| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Solution Index Mixer |
| Motor Speed | 2800 rpm (drive), 3600 rpm (impeller) |
| Impeller | 16-blade stainless steel, clockwise rotation, flat side down, upward tilt from right to left |
| Vessel | 500 mL borosilicate glass beaker |
| Standards Compliance | ADPI, DLG, DIN ISO 8156 |
| Dimensions | 38 × 26 × 25 cm |
| Power | 65 W (220 V, 50 Hz) |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice-point curve, ice-point value, water adulteration percentage, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, two USB ports (U-disk data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | Yueweitang |
|---|---|
| Model | RS-2A |
| Origin | Beijing, China |
| Type | Industrial Non-Destructive Integrity Tester for Aseptic Beverage Packaging |
| Detection Principle | Inertial Kinetic Energy Measurement |
| Max Throughput | 700–800 packages/hour |
| Accuracy (Standard Deviation) | ≤0.0030 |
| Resolution | 0.0001 |
| Recognition Rate | >99% for Coagulated, Gas-Swollen, and Severely Acidified Packages |
| Sample Compatibility | Tetra Brick®, Tetra Pillow® cartons (standard), with interchangeable trays for multiple package formats |
| Compliance | Designed for GLP-aligned food quality control environments |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SUPER-VARIO-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless Steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 positions for Mojonnier and solubility methods |
| Compliance | Designed for ASTM D129, ISO 1735, IDF 14, and AOAC 923.04 dairy fat determination protocols |
| Brand | GERBER |
|---|---|
| Origin | Switzerland |
| Model | Universal |
| Speed Range | 200–1100 rpm (fixed 1300 rpm option available) |
| Temperature Control | Up to 65 °C (heating only) |
| Timer Range | 0–255 minutes |
| Sample Capacity | 12 positions for Mohr and solubility methods |
| Method Selection | Gerber, Mohr, Babcock, and solubility methods |
| Safety Features | Automatic lid lock, electronic braking, imbalance detection and auto-shutdown |
| Compliance | Designed for routine dairy and food quality control per ISO 8570, IDF 128, AOAC 920.132, and FDA Grade A standards |
| Brand | Yueweitang |
|---|---|
| Model | MASTER |
| Origin | Imported |
| Detection Parameters | Fat (0.00–20.00%), Protein (2.00–7.00%), Lactose (0.00–6.00%), Non-Fat Solids (3.00–15.00%), Ash (0.4–1.5%), Water Adulteration (1–70%), Freezing Point (–0.3 to –0.7 °C), Density (1.015–1.040 g/cm³), pH (0–14), Sample Temperature (7–35 °C) |
| Repeatability | Fat ±0.08%, Protein ±0.1%, Lactose ±0.1%, Non-Fat Solids ±0.1%, Ash ±0.05%, Water Adulteration ±1%, Freezing Point ±0.001 °C, Density ±0.0003 g/cm³, pH ±0.05 |
| Throughput | 45–60 samples/hour |
| Sample Volume | 25 mL |
| Power Supply | 110/220 V AC, 50–60 Hz |
| Dimensions (W×D×H) | 125 mm × 260 mm × 205 mm |
| Weight | 3.1 kg |
| Operating Environment | 7–35 °C, 30–80% RH |
| Interface | RS232 |
| Compliance | Designed for routine dairy QC in accordance with ISO 9622, IDF 141, and AOAC Official Methods |
| Brand | Lactoscan (Bulgaria) |
|---|---|
| Origin | Bulgaria |
| Model | MCCW-V1 |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–45%, Protein 2–15%, Lactose 0.01–20%, Ash 0.4–1.5%, Non-Fat Solids 3–40%, Water Adulteration 0–70%, Freezing Point –0.4 to –4.0 °C |
| Repeatability | Fat ±0.06%, Protein ±0.15%, Lactose ±0.2%, Non-Fat Solids ±0.15%, Ash ±0.01%, Water Adulteration ±3%, Freezing Point ±0.005 °C, Sample Temperature ±1 °C, Density ±0.3 kg/m³, pH ±0.05, Conductivity ±0.05% |
| Accuracy | 0.01% |
| Input Voltage | 100–240 V AC, 50–60 Hz |
| Dimensions | 230 × 350 × 350 mm |
| Weight | 8.0 kg |
| Sample Volume | 15 mL |
| Operating Environment | 10–40 °C, 30–80% RH |
| Sample Types | Raw cow milk, sheep milk, UHT milk |
| Brand | Lactoscan (Milkotronic, Bulgaria) |
|---|---|
| Origin | Bulgaria |
| Model | LACTOSCAN S |
| Automation | Fully Automatic |
| Analysis Speed | ≥60 samples/hour |
| Measurement Range | Fat 0.01–25%, Protein 2–7%, Lactose 0.01–6%, Non-Fat Solids 3–15%, Ash 0.4–1.5%, Water Adulteration 0–70%, Freezing Point –0.4 to –0.7 °C, Sample Temperature 1–40 °C, Density 1.000–1.160 g/cm³, pH 0–14, Conductivity 3–10 mS/cm |
