| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C5000 |
| Compliance | DIN 51900, ASTM D240, ISO 1928, BS EN ISO 1928 |
| Measurement Modes | Adiabatic (~14–18 min), Isothermal (~22 min), Dynamic (~10 min) |
| Automation Features | Auto-filling, temperature equilibration & draining of water jacket |
| Accessories Included | C5000 control unit, C5003 measurement unit, C5012 halogen-resistant bomb, C5004 heat exchanger |
| Key | Brand: IKA |
|---|---|
| Origin | Germany |
| Model | C 5000 Controlled-Mode Configuration 2/10 |
| Certification | DIN 51900, ASTM D240, ISO 1928, BSI compliant |
| Automation Features | Auto-filling, temperature regulation & draining of water jacket |
| Software | C5040 CalWin (data acquisition, calculation, audit trail, GLP-compliant reporting) |
| Accessories Included | C5000 control unit, C5003 measurement unit, C5010 standard combustion bomb, C5004 heat exchanger |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | Amersham Typhoon |
| Detection Modes | Fluorescence, Phosphor Imaging, Chemiluminescence, Digital Radiography |
| Laser Wavelengths | 488 nm (LD), 532 nm (SHG), 635 nm (LD), 685 nm (LD), 785 nm (LD) |
| Isotope Compatibility | ³H, ¹¹C, ¹⁴C, ¹²⁵I, ¹⁸F, ³²P, ³³P, ³⁵S, ⁹⁹ᵐTc and other ionizing radiation sources |
| Dynamic Range | > 5 decades |
| Bit Depth | 16-bit |
| Imaging Area | 40 × 46 cm |
| Pixel Resolution Options | 10, 25, 50, 100, 200 µm (pre-scan at 1000 µm) |
| Standard Filters | IP 390BP, Cy2 525BP20, Cy3 570BP20, Cy5 670BP30, IRshort 720BP20, IRlong 825BP30, LPR660 |
| Sample Platforms | Fluorescence stage, Multi-sample stage, Phosphor Imaging (IP) stage |
| Dimensions (W×H×D) | 900 × 400 × 800 mm |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz |
| Operating Temperature | 15–30 °C |
| Relative Humidity | 20–70% RH (non-condensing) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C 7000 |
| Measuring Range (Max) | 30000 J |
| Measurement Mode | Dual-Dry (ISO 1928) |
| Typical Measurement Time | ~3 min |
| Repeatability (1 g benzoic acid, NBS 39i) | 0.2 % RSD |
| Temperature Measurement Resolution | 0.0001 K |
| Max Operating Temperature | 30 °C |
| Cooling Medium | Tap water |
| Cooling Flow Rate | 120–180 L/h |
| Cooling Medium Temp. Range | 12–30 °C |
| Cooling System Working Pressure | ≤9 bar |
| Max Oxygen Pressure | 40 bar |
| Oxygen Bomb Detection | Yes |
| C7010 Combustion Bomb Included | Yes |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 43 kg |
| Ambient Operating Conditions | 18–30 °C, ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz, 260 W |
| Interfaces | RS232 (balance, printer, PC), Centronics (printer) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C7000 |
| Measurement Range | up to 30,000 J |
| Measurement Principle | Dual-Dry Bomb Calorimetry (ISO 1928) |
| Measurement Time | ~3 min |
| Temperature Resolution | 0.0001 K |
| Operating Ambient Temperature | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap Water (12–30 °C), Flow Rate: 120–180 L/h |
| Cooling System Pressure Rating | 9 bar |
| Dimensions (W×D×H) | 800 × 395 × 490 mm |
| Weight | 43 kg |
| Power Supply | 220–240 V, 50/60 Hz, 260 W |
| Interfaces | RS232 (balance, printer, PC), Centronics (printer) |
| Oxygen Bomb Recognition | Auto-coded C7010 anti-halogen bomb |
| Compatible Crucible | C14 combustion crucible |
| Software | C5040 Calwin (menu-driven, instrument control & data management) |
| Key | Brand: IKA |
|---|---|
| Origin | Germany |
| Model | C 6000 System 2/12 |
| Compliance | DIN 51900, ISO 1928, ASTM D240/D4809/D1989, GOST R 50804, GB/T 213 |
| Operating Modes | Isoperibol (constant jacket temperature) and Dynamic (controlled-rate temperature ramp) |
| Initial Temperature Options | 22 °C, 25 °C, 30 °C |
| Bomb Type | Spherical-head C 6012 halogen-resistant combustion bomb |
| Interface Options | Ethernet (FTP/server printing), USB, SD card slot, RS-232 (for balance/printers), optional cooling unit interface (e.g., KV600) |
| Software Compatibility | IKA Calwin C 6040 (sold separately), LIMS integration via ASTM E1384 or ISO/IEC 17025-compliant data export |
| Calibration Support | Certified benzoic acid traceability to NIST SRM 39j, automatic correction per ISO 1928 Annex B |
| Brand | Cytiva |
|---|---|
| Origin | USA |
| Model | Amersham Typhoon NIR |
| Excitation Wavelengths | 685 nm & 785 nm (integrated diode lasers) |
| Detection | Dual PMT detectors |
| Dynamic Range | 5 decades |
| Image Depth | 16-bit |
| Scan Area | 40 × 46 cm |
| Pixel Resolution Options | 10, 25, 50, 100, 200 µm (standard) |
| Standard Filters | IRshort 720BP20, IRlong 825BP30 |
| Optional Filters | Cy2 LPB515, Cy3 LPG550, Cy5 LPR660, IP 390BP, Cy2 525BP20, Cy3 570BP20, Cy5 670BP30 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | C1 Package 1/10 |
| Compliance | DIN 51900, ISO 1928 |
| Cooling Requirement | RC 2 basic recirculating chiller (included) |
| Software Compatibility | C6040 Calwin (optional) |
| Sample Capacity | Up to 500 initial tests with included consumables |
| Includes | C1.10 combustion vessel, C5010.5 large crucible holder, C6 large quartz crucible, calibration records (n=25), ignition wires, combustion aids, and accessory kit |