Bioengineering Equipment
Filter
Showing 991–1020 of 1955 results
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Model | CSTHZ-82 |
| Timer Range | 1–120 min |
| Oscillation Frequency | 30–300 rpm (orbital) |
| Oscillation Amplitude | 26 mm |
| Temperature Control Range | RT to 90 °C |
| Temperature Accuracy | ±0.5 °C |
| Ultrasonic Frequency | 40–80 kHz (dual-frequency, adjustable) |
| Ultrasonic Power | 800 W |
| Ultrasonic Timer | up to 9999 min or continuous mode |
| Bath Volume | 52 L (560 × 495 × 190 mm) |
| Tray Dimensions | 420 × 350 mm |
| Cooling Function | Yes |
| Heating Power | 1.8 kW |
| Input Voltage | AC 220 V, 50 Hz |
| Number of Platforms | 1 |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-1600A |
| Price Range | USD 70,000 – 140,000 |
| Channels | 36 (standard), up to 72 or custom-configurable |
| Temperature Range | Ambient to 80 °C |
| Temperature Accuracy | ±0.5 °C |
| Airflow Control Range | 0.01–10 L/min |
| Airflow Accuracy | ±1.0 % FS |
| CO₂ Detection Range | 0–10,000 ppm |
| CO₂ Detection Accuracy | ±40 ppm (0–3,000 ppm), ±2 % (3,000–10,000 ppm) |
| O₂ Detection Range | 0–25 % |
| O₂ Detection Accuracy | ±1 % FS |
| Pressure Range | 0–200 kPa |
| Pressure Accuracy | ±1 % FS |
| Reaction Vessel Volume | 3.5 L per chamber |
| Total Chambers | 18 |
| Power Supply | 220 V AC, 50 Hz, 3000 W |
| Dimensions | 3600 × 810 × 1930 mm |
| Weight | 1100 kg |
| Compliance | GB/T 19277.1–2011, GB/T 19277.2–2013, GB/T 22047–2008, ISO 14855-1:2012, ISO 14855-2:2018, ISO 17556:2012, ASTM D5338, EN 13432, GB/T 20197–2016 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DHG-1600C |
| Price Range | USD 70,000 – 140,000 |
| Channel Capacity | 36 or 72 (customizable) |
| Temperature Range | Ambient to 100 °C (±1 °C accuracy) |
| Humidity Control | Up to 90 % RH |
| Airflow Control | 0.01–100 mL/min |
| Reaction Vessel Volume | 2.3 L (borosilicate glass) |
| CO₂ Quantification Method | NaOH absorption followed by titration or Total Inorganic Carbon (TIC) analysis |
| Power Supply | 220 V AC, 50/60 Hz, 5000 W |
| Weight | 230 kg |
| Compliance Standards | GB/T 19277.1–2011, GB/T 19277.2–2013, GB/T 20197–2016, GB/T 22047–2008, ISO 14855-1:2012, ISO 14855-2:2018, ISO 17556:2012, ASTM D5338, EN 13432 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker |
| Model | DKZ-3 |
| Timing Range | 1–999 min |
| Oscillation Frequency | 40–150 rpm |
| Amplitude | 30 mm (orbital) |
| Temperature Range | RT + 5 °C to 100 °C |
| Temperature Uniformity | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Chamber Material | Stainless Steel (304) |
| Chamber Dimensions (W×D×H) | 618 × 310 × 250 mm |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 1650 W |
| Number of Platforms | 1 |
| Display | Digital LED for temperature and speed |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | FZ-12 |
| Instrument Type | Tumbling Shaker |
| Timer Range | 0–59 h 59 min |
| Rotational Speed Range | 0–60 rpm (no-load) |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Sample Capacity | Compatible with 2 L containers (glass, PE, PTFE, and other chemically resistant vessels) |
| Construction | Stainless steel chamber with electrostatic powder-coated exterior |
| Safety Features | Overload protection circuit |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | HZQ-311C |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0.1 h to 999 h 59 min |
| Oscillation Frequency | 30–250 rpm |
| Orbit Diameter | 20 mm |
| Temperature Range | 4–60 °C |
| Number of Shaking Platforms | 1 |
| Platform Dimensions | 920 × 500 mm |
| Power Input | 1700 W |
| Display | Large Backlit LCD with Menu-Driven Interface |
| Construction | Stainless Steel Interior & Shaking Surface |
| Insulation | CFC-Free Polyurethane Foam |
