- All
- Favorite
- Popular
- Most rated
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BG-400A1 |
| Internal Dimensions (W×D×H) | 450 × 450 × 500 mm |
| Temperature Range | 10–300 °C |
| Temperature Uniformity | ±1 °C |
| Humidity Range | Not Applicable (Dry Heat / UV Only) |
| UV Wavelength | 340 nm (UVA-340 lamp standard) |
| Black Panel Temperature Range | 40–80 °C (adjustable per test protocol) |
| Irradiance Control | 0.63–1.25 W/m² @ 340 nm |
| Chamber Volume | 100 L |
| Heating Power | 2000 W |
| Power Supply | 220 V AC, 50/60 Hz |
| Compliance | GB/T 2951.12–2008, ASTM G154, ISO 4892-3, IEC 60068-2-5 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8205 |
| Power Supply | AC 220 V |
| Power Consumption | 250 W |
| Load on Specimen | 26.7 ± 0.2 N |
| Rubber Wheel Rotational Speed | 76 ± 2 rpm |
| Abrasive Wheel Rotational Speed | 34 ± 1 rpm |
| Adjustable Inclination Angle Between Wheels | 15° or 25° |
| Dimensions (L×W×H) | 600 × 480 × 400 mm |
| Net Weight | 60 kg |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Domestic |
| Model | HMQG-100 |
| Instrument Type | Metallographic Cutting System |
| Cutting Display Resolution | 0.01 mm |
| Dimensional Accuracy | ±1 mm |
| Internal Worktable Dimensions | 600 × 600 mm |
| X-Axis Travel Range | 1000 mm |
| Minimum Specimen Size | 25 × 25 × 5 mm |
| Maximum Specimen Thickness | 400 mm |
| Power Supply | 220 V AC |
| Rated Power | 2.2 kW |
| Brand | All Precision Instrument |
|---|---|
| Model | BU-800A |
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Producer |
| Power Supply | 220 V ±5%, 50 Hz, 2 kW |
| UV Lamp Configuration | 16 × 20 W low-pressure mercury lamps (253.7 nm peak output) |
| Conveyor Speed | 0–5 m/min (infinitely variable, digital display) |
| Tunnel Dimensions | 2000 mm (L) × 500 mm (W) × 200–300 mm (H, adjustable inlet/outlet height) |
| UV Exposure Zone | 1000 mm |
| Construction Material | 304 stainless steel (outer shell: 1.2 mm |
| inner reflective chamber | 1.0 mm mirror-finish #2B) |
| Conveyor Belt | Black PTFE-coated mesh belt |
| Safety Features | Light-shielded entry/exit zones with adjustable baffles, overvoltage/overcurrent protection, real-time lamp hour counter, fault alarm indication |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BWD-D |
| Temperature Control Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 °C to –30 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber specimens or 15 plastic specimens per test cycle) |
| Timer Range | 0–99 min, 1-s resolution |
| Cooling Medium | Ethanol or other non-freezing liquid |
| Stirring Motor Power | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient Limit | ≤25 °C |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap (head to specimen holder) | 6.4 ± 0.3 mm |
| Horizontal Offset (impact centerline to holder centerline) | 8 ± 0.3 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS |
| Price Range | USD 1,400 – 2,800 |
| Power Supply | 100–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 9000 mbar (145 psi) |
| Min Inlet Pressure | 4000 mbar (58 psi) |
| Dimensions | 400 × 380 × 335 mm (W × D × H) |
| Test Pressure Range | 100–8000 mbar (1.5–116 psi) |
| Accuracy | Net Volume Test ±4% |
| Environmental Conditions | 15–35 °C |
| Test Duration | Net Volume Test 5±2 min |
| Water Intrusion Test | Set Time + 5±2 min |
| Display | 5.7″ backlit monochrome LCD |
| Data Interface | RS232 serial port |
| Language Options | English / Chinese |
| Storage Capacity | 500 test records (incl. curves) |
| Print Output | Dot-matrix printer (Chinese/English), full parameter + result + curve |
