- All
- Favorite
- Popular
- Most rated
| Brand | ATS |
|---|---|
| Origin | Jiangsu, China |
| Model | AH-D400 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 440 × 800 × 410 mm |
| Processing Capacity | 30–40 L/h |
| Minimum Sample Volume | 60 mL |
| Maximum Design Pressure | 2000 bar |
| Maximum Operating Pressure | 1500 bar |
| Flow Control | Variable-Frequency Drive (VFD) |
| Pressure Sensor | Digital display, 0–2000 bar range, ±10 bar accuracy |
| Cooling System | Integrated heat exchanger |
| Safety Features | Programmable overpressure shutdown, automatic exhaust valve for zero sample residue |
| Power Supply | 380 V AC, 5.5 kW |
| Certification | CE compliant |
| Footprint | Floor-standing with casters |
| Brand | ATS |
|---|---|
| Origin | Canada |
| Model | AH-D150 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 440 × 800 × 410 mm |
| Processing Capacity | 5–15 L/h |
| Minimum Sample Volume | 15 mL |
| Maximum Design Pressure | 2000 bar |
| Maximum Operating Pressure | 1500 bar |
| Flow Control | Variable-Frequency Drive (VFD) with Adjustable Flow Rate |
| Pressure Sensing | Digital Pressure Transducer, 0–2000 bar Range, ±10 bar Accuracy |
| Integrated Cooling System | Yes |
| Overpressure Protection | Programmable Safety Cut-off |
| Residual Volume | Near-Zero via Integrated Exhaust Valve |
| Power Supply | 220 V AC, 1.5 kW |
| Certification | CE Compliant (EU Machinery Directive 2006/42/EC & EMC Directive 2014/30/EU) |
| Brand | Alphavita |
|---|---|
| Origin | Liaoning, China |
| Model | MVS-60 |
| Sterilization Chamber Dimensions | Φ370 × 610 mm |
| External Dimensions | 550 × 550 × 820 mm |
| Chamber Volume | 55 L |
| Vessel Material | S30408 stainless steel (GB/T 24511–2017), 3 mm wall thickness |
| Design Standard | GB 150–2011 |
| Altitude Rating | Certified for operation up to 4000 m ASL |
| Safety Features | Dual dry-run protection, overcurrent protection, earth-leakage detection, four-point interlocked door system, spring-loaded safety valve, real-time overpressure alarm |
| Exhaust System | Pressure-stabilized air removal (98% air displacement), six-stage adjustable exhaust rate & temperature |
| Cooling | High-capacity external cooling fan (optional internal fan), variable-speed cooling control |
| Control Modes | Four pre-programmed cycles + user-defined program memory + pre-heating cycle + time-scheduled start |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Vetgenies 8 |
| Instrument Type | Veterinary Real-Time qPCR Platform |
| Nucleic Acid Extraction | Optional On-Device Lysis (Extraction-Free Workflow Supported) |
| Detection Chemistry | Dual-Channel SYBR Green I and Probe-Based (FAM/HEX) Fluorescence Detection |
| Thermal Cycling Accuracy | ±0.25 °C |
| Ramp Rate | Up to 5.0 °C/s |
| Reaction Volume | 10–50 µL |
| Throughput | 8 Samples per Run |
| Optical System | Integrated LED Excitation & Photodiode Detection |
| Data Output | Ct Values, Amplification Curves, Melting Curves, Qualitative/Quantitative Reports |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T 10 BASIC S025 |
| Pricing | Upon Request |
| Brand | Beckman Coulter |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China-manufactured) |
| Model | CytoFLEX o |
| Technology Platform | Nanoscale Flow Cytometry |
| Instrument Type | Flow Cytometer |
| Primary Use Case | Research |
| Lasers | 405 nm, 488 nm, 561 nm, 638 nm |
| Fluorescence Detection Channels | 6 |
| Side Scatter (SSC) Detection Channels | 5 |
| Particle Size Detection Range | 40 nm – 1 µm |
| Automated Sample Loading | Yes |
| Compensation Method | Fully Automated |
| Sorting Capability | Optional |
| Sorting Output Ports | 6-way |
| Voltage Adjustment Required | No |
| Brand | BTX |
|---|---|
| Origin | USA |
| Model | ECM 830 |
