- All
- Favorite
- Popular
- Most rated
| Brand | Leica |
|---|---|
| Country of Origin | Germany |
| Microscope Type | Upright |
| Eyepiece Configuration | Binocular |
| Objective Turret | Motorized 6-Position |
| Condenser | Automated High-Aperture (0.90 NA) with Position Memory |
| Illumination | Motorized Brightness Control per Objective |
| Ergonomic Features | Adjustable-Height Focus Knobs (Patent DE10340721), Symmetrical XY Stage, One-Hand Operation, ErgoStage with Ceramic Surface |
| Software Compatibility | Leica Application Suite (LAS) for Pathology & Cytology Imaging |
| Compliance | Designed for ISO 13485-aligned clinical laboratories, supports GLP/GMP documentation workflows via LAS audit trail and user access control |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-35Vet |
| Instrument Type | Veterinary Anesthesia and Monitoring System |
| Display | 10.4-inch TFT high-resolution touchscreen |
| Ventilation Modes | Volume-Controlled (VCV), Pressure-Controlled (PCV), Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG), Spontaneous Breathing Support |
| Minimum Tidal Volume | 5 mL |
| Gas Monitoring Options | EtCO₂, Oxygen (O₂), Nitrous Oxide (N₂O), Halogenated Anesthetics (e.g., Isoflurane, Sevoflurane) |
| Vaporizer | Precision V60 calibrated halogenated anesthetic vaporizer (CE & FDA cleared) |
| Breathing Circuit | Integrated dual-mode (rebreathing/non-rebreathing), tool-free soda lime canister replacement |
| Leak Test | Automated self-test with graphical troubleshooting guidance |
| Waste Gas Scavenging | Optional passive or active scavenging system |
| Compliance | Designed to meet IEC 60601-1, IEC 60601-2-13, ISO 80601-2-13, and applicable veterinary medical device regulatory requirements |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | UCD300 |
| Operating Frequency | 20 kHz |
| Ultrasonic Power Output | 155 W / 310 W (dual-step adjustable) |
| Sample Volume Range | 5 µL – 20 mL |
| Maximum Throughput | ≥24 samples per run |
| Processing Chamber Volume | 750 mL |
| Dimensions (Controller) | 150 × 300 × 195 mm (W×D×H) |
| Dimensions (Processing Chamber) | 350 × 260 × 150 mm (W×D×H) |
| Weight | 20 kg |
| Timer Range | 0–60 sec or 0–15 min (on/off cycles) |
| Compatible Vessels | PCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes |
| Fragmentation Range (DNA) | 2 kb – <500 bp |
| Rotation Speed | Programmable constant-speed rotation during sonication |
| Compliance | CE-marked |
| Brand | Panasonic |
|---|---|
| Model | MDF-U780V |
| Temperature Range | –50 °C to –86 °C (0.1 °C adjustable) |
| Effective Volume | 736 L |
| Interior Dimensions (W×D×H) | 890 × 600 × 1380 mm |
| Exterior Dimensions (W×D×H) | 1030 × 875 × 1990 mm |
| Power Supply | 220 V, 50 Hz |
| Rated Input Power | 1185 W |
| Compressor Type | Dual hermetic compressors (1100 W each) |
| Refrigerants | R404A / R508B (ozone-friendly) |
| Insulation | Polyurethane foam + Vacuum Insulation Panels (VIP) |
| External Casing | Powder-coated galvanized steel |
| Internal Chamber | Electrogalvanized steel with polyester resin coating |
| Door Configuration | 1 outer door + 2 inner doors |
| Safety Features | High/low temperature alarm, power failure alarm, remote alarm contact, sensor self-diagnosis, compressor protection circuit |
| Standard Accessories | 1 set of keys, 3 stainless-steel shelves, 1 defrost scraper |
| Cooling Method | Direct cooling |
| Temperature Control | Microprocessor-based digital controller with LED display |
| Monitoring Ports | 2 × 17 mm access ports (rear, lower-left) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Loopster |
| Speed Range | 5–80 rpm |
| Adjustable Rotation Angle | 0°–90° |
| Timer Range | 1 s–5999 min |
| Platform Capacity | 2 kg (including fixtures) |
| Operating Temperature | 4–50 °C |
| Protection Class | IP21 |
| Dimensions (W×D×H) | 300 × 360 × 300 mm |
| Weight | 3 kg |