| Safety Features | Independent Over-Temperature Cut-Off, Door-Interlocked Shutdown, Brushless AC Motor, Programmable Multi-Stage Control (Optional), RS-485/USB Data Export (Optional) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Temperature-Controlled Orbital Shaker |
| Model | KBC-82A |
| Timer Range | 1–999 h |
| Oscillation Speed | 30–300 rpm |
| Orbit Diameter | 30 mm |
| Temperature Range | Ambient to 60 °C |
| Platform Quantity | 1 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | LB-2102 |
| Timer Range | 0–999 h |
| Oscillation Frequency | 40–280 rpm |
| Orbit Diameter | 50 mm |
| Temperature Range | 4–60 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Stability | ±0.5 °C |
| Tray Dimensions | 750 × 500 mm |
| Number of Trays | 2 |
| Max Capacity | 70 × 250 mL or 50 × 500 mL or 24 × 1000 mL |
| Drive Type | Brushless DC Motor |
| Control System | Microprocessor-based with Programmable Multi-Stage Profile (up to 10 segments) |
| Safety Features | Independent Over-Temperature Cut-off, Door Interlock Switch, Motor Overheat Protection, Power-Fail Recovery, Soft-Start Acceleration |
| Optional | Humidity Control Module, USB Data Logging Interface, Stainless Steel Mirror-Finish Interior, Tempered Glass Viewing Window, Inert Gas Inlet Port |
| Brand | Langbo Instruments |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP-8A |
| Instrument Type | Horizontal Oscillating Shaker |
| Timer Range | 1–999 min |
| Oscillation Speed | 0–200 rpm |
| Stroke Amplitude | 40 mm |
| Number of Platforms | 1 |
| Maximum Bottle Capacity | 16 × 2000 mL |
| Power Consumption | 120 W |
| Voltage/Frequency | 220 V / 50 Hz |
| Compliance | HJ 557–2009 (China Environmental Protection Standard for Solid Waste Leaching Toxicity – Horizontal Oscillation Method) |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-20 |
| Type | Inversion Shaker |
| Timer Range | 1–999 h |
| Oscillation Speed | 0–60 rpm |
| Oscillation Amplitude | 180° (inversion motion) |
| Temperature Range | Ambient +5°C to 50°C |
| Shelf Quantity | 1 stainless-steel platform |
| Sample Capacity | Up to six 2 L containers (glass, PE, PTFE, or HDPE) |
| Construction | Stainless steel outer chamber with electrostatic epoxy coating |
| Safety Features | Overload protection circuit |
| Control System | Digital PID temperature controller + microprocessor-based speed regulator |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | TCLB-6A |
| Instrument Type | Inverting Shaker |
| Temperature Range | Ambient +5°C to 60°C |
| Timer Range | 0–999 h |
| Speed Range | 0–45 rpm (no-load), 30 ±2 rpm (loaded, 2 L bottles) |
| Number of Shaking Plates | 2 |
| Chamber Material | Stainless steel housing with electrostatic powder coating |
| internal fixtures | aluminum alloy |
| Safety Features | Overload protection |
| Compatible Vessels | 2 L glass, PE, PTFE, and ZHE containers |
| Compliance | Designed for GLP-compliant laboratory workflows requiring traceable, repeatable sample inversion under controlled thermal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | YY-82A |
| Instrument Type | General-Purpose Temperature-Controlled Orbital Shaker |
| Timer Range | 1–120 min |
| Oscillation Speed | 0–280 rpm |
| Oscillation Amplitude | 20 mm |
| Temperature Range | Ambient +5°C to 300°C |
| Heating Medium | Thermal Oil |
| Temperature Control | Digital PID |
| Temperature Accuracy | ±5°C |
| Chamber Material | Stainless Steel (Interior), Powder-Coated Steel (Exterior) |
| Platform | Single Deck |
| Packaging | Reinforced Wooden Crate |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112 |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 30–280 rpm |
| Amplitude | 30 mm (horizontal circular) |
| Temperature Range | 5–60 °C |
| Shelf Quantity | 2 |
| Tray Dimensions | 800 × 500 mm |
| External Dimensions (per shelf) | 1280 × 770 × 1500 mm |
| Height Occupancy (stacked) | 1930 mm |
