Empowering Scientific Discovery

Beijing Furbon Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK16591
Test Method ComplianceASTM D3278, D3828, D4206
Temperature Range–30°C to +300°C
Sample Volume2 mL
Test Duration~60 seconds
Cup MaterialAnodized Aluminum
ConfigurationClosed-Cup
CertificationCE, UL Listed
Regulatory AlignmentSupports GLP/GMP audit trails and 21 CFR Part 11-compliant data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
Manufacturer StatusAuthorized Distributor
Product OriginImported
ModelK47001
PricingUpon Request
Test MethodOpen-Cup
Operation ModeFully Automatic
Applicable StandardASTM E659
Repeatability±5%
Ignition MechanismFully Automated
Temperature RangeAmbient to 1200 °C
Temperature Control Accuracy±1 °C
Power Supply230 V, 50/60 Hz, Single-Phase, 7.7 A
Dimensions (W×D×H)37″ × 17″ × 25″ (94 cm × 43.2 cm × 63.5 cm)
Net Weight85 lb (38.6 kg)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelK72000
Detection MethodCleveland Open Cup (COC)
Operation ModeFully Automated
Temperature RangeAmbient to 405°C
Ignition SourcesElectric Spark and Gas Flame
Repeatability±1°C
Compliant StandardsASTM D92, GB/T 3536, IP 36/403, ISO 2592, AFNOR T60-118, EN 22592, DIN 51376
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
ModelK27000
Standards ComplianceASTM D1322, ISO 3014
Dimensions18 cm Ø × 47 cm H
Net Weight4.5 kg
ConstructionBrass lamp body, copper-plated viewing window, adjustable aluminum base, calibrated 0–50 mm black glass scale, cotton wick assembly with air vent, candle socket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelFP CC-420A
Detection MethodClosed-Cup (Continuous)
Operation ModeFully Automatic
Temperature Range0 °C to 260 °C (–30 °C to 420 °C with optional low-/high-temperature modules)
Ignition MethodHigh-Voltage Electronic Spark
Heating Rate2.5 ± 0.3 °C/min, 5.5 ± 0.5 °C/min, or user-defined (0.5–12 °C/min)
Temperature Accuracy±0.1 °C
Pressure Measurement Range0–200 kPa
Sample Volume1 mL or 2 mL
Stirring Speed50–300 rpm
Standards ComplianceASTM D6450, ASTM D7094, ASTM D93, ASTM D3828, GB/T 261, GB/T 21615, GB/T 5208, GB/T 21790, SH/T 0768, SN/T 3077.1 & 3077.2, DL/T 1354
InterfaceRS232 ×1, RJ45 ×1, USB ×2
Power SupplyAC 220 V / 50 Hz
Power Consumption300 W
Dimensions225 mm × 310 mm × 415 mm
Weight13.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKoehler
OriginUSA
Manufacturer StatusAuthorized Distributor
Origin CategoryImported
ModelK71000
Detection MethodClosed-Cup
Operation ModeFully Automatic
Temperature RangeAmbient to 405°C
Ignition SourceSwitchable Gas or Electric Ignition
Applicable StandardsASTM D93 Methods A, B & C, IP 34, ISO 2719, DIN EN 22719, JIS K2265, NF M 07-019