| Sample Compatibility | Disc membranes Φ25–Φ300 mm |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Detection |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.5 mg/L |
| Accuracy | ±5% |
| Resolution | 1 µg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Power Consumption | 95 W |
| Dimensions | 340 × 390 × 145 mm |
| Weight | 15 kg |
| Response Time | ≤6 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature | 10–40 °C |
| Relative Humidity | ≤85% RH |
| Linearity Error | ±5% |
| Control Interface | Color Touchscreen with Embedded System |
| Connectivity | Bluetooth Wireless Control |
| Compliance | Chinese Pharmacopoeia 2015 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Capillary Rheometer |
| Model | BML-400-B |
| Maximum Load Capacity | 25 kN |
| Temperature Range | 50–450 °C |
| Temperature Accuracy | ±0.1 °C (chamber), ±0.2 °C (barrel) |
| Barrel Diameter Options | 9.5, 12, 15 mm (custom lengths available) |
| Piston Speed Range | 0.0005–20 mm/s |
| Dynamic Speed Ratio | 1:40,000 |
| Pressure Sensor Range | Up to 2000 bar |
| Pressure Accuracy | < ±0.25% FS |
| Capillary Dies | Five standard options (e.g., 5/0.5-L=5 mm/D=0.5 mm |
| Die Material | Tungsten carbide |
| Barrel & Piston Material | Nitrided stainless steel |
| Control Mode | Constant piston speed or constant pressure |
| Compliance | ASTM D3835, ISO 11443, GB/T 3680 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Test Pressure | 6900 mbar (sensor customizable) |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 10–80% RH |
| Dimensions (W×D×H) | 240 × 320 × 260 mm |
| Display | 5.7–7-inch color touchscreen, 256-color, GUI in English/Chinese |
| Data Storage | 32 GB internal, ≥1 million test records |
| Print Output | Thermal printer, bilingual (English/Chinese), includes test parameters, results, and pressure decay curves |
| Test Duration | Bubble Point: 2 ± 2 min |
| Diffusion Flow | 7 ± 2 min |
| Water Intrusion | 7 ± 2 min |
| System Leak Check | 3 ± 1 min |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BSQ-20 |
| Power Supply | AC 220 V |
| Sample Vial Capacity | 12 mL |
| Vial Tray Configuration | 14 × 14 (196 positions) |
| Positioning Accuracy | ±0.01 mm |
| Controller Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| Frame Material | Anodized Aluminum Alloy |
| Motion Control | Digital Stepper Motor with Microstepping Driver |
| Automation Level | Fully Unattended Operation |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BWN-5-10KN |
| Max Load Capacity | 10 kN |
| Accuracy Class | 0.5 |
| Force Measurement Range | 0.4–100% of full scale |
| Force Resolution | 1/200,000 of full scale (fixed, no range switching) |
| Effective Test Width | 400 mm (customizable) |
| Effective Tensile Travel | 800 mm (customizable) |
| Test Speed Range | 50–300 mm/min |
| Displacement & Strain Measurement Accuracy | ±0.5% of reading |
| Drive System | Servo Motor + Precision Ball Screw |
| Power Supply | 220 V / 380 V, 50 Hz |
| Power Consumption | 0.75 kW (typical) |
| Net Weight | ~300 kg |
| Compliance | GB/T 16491–2008, ASTM E4, ISO 7500-1, EN 10002-2 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Membrane Conductivity Differential Method |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | <4 minutes per sample |
| Display | 640×480 color touchscreen |
| Data Storage | 6-month history (≥10,000 records) |
| Interface | RS232 |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Brand | All Precision Instrument |
|---|---|
| Model | BEST-121 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Voltage Range | DC 10 V, 50 V, 100 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Operating Temperature | 0–40 °C |