| Heating Power | 500 W (per shelf) |
| Cooling Power | 280 W (per shelf) |
| Refrigeration System | Imported compressor with R134a refrigerant |
| Control System | Microprocessor-based LED display with membrane keypad |
| Safety Features | Overheat protection, low-temperature cutoff, leakage current protection, door-open auto-stop, parameter encryption, and real-time alarm prompts for abnormal conditions |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-2112B |
| Instrument Type | Full-Temperature Orbital Shaker |
| Timer Range | 0–500 h |
| Oscillation Frequency | 30–300 rpm |
| Frequency Accuracy | ±1 rpm |
| Orbit Diameter | 25 mm |
| Temperature Control Range | Ambient +5°C to 60°C |
| Temperature Resolution | ±0.1°C |
| Temperature Uniformity | ≤±1°C (at 25°C) |
| Temperature Stability | ≤±0.5°C (at 37°C) |
| Shelf Quantity | 2 |
| Shelf Dimensions | 970 × 560 mm |
| Chamber Volume | 582 L |
| Internal Dimensions | 1095 × 625 × 850 mm |
| External Dimensions | 1200 × 820 × 1600 mm |
| Net Weight | 425 kg |
| Power Consumption | 1150 W |
| Input Voltage | AC 220 V, 50/60 Hz |
| Maximum Load Capacity | 100 mL × 164 |
| Standard Configuration | 250 mL × 45 & 500 mL × 35 |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Model | ZHWY-211C |
| Instrument Type | Full-temperature orbital shaker |
| Timer Range | 999 h |
| Oscillation Frequency | 40–280 rpm |
| Oscillation Amplitude | 26 mm (Φ) |
| Temperature Control Range | 4–60 °C |
| Humidity Control Range | 50–95 %RH |
| Temperature Uniformity | ±1 °C |
| Humidity Uniformity | ±1 %RH |
| Temperature Accuracy | ≤±0.1 °C |
| Humidity Accuracy | ±3 %RH |
| Frequency Accuracy | ±1 rpm |
| Shelving | 1 stainless steel polished platform (970 × 480 mm) |
| External Dimensions (W×D×H) | 1260 × 830 × 1010 mm |
| Net Weight | 230 kg |
| Cooling System | Air-cooled, R134a refrigerant, frost-free operation |
| Humidification | External high-efficiency humidifier |
| Drive Mechanism | Brushless AC motor, constant-torque, wide-speed-range |
| Control Algorithm | PID with environmental scanning microprocessor |
| Display | Backlit LCD with real-time parameter monitoring |
| Interface | RS-232 port for data export |
| Safety Protections | Independent over-temperature cutoff, over-speed cutoff, leakage current protection, circuit breaker, compressor overload protection, low-water-level alarm, sensor fault detection, power-fail recovery, auto-restart after outage |
| Brand | Langbo |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Water Bath Constant-Temperature Shaker / Platform Shaker |
| Timer Range | 1–999 h |
| Oscillation Frequency | 0–280 rpm |
| Oscillation Amplitude | 200 mm |
| Temperature Control Range | Ambient +5°C to 100°C |
| Number of Platforms | 1 |
| Operating Mode | Reciprocating Motion |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | UT 3505 W |
| Temperature Range | −5 °C to 60 °C |
| Temperature Stability | ±0.5 K |
| Cooling/Heating Power | 35 kW |
| IP Rating | IP54 |
| Power Supply | 400 V / 3~ / 50 Hz or 460 V / 3~ / 60 Hz |
| Ambient Operating Range | −15 °C to 50 °C |
| Heat Transfer Fluid | Water or Water/Glycol (non-flammable) |
| Communication Interface | Ethernet with Modbus TCP/IP |
| Display | LCD with plain-text menu navigation |
| Pump Pressure | Digital display |
| Inlet/Outlet Ports | Stainless steel |
| Integrated Components | High-performance pump, stainless-steel heat exchanger, water-cooled condenser, particulate filter, Pt100 sensor input, 4–20 mA analog setpoint interface, digital I/O (ON/OFF, level alarm), optional external solenoid valve support |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 10000 W |
| Temperature Range | -20 °C to 80 °C |
| Temperature Stability | ±0.1 K |
| Temperature Uniformity | ±0.1 K |
| Dimensions | 650 × 670 × 1250 mm |
