BrandAnalytik Jena
OriginGermany
Modelmulti EA 5100
Application ScopeSolid, Liquid and Gas Samples
Combustion TechnologyDual-Mode High-Temperature Catalytic Combustion (950–1150 °C)
Detection PrincipleUV-Fluorescence (S), Chemiluminescence (N), Microcoulometric Titration (Cl), IR Absorption (C)
Sample ThroughputUp to 120 samples/day (with auto-sampler)
ComplianceASTM D5291, D3120, D4294, D5762, ISO 20846, ISO 14596, UOP 390, IP 287, EN ISO 14596
Safety FeaturesIntegrated self-diagnostic system, real-time parameter monitoring, carbon deposit prevention via FIRE sensor technology
AutomationOptional high-capacity autosampler (up to 120 positions), gas sampling module (for LPG, natural gas, refinery streams)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Modelmulti EA 4000 C
Measurement PrincipleHigh-Temperature Combustion (HTC) coupled with NDIR and Coulometric detection
Detection ElementsTotal Carbon (TC), Total Sulfur (TS), Total Nitrogen (TN), Total Chlorine (Cl)
Sample TypesSolid organic & inorganic matrices (soils, sediments, sludges, solid waste, coal, polymers)
Detection Rangeppm to wt% (element-dependent)
Combustion Temperatureup to 1,350 °C
Combustion Tube MaterialComposite ceramic
DetectorsDual-channel NDIR for CO₂/SO₂
AutomationIntegrated autosampler (up to 60 positions), self-diagnostic system, automatic calibration verification
ComplianceDesigned to meet ASTM D5373, D7359, ISO 1171, ISO 29541, EN 15407, USP <28>, EPA Method 9096A
SoftwaremultiWin v5.0 with 21 CFR Part 11 compliance mode, audit trail, electronic signatures, GLP/GMP reporting templates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Modelmulti EA 5010 N/S
Detection PrincipleHigh-Temperature Combustion coupled with UV-Vis and IR Spectrophotometry
Detection Rangeppb to % level for N and S
Analysis Time2–5 min per sample
Sample TypesLiquids, Gases, LPG, LNG
AutomationFully automated, 24/7 unattended operation
Detector TechnologyHiPerSens UV-Vis & IR dual-channel detection
Linear Dynamic Range>6 orders of magnitude
Detection Limits<0.5 ppb (N), <0.3 ppb (S)
Footprint<0.3 m²
Interface10.1" capacitive touchscreen
ComplianceASTM D5291, D7183, ISO 20846, ISO 29540, EN ISO 14852, USP <233>, FDA 21 CFR Part 11 ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnalytik Jena
OriginGermany
Modelmulti EA 5010 SPMO
Detection PrincipleHigh-Temperature Combustion Coupled with UV-Fluorescence (S), Chemiluminescence (N), IR Absorption (C), and Microcoulometric Titration (Cl)
Detection Limits<0.02 mg/kg (S), <0.05 mg/kg (N), <0.1 mg/kg (C), <0.05 mg/kg (Cl)
Sample FormsLiquids, Gases, Liquefied Petroleum Gas (LPG), Liquefied Natural Gas (LNG), Solids (with optional solid module)
Analysis Time2–5 min per sample
ThroughputUp to 120 samples/day (unattended)
Linear Dynamic Range4–6 orders of magnitude
ComplianceASTM D5453, D7183, D7039, ISO 20846, ISO 20884, UOP 975, IP 542, EN ISO 14596, USP <233>, FDA 21 CFR Part 11 (with optional audit trail & electronic signature)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMETTLER TOLEDO
OriginSwitzerland
ModelEasy Na
Measurement PrinciplePotentiometric Standard Addition Method (Sodium-Selective Electrode, Non-Calibration Required)
ComplianceDesigned for GB 28050–2011 nutritional labeling requirements
Software IntegrationEasyDirect™ Data Acquisition Software
Reagent SystemNaCl-based ISA (no AgNO₃ required)
Target MatrixFood & Beverage samples (liquid, homogenized, or acid-digested)