Add to compare
BrandBJBY
OriginBeijing, China
ModelBY-800-HCHO
PrinciplePhotometric Colorimetry (GB/T 18204.2)
Measurement Range0.000–1.250 mg/m³
Resolution0.001 mg/m³
Sampling MethodConstant-Flow Sampling
Operating Temperature5–40 °C (±1 °C)
Relative Humidity Range≤90% RH (±2% RH)
Atmospheric Pressure Range30–120 kPa (±0.2 kPa)
Accuracy±5% of reading
Analysis Time10 min per sample
Display2.2-inch color LCD
Power Supply7.4 V rechargeable Li-ion battery
Data Storage8,000 records
ConnectivityBluetooth for wireless printing
ComplianceGB/T 18204.2–2014 (Public Health Inspection Methods – Part 2: Chemical Pollutants)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPPM (manufactured in UK)
OriginUnited Kingdom
ModelHTV-M
Detection PrincipleElectrochemical Sensor
Measurement Range0–30 ppm (max. 34 ppm)
Resolution≤0.01 ppm
Repeatability±2% of reading
Sampling MethodIntegrated micro-pump with one-button aspiration
Response Time≤50 s
Operating Temperature−40 to +128 °C
Relative Humidity Range0–100% RH
Temperature Accuracy±0.4 °C
Humidity Accuracy±3% RH
Battery3.6 V rechargeable Li-ion
Runtime~200 h continuous
Weight270 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTelaire
OriginUSA
Model7001
Instrument TypePortable
Detection TargetMulti-component (CO₂, Temperature)
CO₂ Range0–10,000 ppm
CO₂ Resolution1 ppm
Temperature Resolution0.1°C
Response Time≤60 s
Zero Drift≤20 ppm
Operating Temperature0–50°C
Storage Temperature−20–60°C
Calibration Interval12 months
OutputRS-232, 0–4 VDC analog (CO₂ & temperature)
Power4×AA alkaline batteries (80 h) or 6 VDC external adapter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model8525
Operating PrincipleCondensation Nucleus Counting (CNC) via Isopropanol-based Growth
Particle Size Range2 nm to >1 µm
Concentration Range0–5×10⁵ cm⁻³
Sample Flow Rate0.1 L/min
Total Flow Rate0.7 L/min
Operating Temperature0–38 °C
Storage Temperature−40 to 70 °C
Power Supply6 × AA batteries (6 h runtime at 21 °C)
Alcohol RequirementReagent-grade isopropanol (8 h per fill at 21 °C)
Data InterfaceRS-232 (9600 baud)
Internal Memory470 independent measurement points
Logging Interval1 min
Max Continuous Logging Duration1000 hours
Test ID Capacity141 unique IDs
Dimensions270 × 140 × 140 mm
Added to wishlistRemoved from wishlist 0
Add to compare
(ManufacturerUS-based distributor
OriginUSA
Instrument TypePortable
Model202
Detection PrincipleUV Absorption at 254 nm
Measurement Range0 ppb – 250 ppm
LOD3.0 ppb (critical value)
Response Time20 s (t₉₀, two-point)
Zero Drift<2 ppb/day, <5 ppb/year
Sensitivity Drift<1%/day, <3%/year
Resolution0.1 ppb
Accuracy±1.5 ppb or ±2% of reading (whichever is greater, 10-s mode)
Flow Rate1.0 L/min (min. required: 0.6 L/min)
Data Storage16,383 records
Operating Temperature0–50 °C standard
PowerRechargeable battery or 110/220 V AC adapter
Dimensions9.5 × 21.5 × 30 cm
Weight2.8 kg (instrument only), 1.3 kg (carrying case excluded))
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelBioSampler®
Flow Rate12.5 L/min
ConstructionBorosilicate Glass
SterilizationAutoclavable
Sampling DurationUp to 8 hours
Collection MediumAqueous or viscous liquid (e.g., ViaTrap® mineral oil)
Inlet/OutletStandard ground-glass joints
Compatible PumpSKC BioLite® sonic-flow pump
