Empowering Scientific Discovery

Beijing Dequan Xingye Trading Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLeica
Country of OriginGermany
Microscope TypeUpright
Eyepiece ConfigurationBinocular
Objective TurretMotorized 6-Position
CondenserAutomated High-Aperture (0.90 NA) with Position Memory
IlluminationMotorized Brightness Control per Objective
Ergonomic FeaturesAdjustable-Height Focus Knobs (Patent DE10340721), Symmetrical XY Stage, One-Hand Operation, ErgoStage with Ceramic Surface
Software CompatibilityLeica Application Suite (LAS) for Pathology & Cytology Imaging
ComplianceDesigned for ISO 13485-aligned clinical laboratories, supports GLP/GMP documentation workflows via LAS audit trail and user access control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMindray
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelWATO EX-35Vet
Instrument TypeVeterinary Anesthesia and Monitoring System
Display10.4-inch TFT high-resolution touchscreen
Ventilation ModesVolume-Controlled (VCV), Pressure-Controlled (PCV), Pressure-Controlled Ventilation with Volume Guarantee (PCV-VG), Spontaneous Breathing Support
Minimum Tidal Volume5 mL
Gas Monitoring OptionsEtCO₂, Oxygen (O₂), Nitrous Oxide (N₂O), Halogenated Anesthetics (e.g., Isoflurane, Sevoflurane)
VaporizerPrecision V60 calibrated halogenated anesthetic vaporizer (CE & FDA cleared)
Breathing CircuitIntegrated dual-mode (rebreathing/non-rebreathing), tool-free soda lime canister replacement
Leak TestAutomated self-test with graphical troubleshooting guidance
Waste Gas ScavengingOptional passive or active scavenging system
ComplianceDesigned to meet IEC 60601-1, IEC 60601-2-13, ISO 80601-2-13, and applicable veterinary medical device regulatory requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiagenode
OriginBelgium
ModelUCD300
Operating Frequency20 kHz
Ultrasonic Power Output155 W / 310 W (dual-step adjustable)
Sample Volume Range5 µL – 20 mL
Maximum Throughput≥24 samples per run
Processing Chamber Volume750 mL
Dimensions (Controller)150 × 300 × 195 mm (W×D×H)
Dimensions (Processing Chamber)350 × 260 × 150 mm (W×D×H)
Weight20 kg
Timer Range0–60 sec or 0–15 min (on/off cycles)
Compatible VesselsPCR tubes, 1.5 mL, 10 mL, 15 mL, and 50 mL centrifuge tubes
Fragmentation Range (DNA)2 kb – <500 bp
Rotation SpeedProgrammable constant-speed rotation during sonication
ComplianceCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPanasonic
ModelMDF-U780V
Temperature Range–50 °C to –86 °C (0.1 °C adjustable)
Effective Volume736 L
Interior Dimensions (W×D×H)890 × 600 × 1380 mm
Exterior Dimensions (W×D×H)1030 × 875 × 1990 mm
Power Supply220 V, 50 Hz
Rated Input Power1185 W
Compressor TypeDual hermetic compressors (1100 W each)
RefrigerantsR404A / R508B (ozone-friendly)
InsulationPolyurethane foam + Vacuum Insulation Panels (VIP)
External CasingPowder-coated galvanized steel
Internal ChamberElectrogalvanized steel with polyester resin coating
Door Configuration1 outer door + 2 inner doors
Safety FeaturesHigh/low temperature alarm, power failure alarm, remote alarm contact, sensor self-diagnosis, compressor protection circuit
Standard Accessories1 set of keys, 3 stainless-steel shelves, 1 defrost scraper
Cooling MethodDirect cooling
Temperature ControlMicroprocessor-based digital controller with LED display
Monitoring Ports2 × 17 mm access ports (rear, lower-left)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelLoopster
Speed Range5–80 rpm
Adjustable Rotation Angle0°–90°
Timer Range1 s–5999 min
Platform Capacity2 kg (including fixtures)
Operating Temperature4–50 °C
Protection ClassIP21
Dimensions (W×D×H)300 × 360 × 300 mm
