BrandHuayisanpu
OriginBeijing, China
ModelAHS-20
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Vial Capacity20 positions
Vial Sizes Supported10 mL and 20 mL
Oven Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 260 °C (±1 °C accuracy, 1 °C increment)
Loop Volume20 mL standard
Temperature Control Stability±0.5 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelATDS-3440
Instrument TypeTwo-Stage Thermal Desorber
Automation LevelSemi-Automatic
Primary Desorption Temp RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Secondary Desorption Temp RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment, >3000 °C/min ramp rate)
Cold Trap Temp RangeAmbient to −40 °C (±1 °C accuracy, 1 °C increment)
Valve & Transfer Line Temp RangeAmbient to 260 °C (±1 °C accuracy, 1 °C increment)
Sample Capacity1 tube per run
Desorption Recovery>98% (toluene, 0.1 µL, 10:1 split)
Peak Width (FWHM)<3 s
RSD<2.5% (GC-dependent)
Carrier Gas Flow0–100 mL/min (adjustable, visual indicator)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
External Event Control15 programmable events
Event Timing Range0.1–99 min (<0.1% timing error)
Tube MaterialsStainless steel, quartz glass, fused silica capillary (optional)
Power Consumption<1000 VA
GC Trigger Latency<2 s
Dimensions (H×W×D)470×500×380 mm
Weight~35 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelCAAM-2001C
Detection ElementsNa, K, Mg, Ca, Cr, Mn, Fe, Co, Ni, Pt, Au, Cu, Ag, Zn, Cd, Pb, Bi, Li
Detection Limit0.002 µg/mL (for Cu)
Atomizer Temperature Control Range+15 °C to +35 °C
Grating1800 lines/mm
Wavelength Range190–900 nm
Spectral Bandwidth0.1, 0.2, 0.4, 1.0, 2.0 nm (auto-selectable)
Wavelength Accuracy±0.15 nm
Baseline Drift (static)≤±0.002 A/30 min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelPTC-50
Sample Capacity50 positions
Injection PrecisionRSD < 10%
Trap Temperature RangeAmbient to 380 °C
Purge Vial Heating RangeAmbient to 250 °C
Vial Cooling Range4–10 °C
Cold Trap Temperature RangeAmbient to −40 °C
Water Removal Trap RangeAmbient to −30 °C
Desorption Rate>2000 °C/min
Water Trap Desorption RangeAmbient to 150 °C
Transfer Line TemperatureAmbient to 250 °C
Carrier Gas Pressure Regulation0–0.4 MPa
Purge Flow Rate0–100 mL/min
Trap MaterialsStainless steel / quartz / fused silica capillary (configurable)
Programmable External Events15
Timing Resolution0.1–99 min (accuracy <0.1%)
Power Consumption<1000 VA
Dimensions (H×W×D)580 × 640 × 850 mm
Weight~50 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelATDS-3440S-II
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 380°C (±0.5°C accuracy, 1°C increment)
Secondary Desorption Temp RangeAmbient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate)
Cold Trap Temp RangeAmbient to –40°C (±1°C accuracy, 1°C increment)
Valve & Transfer Line Temp RangeAmbient to 260°C (±1°C accuracy, 1°C increment)
Sample Capacity40 tubes
Desorption Recovery>98% (toluene, 0.1 µL, 10:1 split)
Peak Width (FWHM)<3 s
RSD<2.5% (system-dependent, GC and operator performance included)
Power Consumption<1000 VA
Dimensions (H×W×D)470 × 490 × 450 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelADHS-8890B
Instrument TypeWater & Soil Integrated Purge-and-Trap System
Sample Tray Capacity20 positions
Injection PrecisionRSD < 10%
Trap Temperature RangeAmbient to 380 °C
Purge Vial Heating RangeAmbient to 250 °C
Vial Cooling Range4–10 °C
Cold Trap (Desorption) RangeAmbient to –40 °C
Water Removal Trap RangeAmbient to –30 °C
Desorption Ramp Rate>250 °C/min (low-voltage safe design)
Transfer Line & Valve Block TempAmbient to 250 °C
Carrier Gas Pressure Regulation0–0.4 MPa
Purge Flow Rate0–500 mL/min
Trap Tube MaterialsStainless steel / Quartz / Fused silica capillary (customizable)
Adsorbent OptionsCustom-fill available
Programmable External Events7 channels
Timing Resolution0.1–99 min (timing accuracy <0.1%)
Pneumatic Actuation Pressure<0.4 MPa
System Pressure Rating>0.4 MPa
Analytical Repeatability (GC-coupled)RSD < 2.5%
Power Consumption<1000 VA
Trigger Signal Latency<2 s
Dimensions (H×W×D)500 × 400 × 650 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelATDS-3440S
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 380°C, ±0.5°C accuracy, 1°C increment
