- All
- Favorite
- Popular
- Most rated
| Brand | SUPERALD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PEALD E200SP |
| Substrate Size | 200 mm (8 inch) diameter (customizable) |
| Process Temperature Range | Room Temperature to 500 °C (customizable) |
| Precursor Channels | Up to 6 independent precursor lines (solid & liquid sources, customizable) |
| Reactant Gas Lines | 2 (customizable) |
| Carrier Gas | N₂ with MFC flow control (customizable) |
| Plasma Gas Lines | 4 (customizable) |
| RF Power | 0–1000 W |
| Pressure Measurement | Dual corrosion-resistant capacitance manometers (0.005–1000 Torr) |
| Base Vacuum | <5 × 10⁻³ Torr |
| Vacuum System | Standard oil-sealed rotary vane pump |
| Control System | 19-inch industrial touch-enabled HMI, embedded IPC, Windows 7 OS, PLC-based real-time control |
| Source Bottle Heating | RT–200 °C (independent modules) |
| Brand | Micro Materials |
|---|---|
| Origin | United Kingdom |
| Model | Xtreme |
| Instrument Type | Nanoindentation and Scratch Tester |
| Displacement Resolution | 0.002 nm |
| Indenter Types | Diamond, Boron Nitride, Sapphire |
| Thermal Drift | < 0.005 nm/s |
| Vacuum Level | 10⁻⁷ mbar |
| Temperature Range (Vacuum) | −40 °C to 1000 °C |
| Load Frame | Electromagnetic Actuation |
| Load Resolution | 3 nN |
| Repeatability Accuracy | < 0.4 µm |
| Compliance | ISO 14577, ASTM E2546 |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ion-Assisted PLD System |
| Pricing | Upon Request |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Model | M8 |
| Channel Capacity | 8 channels |
| Sensor Diameter | 100 µm |
| Substrate | Optical fiber with customizable polymer coating (standard) |
| Measurement Interval | 250 ms – 10 s (dependent on active channels) |
| OKTA Unit Dimensions | 380 × 265 × 134 mm |
| Optical Unit Dimensions | 250 × 270 × 90 mm |
| Software | Insplorion OKTA Controller |
| OS Compatibility | Microsoft Windows |
| Data Output Format | ASCII-compliant, exportable to MATLAB, Python, Origin, or Excel |
| Sample Interface | Cathode–separator interface (validated for LFP/graphite coin cells) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 420A ILVES |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Insplorion AB |
|---|---|
| Origin | Sweden |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NPS Sensor Chip |
| Pricing | Upon Request |
| Brand | SUPERALD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Thermal-ALD E300S |
| Substrate Size | 300 mm (12 inch) diameter (customizable) |
| Process Temperature Range | RT to 500 °C |
| Temperature Uniformity | ±1 °C (customizable) |
| Precursor Channels | Up to 6 independent, supporting solid & liquid precursors with heated source bottles |
| Reactant Channels | 2 (customizable) |
| Carrier Gas | N₂ with MFC flow control (customizable) |
| Pressure Range | 0.005–1000 Torr (dual corrosion-resistant capacitance manometers) |
| Base Pressure | <5 × 10⁻³ Torr |
| Vacuum System | Standard oil-sealed rotary vane pump |
| Control System | 19-inch industrial touchscreen HMI, embedded IPC running Windows 7, PLC-based real-time logic control with fieldbus support |
| Brand | SUPERALD |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Thermal-ALD E200S |
| Substrate Size | 200 mm (8 inch) diameter (customizable) |
| Process Temperature Range | Room Temperature to 500 °C (customizable) |
| Precursor Channels | Up to 6 independent precursor lines (customizable), supporting both solid and liquid precursors with individual source heating (RT–200 °C) |
| Reactant Gas Lines | 2 (customizable) |
| Carrier Gas | N₂ with Mass Flow Controllers (MFCs) |
| Pressure Monitoring | Dual corrosion-resistant capacitance manometers (0.005–1000 Torr) |
| Base Vacuum | <5×10⁻³ Torr |
| Vacuum System | Standard oil-sealed rotary vane pump |
| Control System | 19-inch industrial touch-enabled display, embedded industrial PC (Windows 7), PLC-based real-time control with fieldbus support |
| Plasma Upgrade Port | Integrated PEALD interface for seamless thermal-to-plasma ALD mode transition without chamber replacement |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | H1 |
| Pricing | Upon Request |