Nozzle ConfigurationTriple tangential jets at optimized angles
Particle Size Cut-offApprox. ≤10 µm aerodynamic diameter (human inhalable fraction)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
ModelDustTrak II 8532
Measurement Principle90° Light Scattering
Particle Size Range0.1–10 µm
Mass Concentration Range0.001–150 mg/m³
Resolution±0.1% of reading or 0.001 mg/m³ (whichever is greater)
Zero Stability±0.002 mg/m³ over 24 h (10-s averaging time)
Flow RateFactory-set at 3.0 L/min, user-adjustable from 1.40–3.0 L/min
Flow Accuracy±5% at factory-set point with internal flow control
Temperature Coefficient+0.001 mg/m³/°C
Selectable Fractional CutsPM₁, PM₂.₅, PM₄, PM₁₀ (integrated sharp-cut cyclones)
Data Memory5 MB (>60,000 data points at 1-min interval
Recording Interval1 s–1 h, programmable
Time Constant1–60 s, user-selectable
Operating Humidity0–95% RH (non-condensing)
Storage Temperature−20–60 °C
Dimensions (H×W×D)12.5 × 12.1 × 31.6 cm
Weight1.3 kg (bare), 1.5 kg (with Li-ion battery)
Display3.5″ VGA color touchscreen
PowerRechargeable lithium-ion battery (internal/external charging)
CertificationsCPA certified (UK), CE compliant (EN 61326-1:2006 for immunity & emissions)
AlarmVisual and audible (user-configurable setpoints, ±5% deadband)
InterfaceUSB port for data export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRiken
OriginJapan
ModelFP-30MK2(C)
Detection PrinciplePhotometric Colorimetry (based on acetylacetone reaction)
Measurement Range0.000–0.50 mg/m³ (TAB No.008)
Resolution0.01 mg/m³ (TAB No.008)
Repeatability≤ ±7% of reading
Sampling MethodPump-aspirated
Response Time900 s (15 min) for TAB No.009
Operating Temperature−10 to +40 °C
Operating Humidity≤90% RH (non-condensing)
Flow Rate0.5 L/min
Data Storage99 measurement records with timestamp
Power Supply4 × AA alkaline batteries
Battery LifeApprox. 12 h (at 20 °C, no backlight, no alarm)
Dimensions80 × 150 × 40 mm (W×H×D, excluding protrusions)
Weight~250 g (excluding batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelHAZ-DUST 7204
Sensor Type90° Optical Light Scattering (880 nm)
Measurement Range0.001–500 mg/m³ (1–500,000 µg/m³)
Resolution1 µg/m³
Accuracy±10% vs. gravimetric filter mass (SAE Fine Test Dust, ISO 12103-1 A2)
PM Size Coverage0.1–100 µm
Cut-Point CompatibilityIOM (2.0 L/min), GS-3 Cyclone (2.75 L/min, 4 µm), Thoracic (2.0 L/min), Chest (2.0 L/min)
Flow Control1–5 L/min, maintained within ±5% across backpressures up to 70 inH₂O
Display3.5″ 24-bit resistive color touchscreen with auto-brightness
BatteryRechargeable Li-ion (7.4 V, 3350 mAh)
Operating Temp0–50 °C
Humidity0–95% RH non-condensing
Data Storage43,200 points
Sampling Intervals1, 4, 10, or 60 s
ComplianceCEN/ISO 7708, OSHA Silica Rule (29 CFR 1926.1153), MSHA DPM standards
SoftwareDustComm Pro (Windows 10+)
CertificationsCE, UL, CB, CUL, PSE, RCM
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCORTEST
OriginJapan
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelGASTEC Tube-Type Gas Detector
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelIMPACT
Flow Rate10 L/min
Filter Diameter47 mm
Compatible PumpLeland Legacy (recommended)
Sampling TargetPM₁₀, PM₂.₅, and PM₁₀–₂.₅ fractionated collection
Impact SubstratePre-oiled disposable impaction plate