Weight3 kg
Power Supply100–240 V, 50/60 Hz
Display7-segment LED
Speed Resolution1 rpm per step
Duty CycleContinuous operation supported
Platform StackableNo
USB/RS232/Analog OutputNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelHS 501 Digital
Drive TypeReciprocal & Circular Orbital
Orbit Diameter30 mm
Speed Range0–300 rpm
Speed DisplayLED Digital
Load Capacity (incl. clamps)15 kg
Timer Range1–56 min
Timer DisplayAnalog Scale
Operating ModeTimed or Continuous
Input Power74 W
Motor Input Power70 W
Motor Output Power19 W
Duty Cycle100 % continuous operation
Ambient Temperature Range5–50 °C
Relative Humidity Limit≤80 %
Protection ClassIP21 (DIN EN 60529)
Voltage230 / 115 / 100 V
Frequency50/60 Hz
Dimensions (W × H × D)505 × 120 × 585 mm
Weight26 kg
Clamp AssemblyNot included — ordered separately
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeckman Coulter
OriginUSA
Instrument TypeAnalytical Flow Cytometer
Configuration OptionsUp to 3 Lasers / 13 Colors (CytoFLEX)
Fluorescence SensitivityFITC < 30 MESF, PE < 10 MESF
Small Particle Detection Limit≥80 nm (via VSSC)
Optical ArchitectureWavelength-Division Multiplexing (WDM) Detection
Regulatory ComplianceFDA 21 CFR Part 11–Ready
Software InterfaceDual-language (English/Chinese), Graphical User Interface (GUI)
Sorting CapabilityOptional Sort Module Available
Intended UseResearch-Only
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelVXR Basic Vibrax
Oscillation ModeOrbital
Orbit Diameter4 mm
Speed Range0–2200 rpm
Load Capacity (incl. clamp)2 kg
Motor Input/Output Power35 / 13.2 W
Operating ModeContinuous
Display TypeAnalog Scale
Dimensions (W × D × H)157 × 247 × 130 mm
Weight6.1 kg
Ambient Temperature Range5–40 °C
Relative Humidity Limit≤80 % RH
Ingress Protection RatingIP21
ComplianceDIN EN 60529
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMolecular Devices
OriginShanghai, China
ModelQPix FLEX
Detection MethodFluorescence Intensity
FunctionalityMultimodal
Automation LevelFully Automated
Assay TypeAutomated Microbial Identification & Colony Isolation
Detector TypeFluorescence Imaging Sensor
Sample HandlingIntegrated Liquid Handling, Streaking, Plating, and Colony Picking
DimensionsCompact Footprint (Designed for Benchtop & Anaerobic Chamber Integration)
Traceability2D Barcode Scanning for Microplate & Pick Log Registration
Compliance ContextSupports GLP/GMP-aligned workflows with full audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRoche Diagnostics
OriginSwitzerland
Instrument TypeDigital PCR System
ModelRoche Digital LC
Regulatory StatusCE-IVD, FDA-cleared for in vitro diagnostic use (where applicable)
ComplianceISO 13485, IVD Directive 98/79/EC, aligned with CLIA and CAP laboratory requirements
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMindray
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelWATO EX-65 Pro Vet
Instrument TypeIntegrated Veterinary Anesthesia & Ventilation System
Regulatory ClassificationClass II Medical Device (CN), CE-marked for Veterinary Use
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMolecular Devices
ModelMultiWash-C
TypeAutomated Microplate Washer
Plate Format96-well (flat-bottom, U-bottom, V-bottom)
Dispense Volume Range50–3000 µL (in 50 µL increments)
Accuracy & Precision @ 300 µL≤3%
Residual Volume≤1 µL/well
Wash Cycle Time (3 cycles, 3000 µL/well)<90 s (12-channel head), <125 s (8-channel head)
Oscillation3 adjustable frequencies
Aspiration/Dispense Speed3-speed control
Onboard Storage100 programs, up to 99 steps per program
Dimensions (W×H×D)46 × 30 × 40 cm
Weight (packed)13 kg
Power Input100–240 V, 50–60 Hz
