| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-20 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Capacity | 20 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Loop Volume | 20 mL standard |
| Temperature Control Stability | ±0.5 °C |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440 |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Semi-Automatic |
| Primary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Secondary Desorption Temp Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment, >3000 °C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40 °C (±1 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Sample Capacity | 1 tube per run |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, visual indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Tube Materials | Stainless steel, quartz glass, fused silica capillary (optional) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 470×500×380 mm |
| Weight | ~35 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Equipment Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–16 L/min |
| Output Pressure | 0.1–0.4 MPa (adjustable), Max Burst Pressure >1.0 MPa |
| Nitrogen Purity | 99.0–99.99% (user-adjustable) |
| Dew Point | –40 °C to +5 °C (typical post-dryer output) |
| Power Supply | 220 V ±10%, 50 Hz |
| Rated Power | 900 W |
| Noise Level | <55 dB(A) |
| Dimensions (W×D×H) | 620 × 510 × 820 mm |
| Weight | 105 kg |
| Operating Ambient Temperature | 5–45 °C |
| Compliance | CE-marked design principles |
| compatible with ISO 8573-1 | 2010 Class 2 compressed air feed requirements |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGN-30LB High-Pressure Nitrogen Generator |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 0–30 L/min |
| Output Pressure | 110 psi (0.76 MPa) |
| Nitrogen Purity | 95%–99.9% |
| Dew Point | ≤ −45 °C |
| Particulate Filtration | < 0.01 µm |
| Total Power Consumption | 1100 W |
| Noise Level | ≤ 60 dB(A) |
| Dimensions (L×W×H) | 800 × 500 × 700 mm |
| Weight | 120 kg |
| Operating Ambient | 220 V ±10%, 50 Hz |
| Relative Humidity | ≤ 80% |
| Ambient Temperature | ≤ 45 °C |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | CAAM-2001C |
| Detection Elements | Na, K, Mg, Ca, Cr, Mn, Fe, Co, Ni, Pt, Au, Cu, Ag, Zn, Cd, Pb, Bi, Li |
| Detection Limit | 0.002 µg/mL (for Cu) |
| Atomizer Temperature Control Range | +15 °C to +35 °C |
| Grating | 1800 lines/mm |
| Wavelength Range | 190–900 nm |
| Spectral Bandwidth | 0.1, 0.2, 0.4, 1.0, 2.0 nm (auto-selectable) |
| Wavelength Accuracy | ±0.15 nm |
| Baseline Drift (static) | ≤±0.002 A/30 min |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ABB Mobile Guard |
| Price Range | USD 560,000 – 630,000 |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-50 |
| Sample Capacity | 50 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Rate | >2000 °C/min |
| Water Trap Desorption Range | Ambient to 150 °C |
| Transfer Line Temperature | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–100 mL/min |
| Trap Materials | Stainless steel / quartz / fused silica capillary (configurable) |
| Programmable External Events | 15 |
| Timing Resolution | 0.1–99 min (accuracy <0.1%) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 580 × 640 × 850 mm |
| Weight | ~50 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S-II |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to –40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy, 1°C increment) |
| Sample Capacity | 40 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (system-dependent, GC and operator performance included) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | ADHS-8890B |
| Instrument Type | Water & Soil Integrated Purge-and-Trap System |
| Sample Tray Capacity | 20 positions |
| Injection Precision | RSD < 10% |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Vial Cooling Range | 4–10 °C |
| Cold Trap (Desorption) Range | Ambient to –40 °C |
| Water Removal Trap Range | Ambient to –30 °C |
| Desorption Ramp Rate | >250 °C/min (low-voltage safe design) |
| Transfer Line & Valve Block Temp | Ambient to 250 °C |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Trap Tube Materials | Stainless steel / Quartz / Fused silica capillary (customizable) |
| Adsorbent Options | Custom-fill available |
| Programmable External Events | 7 channels |
| Timing Resolution | 0.1–99 min (timing accuracy <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa |
| System Pressure Rating | >0.4 MPa |
| Analytical Repeatability (GC-coupled) | RSD < 2.5% |
| Power Consumption | <1000 VA |
| Trigger Signal Latency | <2 s |
| Dimensions (H×W×D) | 500 × 400 × 650 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3440S |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment |
| Secondary Desorption Temp Range | Ambient to 380°C, ±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate |
| Cold Trap Temp Range | Ambient to –40°C (ambient-dependent), ±1°C accuracy, 1°C increment |
| Valve & Transfer Line Temp Range | Ambient to 260°C, ±1°C accuracy, 1°C increment |
| Sample Capacity | 30 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 470 × 490 × 450 mm |
| Weight | ~40 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGH-500 Hydrogen Generator |
| Hydrogen Generation Principle | Pure Water Electrolysis |
| Output Flow Rate | 0–500 mL/min |
| Output Pressure | 0.4 MPa |
| Hydrogen Purity | ≥99.999% |
| Power Consumption | 150 W |
| Input Voltage | 220 V ±10%, 50 Hz |
| Operating Temperature | 0–40 °C |
| Relative Humidity | <85% |
| Dimensions (L×W×H) | 370 × 180 × 360 mm |
| Weight | ~12 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGA-2LB / PGA-5LB |
| Output Flow | 0–2 L/min (PGA-2LB) / 0–5 L/min (PGA-5LB) |
| Output Pressure | 0.4 MPa |
| Power Consumption | 145 W / 175 W |
| Noise Level | ≤42 dB(A) |
| Dimensions (L×W×H) | 500 × 260 × 380 mm |
| Weight | ~25 kg / ~28 kg |
| Air Purity | Oil-free, Triple-stage Purification |
| Cooling | Semiconductor-based Cold-drying System |
| Safety Features | Overpressure Protection, Thermal Cut-off, Low-pressure Soft-start, Automatic Drain Valve |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AFS-100 |
| Detection Elements | As, Se, Pb, Bi, Sb, Te, Sn, Hg, Cd, Ge, Zn, Au |
| Linear Range | Dual-channel ≥ 0.999 |
| Detection Limit | Dual-channel ≤ 0.03 ng/mL |
| Atomizer Temperature Control Range | 15–30 °C |
| Operating Ambient Temperature | 15–30 °C |
| Relative Humidity | ≤75% |
| Argon Supply Pressure | 0.2–0.3 MPa (regulated to 0.2 MPa) |
| Alarm Threshold | <0.15 MPa |
| Power Supply | 220 V ± 22 V AC |
| Host Power Consumption | ≤400 W |
| Warm-up Time | 30 min |
| Repeatability | Dual-channel ≤1% |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-6890S |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Capacity | 9 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 350 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C (1 °C increment) |
| Temperature Accuracy | < ±0.5 °C |
| Pressure Control Range | 0–0.2 MPa (up to 0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Dimensions | 260 × 360 × 420 mm |
| Weight | ~15 kg |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Brand | Huayisanpu (Beijing Huayisanpu Instrument Co., Ltd.) |
|---|---|
| Origin | Beijing, China |
| Model | PGN-30L |
| Output Flow | 30 L/min |
| Output Pressure Range | 0.1–0.4 MPa |
| Nitrogen Purity | 99–99.9% |
| Dew Point | < −60 °C |
| Feed Gas | Oil-free Compressed Air |
| Power Supply | 220 V AC ±10%, 50 Hz, 1100 W |
| Dimensions | 600 × 700 × 1100 mm |
| Weight | 120 kg |
| Compliance | Designed for GLP-compliant lab environments |
| compatible with ISO 8573-1 Class 2 | 2:2 compressed air input |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | 320B / 520B |
| Output Flow Rate | 0–300 mL/min (320B) / 0–500 mL/min (520B) |
| Output Pressure | 0.4 MPa |
| Hydrogen Purity | 99.999% |
| Power Consumption | 150 W (320B) / 180 W (520B) |
| Dimensions (L×W×H) | 370 × 220 × 360 mm |
| Input Voltage | 220 V ±10%, 50 Hz |
| Water Requirement | Deionized or Distilled Water |
| Cooling Method | Semiconductor-based Cooling |
| Moisture Removal | Stacked Tubular Condensation System |
| Maintenance Mode | Auto-refill, Non-backflow Electrolyte Design |
| Compliance | Designed for ISO/IEC 17025-compliant lab environments |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ADHS-8890A |
| Sample Capacity | 20 positions |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Vial Heating Range | Ambient to 250 °C |
| Chilled Vial Temperature Range | 4–10 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Water Removal Trap Range | Ambient to −30 °C |
| Desorption Ramp Rate | >250 °C/min |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Purge Flow Rate | 0–500 mL/min |
| Tubing & Line Heating Range | Ambient to 250 °C |
| Power Consumption | <1000 VA |
| Dimensions (H×W×D) | 500×400×650 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-4133 |
| Automation Level | Fully Automated |
| Primary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment) |
| Secondary Desorption Temp Range | Ambient to 380°C (±0.5°C accuracy, 1°C increment, >3000°C/min ramp rate) |
| Cold Trap Temp Range | Ambient to −40°C (±1°C accuracy, 1°C increment) |
| Valve & Transfer Line Temp Range | Ambient to 260°C (±1°C accuracy) |
| Sample Pathway Temp Range | Ambient to 200°C (±1°C accuracy) |
| Sample Capacity | 50 tubes |
| Desorption Recovery | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| RSD | <2.5% |
| Tube Material | Stainless steel |