| Power Supply | 100–240 V, 50/60 Hz |
| Display | 7-segment LED |
| Speed Resolution | 1 rpm per step |
| Duty Cycle | Continuous operation supported |
| Platform Stackable | No |
| USB/RS232/Analog Output | None |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | HS 501 Digital |
| Drive Type | Reciprocal & Circular Orbital |
| Orbit Diameter | 30 mm |
| Speed Range | 0–300 rpm |
| Speed Display | LED Digital |
| Load Capacity (incl. clamps) | 15 kg |
| Timer Range | 1–56 min |
| Timer Display | Analog Scale |
| Operating Mode | Timed or Continuous |
| Input Power | 74 W |
| Motor Input Power | 70 W |
| Motor Output Power | 19 W |
| Duty Cycle | 100 % continuous operation |
| Ambient Temperature Range | 5–50 °C |
| Relative Humidity Limit | ≤80 % |
| Protection Class | IP21 (DIN EN 60529) |
| Voltage | 230 / 115 / 100 V |
| Frequency | 50/60 Hz |
| Dimensions (W × H × D) | 505 × 120 × 585 mm |
| Weight | 26 kg |
| Clamp Assembly | Not included — ordered separately |
| Brand | Beckman Coulter |
|---|---|
| Origin | USA |
| Instrument Type | Analytical Flow Cytometer |
| Configuration Options | Up to 3 Lasers / 13 Colors (CytoFLEX) |
| Fluorescence Sensitivity | FITC < 30 MESF, PE < 10 MESF |
| Small Particle Detection Limit | ≥80 nm (via VSSC) |
| Optical Architecture | Wavelength-Division Multiplexing (WDM) Detection |
| Regulatory Compliance | FDA 21 CFR Part 11–Ready |
| Software Interface | Dual-language (English/Chinese), Graphical User Interface (GUI) |
| Sorting Capability | Optional Sort Module Available |
| Intended Use | Research-Only |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | VXR Basic Vibrax |
| Oscillation Mode | Orbital |
| Orbit Diameter | 4 mm |
| Speed Range | 0–2200 rpm |
| Load Capacity (incl. clamp) | 2 kg |
| Motor Input/Output Power | 35 / 13.2 W |
| Operating Mode | Continuous |
| Display Type | Analog Scale |
| Dimensions (W × D × H) | 157 × 247 × 130 mm |
| Weight | 6.1 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Ingress Protection Rating | IP21 |
| Compliance | DIN EN 60529 |
| Brand | Molecular Devices |
|---|---|
| Origin | Shanghai, China |
| Model | QPix FLEX |
| Detection Method | Fluorescence Intensity |
| Functionality | Multimodal |
| Automation Level | Fully Automated |
| Assay Type | Automated Microbial Identification & Colony Isolation |
| Detector Type | Fluorescence Imaging Sensor |
| Sample Handling | Integrated Liquid Handling, Streaking, Plating, and Colony Picking |
| Dimensions | Compact Footprint (Designed for Benchtop & Anaerobic Chamber Integration) |
| Traceability | 2D Barcode Scanning for Microplate & Pick Log Registration |
| Compliance Context | Supports GLP/GMP-aligned workflows with full audit trail capability |
| Brand | Roche Diagnostics |
|---|---|
| Origin | Switzerland |
| Instrument Type | Digital PCR System |
| Model | Roche Digital LC |
| Regulatory Status | CE-IVD, FDA-cleared for in vitro diagnostic use (where applicable) |
| Compliance | ISO 13485, IVD Directive 98/79/EC, aligned with CLIA and CAP laboratory requirements |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WATO EX-65 Pro Vet |
| Instrument Type | Integrated Veterinary Anesthesia & Ventilation System |
| Regulatory Classification | Class II Medical Device (CN), CE-marked for Veterinary Use |
| Brand | Molecular Devices |
|---|---|
| Model | MultiWash-C |
| Type | Automated Microplate Washer |
| Plate Format | 96-well (flat-bottom, U-bottom, V-bottom) |
| Dispense Volume Range | 50–3000 µL (in 50 µL increments) |
| Accuracy & Precision @ 300 µL | ≤3% |
| Residual Volume | ≤1 µL/well |
| Wash Cycle Time (3 cycles, 3000 µL/well) | <90 s (12-channel head), <125 s (8-channel head) |
| Oscillation | 3 adjustable frequencies |
| Aspiration/Dispense Speed | 3-speed control |
| Onboard Storage | 100 programs, up to 99 steps per program |
| Dimensions (W×H×D) | 46 × 30 × 40 cm |