Secondary Desorption Temp RangeAmbient to 380°C, ±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate
Cold Trap Temp RangeAmbient to –40°C (ambient-dependent), ±1°C accuracy, 1°C increment
Valve & Transfer Line Temp RangeAmbient to 260°C, ±1°C accuracy, 1°C increment
Sample Capacity30 tubes
Desorption Recovery>98% (toluene, 0.1 µL, 10:1 split)
Peak Width (FWHM)<3 s
RSD<2.5% (GC-dependent)
Power Consumption<1000 VA
Dimensions (H×W×D)470 × 490 × 450 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelAFS-100
Detection ElementsAs, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au
Linear RangeDual-channel ≥ 0.999
Detection LimitDual-channel ≤ 0.03 ng/mL
Atomizer Temperature Control Range15–30 °C
Operating Ambient Temperature15–30 °C
Relative Humidity≤75%
Argon Supply Pressure0.2–0.3 MPa (regulated to 0.2 MPa)
Alarm Threshold<0.15 MPa
Power Supply220 V ± 22 V AC
Host Power Consumption≤400 W
Warm-up Time30 min
RepeatabilityDual-channel ≤1%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-6890S
Instrument TypeStatic Headspace Sampler
Automation LevelSemi-Automatic
Sample Vial Capacity9 positions
Vial Size20 mL (customizable: 10 mL, 50 mL)
Oven Temperature RangeAmbient to 350 °C (1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 180 °C (1 °C increment)
Temperature Accuracy< ±0.5 °C
Pressure Control Range0–0.2 MPa (up to 0.7 MPa optional)
Pressure MonitoringDigital display, 0–0.2 MPa
RSD for Repeatability< 1% (GC-dependent)
Dimensions260 × 360 × 420 mm
Weight~15 kg
Power SupplyAC 220 V ±10%, 50 Hz
Operating Environment10–40 °C, RH < 85%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelADHS-8890A
Sample Capacity20 positions
Injection PrecisionRSD < 2.5% (GC-dependent)
Trap Temperature RangeAmbient to 380 °C
Purge Vial Heating RangeAmbient to 250 °C
Chilled Vial Temperature Range4–10 °C
Cold Trap Temperature RangeAmbient to −40 °C
Water Removal Trap RangeAmbient to −30 °C
Desorption Ramp Rate>250 °C/min
Carrier Gas Pressure Regulation0–0.4 MPa
Purge Flow Rate0–500 mL/min
Tubing & Line Heating RangeAmbient to 250 °C
Power Consumption<1000 VA
Dimensions (H×W×D)500×400×650 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelATDS-4133
Automation LevelFully Automated
Primary Desorption Temp RangeAmbient to 380°C (±0.5°C accuracy, 1°C increment)
Secondary Desorption Temp RangeAmbient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate)
Cold Trap Temp RangeAmbient to −40°C (±1°C accuracy, 1°C increment)
Valve & Transfer Line Temp RangeAmbient to 260°C (±1°C accuracy)
Sample Pathway Temp RangeAmbient to 200°C (±1°C accuracy)
Sample Capacity50 tubes
Desorption Recovery>98% (toluene, 0.1 µL, 10:1 split ratio)
Peak Width (FWHM)<3 s
RSD<2.5%
Tube MaterialStainless steel
Trap OptionsStainless steel, quartz glass, or fused silica capillary
Carrier Gas Flow0–100 mL/min (adjustable with flow indicator)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
External Event Control15 programmable events
Event Timing Range0.1–99 min (<0.1% timing error)
Power Consumption<1000 VA
GC Trigger Latency<2 s
Dimensions (H×W×D)500 × 485 × 650 mm
Weight~45 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelATDS-51
Instrument TypeDual-stage thermal desorber
Automation LevelFully automated
Primary Desorption Temperature Range50–380 °C
Secondary Desorption Temperature Range150–380 °C
Valve & Transfer Line Temperature RangeAmbient to 260 °C
Cold Trap Temperature RangeAmbient to −40 °C
Temperature Control Accuracy< ±0.1 °C
Peak Width (FWHM)< 3 s
Desorption Efficiency>98% (toluene, 0.1 µL, 10:1 split ratio)
Sample Capacity51 positions
ComplianceDesigned for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-8890
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automatic
Sample Tray Capacity20 positions
Vial Size20 mL (customizable: 10 mL, 50 mL)
Oven Temperature RangeAmbient to 200 °C (1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 180 °C / Ambient to 150 °C (1 °C increment)
Temperature Control Accuracy< ±0.5 °C
Temperature Uniformity (Gradient)< ±0.5 °C
Pressurization Range0–0.2 MPa (0–0.7 MPa optional)
Pressure MonitoringDigital display, 0–0.2 MPa
RSD for Repeatability< 1% (GC-dependent)
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Operating Environment10–40 °C, RH < 85%
