BrandJWGB
OriginUSA
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelDSC 600
Sample CapacitySingle-sample
Instrument TypeDifferential Scanning Calorimeter
Temperature Range−150 °C to 600 °C
Temperature Accuracy±0.1 °C
Heating/Cooling Rate0.1–200 °C/min
Temperature Precision±0.1 °C
Added to wishlistRemoved from wishlist 0
Add to compare
Temperature Range–125 to 1500 °C
Heating Rate0.1–40 °C/min
Max Sample Mass0.4 g
Balance Resolution0.1 µg
Furnace Options650 °C / 1200 °C / 1500 °C
DSC/DTA ModeYes
Gas ControlDual- or Quad-channel purge system
SoftwareInfinity Pro Thermal Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelTGA 1000
Temperature RangeRT–1000°C
Balance Sensitivity0.1 µg
Heating/Cooling Rate0.1–300 K/min
Maximum Sample Mass0.4 g
Sample CapacitySingle
EnvironmentHigh-Temperature/Controlled-Atmosphere
ConstructionStainless Steel Gas Pathway
CoolingWater-Cooled Furnace
Software PlatformInfinity Pro for Windows
ComplianceASTM E1131, ISO 11358, USP <691>, GLP-Ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelSTA 650
Temperature Range–125 to 650 °C
Heating Rate0.1–100 °C/min
Maximum Sample Mass400 mg
Balance Resolution0.1 µg
SoftwareInfinity Pro Thermal Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelTMA 800
Temperature Range-90°C to 800°C
Temperature Accuracy±1°C
Temperature Precision±1°C
Cooling OptionsMechanical refrigeration, water cooling
Test ModesExpansion, Compression, Tension, Penetration, 3-Point Bending
Maximum Load Force2 N
Displacement SensorHigh-sensitivity LVDT
Furnace DesignAll-metal, vertical inline architecture with Archimedes suspension system
Sample Height RangeMicrometer-scale to >10 mm
Uniform Temperature Zone Height40 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandISI
OriginUSA
ModelTGA 1500
Temperature RangeRT–1000 °C
Balance Sensitivity0.1 μg
Heating/Cooling Rate0.1–300 K/min
Maximum Sample Mass0.4 g
Sample CapacitySingle
EnvironmentHigh-Temperature/Controlled-Atmosphere
ConstructionStainless-Steel Dual-Gas Purge System
Software PlatformInfinity Pro for Windows
Optional ModulesEGA Interface with Heated Transfer Line, Auto Gas Switching, Step ISO Compliance Mode, Water-Cooled Furnace
Added to wishlistRemoved from wishlist 0
Add to compare
Temperature Range-125–1200°C
Heating Rate0.1–40°C/min
Max Sample Mass0.4 g
Balance Resolution0.1 µg