| Weight (packed) | 13 kg |
| Power Input | 100–240 V, 50–60 Hz |
| Integrated Sensors | Liquid level detection for 2 × 4 L wash bottles and 1 × 10 L waste bottle |
| Compliance | Designed for GLP-compliant ELISA workflows |
| Software | Standalone touchscreen interface, no external PC required |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | Biacore S200 |
| Sample Capacity | One 96-well or 384-well microplate |
| Injection Volume | 2–350 µL |
| Analysis Time per Cycle | 2–15 min |
| Temperature Control Range | 4°C to 45°C |
| Detection Limit | No theoretical lower molecular weight limit for analyte binding detection |
| Brand | Zhichu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-VCN |
| Instrument Type | CO₂-Controlled Temperature-Regulated Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Ø50 mm) |
| Oscillation Amplitude | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Number of Shaking Platforms | 3 |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| CO₂ Control Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % |
| Display | LCD Touchscreen |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| Noise Level | <55 dB(A) |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Z70 Vet |
| Instrument Type | Veterinary Diagnostic Ultrasound System |
| Display | 15-inch Full-View LCD Touchscreen |
| Application Focus | Canine, Feline, Equine, Bovine, and Ovine Imaging |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | AI800 |
| Imaging Sensor | 8.3 MP cooled CCD |
| Lens | F0.74 fixed-focus科研级镜头 |
| SNOW™ Mode | Real-time signal-to-noise optimization algorithm |
| Light Sources | 7-channel LED fluorescence excitation (365–740 nm) |
| Sample Compatibility | Gels, blots, multiwell plates, Petri dishes, membranes |
| Software | ImageQuant TL with remote access capability |
| Compliance | Designed for GLP/GMP-aligned workflows, audit-trail enabled via ImageQuant TL v10.3+ |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-CS9 |
| Instrument Type | CO₂-Controlled Temperature-Shaking Incubator |
| Stacking Configuration | 3-Layer Modular Stack |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Φ50 mm platform) |
| Oscillation Amplitude | Φ50 mm (standard), Φ26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Range | Ambient to 90 % RH |
| Humidity Accuracy | ±5 % RH |
| Humidity Resolution | 1 % RH |
| CO₂ Range | 0–20 % |
| CO₂ Accuracy | ±0.1 % (IR sensor) |
| CO₂ Decay Time | 30 min (5.0 % → 4.5 %) |
| Platform Dimensions (L×W) | 1000 × 530 mm per layer |
| Max Capacity (per layer, stainless steel clamps) | 250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 18 |
| Max Capacity (per layer, polymer clamps) | 250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 15 |
| Noise Level | <55 dB(A) |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
| External Dimensions (W×D×H) | 1430 × 845 × 1740 mm (3-layer) |
| Net Weight | ~728 kg |
| Brand | Mindray |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ePM 12M Vet |
| Instrument Type | Electrocardiography (ECG)-Enabled Multi-Parameter Veterinary Monitor |
| NIBP Algorithm | Species-Specific Cuff-Based Blood Pressure Algorithm |
| SpO₂ Technology | Motion-Tolerant and Low-Perfusion Resistant Pulse Oximetry |
| ECG Analysis | Multi-Lead Digital Signal Processing with CrozFusion™ Signal Fusion |
| Expandable Modules | CO₂ (Capnography), IBP (Invasive Blood Pressure, up to 4 channels), Cardiac Output (C.O.), Anesthetic Gas (AG), O₂/CO₂ (Artema® Technology) |
| Display | 12.1-inch Capacitive Touchscreen with Gesture Support |
| Data Storage | Internal Flash Memory + USB Export Capability |
| Compliance | IEC 60601-1, IEC 60601-2-51 (for Veterinary Monitors), ISO 13485 Certified Manufacturing |
| Brand | Diagenode |
|---|---|
| Origin | Belgium |
| Model | new pico |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power | 300 W |