| Relative Humidity | ≤70% RH |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | 8 hours |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 285 mm × 245 mm × 120 mm |
| Weight | ~6 kg (main unit) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | B121 |
| Price | USD 1,200 (FOB Beijing) |
| Compliance | GB/T 1410–2006 / IEC 60093:1980 |
| Measurement Principle | Guarded Three-Electrode Ring Method |
| Resistance Range | 1.0×10³ – 2.0×10¹² Ω |
| Resistivity Range | 1.0×10³ – 2.0×10¹² Ω·m |
| Sheet Resistance Range | 1.0×10⁴ – 2.0×10¹² Ω/□ |
| Resolution | 0.1×10³ – 0.1×10¹² Ω (auto-ranging) |
| Power Supply | 220 V ±10%, 50 Hz ±4%, ≤20 W |
| Dimensions (W×H×L) | 280 × 90 × 275 mm |
| Net Weight | ≤3.0 kg |
| Standard Electrode | Triple-ring coaxial electrode (center cylinder Ø50 mm × 40 mm h |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | BQS-19 Series |
| Power Supply | 170–240 V AC, 50/60 Hz, 100 W |
| Max Operating Pressure | 7999 mbar |
| Minimum Inlet Pressure | 3000 mbar |
| Test Pressure Range | 500–6900 mbar |
| Pressure Sensitivity | ±1.0 mbar |
| Bubble Point Accuracy | ±60 mbar |
| Test Duration (Bubble Point) | 2 ± 2 min |
| Test Duration (Diffusion Flow / Water Intrusion) | 7 ± 2 min |
| System Leak Test Time | 3 ± 1 min |
| Display | 5.7-inch 32-bit touchscreen |
| Data Storage | 32 GB (≥1 million records) |
| Interface | RS232/USB/Ethernet for PC connectivity |
| Compliance Support | FDA 21 CFR Part 11 (audit trail enabled), GMP/GLP-ready |
| Language Options | English & Chinese |
| Dimensions | 500 × 200 × 180 mm (L×W×H) |
| Environmental Operating Range | 0–50 °C, 10–80% RH |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | UV/Persulfate Oxidation + NDIR (Non-Dispersive Infrared) Detection |
| Measurement Range | 0.001–1.0 mg/L (customizable up to 1000 mg/L via sensor configuration) |
| Accuracy | ±4% |
| Resolution | 0.001 mg/L |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Response Time | <4 minutes |
| Sample Temperature Range | 1–95 °C |
| Display | 640×480 color TFT touchscreen |
| Data Storage | 6-month history retention |
| Compliance | Chinese Pharmacopoeia 2010 Edition, Appendix VIII R |
| Interface | RS232 |
| Power Supply | 220 V AC |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory TOC Analyzer |
| Model | BC-40A |
| Detection Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Oxidation Method | UV/Persulfate Oxidation |
| Measurement Range | 0.001–1.000 mg/L |
| Accuracy | ±5% |
| Detection Limit | 0.001 mg/L |
| Repeatability | ≤3% |
| Analysis Time | 4 min |
| Response Time | ≤15 min |
| Sample Temperature Range | 1–95 °C |
| Ambient Temperature Range | 10–40 °C (max. ±5 °C/day drift) |
| Internal Flow Rate | 0.5 mL/min |
| Relative Humidity | ≤85% |
| Zero Drift | ±5% FS/24 h |
| Span Drift | ±5% FS/24 h |
| UV Lamp | Dual-wavelength (185 nm & 254 nm) |
| Pump Tubing | Imported high-stability peristaltic tubing |
| Key | Brand: All Precision Instrument |
|---|---|
| Model | BWD-C |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | GB 1682, GB 5470–2008, HG 2-162–1965 |
| Temperature Range | Ambient to –70 °C (ambient ≤25 °C) |
| Temperature Stability | ±0.3 °C |
| Cooling Rate | ~2.5 °C/min (0 to –30 °C), ~2.5 °C/min (–30 to –40 °C), ~2.0 °C/min (–40 to –70 °C) |
| Internal Chamber Dimensions | 280 × 170 × 120 mm (L×W×H) |
| External Dimensions | 900 × 500 × 800 mm (L×W×H) |
| Sample Capacity | 1 test fixture (4 rubber or 15 plastic specimens per cycle) |
| Timer Range | 0–99 min, 1 s resolution |
