Empowering Scientific Discovery

Beijing Baoyun Xingye Science & Trade Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelBY-800-HCHO
PrinciplePhotometric Colorimetry (GB/T 18204.2)
Measurement Range0.000–1.250 mg/m³
Resolution0.001 mg/m³
Sampling MethodConstant-Flow Sampling
Operating Temperature5–40 °C (±1 °C)
Relative Humidity Range≤90% RH (±2% RH)
Atmospheric Pressure Range30–120 kPa (±0.2 kPa)
Accuracy±5% of reading
Analysis Time10 min per sample
Display2.2-inch color LCD
Power Supply7.4 V rechargeable Li-ion battery
Data Storage8,000 records
ConnectivityBluetooth for wireless printing
ComplianceGB/T 18204.2–2014 (Public Health Inspection Methods – Part 2: Chemical Pollutants)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPPM (manufactured in UK)
OriginUnited Kingdom
ModelHTV-M
Detection PrincipleElectrochemical Sensor
Measurement Range0–30 ppm (max. 34 ppm)
Resolution≤0.01 ppm
Repeatability±2% of reading
Sampling MethodIntegrated micro-pump with one-button aspiration
Response Time≤50 s
Operating Temperature−40 to +128 °C
Relative Humidity Range0–100% RH
Temperature Accuracy±0.4 °C
Humidity Accuracy±3% RH
Battery3.6 V rechargeable Li-ion
Runtime~200 h continuous
Weight270 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRiken
OriginJapan
ModelFP-30MK2(C)
Detection PrinciplePhotometric Colorimetry (based on acetylacetone reaction)
Measurement Range0.000–0.50 mg/m³ (TAB No.008)
Resolution0.01 mg/m³ (TAB No.008)
Repeatability≤ ±7% of reading
Sampling MethodPump-aspirated
Response Time900 s (15 min) for TAB No.009
Operating Temperature−10 to +40 °C
Operating Humidity≤90% RH (non-condensing)
Flow Rate0.5 L/min
Data Storage99 measurement records with timestamp
Power Supply4 × AA alkaline batteries
Battery LifeApprox. 12 h (at 20 °C, no backlight, no alarm)
Dimensions80 × 150 × 40 mm (W×H×D, excluding protrusions)
Weight~250 g (excluding batteries)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRIKEN KEIKI
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelTAB-008 / TAB-009
PricingUpon Request
Detection PrinciplePhotometric Colorimetry
Sampling MethodPump-Driven Active Inhalation
Flow Rate0.5 L/min
Measurement Range0.000–0.500 mg/m³ (TAB-008)
Display Resolution0.01 mg/m³ (TAB-008)
Integration Time1800 s (30 min) for TAB-008
Pack Size20 strips per pack
Added to wishlistRemoved from wishlist 0
Add to compare
BrandInterscan
OriginUSA
Model8160
Detection PrincipleElectrochemical Sensor
Measurement Range0–20.00 ppm (0–2000 ppb)
Resolution0.01 ppm / 1 ppb
Repeatability±0.5% of reading
Accuracy±2% Rd + 0.01 ppm
Response Time<60 s
Linearity Error±1.0% (24 h)
Zero Drift±1.0% (24 h)
Span Drift≤±2.0% (24 h)
Sampling MethodContinuous pump-suction
DisplayLCD with real-time graphing and data logging
Analog Outputs4–20 mA and 0–2.5 V
Battery LifeUp to 8 h (rechargeable Li-ion)
Operating Environment0–45 °C, 0–90% RH
Dimensions140 × 210 × 254 mm
Weight2.95 kg
EnclosureAnodized aluminum housing