- All
- Favorite
- Popular
- Most rated
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SUPER-VARIO-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless Steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 positions for Mojonnier and solubility methods |
| Compliance | Designed for ASTM D129, ISO 1735, IDF 14, and AOAC 923.04 dairy fat determination protocols |
| Brand | GERBER |
|---|---|
| Origin | Switzerland |
| Model | Universal |
| Speed Range | 200–1100 rpm (fixed 1300 rpm option available) |
| Temperature Control | Up to 65 °C (heating only) |
| Timer Range | 0–255 minutes |
| Sample Capacity | 12 positions for Mohr and solubility methods |
| Method Selection | Gerber, Mohr, Babcock, and solubility methods |
| Safety Features | Automatic lid lock, electronic braking, imbalance detection and auto-shutdown |
| Compliance | Designed for routine dairy and food quality control per ISO 8570, IDF 128, AOAC 920.132, and FDA Grade A standards |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA-SAFETY |
| Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Heating Temperature Control | 65 °C ± 1 °C |
| Capacity | 8 tubes (10–12 mL Gerber-specific centrifuge tubes) |
| Safety Lock | Automatic lid interlock with force-sensing engagement |
| Brake Time | < 8 s after rotor stop command |
| Timer | Digital, adjustable 0–30 min in 1-sec increments |
| Compliance | Designed to meet ASTM D943, ISO 1735, and IDF Standard 102 for Gerber fat determination |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Super-Vario-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 samples per run (Schmidt-Lewandowsky / solubility method) |
| Compliance | Designed for Gerber, Mojonnier, Babcock, and solubility fat determination methods |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Nova Safety |
| Max Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Capacity | 8 tubes |
| Temperature Control | 65 °C (heated) |
| Timer | Digital display |
| Safety Features | Automatic lid lock, electronic brake (<8 s stop time) |
| Dimensions (L×W×H) | 470 × 380 × 230 mm |
| Weight | 13.2 kg |
| Voltage | 230 V, 50 Hz |
| Power | 450 W |
Show next