- All
- Favorite
- Popular
- Most rated
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | Radalert100 |
| Detection Principle | Halogen-quenched Geiger-Müller tube |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range (mR/hr) | 0.001 – 110.0 |
| Dose Rate Range (µSv/hr) | 0.01 – 1100 |
| Count Rate (CPM) | 0 – 350,000 |
| Count Rate (CPS) | 0 – 3,500 |
| Total Count Capacity | 1 – 9,999,000 |
| Calibration Source | ¹³⁷Cs (γ) |
| Sensitivity | 1,000 CPM per mR/hr (referenced to ¹³⁷Cs) |
| Accuracy | ±10% typical, ±15% maximum |
| Display | 4-digit LCD with mode indicators |
| Audio/Visual Alert | User-adjustable threshold, LED flash per count |
| Interface | 3.5 mm output jack (0–9 V, 1 kΩ impedance), 2.5 mm calibration input |
| Power | 9 V alkaline battery (≥700 h typical life) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 323 g (including battery) |
| Compliance | CE-marked |
| Brand | Polimaster |
|---|---|
| Origin | USA |
| Model | PM1208M |
| Instrument Type | Portable |
| Measurement Type | Ambient Dose Equivalent Rate (H*(10)) and Cumulative Ambient Dose Equivalent (H*(10)) |
| Dose Rate Range | 0.01–9999.99 µSv/h |
| Dose Range | 0.001–9999.99 mSv |
| Energy Response | 0.06–1.5 MeV |
| Waterproof Rating | IP68 (100 m submersion) |
| Display | Dual-mode LCD with electroluminescent backlight |
| Data Storage | Non-volatile memory |
| Communication | Infrared (IR) interface compliant with ISO/IEC 14443 |
| Alarm | Audible and visual threshold alerts for dose rate and cumulative dose |
| Brand | IMI Medcom |
|---|---|
| Origin | USA |
| Model | Inspector |
| Detection Principle | Geiger-Müller (GM) Tube with Mica End-Window |
| Radiation Types | Alpha (α), Beta (β), Gamma (γ), and X-ray |
| Display | Digital LCD |
| Detector | Internal GM tube (45 mm effective mica window diameter) |
| Power Supply | One 9V alkaline battery (typical life: 200 hours) |
| Timer | Adjustable built-in timer |
| Calibration | External calibration port |
| Compliance | Designed for field-deployable radiation safety surveys per ANSI N42.33, IEC 60846, and ISO 4037-3 guidelines |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Model | WBGT-2006 |
| Origin | Imported (U.S.-sourced instrumentation platform) |
| Compliance | GB/T 4200–2008, ISO 7243:1989 |
| Measurement Principle | Simultaneous dry-bulb, natural wet-bulb, and black-globe temperature acquisition for WBGT index calculation |
| Display | Real-time concurrent readout of T<sub>db</sub>, T<sub>nwb</sub>, T<sub>g</sub>, and WBGT value |
| Data Logging | Up to 100 hours internal storage |
| Interface | USB 2.0 for PC connectivity |
| Software | Dedicated Windows-based analysis suite supporting max/min/avg extraction per user-defined time segment |
| Operating Menu | Full Chinese GUI (host unit only) |
| Sensor Type | Digital precision thermistors with direct digital output |
| Dry-Bulb Range | 10–60 °C ±0.5 °C |
| Natural Wet-Bulb Range | 5–40 °C ±0.5 °C |
| Black-Globe Range | 20–120 °C (±0.5 °C @ 20–40 °C |
| Globe Diameter | 150 mm, Emissivity ≥0.95 |
| Wet-Bulb Wicking | Cylindrical cotton sleeve (6±1 mm OD, 30±5 mm length), 20–30 mm free hanging length, water reservoir isolation from radiant heating |
| Brand | Sunnuclear |
|---|---|
| Origin | USA |
| Model | 1028 XP |
| Sampling Method | Active Airflow |
| Detection Limit | 0.1 pCi/L |
| Detection Principle | Electrostatic Collection |
| Sensitivity | 2.7 cph per pCi/L |
| Measurement Range | 0.1–9999 pCi/L (3.7–370,000 Bq/m³) |
| Uncertainty (24-hr) | ±7% |
| Display | 2.8" Color TFT Touchscreen |
| Data Storage | 10,000 Records |
| Battery Life | ~300 h (4×AA Alkaline) |
| Dimensions | 19 × 12 × 7.3 cm |
| Weight | 616 g |
| Certifications | NRPP, C-NRPP, NRSB |
| Brand | Fluke |
|---|---|
| Origin | USA |
| Model | 451P |
| Detection Principle | Pressurized ionization chamber (300 cm³, 6 atm) |
