BrandMesaLabs
OriginUSA
ModelDefender 520
Flow PrinciplePositive Displacement (Dry Piston)
Flow RangeL: 5–500 mL/min
M50–5,000 mL/min
H300–30,000 mL/min
Volume Accuracy±1.0% of reading
Temperature Measurement±0.8 °C (typ.), ±1.3 °C (max)
Pressure Measurement±3.5 mmHg (typ.), ±7.0 mmHg (max)
UnitsmL/min, L/min, cc/min, cf/min
InterfaceRS-232
ComplianceISO/IEC 17025 accredited calibration, NIST-traceable, NVLAP Lab Code 200661-0
SoftwareDryCal Pro v5.x (real-time data logging, audit trail, CSV export)
Application ScopeIndustrial hygiene, occupational health, ambient air monitoring, personal sampling pump calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSKC
OriginUSA
ModelChek-mate 375 Series
Flow Ranges5.0–30.0 L/min (High), 0.50–5.0 L/min (Medium), 20–500 mL/min (Low)
Accuracy±1% of reading within specified ranges, ±2.5% outside
Operating Temperature0–40 °C
Pressure Range700–1090 mbar
Altitude Limitup to 3050 m
Power9 V alkaline battery (≈30 h operation, auto-shutdown after 15 min idle)
Weight~232–236 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMesaLabs
OriginUSA
ModelFlexCal
Flow Range5 mL/min to 50 L/min
Accuracy±0.5% of reading
Temperature SensorIntegrated
Pressure SensorIntegrated
Flow UnitssL/min, smL/min, scf/min, scc/m, mL/min, L/min, cc/min, cf/min
Temp Units°C, °F
Pressure UnitsmmHg, PSI, kPa
Measurement Interval1–15 sec
Gas CompatibilityNon-corrosive, non-condensing gases (<70% RH)
Flow ModeCompressed air or vacuum
Readout ModesSingle-cycle, continuous, or pulse-averaged (1–100 readings)
Power6 V rechargeable sealed lead-acid battery (3 h w/ backlight, 8 h w/o)
Environmental Operating Range0–70 °C, non-condensing
Max Absolute Pressure15 PSI
DisplayBacklit LCD graphic display
Data InterfaceUSB port with 1 m cable
EnclosurePelican™ protective case
ComplianceISO/IEC 17025 traceable calibration
Warranty1 year (instrument), 6 months (battery)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMesaLabs
OriginUSA
ModelDefender 510
Flow RangeL: 5–500 mL/min, M: 50–5,000 mL/min, H: 300–30,000 mL/min
Volume Flow Accuracy±1% of reading
Volume UnitsmL/min, L/min, cc/min, cf/min
CalibrationNIST-traceable, ISO/IEC 17025 accredited (NVLAP Lab Code 200661-0)
InterfaceRS-232
SoftwareDryCal Pro
ComplianceOSHA Technical Manual referenced method for personal sampling pump calibration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMesaLabs
OriginUSA
ModelDefender 530+
Flow PrincipleDry Piston Volumetric Displacement
Calibration TraceabilityNIST-traceable, ISO/IEC 17025 accredited (NVLAP Lab Code 200661-0)
Flow RangesL: 5–500 mL/min
M50–5,000 mL/min
H300–30,000 mL/min
Volumetric Accuracy±0.75% of reading
Standardized Flow Accuracy±1.0% of reading
Temperature Accuracy±0.8 °C (typical), ±1.3 °C (max)
Pressure Accuracy±3.5 mmHg (typical), ±7.0 mmHg (max)
UnitsmL/min, L/min, cc/min, cf/min (volumetric)
InterfaceRS-232
ComplianceOSHA Technical Manual reference, GLP/GMP-ready audit trail support via DryCal Pro software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model4146
Flow Range0.01–20 L/min
Accuracy±2% of reading or ±0.05 STD L/min (whichever is greater)
Response Time4 ms
Dimensions127 mm × 50 mm × 32 mm
Weight0.8 kg
Power Supply7.5 VDC ±1.5 V, peak current 300 mA
Warm-up Time1 min
Temperature CompensationYes
Pressure CorrectionYes
NIST-Traceable Calibration CertificateIncluded
NIOSH-Approved Primary Reference StandardYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTSI
OriginUSA
Model4046
Flow Range2.5–300 L/min
Accuracy±2% of reading or ±0.05 STD L/min (whichever is greater)
DisplayReal-time volumetric flow (temperature- and pressure-compensated)
Response Time4 ms
Dimensions183 × 64 × 53 mm
Weight0.5 kg
Power7.5 VDC ±1.5 V, peak current 300 mA
Warm-up Time1 min
CalibrationNIST-traceable certificate included
ComplianceNIOSH-approved primary calibration reference instrument