DesignRemovable filter holder, rain shield optional, rapid-mount bracket optional
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model9306-V
Particle Size Range0.3–10 µm
Flow Rate2.83 L/min (0.1 ft³/min)
Channel ConfigurationUser-Selectable Six-Channel Detection
ComplianceISO 21501-4, ISO 14644-1, EU GMP Annex 1, FS209E, JIS B9921, CE
Data Storage10,000 records (250 locations)
Display9.1 cm QVGA color touchscreen
Battery Life6 h (rechargeable Li-ion)
CommunicationUSB 2.0 & Ethernet (Modbus® RTU)
Operating Temperature5–35 °C, Non-condensing RH 20–95%
Dimensions23.9 × 11.7 × 12.4 cm (H×L×W, incl. handle)
Weight1.0 kg (with battery)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelAirChek52
Flow Range5–3000 mL/min (5–500 mL/min with Low-Flow Kit)
Backpressure CompensationUp to 25 in. H₂O
Operating Time>8 h at 2000 mL/min & 25 in. H₂O
Flow Accuracy±5% after calibration
Weight566 g
Dimensions12.7 × 7.6 × 4.4 cm
DisplayLCD showing sampling time, flow status, low-battery warning, and flow error alert
Auto-ShutoffEnabled upon ±5% flow deviation
Safety CertificationUL & cUL Listed
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelPocket Pump TOUCH (220-1000TC)
Flow Range20–500 mL/min (constant-flow mode)
Backpressure CompensationUp to 20 in. H₂O
Flow Stability±5% of setpoint or ±3 mL/min, whichever is greater
Flowmeter Accuracy±0.5% of reading
Operating Time≥20 hours at maximum flow and backpressure
Power SourceRechargeable Li-ion battery (3.6 V, 2.6 Ah)
Dimensions8.1 × 9.7 × 3.8 cm
Weight235 g
Ingress ProtectionIP64
CertificationsCE, UL Intrinsically Safe
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelBY-300
Flow Range0–30 L/min
Flow AccuracyClass 2.5
Sampling PrincipleImpaction
Timer Range1–99 min
Negative Pressure≥2000 Pa
Capture Efficiency≥98%
Power SupplyRechargeable Li-ion battery (5 h runtime) + AC/DC adapter (220 V, 50 Hz)
Weight2.0 kg
Dimensions20 × 13.5 × 14 cm
Sampler Head6-stage Anderson-style impactor (Aluminum alloy, rubber-gasketed stages)
Particle Size CutoffsStage 1: >7.0 µm
Stage 24.7–7.0 µm
Stage 33.3–4.7 µm
Stage 42.1–3.3 µm
Stage 51.1–2.1 µm
Stage 60.65–1.1 µm
Collection MediumStandard 90 mm Petri dishes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRIKEN KEIKI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTAB-008 / TAB-009
PricingUpon Request
Detection PrinciplePhotometric Colorimetry
Sampling MethodPump-Driven Active Inhalation
Flow Rate0.5 L/min
Measurement Range0.000–0.500 mg/m³ (TAB-008)
Display Resolution0.01 mg/m³ (TAB-008)
Integration Time1800 s (30 min) for TAB-008
Pack Size20 strips per pack
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelSioutas Impactor
Flow Rate9 L/min
Cut Points2.5 µm, 1.0 µm, 0.5 µm, 0.25 µm
Collection Substrate25 mm PTFE filters (stages 1–4), optional 37 mm backup filter (<0.25 µm)
Pressure DropLow at 9 L/min for 24-h sampling
ComplianceDesigned for OSHA, NIOSH, and ISO 7708-compliant personal aerosol monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelHX-1500
Instrument TypePortable
Detection PrincipleNon-Dispersive Infrared (NDIR)
Target GasCarbon Monoxide (CO)
Measurement RangesCO: 0.0–50 ppm (also configurable to 200 ppm or 1000 ppm)
Temperature−20–60 °C
Relative Humidity10–95 %RH
Resolution0.1 ppm
Repeatability≤1.0 %FS