| Radiation Types | γ-rays and X-rays ≥25 keV |
| Measurement Ranges | 0–500 μR/h to 0–5 R/h (or equivalent in Sv: 0–5 μSv/h to 0–50 mSv/h) |
| Accuracy | ±10% of reading (10–100% of full scale), calibrated with ¹³⁷Cs |
| Response Time | 1.8–4.8 s (10%–90% rise time, dependent on range and dose rate) |
| Power | Two 9 V alkaline batteries (200 h typical life) |
| Operating Environment | –20 °C to +50 °C, 0–100% RH |
| Dimensions | 10 × 20 × 15 cm (4 × 8 × 6 in) |
| Weight | 1.07 kg (2 lb 6 oz) |
| Display | Analog bar graph (100-segment, 6.4 cm) + 2.5-digit LCD with backlight |
| Interface | RS-232 for PC connectivity |
| Compliance | Designed for use in accordance with ANSI N42.17A, IEC 60846, and applicable radiation safety practices per NRC and IAEA guidance |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-2020-2 |
| Black Globe Temp. Range | 0–120 °C, ±0.5 °C |
| Wet-Bulb Temp. Range | 0–50 °C, ±0.5 °C |
| Ambient Temp./RH Sensor | −20–120 °C / 0–100% RH, ±0.5 °C / ±3% RH |
| Display | 3.5″ color touch LCD |
| Power | 5000 mAh Li-ion, ≥96 h standby |
| Enclosure | ABS + overmolded TPE, IP30 |
| Mounting | 1/4″ tripod thread |
| Connectivity | M12 digital ports (3×), K-type thermocouple (2×), analog inputs (2×, 0–2 V), Bluetooth 5.0 (≥20 devices), USB-C, Wi-Fi, microSD slot |
| Brand | BJBY |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | BarracudaX |
| Instrument Type | Laboratory Spectrometer |
| Measurement Medium | X-ray Generators and Radiotherapy Equipment |
| Certification | PTB Certified, CE 413 (MDD Directive), Class IIa Medical Device |
| Sampling Rate | 470 kHz |
| Key | Value |
| Key | Value |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HI-2200 |
| Pricing | Upon Request |
| Operating Temperature | −10 °C to 50 °C |
| Host Dimensions | 85 mm × 160 mm × 30 mm |
| Probe Height | 260 mm |
| Weight | 0.6 kg |
| Data Logging Capacity | 65,000 readings |
| Display Units (E-field) | V/m, μW/cm², mW/cm², W/m² |
| Display Units (H-field) | A/m, mA/m, μW/cm², mW/cm², W/m² |
| E100 Probe | Isotropic E-field sensor, 100 kHz–5 GHz, 0.3–800 V/m |
| H200 Probe | Isotropic H-field sensor, 5 MHz–300 MHz, 0.3–10 A/m |
| H210 Probe | Isotropic H-field sensor, 300 kHz–30 MHz, 0.3–30 A/m |
| C300 Probe | E-field % of FCC exposure limits, 100 kHz–8 GHz |
| C310 Probe | E-field % of ICNIRP exposure limits, 100 kHz–8 GHz |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Model | C222 |
| Lead Equivalence (Front) | 0.35 mm Pb or 0.5 mm Pb |
| Lead Equivalence (Back & Sleeves) | 0.25 mm Pb |
| Overlap Design (Front Closure) | Hook-and-Loop (0.7 mm Pb) or Snap Fastener (1.0 mm Pb) |
| Shoulder Padding | Integrated Soft Foam Cushioning |
| Waist Support | Adjustable Wide Elastic Belt |
| Color Options | 12 Standard Colors |
| Size Range | 17 Standard Sizes |
| Compliance | Meets IEC 61331-1:2014 and GBZ 130-2020 Requirements for Diagnostic Radiology Protective Apparel |
| Brand | BJBY |
|---|---|
| Model | BY-EM01 |
| Frequency Range | 1 Hz – 60 GHz (probe-dependent) |
| Measurement Parameters | Electric Field Strength (V/m, kV/m), Magnetic Field Strength (A/m, µT, mT), Power Density (µW/cm², mW/cm²) |
| Probe Compatibility | Four dedicated probe types (LF, HF, UHF, MW) with triaxial isotropic sensors |
| Operating Environment | -20 °C to +55 °C, IP65 (host), IP52 (probes) |
| Battery Life | >8 h (host), >10 h (LF probe), >3 h (HF probe) |
| Data Modes | Real-time, RMS, Max, Time History, Spectrum Analysis, 8-h Weighted Average |
| Compliance | GBZ/T 189.1–189.5, GBZ 2.2, GB 8702, HJ 681, HJ 972, HJ 1136, HJ 1199, IEC 61786-1, IEC 62232, GJB 5313A |
| Connectivity | Fiber-optic (primary), Bluetooth 4.1, USB-C, GPS+AGPS |
| Display | 6.0" 1080p LCD, Android-based touch interface |
| Dimensions (host) | 165.5 × 81.6 × 29.1 mm |
| Weight (host) | 335 g |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | BY-2020-3 |
