| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K16591 |
| Test Method Compliance | ASTM D3278, D3828, D4206 |
| Temperature Range | –30°C to +300°C |
| Sample Volume | 2 mL |
| Test Duration | ~60 seconds |
| Cup Material | Anodized Aluminum |
| Configuration | Closed-Cup |
| Certification | CE, UL Listed |
| Regulatory Alignment | Supports GLP/GMP audit trails and 21 CFR Part 11-compliant data integrity workflows |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | K47001 |
| Pricing | Upon Request |
| Test Method | Open-Cup |
| Operation Mode | Fully Automatic |
| Applicable Standard | ASTM E659 |
| Repeatability | ±5% |
| Ignition Mechanism | Fully Automated |
| Temperature Range | Ambient to 1200 °C |
| Temperature Control Accuracy | ±1 °C |
| Power Supply | 230 V, 50/60 Hz, Single-Phase, 7.7 A |
| Dimensions (W×D×H) | 37″ × 17″ × 25″ (94 cm × 43.2 cm × 63.5 cm) |
| Net Weight | 85 lb (38.6 kg) |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K72000 |
| Detection Method | Cleveland Open Cup (COC) |
| Operation Mode | Fully Automated |
| Temperature Range | Ambient to 405°C |
| Ignition Sources | Electric Spark and Gas Flame |
| Repeatability | ±1°C |
| Compliant Standards | ASTM D92, GB/T 3536, IP 36/403, ISO 2592, AFNOR T60-118, EN 22592, DIN 51376 |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Model | K27000 |
| Standards Compliance | ASTM D1322, ISO 3014 |
| Dimensions | 18 cm Ø × 47 cm H |
| Net Weight | 4.5 kg |
| Construction | Brass lamp body, copper-plated viewing window, adjustable aluminum base, calibrated 0–50 mm black glass scale, cotton wick assembly with air vent, candle socket |
| Brand | Young Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FP CC-420A |
| Detection Method | Closed-Cup (Continuous) |
| Operation Mode | Fully Automatic |
| Temperature Range | 0 °C to 260 °C (–30 °C to 420 °C with optional low-/high-temperature modules) |
| Ignition Method | High-Voltage Electronic Spark |
| Heating Rate | 2.5 ± 0.3 °C/min, 5.5 ± 0.5 °C/min, or user-defined (0.5–12 °C/min) |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–200 kPa |
| Sample Volume | 1 mL or 2 mL |
| Stirring Speed | 50–300 rpm |
| Standards Compliance | ASTM D6450, ASTM D7094, ASTM D93, ASTM D3828, GB/T 261, GB/T 21615, GB/T 5208, GB/T 21790, SH/T 0768, SN/T 3077.1 & 3077.2, DL/T 1354 |
| Interface | RS232 ×1, RJ45 ×1, USB ×2 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 300 W |
| Dimensions | 225 mm × 310 mm × 415 mm |
| Weight | 13.5 kg |
| Brand | Koehler |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | K71000 |
| Detection Method | Closed-Cup |
| Operation Mode | Fully Automatic |
| Temperature Range | Ambient to 405°C |
| Ignition Source | Switchable Gas or Electric Ignition |
| Applicable Standards | ASTM D93 Methods A, B & C, IP 34, ISO 2719, DIN EN 22719, JIS K2265, NF M 07-019 |