Empowering Scientific Discovery

Beijing Baoyun Xingye Science & Trade Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMedcom
OriginUSA
ModelRadalert100
Detection PrincipleHalogen-quenched Geiger-Müller tube
Energy Range20 keV – 3 MeV
Dose Rate Range (mR/hr)0.001 – 110.0
Dose Rate Range (µSv/hr)0.01 – 1100
Count Rate (CPM)0 – 350,000
Count Rate (CPS)0 – 3,500
Total Count Capacity1 – 9,999,000
Calibration Source¹³⁷Cs (γ)
Sensitivity1,000 CPM per mR/hr (referenced to ¹³⁷Cs)
Accuracy±10% typical, ±15% maximum
Display4-digit LCD with mode indicators
Audio/Visual AlertUser-adjustable threshold, LED flash per count
Interface3.5 mm output jack (0–9 V, 1 kΩ impedance), 2.5 mm calibration input
Power9 V alkaline battery (≥700 h typical life)
Dimensions150 × 80 × 30 mm
Weight323 g (including battery)
ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPolimaster
OriginUSA
ModelPM1208M
Instrument TypePortable
Measurement TypeAmbient Dose Equivalent Rate (H*(10)) and Cumulative Ambient Dose Equivalent (H*(10))
Dose Rate Range0.01–9999.99 µSv/h
Dose Range0.001–9999.99 mSv
Energy Response0.06–1.5 MeV
Waterproof RatingIP68 (100 m submersion)
DisplayDual-mode LCD with electroluminescent backlight
Data StorageNon-volatile memory
CommunicationInfrared (IR) interface compliant with ISO/IEC 14443
AlarmAudible and visual threshold alerts for dose rate and cumulative dose
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIMI Medcom
OriginUSA
ModelInspector
Detection PrincipleGeiger-Müller (GM) Tube with Mica End-Window
Radiation TypesAlpha (α), Beta (β), Gamma (γ), and X-ray
DisplayDigital LCD
DetectorInternal GM tube (45 mm effective mica window diameter)
Power SupplyOne 9V alkaline battery (typical life: 200 hours)
TimerAdjustable built-in timer
CalibrationExternal calibration port
ComplianceDesigned for field-deployable radiation safety surveys per ANSI N42.33, IEC 60846, and ISO 4037-3 guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY (Beijing Baoyun)
ModelWBGT-2006
OriginImported (U.S.-sourced instrumentation platform)
ComplianceGB/T 4200–2008, ISO 7243:1989
Measurement PrincipleSimultaneous dry-bulb, natural wet-bulb, and black-globe temperature acquisition for WBGT index calculation
DisplayReal-time concurrent readout of T<sub>db</sub>, T<sub>nwb</sub>, T<sub>g</sub>, and WBGT value
Data LoggingUp to 100 hours internal storage
InterfaceUSB 2.0 for PC connectivity
SoftwareDedicated Windows-based analysis suite supporting max/min/avg extraction per user-defined time segment
Operating MenuFull Chinese GUI (host unit only)
Sensor TypeDigital precision thermistors with direct digital output
Dry-Bulb Range10–60 °C ±0.5 °C
Natural Wet-Bulb Range5–40 °C ±0.5 °C
Black-Globe Range20–120 °C (±0.5 °C @ 20–40 °C
Globe Diameter150 mm, Emissivity ≥0.95
Wet-Bulb WickingCylindrical cotton sleeve (6±1 mm OD, 30±5 mm length), 20–30 mm free hanging length, water reservoir isolation from radiant heating
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunnuclear
OriginUSA
Model1028 XP
Sampling MethodActive Airflow
Detection Limit0.1 pCi/L
Detection PrincipleElectrostatic Collection
Sensitivity2.7 cph per pCi/L
Measurement Range0.1–9999 pCi/L (3.7–370,000 Bq/m³)
Uncertainty (24-hr)±7%
Display2.8" Color TFT Touchscreen
Data Storage10,000 Records
Battery Life~300 h (4×AA Alkaline)
Dimensions19 × 12 × 7.3 cm
Weight616 g
CertificationsNRPP, C-NRPP, NRSB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFluke
OriginUSA
Model451P
Detection PrinciplePressurized ionization chamber (300 cm³, 6 atm)
Radiation Typesγ-rays and X-rays ≥25 keV