| Power Consumption | 10 kW @ 20 °C |
| Refrigeration Capacity | up to 10.8 kW |
| Heating Capacity | up to 15.8 kW |
| Fluid Reservoir Volume | 64 L |
| Max. Pump Flow Rate | 37 L/min @ 3.2 bar |
| Interface Options | RS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Module |
| Control System | PID-based electronic controller with programmable logic (150 segments), TFT color display, SmartCool digital cooling management |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 1200 W |
| Temperature Range | -20 °C to 80 °C |
| Temperature Stability | ±0.05 K |
| Dimensions | 450 × 550 × 650 mm |
| Power Consumption | 3.3 kW (max) |
| Heating Power | 2.25 kW (max) |
| Pump Flow Rate | 28 L/min @ 0.9 bar |
| Reservoir Volume | 15 L |
| Cooling Medium | Water or water/glycol mixture (non-flammable) |
| Interface Options | RS-232/485, Profibus, Ethernet-USB, analog I/O, digital contact modules |
| Control System | PID-based electronic controller with TFT display, 150-segment programmable scheduler |
| Compliance | CE, RoHS, conforms to EN 61000-6-2/-6-4 EMI/EMC standards |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 3000 W |
| Temperature Range | -20 °C to 80 °C |
| Temperature Stability | ±0.05 K |
| Dimensions | 550 × 650 × 970 mm |
| Power Consumption | 3.0 kW @ 20 °C |
| Pump Flow Rate | 37 L/min @ 3.2 bar |
| Reservoir Volume | 33 L |
| Cooling Medium | Water or Water/Glycol (non-flammable) |
| Interface Options | RS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Modules |
| Control System | PID-based electronic controller with TFT display, 150-segment programmable scheduler, SmartCool digital cooling management |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 5000 W |
| Temperature Range | −20 °C to +80 °C |
| Temperature Stability | ±0.05 K |
| Dimensions (W×D×H) | 550 mm × 650 mm × 970 mm |
| Power Consumption | 5.0 kW @ 20 °C |
| Pump Flow Rate | up to 37 L/min @ 3.2 bar |
| Reservoir Volume | 33 L |
| Cooling Medium | Water or water/glycol mixture (non-flammable) |
| Interface Options | RS-232/485, Profibus, Ethernet-USB, Analog I/O, Digital Contact Module |
| Control System | PID-based electronic controller with TFT display, 150-segment programmable scheduler |
| Compliance | CE, RoHS, conforms to EN 61000-6-2/-6-4 EMI/EMC standards |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VC 7000 W |
| Temperature Range | −20 °C to 80 °C |
| Temperature Stability | ±0.1 K |
| Dimensions (W×D×H) | 650 × 670 × 1250 mm |
| Power Consumption | 7.0 kW @ 20 °C |
| Pump Flow Rate | 37 L/min @ 3.2 bar |
| Fluid Capacity | 64 L |
| Weight | 122 kg |
| Cooling Medium | Water or Water/Glycol Mixture (non-flammable) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | Varioshake |
| Instrument Type | Water-Bath Temperature-Controlled Orbital Shaker |
| Timer Range | 1 min – 999 h |
| Oscillation Frequency | 20–250 rpm |
| Orbit Diameter | 10–32 mm |
| Temperature Range | 20–70 °C (with water cooling) / 28–70 °C (ambient air operation) |
| Temperature Stability | ±0.2 K |
| Display Resolution | 0.1 °C |
| Control Interface | Membrane Keypad with Symbol-Based UI |
| Safety Features | Door-Interlocked Shutdown (shaking & heating), Visual/Audible Low-Temperature Alarm |
| Communication | RS232 Serial Interface |
| Chamber Construction | Electrogalvanized Steel with Powder-Coated Finish |
| Tray Capacity | 1 standard platform (dual-tray configuration supported for containers ≤180 mm height) |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 15 B |
| Timer Range | 1 min to 99:59 h |
| Oscillation Frequency | 20–300 rpm |
| Amplitude | 30 mm |
| Platform Quantity | 1 |
| Max Load Capacity | 15 kg |
| Platform Dimensions (W × D) | 450 × 450 mm |
| Ambient Temperature Range | 10–50 °C |
| Power Consumption | 0.07 kW |
| Overall Dimensions (W × D × H) | 480 × 487 × 160 mm |