| Repeatability | Fat ±0.10%, Protein ±0.15%, Lactose ±0.20%, Non-Fat Solids ±0.15%, Ash ±0.05%, Water Adulteration ±3%, Freezing Point ±0.001 °C, Sample Temperature ±1 °C, Density ±0.0003 g/cm³, pH ±0.05, Conductivity ±0.05 mS/cm |
| Precision | 0.01% |
| Sample Volume | 15 mL |
| Power Supply | 230 V AC, 50–60 Hz / 12 V DC |
| Dimensions | 10 × 24 × 22 cm (W × H × D) |
| Weight | 3.0 kg |
| Compliance | CE-marked, compliant with ISO 9001 manufacturing standards and applicable EU food safety directives |
| Brand | Lactoscan (Bulgaria) |
|---|---|
| Origin | Bulgaria |
| Model | LactoScan MCCW-V1 |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–45%, Protein 2–15%, Lactose 0.01–20%, Non-Fat Solids 3–40%, Ash 0.4–1.5%, Water Adulteration 0–70%, Freezing Point –0.4 to –0.7 °C, Sample Temperature 1–40 °C, Density 1000–1160 kg/m³, pH 0–14, Conductivity 2–14 mS/cm |
| Repeatability | Fat ±0.06%, Protein ±0.15%, Lactose ±0.2%, Non-Fat Solids ±0.15%, Ash ±0.01%, Water Adulteration ±3%, Freezing Point ±0.005 °C, Sample Temperature ±1 °C, Density ±0.3 kg/m³, pH ±0.05, Conductivity ±0.05 mS/cm |
| Accuracy | 0.01% |
| Power Input | 100–240 V AC, 50–60 Hz, 1.6 A |
| Dimensions | 230 × 350 × 350 mm |
| Weight | 8.0 kg |
| Sample Volume | 15 mL |
| Compatible Samples | Raw Cow Milk, Sheep Milk, UHT Milk |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoStar |
| Automation | Fully Automatic |
| Analysis Speed | ≥40 samples/hour |
| Measurement Range | Fat 0–35%, Protein 0–10%, Lactose 0–10%, Non-Fat Solids 0–15%, Minerals 0–5%, Freezing Point Depression –0.001 °C |
| Repeatability | ±0.002% (w/w) |
| Accuracy | ±0.001% (w/w) |
| Sample Volume | 12 mL |
| Calibration Storage | Up to 20 user-defined calibration profiles |
| Interface | RS-232 serial port |
| Data Output | Integrated thermal printer support |
| Brand | Gerber |
|---|---|
| Origin | Switzerland |
| Model | Cryoscope C1 |
| Measurement Range | 0 to −1000 m°C/m°H |
| Display Resolution | 0.1 m°C/m°H |
| Repeatability | ±2 m°C/m°H (1S.D.) |
| Sample Volume | 2.0–2.5 mL |
| Measurement Time | ~90 s (Rapid Mode: ~30 s) |
| Operating Ambient Temperature | 15–35 °C |
| Relative Humidity | 5–80 % RH |
| Power Supply | 110–240 V, 50/60 Hz |
| Power Consumption | 90 W |
| Dimensions (W×D×H) | 28 × 42 × 32 cm |
| Net Weight | 11 kg |
| Gross Weight | 15 kg |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | TDT |
| Standards Compliance | DIN ISO 8967, ISO 3953, ISO 8460, ISO 9161, ISO 787-11, ASTM D4164, ASTM D4781, ASTM B527, USP <616> Method I, IDF 134 |
| Predefined Programs | 5 |
| Tap Count Range | 5–9995 cycles |
| Tap Rate | 250 taps/min |
| Tap Amplitude | 3 mm |
| Included Accessory | 250 mL calibrated graduated cylinder |
| Category | Food Quality Detector for Powder Bulk Density and Tap Density Measurement |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | LactoFlash |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–30.00% |
| Density | ≥0.0001 g/cm³ resolution |
| Freezing Point Depression | ±0.001 °C resolution |
| Repeatability | ±0.02–±0.2% depending on analyte and concentration range |
| Accuracy | ±0.01% for fat, protein, lactose, and non-fat solids |
| Sample Volume | 12–20 mL (adjustable) |
| Power Supply | 230 V / 115 V, 50/60 Hz, 60 W |
| Dimensions | 30 × 24 × 33 cm (W×H×D) |
| Weight | 5 kg |
| Interface | RS-232 serial port |
| Compliance | Designed to support ISO 9001-aligned QA workflows and routine GLP-compliant dairy testing |
| Brand | LACTOSCAN |
|---|---|
| Origin | Bulgaria |
| Model | LactoScan MCC |
| Automation | Fully Automatic |
| Analysis Speed | 120 samples/hour |
| Measurement Range | Fat 0.01–45% |
| Repeatability | Fat ±0.06%, Protein ±0.15%, Lactose ±0.2%, Non-Fat Solids ±0.15%, Ash ±0.01%, Adulteration ±3%, Freezing Point ±0.005 °C, Sample Temperature ±1 °C, Density ±0.3 kg/m³, pH ±0.05, Conductivity ±0.05 mS/cm |
| Resolution | 0.01% |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | FermentoFlash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory Use |
| Analysis Time | ≤2 min (including sample loading) |
| Alcohol Content Range | 0.00–15.00 % v/v |
| Apparent Extract Range | 0.00–10.00 % w/w |
| Original Wort Range | 0.00–20.00 % w/w |
| Alcohol Extraction Range | 0.00–10.00 % w/w |
| Repeatability (Alcohol) | ±0.02 % v/v |
| Repeatability (Extract & Original Wort) | ±0.04 % w/w |
| Dimensions (W × H × D) | 30 × 24 × 33 cm |
