargeable Li-ion battery |
| Interface | RS232, USB Device, USB Host |
| Housing | Die-cast aluminum base + ABS plastic enclosure |
| Temperature Drift | ±2 ppm/°C |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Austria |
| Model | ML304T/02 |
| Maximum Capacity | 320 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Minimum Weight (USP) | 160 mg |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Calibration | Internal / FACT |
| Construction | Die-cast aluminum housing with ABS components |
| Interfaces | USB Host, USB Device, RS232, Optional Bluetooth |
| Weighing Unit | MonoBloc® High-Resolution Electromagnetic Force Compensation Sensor |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML54T |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 52 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Stabilization Time | 2 s |
| Minimum Weight (USP <41>) | 120 mg |
| Minimum Weight (U=1%, k=2) | 12 mg |
| Calibration | FACT fully automatic internal calibration |
| Leveling System | LevelControl with on-screen guidance |
| Weighing Pan Dimensions | 90 mm diameter |
| Display | 4.5-inch full-color capacitive touchscreen |
| Connectivity | USB Host, USB Device, RS232, optional Bluetooth |
| Data Transfer | PC Direct mode (no driver or software required) |
| Housing Material | ABS/PC top cover with metal base |
| Environmental Protection | IP42-rated enclosure |
| Power Options | AC adapter or rechargeable Li-ion battery (up to 8 h operation) |
| Compliance | ISO/IEC 17025 traceable calibration records, USP <41> and <1251> compliant, GLP/GMP-ready audit trail (ISO Log), 21 CFR Part 11 compatible with optional software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | ML54T/02 |
| Instrument Type | Analytical Balance |
| Maximum Capacity | 52 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg (at 50 g) |
| Minimum Weight (USP) | 0.16 g (typical) |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Calibration | Internal / FACT |
| Interface | RS232, USB Host & Device |
| Housing | Die-cast aluminum with ABS plastic |
| Dimensions (D×H×W) | 290 mm × 193 mm × ? mm |
| Legal for Trade | No |
| Hygienic Design | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MR Precision |
| Maximum Capacity | 100 g – 6.2 kg |
| Readability | 1 mg – 100 mg |
| Repeatability (5% load) | 0.7 mg – 7 mg (typical) |
| Linearity | 0.6 mg – 6 mg (typical) |
| Sensitivity Shift (nominal load) | 5 mg – 150 mg |
| Minimum Weight (USP, ±0.10%) | 1.4 g – 100 g |
| Stabilization Time | 1.0 – 1.5 s |
| Pan Diameter | 120 mm or 180 × 180 mm |
| Dimensions (W × D × H) | 209 × 351 × 354 mm or 209 × 351 × 100 mm |
| Interfaces | USB-A, USB-C, RS232, Ethernet |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MR Series (MR104, MR204, MR304) |
| Maximum Capacity | 120 g / 220 g / 320 g |
| Readability | 0.1 mg |
| Repeatability (5% load) | 0.08 mg (typical) |
| Linearity Error | 0.06 mg (typical) |
| Sensitivity Shift (nominal load) | 0.3–0.6 mg |
| Minimum Weight (USP <1251>, ±0.10% tolerance) | 60–160 mg |
| Stabilization Time | 2 s |
| Pan Diameter | 90 mm |
| Dimensions (W × D × H) | 209 × 351 × 354 mm |
| Weighing Principle | Electromagnetic Force Compensation (EMFC) |
| Calibration | FACT® Automatic Internal Calibration |
| Certifications | OIML R76, NTEP Class I |
| Interfaces | USB-A, USB-C, RS232, Ethernet |
| Software Compatibility | MT-SICS, EasyDirect™ |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | MR1002 Precision Balance |
| Protection Rating | IP43 |
| Construction | Full-metal housing with chemically resistant components |
| Overload Protection | Integrated sensor protection against mechanical shock and pan drop |
| Power Management | Configurable energy-saving mode |
| Connectivity | RS232, USB, Ethernet (optional), MT-SICS command protocol compliant |
| User Management | Role-based access control with customizable profiles |
| Compliance | Designed for GLP/GMP environments |