| Weight | 18 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 15 O |
| Timer Range | 1 min – 99:59 h |
| Oscillation Frequency | 20–300 rpm |
| Amplitude | 30 mm |
| Tray Quantity | 1 |
| Operating Ambient Temperature | 10–50 °C |
| Tray Dimensions (W × D) | 330 × 330 mm |
| Max. Load Capacity | 8 kg |
| Power Consumption | 0.07 kW |
| Amplitude (additional spec) | 10 mm |
| Frequency Range (extended spec) | 20–500 rpm |
| Dimensions (W × D × H) | 350 × 355 × 160 mm |
| Weight | 11 kg |
| Power Supply | 230 V, 50/60 Hz |
| Motor | AC motor with overload protection |
| Construction | Anodized aluminum platform, electrogalvanized steel housing with powder coating |
| Control Interface | Dual LCD display, membrane keypad with symbolic icons |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 15 R |
| Timer Range | 1 min to 99:59 h |
| Oscillation Frequency | 2–50 rpm |
| Amplitude | 3° |
| Tray Quantity | 1 |
| Operating Ambient Temperature | 10–50 °C |
| Tray Dimensions (W × D) | 450 × 450 mm |
| Max Load Capacity | 15 kg |
| Power Consumption | 0.09 kW |
| External Dimensions (W × D × H) | 480 × 487 × 160 mm |
| Weight | 17 kg |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 15 T |
| Timer Range | 1 min to 99:59 h |
| Oscillation Frequency | 2–50 rpm |
| Amplitude | 3° |
| Tray Quantity | 1 |
| Tray Dimensions (W × D) | 450 × 450 mm |
| Max Load Capacity | 15 kg |
| Ambient Temperature Range | 10–50 °C |
| Power Consumption | 0.09 kW |
| Net Weight | 19 kg |
| Housing Material | Electrogalvanized Steel with Powder Coating |
| Tray Material | Anodized Aluminum |
| Drive Motor | AC Motor with Overload Protection |
| Speed Control | Digital, Stepless, 0.5 rpm Resolution |
| Interface Option | RS-232 (Optional) |
| Noise Level | Low |
| Design | Compact, Balanced, Maintenance-Free Architecture |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 150 OI |
| Timer Range | 1 min – 999 h |
| Oscillation Frequency | 20–250 rpm |
| Amplitude | 25–30 mm |
| Temperature Range | 28–70 °C (ambient-cooled: 20–70 °C) |
| Number of Shaking Platforms | 4 |
| Internal Volume | 150 L |
| Platform Load Capacity | 20 kg |
| Temperature Stability | ±0.2 °C |
| Power Supply | 230 V, 50/60 Hz |
| Heating Power | 0.5 kW |
| Max. Power Consumption | 0.65 kW |
| Internal Dimensions (W×D×H) | 450 × 450 × 338 mm |
| External Dimensions (W×D×H) | 559 × 687 × 628 mm |
| Construction | Stainless steel interior cabinet, door lining & shaking platform |
| Cooling Coil | Integrated for sub-ambient operation |
| Interface | RS232 serial port |
| Safety | Dual-stage thermal cut-off (electronic PID + mechanical limiter), door-interlocked shutoff of heating & shaking |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 20 OH |
| Timer Range | 1 min – 99.9 h |
| Oscillation Frequency | 1–20 rpm |
| Ambient Temperature Range | 10–40 °C |
| Max. Power Consumption | 0.1 kW |
| Max. Load Capacity | 20 kg |
| Dimensions (W×D×H) | 770 × 700 × 715 mm |
| Weight | 68 kg |
| Construction | Powder-coated, electrogalvanized steel housing |
| Drive | Overload-protected DC motor with dynamic mass balancing |
| Bearing System | Dual-side ball-bearing tilt frame with sliding hub drive |
| Clamp Mechanism | Height-adjustable stainless steel clamps, accommodates vessels up to Ø110 mm × H270 mm |
| Sample Capacity | Up to 12 round or square containers under uniform loading |
| Brand | LAUDA |
|---|---|
| Origin | Germany |
| Model | VS 30 O |
| Timer Range | 1 min – 99.9 h |
| Oscillation Frequency | 20–250 rpm |
| Amplitude | 32 mm |
| Platform Quantity | 1 |
| Operating Ambient Temperature | 10–50 °C |
| Tray Dimensions (W × D) | 676 × 540 mm |
| Max Load Capacity | 30 kg |
| Power Consumption | 0.09 kW |
| External Dimensions (W × D × H) | 705 × 607 × 160 mm |
| Weight | 40 kg |