| Detection Limits | Ketamine ≥ 0.1 ng/mL, Morphine ≥ 0.1 ng/mL, Methamphetamine ≥ 0.1 ng/mL, Fentanyl ≥ 0.1 ng/mL |
| Biometric Security | Fingerprint + Iris Recognition |
| Calibration | QR-based Auto-Curve Retrieval & Cloud-Synced Curve Library |
| GNSS | A-GPS / GLONASS / BeiDou |
| Connectivity | 4G LTE, Wi-Fi 802.11a/b/g/n/ac, Bluetooth 4.1, NFC (ID Card & IC Card Read) |
| Display | 5.7″ IPS LCD, 2560×1440 |
| Imaging System | Triple Camera (8 MP + 16 MP + 2 MP) |
| Dimensions | 160 × 82 × 38 mm |
| Weight | 450 g |
| Sample Interface | Auto-Recognizing Lateral Flow Immunoassay (LFIA) Cartridge with Batch ID & Format Detection |
| Supported Drugs | 20 Controlled Substances including Ketamine, Morphine, Methamphetamine, Fentanyl |
| Brand | Lumina |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AT Series (AT1, AT1-Auto, AT2, AT2-EFEM) |
| Pricing | Available Upon Request |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 180 PED |
| Quotation | Upon Request |
| Vacuum Chamber | 18" spherical chamber with 8" CF viewport, 6.75" CF PED source port, three 6" CF ports, two additional 2.75" and 1.33" CF ports |
| Electron Gun Energy | 8–20 keV |
| Pulse Energy | 100–800 mJ |
| Pulse Width | 100 ns |
| Max Repetition Rate | 10 Hz at 15 kV, 5 Hz at 20 kV |
| Beam Cross-Section (Min) | 8 × 10⁻² cm² |
| Peak Power Density | 1.3 × 10⁸ W/cm² |
| Z-Axis Alignment Range | 50 mm |
| XY Alignment Range | ±20 mm |
| Spark Plug Lifetime | ~3 × 10⁷ pulses |
| Substrate Heater | Ø2" max / 10×10 mm² min |
| Substrate Rotation | 1–30 RPM (360° continuous) |
| Target Carousel | 6 × 1" or 3 × 2" targets |
| Target Grid Scanning | Programmable raster ablation pattern |
| Target Height Adjustment | Motorized |
| Target Shutters | Individual shutters per target to prevent cross-contamination |
| Process Gas Compatibility | O₂, N₂, Ar |
| Pulse Energy Stability | ±10% |
| Base Pressure | ≤8 × 10⁻⁸ Torr (with dry pump + turbomolecular pump) |
| Software Platform | Windows 7 + LabVIEW 2013 |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | M1P |
| Pricing | Available Upon Request |
| Laser Wavelength | 785 nm |
| Laser Power | 1–500 mW (adjustable) |
| Laser Energy Accuracy | ±10% |
| Dose Equivalent Rate Range | 0.01–1000 µSv/h |
| Cumulative Dose Range | 0 µSv–100 Sv |
| Spectral Range | 200–1800 cm⁻¹ |
| Spectral Resolution | 8–11 cm⁻¹ |
| Alarm Threshold | 1–1000 µSv/h |
| Detection Time (e.g., ethanol) | <3 s |
| Alarm Latency | 2–4 s |
| Radiation Detection Types | α, β, γ |
| Detector Type | Scintillation Detector |
| Energy Detection Range | 25 keV–3 MeV |
| GPS Support | A-GPS, GLONASS, BeiDou |
| Connectivity | 4G, Wi-Fi, Bluetooth |
| Dimensions | 159 × 78.9 × 27 mm |
| Weight | 445 g |
| Database | Base Library, Expandable Library, User-Customizable Library (real-time sync) |
| Brand | Bionavis |
|---|---|
| Origin | Finland |
| Model | MP-SPR Navi 200 OTSO |
| Sample Volume | 250 µL |
| Injection Volume | 50 µL |
| Analysis Time | 5–10 min |
| Temperature Control Range | 15–45 °C (ambient ±7 °C / +20 °C) |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Pioneer 120 PLD System |
| Substrate Heater Type | Conductive (electrical) heating stage |
| Max Substrate Temperature | 950 °C |
| Heater Compatibility | O₂-compatible up to 1 atm (760 Torr) |
| Target Changer | Motorized, programmable multi-target rotator with rastering and position indexing |
| Vacuum System | Dry-pump stack — turbomolecular pump backed by diaphragm or scroll pump |
| Deposition Chamber Ports | 8" CF for pump, 8" CF for heater, 8" CF for target assembly |
| Laser Source | KrF excimer laser (248 nm) |
| Optical Path | 45° turning mirror, plano-convex lens (f ≈ 50 cm) |
| Control Software | Windows 7 + LabVIEW 2013 (integrated real-time control of heater, target rotation, pressure regulation, pump sequencing, and laser triggering) |
| Compliance | Designed for GLP/GMP-aligned thin-film R&D |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | AURORA |
| Construction | Monolithic Aluminum Extrusion with Integrated NEOcore Phase-Change Thermal Channel |
| Thermal Load Capacity | Up to Multi-kilowatt Passive Dissipation |
| Mounting Flexibility | Horizontal or Vertical Integration |
| Compliance | Designed for ISO 9001–certified manufacturing |