| High Voltage Range | 505–3000 V |
| Low Voltage Range | 5–500 V |
| Pulse Duration | 10 ms–10 s |
| Capacitance | 111 µF |
| Resistance | 25 Ω |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Model | Vetus 9 |
| Imaging Platform | ZST+ Zone Scanning Technology |
| Core Modalities | B-mode, Color/Power Doppler, Pulsed-wave & Continuous-wave Spectral Doppler, Contrast-enhanced Ultrasound (UWN+), Shear Wave Elastography, Tissue Doppler Imaging (TDI), Tissue Tracking Quantification |
| Regulatory Status | CE Marked, FDA 510(k) cleared for veterinary use |
| Intended Use | Diagnostic imaging and functional assessment in companion animals, equine, and large animal clinical practice |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C1 Package 1/10 |
| Compliance | DIN 51900, ISO 1928 |
| Cooling Requirement | RC 2 basic recirculating chiller (included) |
| Software Compatibility | C6040 Calwin (optional) |
| Sample Capacity | Up to 500 initial tests with included consumables |
| Includes | C1.10 combustion vessel, C5010.5 large crucible holder, C6 large quartz crucible, calibration records (n=25), ignition wires, combustion aids, and accessory kit |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | MPR-210 |
| Temperature Range | 2°C to 8°C (ambient: 5–30°C) |
| Effective Volume | 291 L |
| Internal Dimensions | 570 × 498 × 1070 mm |
| External Dimensions | 660 × 650 × 1635 mm |
| Cooling Method | Forced-air convection cooling |
| Compressor Type | Hermetic |
| Refrigerant | R134a (environmentally compliant) |
| Power Consumption | 262 W |
| Net Weight | 107 kg |
| Door Type | Electrically heated double-glazed door with low-emissivity thermal-reflective film |
| Safety Features | High/low temperature alarm, door-open alarm (>60 s), sensor fault detection, condenser blockage & overheating monitoring |
| Interior Material | Powder-coated steel |
| Exterior Material | Powder-coated steel |
| Standard Accessories | 1 LED interior light, 1 set of keys, 4 adjustable wire shelves |
| Port | One Φ32 mm temperature probe access port (left side) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XT 150 |
| Pricing | Upon Request |
| Brand | Rainin |
|---|---|
| Origin | Switzerland |
| Model | SE4-10XLS+ |
| Volume Range | 0.5–10 µL |
| Type | Single-Channel Electronic Pipette |
| Drive Mechanism | Stepper Motor (4,000-step resolution) |
| Display | Full-color graphical LCD |
| Control Interface | Joystick + rotary navigation dial |
| Calibration | Auto-zeroing at end of each pipetting cycle |
| GLP/GMP Compliance | Password-protected settings, tamper-proof service logs, audit trail-capable |
| Power | Rechargeable lithium-ion battery (≥1 day runtime, >1,000 charge cycles) |
| Ergonomics | Ambidextrous design, LTS (Low-Torque Seal) tip ejection system (ejection force ≤0.6 kg), integrated finger hooks, glove-compatible operation |
| Software Integration | Preloaded PureSpeed™ mode for biomolecule purification (proteins, oligonucleotides) |
| Onboard Memory | Multiple user-defined protocols stored locally |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AKTA avant |
| Flow Rate Options | 25 mL/min (AKTA avant 25) or 150 mL/min (AKTA avant 150) |
| Pressure Rating | Up to 20 MPa (200 bar) |
| Software | UNICORN 7.x or later |
| Column Tracking | RFID-enabled column recognition |
| Fraction Collector | Integrated Peltier-cooled (4–15 °C) |
| Buffer Preparation | BufferPro™ automated in-line mixing |
| Compliance | Supports 21 CFR Part 11-compliant configurations with audit trail, electronic signatures, and user access control |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ECM 399 |
| Price Range | USD $13,500 – $40,500 (FOB) |
| Product Type | Electroporation System for Cell Transfection and Transformation |
Show next