Measurement Ranges0–500 μR/h to 0–5 R/h (or equivalent in Sv: 0–5 μSv/h to 0–50 mSv/h)
Accuracy±10% of reading (10–100% of full scale), calibrated with ¹³⁷Cs
Response Time1.8–4.8 s (10%–90% rise time, dependent on range and dose rate)
PowerTwo 9 V alkaline batteries (200 h typical life)
Operating Environment–20 °C to +50 °C, 0–100% RH
Dimensions10 × 20 × 15 cm (4 × 8 × 6 in)
Weight1.07 kg (2 lb 6 oz)
DisplayAnalog bar graph (100-segment, 6.4 cm) + 2.5-digit LCD with backlight
InterfaceRS-232 for PC connectivity
ComplianceDesigned for use in accordance with ANSI N42.17A, IEC 60846, and applicable radiation safety practices per NRC and IAEA guidance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelBY-2020-2
Black Globe Temp. Range0–120 °C, ±0.5 °C
Wet-Bulb Temp. Range0–50 °C, ±0.5 °C
Ambient Temp./RH Sensor−20–120 °C / 0–100% RH, ±0.5 °C / ±3% RH
Display3.5″ color touch LCD
Power5000 mAh Li-ion, ≥96 h standby
EnclosureABS + overmolded TPE, IP30
Mounting1/4″ tripod thread
ConnectivityM12 digital ports (3×), K-type thermocouple (2×), analog inputs (2×, 0–2 V), Bluetooth 5.0 (≥20 devices), USB-C, Wi-Fi, microSD slot
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelBarracudaX
Instrument TypeLaboratory Spectrometer
Measurement MediumX-ray Generators and Radiotherapy Equipment
CertificationPTB Certified, CE 413 (MDD Directive), Class IIa Medical Device
Sampling Rate470 kHz
KeyValue
KeyValue
Added to wishlistRemoved from wishlist 0
Add to compare
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelHI-2200
PricingUpon Request
Operating Temperature−10 °C to 50 °C
Host Dimensions85 mm × 160 mm × 30 mm
Probe Height260 mm
Weight0.6 kg
Data Logging Capacity65,000 readings
Display Units (E-field)V/m, μW/cm², mW/cm², W/m²
Display Units (H-field)A/m, mA/m, μW/cm², mW/cm², W/m²
E100 ProbeIsotropic E-field sensor, 100 kHz–5 GHz, 0.3–800 V/m
H200 ProbeIsotropic H-field sensor, 5 MHz–300 MHz, 0.3–10 A/m
H210 ProbeIsotropic H-field sensor, 300 kHz–30 MHz, 0.3–30 A/m
C300 ProbeE-field % of FCC exposure limits, 100 kHz–8 GHz
C310 ProbeE-field % of ICNIRP exposure limits, 100 kHz–8 GHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY (Beijing Baoyun)
ModelC222
Lead Equivalence (Front)0.35 mm Pb or 0.5 mm Pb
Lead Equivalence (Back & Sleeves)0.25 mm Pb
Overlap Design (Front Closure)Hook-and-Loop (0.7 mm Pb) or Snap Fastener (1.0 mm Pb)
Shoulder PaddingIntegrated Soft Foam Cushioning
Waist SupportAdjustable Wide Elastic Belt
Color Options12 Standard Colors
Size Range17 Standard Sizes
ComplianceMeets IEC 61331-1:2014 and GBZ 130-2020 Requirements for Diagnostic Radiology Protective Apparel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
ModelBY-EM01
Frequency Range1 Hz – 60 GHz (probe-dependent)
Measurement ParametersElectric Field Strength (V/m, kV/m), Magnetic Field Strength (A/m, µT, mT), Power Density (µW/cm², mW/cm²)
Probe CompatibilityFour dedicated probe types (LF, HF, UHF, MW) with triaxial isotropic sensors
Operating Environment-20 °C to +55 °C, IP65 (host), IP52 (probes)
Battery Life>8 h (host), >10 h (LF probe), >3 h (HF probe)
Data ModesReal-time, RMS, Max, Time History, Spectrum Analysis, 8-h Weighted Average
ComplianceGBZ/T 189.1–189.5, GBZ 2.2, GB 8702, HJ 681, HJ 972, HJ 1136, HJ 1199, IEC 61786-1, IEC 62232, GJB 5313A
ConnectivityFiber-optic (primary), Bluetooth 4.1, USB-C, GPS+AGPS
Display6.0" 1080p LCD, Android-based touch interface
Dimensions (host)165.5 × 81.6 × 29.1 mm
Weight (host)335 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelBY-2020-3