| Certifications | CE-marked for industrial equipment integration |
| Brand | SUPERALD |
|---|---|
| Origin | Guangdong, China |
| Model | Glove Box Integrated |
| Substrate Size | 200 mm (8 inch) diameter (customizable) |
| Process Temperature Range | RT to 500 °C (customizable) |
| Precursor Channels | Up to 6 (solid & liquid sources supported, customizable) |
| Reactant Gas Channels | 2 (customizable) |
| Carrier Gas | N₂ with MFC flow control (customizable) |
| Plasma Gas Channels | 4 (customizable) |
| RF Power | 0–1000 W |
| Pressure Measurement | Dual corrosion-resistant capacitance manometers (0.005–1000 Torr) |
| Base Vacuum | <5×10⁻³ Torr |
| Vacuum Pump | Standard oil-sealed rotary vane pump |
| Control System | 19″ industrial touch display, embedded IPC running Windows 7, PLC-based real-time control with fieldbus support |
| Source Bottle Heater | RT–200 °C |
| Glove Box Integration | Dual-glove, single-station configuration (customizable) |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | COMET |
| Core Technology | NEOcore® Integrated Heat Channel |
| Max Power Handling | 840 W (COMET Matrix configuration) |
| Material | High-Purity Aluminum |
| Working Fluid | Water-based Hydroxide Compound |
| Length Options | 150 mm (standard), custom lengths available |
| Diameter Options | 50 mm or 70 mm |
| Weight | 260 g (150 mm, Ø70 mm) |
| Mounting Angle Tolerance | ±85° |
| Thermal Resistance | 0.12 K/W (natural convection, 12-module COMET Matrix, Ø70 mm) |
| Lightness | 50% weight reduction vs. conventional aluminum heatsinks |
| Tooling | No mold cost — rapid prototyping from standard modules |
| Design Flexibility | Fully modular platform for iterative thermal architecture development |
| Production Scalability | Direct transition from prototype to volume manufacturing |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Model | Aluminum Ion Detector |
| Type | Portable Multi-Ion Analyzer |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed for Field-Deployable Water Quality Monitoring per ISO 10523, ASTM D3590, and EPA Method 200.7 (ICP-OES reference correlation) |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Magma EFI HiRes |
| Pricing | Upon Request |
| Brand | CooliBlade |
|---|---|
| Origin | Finland |
| Model | ULTIMA |
| Heat Sink Material | Aluminum |
| Working Fluid | Hydrocarbon-based Phase-Change Medium |
| Weight | 2.7 kg |
| Mounting Angle | 0° ±5° |
| Thermal Resistance | 0.028 K/W |
| Max Operating Temperature | 150 °C |
| Operating Temperature Range | −20 °C to +150 °C |
| Ambient Temperature Range | −20 °C to +60 °C |
| Storage Temperature Range | −50 °C to +90 °C |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Brand | Neocera |
|---|---|
| Origin | USA |
| Model | Large-Area PLD Systems |
| Substrate Diameter | 4" (100 mm), 6" (150 mm), 8" (200 mm) |
| Chamber Type | 18-inch-diameter spherical or cylindrical vacuum chamber |
| Max. Substrate Temperature | 850 °C (for 4″), 750 °C (for 6″), 700 °C (for 8″) |
| Target Mount | 4 × 2-inch rotary target assembly |
| Thickness Uniformity | ±5% or better across full wafer |
| Process Gases | O₂, N₂, Ar with mass flow controllers (MFCs) |
| Load Lock | Integrated |
| Automation Platform | Windows 7 + LabVIEW 2013 |
| Laser Scanning | Programmable beam rastering with inverse-velocity dwell-time compensation |
| Oxygen-Compatible High-Temperature Operation | Yes |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Model | M1S |
| Laser Wavelength | 785 nm |
| Scan Modes | Lissajous scanning, single-point scanning, customizable area-matrix scanning |
| Laser Power | 1–500 mW (adjustable) |
| Spectral Range | 200–1800 cm⁻¹ |
| Spectral Resolution | 8–11 cm⁻¹ |
| Detection Time | <3 s (e.g., ethanol) |
| Connectivity | 4G, Wi-Fi, Bluetooth, NFC |
| GNSS Support | A-GPS, GLONASS, BeiDou |
| Biometric Authentication | Fingerprint + Iris recognition |
| Security Architecture | MCS cloud-network-terminal isolation framework |
| Dimensions | ~205 × 85 × 27.5 mm |
| Weight | ~500 g |
| Database | Cloud-synchronized base library (auto-updated), expandable library (instant sync), user-defined library |
| Sample Types | Solids, liquids, powders, gels, opaque or dark-colored materials |
Show next