Empowering Scientific Discovery

Beijing Yuweitang Technology Development Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGerber
OriginGermany
ModelSUPER-VARIO-N
Max Speed1130 rpm
Speed Adjustment10 rpm increments (600–1130 rpm)
Heating RangeAmbient to 68 °C (1 °C increments)
Timer Range1–99 min
Chamber MaterialStainless Steel
Safety FeaturesAutomatic lid lock and brake system
Sample Capacity12 positions for Mojonnier and solubility methods
ComplianceDesigned for ASTM D129, ISO 1735, IDF 14, and AOAC 923.04 dairy fat determination protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGERBER
OriginSwitzerland
ModelUniversal
Speed Range200–1100 rpm (fixed 1300 rpm option available)
Temperature ControlUp to 65 °C (heating only)
Timer Range0–255 minutes
Sample Capacity12 positions for Mohr and solubility methods
Method SelectionGerber, Mohr, Babcock, and solubility methods
Safety FeaturesAutomatic lid lock, electronic braking, imbalance detection and auto-shutdown
ComplianceDesigned for routine dairy and food quality control per ISO 8570, IDF 128, AOAC 920.132, and FDA Grade A standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGERBER
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNOVA-SAFETY
Speed1350 rpm
Relative Centrifugal Acceleration (RCF)350 × g
Heating Temperature Control65 °C ± 1 °C
Capacity8 tubes (10–12 mL Gerber-specific centrifuge tubes)
Safety LockAutomatic lid interlock with force-sensing engagement
Brake Time< 8 s after rotor stop command
TimerDigital, adjustable 0–30 min in 1-sec increments
ComplianceDesigned to meet ASTM D943, ISO 1735, and IDF Standard 102 for Gerber fat determination
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGERBER
OriginGermany
ModelSuper-Vario-N
Max Speed1130 rpm
Speed Adjustment10 rpm increments (600–1130 rpm)
Heating RangeAmbient to 68 °C (1 °C increments)
Timer Range1–99 min
Chamber MaterialStainless steel
Safety FeaturesAutomatic lid lock and brake system
Sample Capacity12 samples per run (Schmidt-Lewandowsky / solubility method)
ComplianceDesigned for Gerber, Mojonnier, Babcock, and solubility fat determination methods
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGERBER
OriginGermany
ModelNova Safety
Max Speed1350 rpm
Relative Centrifugal Acceleration (RCF)350 × g
Capacity8 tubes
Temperature Control65 °C (heated)
TimerDigital display
Safety FeaturesAutomatic lid lock, electronic brake (<8 s stop time)
Dimensions (L×W×H)470 × 380 × 230 mm
Weight13.2 kg
Voltage230 V, 50 Hz
Power450 W
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0