Linearity Error≤±2 %FS
Zero DriftAuto-zero compensation
Span Drift≤±2 %FS / 3 h
Response Time (T90)≤60 s
Warm-up Time30 min
Flow Rate0.5–2.0 L/min
Power SupplyAC 220 V (±10 %) or rechargeable internal battery
Data InterfaceRS-485
Data Storage500 records
DisplayColor touchscreen LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelAirChek XR5000
Flow Range5–5000 mL/min
Power OptionsHigh-Capacity Li-ion (4-cell, 7.4 V, 4.4 Ah), Standard Li-ion (2-cell, 7.4 V, 2.2 Ah), or Alkaline Batteries
Accuracy±5% of set flow rate with active backpressure compensation
Operating Temperature0–45 °C
Storage Temperature−20–45 °C
Timer Range1–9999 min (6.8 days)
ComplianceCE-marked, RFI/EMI-shielded for use in hazardous locations, UL-listed
Safety FeaturesAuto-shutdown on sustained low-flow (<15 s recovery), 5-attempt auto-restart sequence, low-battery sleep mode after 15 s idle, automatic pump stop after 5 min inactivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelPMI Series
Flow Rate3 L/min
Cut-Point10 µm (PM₁₀) or 2.5 µm (PM₂.₅)
Filter Diameter37 mm
Impactor Substrate25 mm disposable pre-oiled porous plastic disk
Weight71 g
ComplianceEPA-defined PM₂.₅ and PM₁₀ sampling criteria
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscan
OriginUSA
Model8160
Detection PrincipleElectrochemical Sensor
Measurement Range0–20.00 ppm (0–2000 ppb)
Resolution0.01 ppm / 1 ppb
Repeatability±0.5% of reading
Accuracy±2% Rd + 0.01 ppm
Response Time<60 s
Linearity Error±1.0% (24 h)
Zero Drift±1.0% (24 h)
Span Drift≤±2.0% (24 h)
Sampling MethodContinuous pump-suction
DisplayLCD with real-time graphing and data logging
Analog Outputs4–20 mA and 0–2.5 V
Battery LifeUp to 8 h (rechargeable Li-ion)
Operating Environment0–45 °C, 0–90% RH
Dimensions140 × 210 × 254 mm
Weight2.95 kg
EnclosureAnodized aluminum housing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelAirLite®
Flow Range5–3000 mL/min (5–500 mL/min with optional Low-Flow Kit)
Backpressure CompensationUp to 30 in. H₂O
Battery Life≥8 hours at full flow range using alkaline AA batteries
Flow Accuracy±5% after calibration
Weight340 g
Dimensions10.1 × 7.9 × 4.8 cm
Power SupplyTwo 1.5 V AA alkaline batteries
DisplayLED indicators for sampling status, flow condition, and low-battery warning
Auto-ShutdownActivates when flow error exceeds ±5%
Built-inFlow pulse dampener, particulate filter
External MountingDedicated orifice for impactor bottle bracket
EMI/RFI ShieldingConductive polymer housing compliant with IEC 61000-4 series immunity standards
CertificationsMeets OSHA, NIOSH, and ISO 13137 requirements for personal air sampling pumps
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelIOM
Sampling Flow Rate2 L/min
50% Cut-Point100 µm (at 2 L/min)
Filter Diameter25 mm
Housing MaterialHeat-resistant polypropylene (plastic) or stainless steel
Max Operating Temperature100 °C (plastic), 200 °C (stainless steel)
Weight<55 g (plastic version, including cassette)
Dimensions8.5 × 2.8 cm
Inlet Tubing ID6.25 mm (1/4″)
ComplianceACGIH Inhalable Fraction, ISO/CEN EN 13205, HSE MDHS 14/4, MDHS 6/3 (with accessory head), MDHS 25/3 (stainless only), NIOSH Method 5700, OSHA PNOR, Australian Inhalable PM Standard
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelImpingers
PricingUpon Request