Black Globe Temperature Sensor (2020-11)Range 0–120°C, Accuracy ±0.5°C, Resolution 0.1°C, Stainless Steel Enclosure
Ambient Temperature & Humidity Sensor (2020-16)Temp Range −20–120°C, Accuracy ±0.5°C
Anemometer (2020-21)Range 0–10 m/s, Accuracy ±(0.05 + 0% of reading) for 0.05–2 m/s, ±(0.1 + 2% of reading) above 2 m/s, Resolution 0.01 m/s, RS485 Output
Display3.5-inch Color Touch LCD
PowerInternal 5000 mAh Li-ion Battery (≥96 h standby), DC5V/1A Micro USB Input
Data StorageRemovable SD Card, CSV Export
CommunicationRS485, USB, Wi-Fi, Bluetooth (up to 20 BLE sensors), M12 6-pin Aviation Connectors (3 digital channels), K-type Thermocouple Inputs (2), Analog Inputs (2, 0–2 V, 0.01 mV resolution, ±0.5% accuracy)
EnclosureABS + TPU Overmold, IP30 Rating, 175 × 92 × 38 mm, 1/4″ Tripod Thread, Detachable Wrist Strap
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSunnuclear
OriginUSA
Model1030
Detector TypeDiffusion-based silicon photodiode (6-channel)
Measurement Interval Options0.5, 1, 2, 4, 8, 12, 16, 20, 24 h
Delay Options0, 12, 24, 48 h
Duration Options1–100 days or long-term mode (up to 1650 measurement intervals
Sensitivity15 cph per pCi/L
Accuracy±20% relative to NIST SRM 4973
Operating Temperature7–35 °C (45–95 °F)
Relative Humidity Range0–95% RH
Pressure Range69–103 kPa (20.4–30.5 inHg)
Radon Measurement Range0.1–9999 pCi/L (3.7–369,996 Bq/m³)
Display16-character LCD with 6-button interface
Power4× C-cell alkaline batteries (≥350 h runtime) or 5 V DC USB adapter (110–230 V AC, 50/60 Hz)
Dimensions (W×L×H)5.5×9.6×4.4 in
Weight3.75 lb
Environmental SensorsIntegrated temperature (±1 °C), humidity (±5% RH, 1% resolution), pressure (±3.4 kPa, 0.14 kPa resolution)
CertificationsNRSB, NRPP, and C-NRPP accredited
Data InterfaceUSB 2.0 (cable included)
Storage Slots2 independent test slots
Tamper DetectionBuilt-in sensor
MountingStandard tripod thread (¼"-20)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMedcom
OriginUSA
ModelCRM-100
Detector TypeHalogen-quenched Geiger-Müller tube with mica end-window (45 mm diameter, 1.5–2.0 mg/cm² density)
Radiation Types DetectedAlpha, Beta, Gamma, and X-ray
Energy Range20 keV – 3 MeV
Dose Rate Range0.001–110.0 mR/h or 0.01–1100 µSv/h
Count Rate Range0–3,500 CPS / 0–350,000 CPM
Total Count CapacityUp to 9,999,000 counts
Timer RangeUp to 40 hours
Sensitivity≥1,000 CPM per mR/h (referenced to Cs-137)
Accuracy±10% typical, ±15% maximum (mR/h and µSv/h modes)
Audio FeedbackClick-per-count (user-muteable)
Display4-digit LCD with mode indicators
Output Interface3.5 mm mono jack (CMOS-compatible TTL pulse output)
Input Interface2.5 mm calibration input port
PowerOne 9 V alkaline battery (typical life: 2,160 hours)
Dimensions150 × 80 × 30 mm
Weight225 g (including battery)
CertificationsCE, RoHS, WEEE, ISO 9001:2001 & ISO 14001
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBJBY
OriginBeijing, China
ModelJC-RAD-14
Sampling MethodActive Pump-aspiration
Measurement RangeAir Radon: 3–150,000 Bq/m³
Soil Radon300–400,000 Bq/m³
Radon Exhalation Rate0.001–10.000 Bq/(m²·s)
Water Radon0.003–100 Bq/L
Detection Repeatability≤5% (at 1800 Bq/m³, 65% RH, 25°C)
8-h Drift≤10%
PowerRechargeable Li-ion battery (≥30 h continuous operation) or AC adapter
Operating Temperature−10°C to +40°C
Relative Humidity≤98% RH
DisplayBacklit dot-matrix LCD
Data Storage>200,000 records
Flow RateUp to 3 L/min (peak)
Communication InterfacesUSB, RS232, RS485, TCP/IP, Industrial Wireless
Inlet/Outlet FittingsAnodized Aluminum
Self-background Count Rate≤0.3 cpm
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0