| Impact Head Radius | 1.6 ± 0.1 mm |
| Impact Gap | 6.4 ± 0.3 mm |
| Centerline Offset | 8 ± 0.3 mm |
| Cooling Medium | Industrial ethanol or non-freezing liquid |
| Circulation Motor | 8 W |
| Power Supply | 220–240 V AC, 50 Hz, 1.5 kW |
| Operating Ambient | ≤25 °C |
| Cooling System | Compressor-based with proportional heating compensation |
| Stirring | Continuous circulation for thermal uniformity |
| Safety | Integrated over-temperature and low-coolant-level alarm |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | C-50KV |
| Max Output Voltage | 50 kV AC/DC (RMS) |
| Input Voltage | AC 220 V |
| Power Rating | 3 kVA |
| Voltage Ramp Rate | 0.1–5.0 kV/s (adjustable) |
| Compliance | GB/T 1981.2–2003, GB/T 7113.2–2005, GB/T 10580–2003, ISO 293, ISO 294-1, ISO 294-3, ISO 295, ISO 10724, IEC 60296, IEC 60455-2, IEC 60674-2 |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Electronic Tensile Testing Machine |
| Maximum Test Load | 6 kN |
| Force Measurement Range | 2–100% of Full Scale |
| Force Accuracy | ±1% FS |
| Test Stroke | 600 mm |
| Displacement Resolution | 0.01 mm |
| Speed Range | 0.05–500 mm/min |
| Speed Accuracy | ±1% |
| Compliance Standards | GB/T 16491, GB/T 1040, ASTM D412, ASTM D3759, ISO 37, ISO 34-1, EN ISO 1798, DIN 53507-A |
| Power Supply | AC 220 V ±10%, 50 Hz, 0.5 kW |
| Dimensions (W×D×H) | 400 × 400 × 1300 mm |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BG-8005 |
| Pricing | Upon Request |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler |
| Model | BKQ-20 |
| Sample Vial Capacity | 12 mL |
| Maximum Vial Count | 196 (14 × 14 array) |
| Positioning Accuracy | ±0.01 mm |
| Power Input | AC 220 V |
| Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| GC Synchronization | Triggered via TTL/relay signal |
| Vacuum Reconditioning | Integrated for vial reuse |
| Communication Interfaces | RS-232, USB, optional Ethernet |
| Sample Injection Modes | Headspace, direct gas loop, split/splitless compatible |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable TOC Analyzer |
| Detection Principle | Direct Conductivity Detection after UV/Persulfate Oxidation |
| Oxidation Method | High-Temperature Catalytic Combustion (supplemented by UV/persulfate for low-level precision) |
| Measurement Range | 0.01–1000 µg/L (0.01–1.000 mg/L) |
| Accuracy | ±4% of reading within calibrated range |
| Resolution | 0.001 mg/L (1 µg/L) |
| Detection Limit | 0.001 mg/L (1 µg/L) |
| Repeatability | ≤3% RSD |
| Sample Temperature Range | 1–95 °C |
| Analysis Time | ≤6 minutes per sample |
| Data Storage | Internal memory supporting ≥6 months of timestamped records |
| Compliance | USP <643>, EP 2.2.44, ChP 2020 Edition (General Chapter 0682), FDA CGMP Annex 1 (Water Systems), ISO 8573-1 (for pharmaceutical compressed air-associated water), GLP/GMP-ready audit trail capability |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS-19+ |
| Power Supply | 100–240 V AC, 50/60 Hz, ≤100 W |
| Max Operating Pressure | 9999 mbar |
| Min Inlet Pressure | 4000 mbar |
| Pressure Range for Testing | 100–8000 mbar (1.5–116 psi) |
| Bubble Point Accuracy | ±50 mbar |
| Diffusion Flow Accuracy | ±4% |
| Net Volume Test Accuracy | ±4% |
| Test Duration (Bubble Point) | 15 ± 2 min |
| Test Duration (Enhanced Bubble Point) | 20 ± 2 min |
| Test Duration (Diffusion Flow) | 10 ± 2 min |
| Display | 5.7" monochrome TFT LCD |
| Interface | RS232 serial port |
| Data Storage | 500 test records (configurable extension via PC connection) |
| Environmental Operating Conditions | 5–35 °C, 10–80% RH |
| Dimensions (W × D × H1 × H2) | 400 × 380 × 100 × 235 mm |