| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5100 |
| Application Scope | Solid, Liquid and Gas Samples |
| Combustion Technology | Dual-Mode High-Temperature Catalytic Combustion (950–1150 °C) |
| Detection Principle | UV-Fluorescence (S), Chemiluminescence (N), Microcoulometric Titration (Cl), IR Absorption (C) |
| Sample Throughput | Up to 120 samples/day (with auto-sampler) |
| Compliance | ASTM D5291, D3120, D4294, D5762, ISO 20846, ISO 14596, UOP 390, IP 287, EN ISO 14596 |
| Safety Features | Integrated self-diagnostic system, real-time parameter monitoring, carbon deposit prevention via FIRE sensor technology |
| Automation | Optional high-capacity autosampler (up to 120 positions), gas sampling module (for LPG, natural gas, refinery streams) |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 4000 C |
| Measurement Principle | High-Temperature Combustion (HTC) coupled with NDIR and Coulometric detection |
| Detection Elements | Total Carbon (TC), Total Sulfur (TS), Total Nitrogen (TN), Total Chlorine (Cl) |
| Sample Types | Solid organic & inorganic matrices (soils, sediments, sludges, solid waste, coal, polymers) |
| Detection Range | ppm to wt% (element-dependent) |
| Combustion Temperature | up to 1,350 °C |
| Combustion Tube Material | Composite ceramic |
| Detectors | Dual-channel NDIR for CO₂/SO₂ |
| Automation | Integrated autosampler (up to 60 positions), self-diagnostic system, automatic calibration verification |
| Compliance | Designed to meet ASTM D5373, D7359, ISO 1171, ISO 29541, EN 15407, USP <28>, EPA Method 9096A |
| Software | multiWin v5.0 with 21 CFR Part 11 compliance mode, audit trail, electronic signatures, GLP/GMP reporting templates |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 N/S |
| Detection Principle | High-Temperature Combustion coupled with UV-Vis and IR Spectrophotometry |
| Detection Range | ppb to % level for N and S |
| Analysis Time | 2–5 min per sample |
| Sample Types | Liquids, Gases, LPG, LNG |
| Automation | Fully automated, 24/7 unattended operation |
| Detector Technology | HiPerSens UV-Vis & IR dual-channel detection |
| Linear Dynamic Range | >6 orders of magnitude |
| Detection Limits | <0.5 ppb (N), <0.3 ppb (S) |
| Footprint | <0.3 m² |
| Interface | 10.1" capacitive touchscreen |
| Compliance | ASTM D5291, D7183, ISO 20846, ISO 29540, EN ISO 14852, USP <233>, FDA 21 CFR Part 11 ready |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | multi EA 5010 SPMO |
| Detection Principle | High-Temperature Combustion Coupled with UV-Fluorescence (S), Chemiluminescence (N), IR Absorption (C), and Microcoulometric Titration (Cl) |
| Detection Limits | <0.02 mg/kg (S), <0.05 mg/kg (N), <0.1 mg/kg (C), <0.05 mg/kg (Cl) |
| Sample Forms | Liquids, Gases, Liquefied Petroleum Gas (LPG), Liquefied Natural Gas (LNG), Solids (with optional solid module) |
| Analysis Time | 2–5 min per sample |
| Throughput | Up to 120 samples/day (unattended) |
| Linear Dynamic Range | 4–6 orders of magnitude |
| Compliance | ASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 975, IP 542, EN ISO 14596, USP <233>, FDA 21 CFR Part 11 (with optional audit trail & electronic signature) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Easy Na |
| Measurement Principle | Potentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required) |
| Compliance | Designed for GB 28050–2011 nutritional labeling requirements |
| Software Integration | EasyDirect™ Data Acquisition Software |
| Reagent System | NaCl-based ISA (no AgNO₃ required) |
| Target Matrix | Food & Beverage samples (liquid, homogenized, or acid-digested) |