| Operating Frequency | 40 kHz |
| Temperature Range | 4 °C to ambient |
| Maximum Sample Capacity | 16 tubes |
| Sample Volume Range | 20 µL – 2 mL |
| Cooling System | Integrated solenoid-valve-controlled recirculating chiller |
| Brand | Zhilchu |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ZCZY-CSR8 |
| Instrument Type | CO₂-Controlled Temperature-Shaking Incubator |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Φ50 mm platform) |
| Oscillation Amplitude | Φ50 mm (standard), Φ26 mm (optional) |
| Temperature Range | 4–60 °C (ambient: 23–25 °C) |
| Number of Shaking Decks | 3 |
| Temperature Uniformity | ±0.5 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| CO₂ Control Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Noise Level | <55 dB(A) |
| Max Load Capacity (stainless steel clamp) | 250 mL × 66 / 500 mL × 45 / 1000 mL × 28 / 2000 mL × 15 per deck |
| Deck Dimensions (L×W) | 928 mm × 530 mm |
| External Dimensions (L×W×H) | 1360 mm × 845 mm × 1740 mm (3-deck configuration) |
| Net Weight | ~596 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | Hula Dancer digital |
| Instrument Type | Orbital Shaker |
| Oscillation Mode | Circular |
| Orbit Diameter | 4.5 mm |
| Speed Range | 1200–2800 rpm |
| Speed Resolution | Fixed or Adjustable (No Digital Display) |
| Load Capacity (incl. Clamp) | 0.1 kg |
| Temperature Operating Range | 5–40 °C |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Class | IP42 (per DIN EN 60529) |
| Input Voltage | 100–240 V AC |
| Frequency | 50/60 Hz |
| Motor Input Power | 9.5 W |
| Motor Output Power | 5 W |
| Standby Power Consumption | 0.8 W |
| Continuous Operation Rated | 100 % |
| Dimensions (W × H × D) | 123 × 42 × 123 mm |
| Weight | 0.7 kg |
| Momentary Start Function | Yes |
| Timer | Not integrated |
| Speed Display | None |
| Brand | Zhilu |
|---|---|
| Model | ZCLY-180 |
| Instrument Type | CO₂-controlled incubator shaker |
| Timing Range | 0–999.9 h |
| Oscillation Frequency | 10–300 rpm (±1 rpm) |
| Amplitude | Ø26 mm |
| Temperature Range | 4–60 °C (at ambient 23–25 °C) |
| Temperature Uniformity | ±0.8 °C (at 37 °C) |
| Temperature Resolution | ±0.1 °C |
| CO₂ Range | 0–20% |
| CO₂ Control Accuracy | ±0.1% |
| Number of Shaking Platforms | 3 |
| Platform Size (L×W) | 485 × 485 mm |
| Max Capacity per Shelf | 250 mL × 25 / 500 mL × 16 / 1000 mL × 9 |
| Internal Chamber | R-cornered 304 stainless steel, seamless welded |
| Display | LCD touchscreen with real-time multi-parameter overlay |
| Data Logging | 1-min interval, up to 3 months’ storage |
| Connectivity | USB export |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Dimensions (W×D×H) | 760 × 680 × 1280 mm |
| Net Weight | ~183 kg |
| Noise Level | <55 dB(A) |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ÄKTA™ pure |
| Flow Rate Range | Up to 25 mL/min (ÄKTA™ pure 25) / Up to 150 mL/min (ÄKTA™ pure 150) |
| Pressure Limit | Up to 20 MPa |
| Conductivity Range | 0.01–999.9 mS/cm |
| UV Detection Wavelengths | 280 nm, 254 nm (dual-channel fixed-wavelength) |
| Fraction Collection | Programmable, time- or peak-triggered |
| Software Platform | UNICORN™ 7.x |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | ZhiChu |
|---|---|
| Origin | Guangdong, China |
| Model | ZCZY-VCS8 |
| Instrument Type | CO₂-Regulated Temperature-Controlled Orbital Shaker |
| Timer Range | 0–999.9 h |
| Oscillation Frequency | 10–250 rpm (Ø50 mm), 10–300 rpm (Ø26 mm) |
| Oscillation Amplitude | Ø50 mm (standard), Ø26 mm (optional) |
| Temperature Range | 4–60 °C (ambient 23–25 °C) |
| Number of Shaking Decks | 3 |
| Temperature Uniformity | ±0.3 °C at 37 °C |
| Temperature Accuracy | ±0.1 °C |
| CO₂ Control Range | 0–20 % |
| CO₂ Control Accuracy | ±0.1 % |
| CO₂ Decay Time | 30 min (from 5.0 % to 4.5 %) |
| Deck Dimensions (L×W) | 900 × 530 mm |
| Noise Level | <55 dB(A) |
| Power Supply | AC 220 V ±10 %, 50–60 Hz |
Show next