Dimensions (W×D×H)570 × 330 × 265 mm
Weight~25 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelATDS-3430S
Automation LevelFully Automated
Desorption Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve Temperature RangeAmbient to 260 °C (±1 °C)
Transfer Line Temperature RangeAmbient to 260 °C (±1 °C)
Cold Trap TemperatureAmbient
Temperature Stability< ±1 °C
Desorption Recovery Rate>98% (toluene, 0.1 µL, 10:1 split ratio)
Peak Width (FWHM)<3 s
Sample Capacity30 tubes
Programmable EventsUp to 15
Event Timing Range0.1–99 min (<0.1% timing error)
Carrier Gas Flow0–100 mL/min (adjustable, digital indication)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
RSD<2.5% (GC-dependent)
Power Consumption<1000 VA
Trigger Signal Output Delay<2 s
Dimensions (H×W×D)470×490×450 mm
Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelAHS-50
Instrument TypeStatic Headspace Sampler
Automation LevelFully Automated
Sample Tray Capacity50 positions
Vial Size Compatibility10 mL and 20 mL standard crimp-top vials
Oven Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve & Transfer Line Temperature RangeAmbient to 260 °C (±1 °C accuracy, 1 °C increment)
Quantitative Loop Volume1 mL
External Event Control Channels15
Timing Resolution0.1–99 minutes (timing error <0.1%)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
Heated Incubation Zones4 independent zones
RepeatabilityRSD <1% (dependent on GC system performance and operator technique)
Power Requirement<1000 VA
Trigger Signal Output Latency<2 s
Dimensions (H×W×D)580 × 564 × 666 mm
Net Weight~40 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelATDS-3430
Instrument TypeSingle-Stage Thermal Desorber
Automation LevelSemi-Automatic
Desorption Temperature RangeAmbient to 380 °C (±0.5 °C accuracy, 1 °C increment)
Valve Temperature RangeAmbient to 260 °C (±1 °C)
Transfer Line Temperature RangeAmbient to 260 °C (±1 °C)
Cold Trap TemperatureAmbient
Temperature Stability< ±1 °C
Desorption Recovery>98% (toluene, 0.1 µL, 10:1 split ratio)
Peak Width (FWHM)<3 s
Sample Capacity1 tube per run
Carrier Gas Flow0–100 mL/min (adjustable, with flow indicator)
Pneumatic Actuation Pressure<0.4 MPa (adjustable)
System Pressure Rating>0.4 MPa
Timing Resolution0.1–99 min (timing error <0.1%)
Programmable External Events15
Power Consumption<1000 VA
Dimensions (H×W×D)470×500×380 mm
Weight~35 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeijing Huayisanpu
OriginBeijing, China
ModelCAAM-2001D
Detection ElementsNa, K, Mg, Ca, Cr, Mn, Fe, Co, Ni, Pt, Au, Cu, Ag, Zn, Cd, Pb, Bi, Li
Detection Limit0.002 µg/mL
Wavelength Range190–900 nm
Grating Density1800 lines/mm
Spectral Bandwidth0.1/0.2/0.4/1.0/2.0 nm (auto-selectable)
Wavelength Accuracy±0.15 nm
Baseline Drift (static)≤±0.002 A/30 min
Characteristic Concentration (Cu)0.015 µg/mL/1%
Precision (RSD)≤0.5%
Lamp Positions8-slot automated turret with auto-alignment
Background CorrectionD₂ lamp (up to 1 A)
AtomizationAir-acetylene flame
NebulizerMetal-sheathed high-efficiency glass nebulizer
Burner HeadTitanium alloy
Power Requirement220 V ±5–10%, 50/60 Hz, 5000 VA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelPTC-100
Sample Capacity100-position carousel
Injection PrecisionRSD < 2.5% (GC-dependent)
Trap Temperature RangeAmbient to 380 °C
Purge Heating TemperatureAmbient to 250 °C
Sample Chilling Temperature4–10 °C
Cold Trap TemperatureAmbient to −40 °C
Water Removal Trap TemperatureAmbient to −30 °C
Desorption Ramp Rate>2000 °C/min (low-voltage controlled)
Purge Flow Control0–100 mL/min, adjustable with digital readout
Carrier Gas Pressure Regulation0–0.4 MPa
Programmable External Events15 independent time-controlled functions (0.1–99 min, timing accuracy <0.1%)
Sample Vial FormatStandard 40 mL vials
System Dimensions580 × 640 × 850 mm (H×W×D)
Weight~50 kg
Power Consumption<1000 VA
Interlock Signal Latency<2 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuayisanpu
OriginBeijing, China
ModelTDS-3410
Temperature RangeAmbient to 400 °C
Gas Flow Rate10–250 mL/min
Tube Capacity12 tubes
Temperature Control Resolution1 °C
Temperature Accuracy±0.5% of setpoint
Timer Range0–655 min
Power Consumption<500 W
Dimensions (W×D×H)170×390×400 mm
Weight~8 kg