| Trap Options | Stainless steel, quartz glass, or fused silica capillary |
| Carrier Gas Flow | 0–100 mL/min (adjustable with flow indicator) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| External Event Control | 15 programmable events |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Power Consumption | <1000 VA |
| GC Trigger Latency | <2 s |
| Dimensions (H×W×D) | 500 × 485 × 650 mm |
| Weight | ~45 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-51 |
| Instrument Type | Dual-stage thermal desorber |
| Automation Level | Fully automated |
| Primary Desorption Temperature Range | 50–380 °C |
| Secondary Desorption Temperature Range | 150–380 °C |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | Ambient to −40 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Peak Width (FWHM) | < 3 s |
| Desorption Efficiency | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Sample Capacity | 51 positions |
| Compliance | Designed for ASTM D6196, ISO 16017-1, USP <621>, and EPA TO-17 workflows |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-8890 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (customizable: 10 mL, 50 mL) |
| Oven Temperature Range | Ambient to 200 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 180 °C / Ambient to 150 °C (1 °C increment) |
| Temperature Control Accuracy | < ±0.5 °C |
| Temperature Uniformity (Gradient) | < ±0.5 °C |
| Pressurization Range | 0–0.2 MPa (0–0.7 MPa optional) |
| Pressure Monitoring | Digital display, 0–0.2 MPa |
| RSD for Repeatability | < 1% (GC-dependent) |
| Power Supply | AC 220 V ±10%, 50 Hz ±0.5 Hz |
| Operating Environment | 10–40 °C, RH < 85% |
| Dimensions (W×D×H) | 570 × 330 × 265 mm |
| Weight | ~25 kg |
| Brand | Beijing Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGT-300/500 Integrated N₂–H₂–Air Generator |
| Nitrogen Purity | 99.994% (O₂ ≤ 60 ppm) |
| Hydrogen Purity | 99.999% (O₂ + H₂O ≤ 1 ppm) |
| Air Purity | Oil-free, Class 3 per ISO 8573-1 |
| Nitrogen Flow Rate | 0–300 mL/min (PGT-300) / 0–500 mL/min (PGT-500) |
| Hydrogen Flow Rate | 0–300 mL/min (PGT-300) / 0–500 mL/min (PGT-500) |
| Air Flow Rate | 0–2 L/min (PGT-300) / 0–5 L/min (PGT-500) |
| Output Pressure | 0.4 MPa (adjustable, stability ≤ ±0.01 MPa) |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 350 W (PGT-300) / 450 W (PGT-500) |
| Dimensions (L×W×H) | 505 × 400 × 460 mm |
| Weight | 40 kg (PGT-300) / 42 kg (PGT-500) |
| Operating Environment | 0–45 °C, RH < 85%, non-corrosive, low-dust |
| Water Requirement | Deionized or distilled water only |
| Design | Integrated monolithic chassis with independent gas modules and shared control logic |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | ATDS-3430S |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve Temperature Range | Ambient to 260 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 260 °C (±1 °C) |
| Cold Trap Temperature | Ambient |
| Temperature Stability | < ±1 °C |
| Desorption Recovery Rate | >98% (toluene, 0.1 µL, 10:1 split ratio) |
| Peak Width (FWHM) | <3 s |
| Sample Capacity | 30 tubes |
| Programmable Events | Up to 15 |
| Event Timing Range | 0.1–99 min (<0.1% timing error) |
| Carrier Gas Flow | 0–100 mL/min (adjustable, digital indication) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| RSD | <2.5% (GC-dependent) |
| Power Consumption | <1000 VA |
| Trigger Signal Output Delay | <2 s |
| Dimensions (H×W×D) | 470×490×450 mm |
| Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | AHS-50 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 50 positions |
| Vial Size Compatibility | 10 mL and 20 mL standard crimp-top vials |
| Oven Temperature Range | Ambient to 380 °C (±0.5 °C accuracy, 1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 260 °C (±1 °C accuracy, 1 °C increment) |
| Quantitative Loop Volume | 1 mL |
| External Event Control Channels | 15 |
| Timing Resolution | 0.1–99 minutes (timing error <0.1%) |
| Pneumatic Actuation Pressure | <0.4 MPa (adjustable) |
| System Pressure Rating | >0.4 MPa |
| Heated Incubation Zones | 4 independent zones |
| Repeatability | RSD <1% (dependent on GC system performance and operator technique) |
| Power Requirement | <1000 VA |
| Trigger Signal Output Latency | <2 s |
| Dimensions (H×W×D) | 580 × 564 × 666 mm |
| Net Weight | ~40 kg |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PGN-300 |
| Nitrogen Generation Principle | Electrolytic Membrane Separation |
| Output Flow Rate | 0–300 mL/min |
| Output Pressure | 0.4 MPa |
| Nitrogen Purity | 99.999% |
| Dew Point | −10 to −40 °C |
| Input Air Pressure | 0.5 MPa |
| Power Supply | 220 V AC, 50 Hz |
| Max. Power Consumption | 80 W |
| Dimensions (L×W×H) | 385 × 180 × 360 mm |
| Net Weight | ~14 kg |
| Operating Ambient | 10–40 °C, RH < 85%, non-corrosive, low-dust environment |