Empowering Scientific Discovery

Beijing Huayi Sanpu Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-20
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Capacity20 positions
Vial Sizes Supported10 mL and 20 mL
Oven Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 260 °C (±1 °C accuracy, 1 °C increment)
Loop Volume20 mL standard
Temperature Control Stability±0.5 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-6890S
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Capacity9 positions
Vial Size20 mL (customizable: 10 mL, 50 mL)
Oven Temperature RangeAmbient to 350 °C (1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 180 °C (1 °C increment)
Temperature Accuracy< ±0.5 °C
Pressure Control Range0–0.2 MPa (up to 0.7 MPa optional)
Pressure MonitoringDigital display, 0–0.2 MPa
RSD for Repeatability< 1% (GC-dependent)
Dimensions260 × 360 × 420 mm
Weight~15 kg
Power SupplyAC 220 V ±10%, 50 Hz
Operating Environment10–40 °C, RH < 85%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-8890
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity20 positions
Vial Size20 mL (customizable: 10 mL, 50 mL)
Oven Temperature RangeAmbient to 200 °C (1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 180 °C / Ambient to 150 °C (1 °C increment)
Temperature Control Accuracy< ±0.5 °C
Temperature Uniformity (Gradient)< ±0.5 °C
Pressurization Range0–0.2 MPa (0–0.7 MPa optional)
Pressure MonitoringDigital display, 0–0.2 MPa
RSD for Repeatability< 1% (GC-dependent)
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Operating Environment10–40 °C, RH < 85%
Dimensions (W×D×H)570 × 330 × 265 mm
Weight~25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-50
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity50 positions
Vial Size Compatibility10 mL and 20 mL standard crimp-top vials
Oven Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 260 °C (±1 °C accuracy, 1 °C increment)
Quantitative Loop Volume1 mL
External Event Control Channels15
Timing Resolution0.1–99 minutes (timing error <0.1%)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
Heated Incubation Zones4 independent zones
RepeatabilityRSD <1% (dependent on GC system performance and operator technique)
Power Requirement<1000 VA
Trigger Signal Output Latency<2 s
Dimensions (H×W×D)580 × 564 × 666 mm
Net Weight~40 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0