Integrated SensorsLiquid level detection for 2 × 4 L wash bottles and 1 × 10 L waste bottle
ComplianceDesigned for GLP-compliant ELISA workflows
SoftwareStandalone touchscreen interface, no external PC required
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUSA
ModelBiacore S200
Sample CapacityOne 96-well or 384-well microplate
Injection Volume2–350 µL
Analysis Time per Cycle2–15 min
Temperature Control Range4°C to 45°C
Detection LimitNo theoretical lower molecular weight limit for analyte binding detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhichu
OriginGuangdong, China
ModelZCZY-VCN
Instrument TypeCO₂-Controlled Temperature-Regulated Orbital Shaker
Timer Range0–999.9 h
Oscillation Frequency10–250 rpm (Ø50 mm)
Oscillation AmplitudeØ50 mm (standard), Ø26 mm (optional)
Temperature Range4–60 °C (ambient: 23–25 °C)
Number of Shaking Platforms3
Temperature Uniformity±0.3 °C at 37 °C
CO₂ Control Range0–20 %
CO₂ Control Accuracy±0.1 %
DisplayLCD Touchscreen
Power SupplyAC 220 V ±10 %, 50–60 Hz
Noise Level<55 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMindray
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZ70 Vet
Instrument TypeVeterinary Diagnostic Ultrasound System
Display15-inch Full-View LCD Touchscreen
Application FocusCanine, Feline, Equine, Bovine, and Ovine Imaging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUSA
ModelAI800
Imaging Sensor8.3 MP cooled CCD
LensF0.74 fixed-focus科研级镜头
SNOW™ ModeReal-time signal-to-noise optimization algorithm
Light Sources7-channel LED fluorescence excitation (365–740 nm)
Sample CompatibilityGels, blots, multiwell plates, Petri dishes, membranes
SoftwareImageQuant TL with remote access capability
ComplianceDesigned for GLP/GMP-aligned workflows, audit-trail enabled via ImageQuant TL v10.3+
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhiChu
OriginGuangdong, China
ModelZCZY-CS9
Instrument TypeCO₂-Controlled Temperature-Shaking Incubator
Stacking Configuration3-Layer Modular Stack
Timer Range0–999.9 h
Oscillation Frequency10–250 rpm (Φ50 mm platform)
Oscillation AmplitudeΦ50 mm (standard), Φ26 mm (optional)
Temperature Range4–60 °C (ambient: 23–25 °C)
Temperature Uniformity±0.5 °C at 37 °C
Temperature Accuracy±0.1 °C
Humidity RangeAmbient to 90 % RH
Humidity Accuracy±5 % RH
Humidity Resolution1 % RH
CO₂ Range0–20 %
CO₂ Accuracy±0.1 % (IR sensor)
CO₂ Decay Time30 min (5.0 % → 4.5 %)
Platform Dimensions (L×W)1000 × 530 mm per layer
Max Capacity (per layer, stainless steel clamps)250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 18
Max Capacity (per layer, polymer clamps)250 mL × 66 or 500 mL × 45 or 1000 mL × 28 or 2000 mL × 15
Noise Level<55 dB(A)
Power SupplyAC 220 V ±10 %, 50–60 Hz
External Dimensions (W×D×H)1430 × 845 × 1740 mm (3-layer)
Net Weight~728 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMindray
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelePM 12M Vet
Instrument TypeElectrocardiography (ECG)-Enabled Multi-Parameter Veterinary Monitor
NIBP AlgorithmSpecies-Specific Cuff-Based Blood Pressure Algorithm
SpO₂ TechnologyMotion-Tolerant and Low-Perfusion Resistant Pulse Oximetry
ECG AnalysisMulti-Lead Digital Signal Processing with CrozFusion™ Signal Fusion
Expandable ModulesCO₂ (Capnography), IBP (Invasive Blood Pressure, up to 4 channels), Cardiac Output (C.O.), Anesthetic Gas (AG), O₂/CO₂ (Artema® Technology)
Display12.1-inch Capacitive Touchscreen with Gesture Support
Data StorageInternal Flash Memory + USB Export Capability
ComplianceIEC 60601-1, IEC 60601-2-51 (for Veterinary Monitors), ISO 13485 Certified Manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandDiagenode
OriginBelgium
