Add to compare
BrandTelaire
OriginUSA
Model7001
Instrument TypePortable
Detection TargetMulti-component (CO₂, Temperature)
CO₂ Range0–10,000 ppm
CO₂ Resolution1 ppm
Temperature Resolution0.1°C
Response Time≤60 s
Zero Drift≤20 ppm
Operating Temperature0–50°C
Storage Temperature−20–60°C
Calibration Interval12 months
OutputRS-232, 0–4 VDC analog (CO₂ & temperature)
Power4×AA alkaline batteries (80 h) or 6 VDC external adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelHX-1500
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCarbon Monoxide (CO)
Measurement RangesCO: 0.0–50 ppm (also configurable to 200 ppm or 1000 ppm)
Temperature−20–60 °C
Relative Humidity10–95 %RH
Resolution0.1 ppm
Repeatability≤1.0 %FS
Linearity Error≤±2 %FS
Zero DriftAuto-zero compensation
Span Drift≤±2 %FS / 3 h
Response Time (T90)≤60 s
Warm-up Time30 min
Flow Rate0.5–2.0 L/min
Power SupplyAC 220 V (±10 %) or rechargeable internal battery
Data InterfaceRS-485
Data Storage500 records
DisplayColor touchscreen LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7515
Instrument TypePortable
Resolution1 ppm
Response Time20 s
Measurement Range0–5000 ppm
Accuracy±3.0% of reading or ±50 ppm (whichever is greater)
Power Supply4 × AA batteries
Operating Temperature-20 to 60 °C
Dimensions (main unit)8.4 × 17.8 × 4.4 cm
Probe Dimensions7 cm length × 1.9 cm diameter
Sensor TechnologyDual-wavelength NDIR (Non-Dispersive Infrared)
CertificationCPA Pattern Approval Certificate (P.R. China)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelHX-2800
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR) Spectroscopy
Measurement RangeCO: 0–100 ppm, CO₂: 0–5000 ppm
ResolutionCO: 0.1 ppm, CO₂: 0.001% (10 ppm)
Linearity Error≤±2% FS
Repeatability≤1.0% FS
Zero Drift≤±2% FS/h
Span Drift≤±2% FS/3h
Response TimeCO ≤60 s, CO₂ ≤30 s
Preheat Time30 min
Flow Rate0.5–2.0 L/min
Digital InterfacesRS-232, USB, Modbus RTU via RS-485
Data Storage CapacityUp to 5000 measurement records
DisplayColor TFT touchscreen
Power SupplyAC 220 V (±10%) or rechargeable Li-ion battery
AlarmVisual and audible alarm with configurable thresholds
ComplianceGB/T 18204.23–2000, GB/T 9801–1988, GB/T 18204.24–2000, JJG 635–2011
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7525
CO₂ Sensor TypeDual-Wavelength NDIR
CO₂ Range0–5000 ppm
CO₂ Accuracy±3.0% of reading or ±50 ppm (whichever is greater)
CO₂ Resolution1 ppm
CO₂ Response Time20 s (t₉₀)
Temperature SensorThermistor
Temp Range0–60 °C
Temp Accuracy±0.5 °C
Temp Resolution0.1 °C
Temp Response Time30 s (at 2 m/s air velocity, t₉₀)
RH SensorThin-Film Capacitive
RH Range5–95 %RH
RH Accuracy±3.0 %RH
RH Resolution0.1 %RH
RH Response Time20 s (t₆₃)
Outdoor Air Percentage Calculation0–100 %
Resolution0.1 %
Operating Temperature5–45 °C
Storage Temperature−20–60 °C
Dimensions (Instrument)8.4 × 17.8 × 4.4 cm
Probe Length17.8 cm
Probe Diameter1.9 cm
Time Constants1, 5, 10, 20, 30 s
Logging Interval1 s to 1 hr (user-selectable)
Data Storage CapacityUp to 30,300 records
Weight (with batteries)0.27 kg
Power4 × AA batteries or optional AC adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY (Beijing Baoyun)
ModelBY-200-CO2
TypePortable Gas Analyzer
Detection PrincipleNDIR for CO₂
CO₂ Range0–10,000 ppm
CO₂ Resolution1 ppm
CO₂ Accuracy±(40 + 3% of reading) ppm
HCHO Range0.00–5.00 mg/m³
HCHO Resolution0.01 mg/m³
HCHO Accuracy±5%
Dimensions (Analyzer)165 × 80 × 30 mm
Sensor Module Size123 × 45 × 15 mm
DisplayColor TFT LCD
PowerReplaceable alkaline batteries
Data ConnectivityBluetooth-enabled smartphone app with cloud upload capability
Data LoggingInternal storage with query function
ComplianceDesigned for indoor air quality (IAQ) assessment per ISO 16814, ASHRAE Standard 62.1, and GB/T 18883–2022 (China IAQ guideline)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model7545
Measured ParametersCO₂, CO, Temperature, Relative Humidity
Derived ParametersDew Point Temperature, Wet-Bulb Temperature, Outdoor Air Fraction (calculated)
Sensor TechnologyNDIR (CO₂), Electrochemical (CO), Capacitive (RH), Thermistor (Temperature)
Data LoggingInternal memory with timestamped records
InterfaceUSB for data download via TSI LogDat2™ software
ComplianceDesigned to support ASHRAE 62.1, ISO 16814, and EN 13779 indoor air quality assessment protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY (Beijing Baoyun)
OriginBeijing, China
ModelHX-1200
Instrument TypePortable CO₂ Analyzer
Measurement Range0–10,000 ppm (extendable to 0–100% vol)
Detection PrincipleNon-Dispersive Infrared (NDIR)
Resolution1 ppm
Repeatability≤1% FS
Response Time (T₉₀)≤10 s
Data Storage256 measurement records with timestamp
Display3.5″ full-color TFT touchscreen
Communication InterfaceUSB 2.0
Power SupplyInternal rechargeable Li-ion battery (≥200 h continuous operation) / External: 9 VDC ±10% or 220 VAC ±10%
Operating Environment0–50 °C, 10–95% RH (non-condensing)
Dimensions205 × 180 × 98 mm
Weight1.2 kg
Output Unitsppm, mg/m³, °C, %RH (auto-convertible)
AlarmVisual (LED flash) & audible (≥85 dB at 30 cm)