| Weight | 5 kg |
| pH Measurement | Not applicable — device does not measure pH (parameter misattributed in source |
| Brand | Weissmann |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WSL-2 |
| Pricing | Available Upon Request |
| Red Scale | R0.1–R79.9 Lovibond Units |
| Yellow Scale | Y0.1–Y79.9 Lovibond Units |
| Blue Scale | B0.1–B49.9 Lovibond Units |
| Neutral (Grey) Scale | N0.1–N3.9 Lovibond Units |
| Minimum Resolution | 0.1 Lovibond Unit |
| Net Weight | 12.5 kg |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | SEDILAB-E |
| Application | Milk and Dairy Product Sediment Analysis |
| Automation Level | Fully Automatic |
| Sample Throughput | 800 samples/hour |
| Sample Volume per Test | 500 mL |
| Sediment Disc Diameter | 32 mm |
| Repeatability | Grade-based Classification (per ISO 707 & IDF 50) |
| Compliance | Designed for ISO, IDF, and national dairy quality standards |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NOVA-SAFETY |
| Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Heating Temperature Control | 65 °C ± 1 °C |
| Capacity | 8 tubes (10–12 mL Gerber-specific centrifuge tubes) |
| Safety Lock | Automatic lid interlock with force-sensing engagement |
| Brake Time | < 8 s after rotor stop command |
| Timer | Digital, adjustable 0–30 min in 1-sec increments |
| Compliance | Designed to meet ASTM D943, ISO 1735, and IDF Standard 102 for Gerber fat determination |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Flash |
| Instrument Type | Beer-Specific Analyzer |
| Application | Laboratory |
| Throughput | 40 samples/hour |
| Alcohol Content Range | 0–15% v/v |
| pH Range | 0–15 |
| Dimensions (W×H×D) | 40 × 20 × 26 cm |
| Weight | 10 kg |
| Sample Volume | 18 mL |
| Measurement Accuracy | ±0.01% for alcohol and extract parameters |
| Interface | RS-232 standard port |
| Data Output | Printer-compatible, PC-integrated |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Super-Vario-N |
| Max Speed | 1130 rpm |
| Speed Adjustment | 10 rpm increments (600–1130 rpm) |
| Heating Range | Ambient to 68 °C (1 °C increments) |
| Timer Range | 1–99 min |
| Chamber Material | Stainless steel |
| Safety Features | Automatic lid lock and brake system |
| Sample Capacity | 12 samples per run (Schmidt-Lewandowsky / solubility method) |
| Compliance | Designed for Gerber, Mojonnier, Babcock, and solubility fat determination methods |
| Brand | Lactoscan |
|---|---|
| Country of Origin | Bulgaria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LACTOSCAN SCC |
| Detection Target | Somatic Cells in Raw Milk |
| Automation Level | Fully Automatic |
| Analysis Time | 20–60 seconds per sample |
| Detection Range | 0–1×10⁷ cells/mL |
| Repeatability | ≤5% CV at 100,000 cells/mL |
| Precision | ±5% at 1×10⁵ cells/mL, ±3% at 4×10⁵ cells/mL, ±2% at 6×10⁵ cells/mL |
| Sample Volume | 12–20 µL (dependent on LACTO chip type) |
| Dimensions | 39 × 30 × 26.5 cm |
| Weight | 7.3 kg |
| Power Supply | 100–240 VAC, 1.6 A, 50/60 Hz |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 0–95% non-condensing |
| Optical System | Four 5 W blue LEDs (475 nm), dual-band excitation/emission filters, high-sensitivity CCD camera |
| USB Ports | 4 |
| Consumables | LACTOSCAN SCC Kit (includes 100 × 4-well chips = 400 tests |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typ. 30/h) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice point curve, ice point value, water adulteration %, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, dual USB ports (U-drive data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.0000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Accuracy | ±0.002 °C (repeatability) |
| Sample Volume | 2.0–2.5 mL |
| Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Cooling Time | ≤15 min to operational temperature |
| Display | Full-color LCD touchscreen |
| Data Interfaces | RS232, 2× USB (U-disk data export) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Nova Safety |
| Max Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Capacity | 8 tubes |
| Temperature Control | 65 °C (heated) |
| Timer | Digital display |
| Safety Features | Automatic lid lock, electronic brake (<8 s stop time) |
| Dimensions (L×W×H) | 470 × 380 × 230 mm |
| Weight | 13.2 kg |
| Voltage | 230 V, 50 Hz |
| Power | 450 W |