Modelnew pico
Instrument TypeUltrasonic Cell Disruptor
Ultrasonic Power300 W
Operating Frequency40 kHz
Temperature Range4 °C to ambient
Maximum Sample Capacity16 tubes
Sample Volume Range20 µL – 2 mL
Cooling SystemIntegrated solenoid-valve-controlled recirculating chiller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhilchu
OriginGuangdong, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelZCZY-CSR8
Instrument TypeCO₂-Controlled Temperature-Shaking Incubator
Timer Range0–999.9 h
Oscillation Frequency10–250 rpm (Φ50 mm platform)
Oscillation AmplitudeΦ50 mm (standard), Φ26 mm (optional)
Temperature Range4–60 °C (ambient: 23–25 °C)
Number of Shaking Decks3
Temperature Uniformity±0.5 °C at 37 °C
Temperature Accuracy±0.1 °C
CO₂ Control Range0–20%
CO₂ Control Accuracy±0.1%
Noise Level<55 dB(A)
Max Load Capacity (stainless steel clamp)250 mL × 66 / 500 mL × 45 / 1000 mL × 28 / 2000 mL × 15 per deck
Deck Dimensions (L×W)928 mm × 530 mm
External Dimensions (L×W×H)1360 mm × 845 mm × 1740 mm (3-deck configuration)
Net Weight~596 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ModelHula Dancer digital
Instrument TypeOrbital Shaker
Oscillation ModeCircular
Orbit Diameter4.5 mm
Speed Range1200–2800 rpm
Speed ResolutionFixed or Adjustable (No Digital Display)
Load Capacity (incl. Clamp)0.1 kg
Temperature Operating Range5–40 °C
Ambient Temperature Range5–40 °C
Relative Humidity Limit≤80 % RH
Protection ClassIP42 (per DIN EN 60529)
Input Voltage100–240 V AC
Frequency50/60 Hz
Motor Input Power9.5 W
Motor Output Power5 W
Standby Power Consumption0.8 W
Continuous Operation Rated100 %
Dimensions (W × H × D)123 × 42 × 123 mm
Weight0.7 kg
Momentary Start FunctionYes
TimerNot integrated
Speed DisplayNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhilu
ModelZCLY-180
Instrument TypeCO₂-controlled incubator shaker
Timing Range0–999.9 h
Oscillation Frequency10–300 rpm (±1 rpm)
AmplitudeØ26 mm
Temperature Range4–60 °C (at ambient 23–25 °C)
Temperature Uniformity±0.8 °C (at 37 °C)
Temperature Resolution±0.1 °C
CO₂ Range0–20%
CO₂ Control Accuracy±0.1%
Number of Shaking Platforms3
Platform Size (L×W)485 × 485 mm
Max Capacity per Shelf250 mL × 25 / 500 mL × 16 / 1000 mL × 9
Internal ChamberR-cornered 304 stainless steel, seamless welded
DisplayLCD touchscreen with real-time multi-parameter overlay
Data Logging1-min interval, up to 3 months’ storage
ConnectivityUSB export
Power SupplyAC 220 V ±10%, 50–60 Hz
Dimensions (W×D×H)760 × 680 × 1280 mm
Net Weight~183 kg
Noise Level<55 dB(A)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCytiva
OriginUSA
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelÄKTA™ pure
Flow Rate RangeUp to 25 mL/min (ÄKTA™ pure 25) / Up to 150 mL/min (ÄKTA™ pure 150)
Pressure LimitUp to 20 MPa
Conductivity Range0.01–999.9 mS/cm
UV Detection Wavelengths280 nm, 254 nm (dual-channel fixed-wavelength)
Fraction CollectionProgrammable, time- or peak-triggered
Software PlatformUNICORN™ 7.x
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZhiChu
OriginGuangdong, China
ModelZCZY-VCS8
Instrument TypeCO₂-Regulated Temperature-Controlled Orbital Shaker
Timer Range0–999.9 h
Oscillation Frequency10–250 rpm (Ø50 mm), 10–300 rpm (Ø26 mm)
Oscillation AmplitudeØ50 mm (standard), Ø26 mm (optional)
Temperature Range4–60 °C (ambient 23–25 °C)
Number of Shaking Decks3
Temperature Uniformity±0.3 °C at 37 °C
Temperature Accuracy±0.1 °C
CO₂ Control Range0–20 %
CO₂ Control Accuracy±0.1 %
CO₂ Decay Time30 min (from 5.0 % to 4.5 %)
Deck Dimensions (L×W)900 × 530 mm
Noise Level<55 dB(A)
Power SupplyAC 220 V ±10 %, 50–60 Hz
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0