| Black Globe Temperature Sensor (2020-11) | Range 0–120°C, Accuracy ±0.5°C, Resolution 0.1°C, Stainless Steel Enclosure |
| Ambient Temperature & Humidity Sensor (2020-16) | Temp Range −20–120°C, Accuracy ±0.5°C |
| Anemometer (2020-21) | Range 0–10 m/s, Accuracy ±(0.05 + 0% of reading) for 0.05–2 m/s, ±(0.1 + 2% of reading) above 2 m/s, Resolution 0.01 m/s, RS485 Output |
| Display | 3.5-inch Color Touch LCD |
| Power | Internal 5000 mAh Li-ion Battery (≥96 h standby), DC5V/1A Micro USB Input |
| Data Storage | Removable SD Card, CSV Export |
| Communication | RS485, USB, Wi-Fi, Bluetooth (up to 20 BLE sensors), M12 6-pin Aviation Connectors (3 digital channels), K-type Thermocouple Inputs (2), Analog Inputs (2, 0–2 V, 0.01 mV resolution, ±0.5% accuracy) |
| Enclosure | ABS + TPU Overmold, IP30 Rating, 175 × 92 × 38 mm, 1/4″ Tripod Thread, Detachable Wrist Strap |
| Brand | Sunnuclear |
|---|---|
| Origin | USA |
| Model | 1030 |
| Detector Type | Diffusion-based silicon photodiode (6-channel) |
| Measurement Interval Options | 0.5, 1, 2, 4, 8, 12, 16, 20, 24 h |
| Delay Options | 0, 12, 24, 48 h |
| Duration Options | 1–100 days or long-term mode (up to 1650 measurement intervals |
| Sensitivity | 15 cph per pCi/L |
| Accuracy | ±20% relative to NIST SRM 4973 |
| Operating Temperature | 7–35 °C (45–95 °F) |
| Relative Humidity Range | 0–95% RH |
| Pressure Range | 69–103 kPa (20.4–30.5 inHg) |
| Radon Measurement Range | 0.1–9999 pCi/L (3.7–369,996 Bq/m³) |
| Display | 16-character LCD with 6-button interface |
| Power | 4× C-cell alkaline batteries (≥350 h runtime) or 5 V DC USB adapter (110–230 V AC, 50/60 Hz) |
| Dimensions (W×L×H) | 5.5×9.6×4.4 in |
| Weight | 3.75 lb |
| Environmental Sensors | Integrated temperature (±1 °C), humidity (±5% RH, 1% resolution), pressure (±3.4 kPa, 0.14 kPa resolution) |
| Certifications | NRSB, NRPP, and C-NRPP accredited |
| Data Interface | USB 2.0 (cable included) |
| Storage Slots | 2 independent test slots |
| Tamper Detection | Built-in sensor |
| Mounting | Standard tripod thread (¼"-20) |
| Brand | Medcom |
|---|---|
| Origin | USA |
| Model | CRM-100 |
| Detector Type | Halogen-quenched Geiger-Müller tube with mica end-window (45 mm diameter, 1.5–2.0 mg/cm² density) |
| Radiation Types Detected | Alpha, Beta, Gamma, and X-ray |
| Energy Range | 20 keV – 3 MeV |
| Dose Rate Range | 0.001–110.0 mR/h or 0.01–1100 µSv/h |
| Count Rate Range | 0–3,500 CPS / 0–350,000 CPM |
| Total Count Capacity | Up to 9,999,000 counts |
| Timer Range | Up to 40 hours |
| Sensitivity | ≥1,000 CPM per mR/h (referenced to Cs-137) |
| Accuracy | ±10% typical, ±15% maximum (mR/h and µSv/h modes) |
| Audio Feedback | Click-per-count (user-muteable) |
| Display | 4-digit LCD with mode indicators |
| Output Interface | 3.5 mm mono jack (CMOS-compatible TTL pulse output) |
| Input Interface | 2.5 mm calibration input port |
| Power | One 9 V alkaline battery (typical life: 2,160 hours) |
| Dimensions | 150 × 80 × 30 mm |
| Weight | 225 g (including battery) |
| Certifications | CE, RoHS, WEEE, ISO 9001:2001 & ISO 14001 |
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | JC-RAD-14 |
| Sampling Method | Active Pump-aspiration |
| Measurement Range | Air Radon: 3–150,000 Bq/m³ |
| Soil Radon | 300–400,000 Bq/m³ |
| Radon Exhalation Rate | 0.001–10.000 Bq/(m²·s) |
| Water Radon | 0.003–100 Bq/L |
| Detection Repeatability | ≤5% (at 1800 Bq/m³, 65% RH, 25°C) |
| 8-h Drift | ≤10% |
| Power | Rechargeable Li-ion battery (≥30 h continuous operation) or AC adapter |
| Operating Temperature | −10°C to +40°C |
| Relative Humidity | ≤98% RH |
| Display | Backlit dot-matrix LCD |
| Data Storage | >200,000 records |
| Flow Rate | Up to 3 L/min (peak) |
| Communication Interfaces | USB, RS232, RS485, TCP/IP, Industrial Wireless |
| Inlet/Outlet Fittings | Anodized Aluminum |
| Self-background Count Rate | ≤0.3 cpm |