| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA |
| Product Category | Imported |
| Model | Mobius® |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-700 Series |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 40,000 psi |
| Max Flow Rate | 15.6 L/min |
| Inlet Temperature Range | Up to 75 °C |
| Power Supply | 3-Phase, 380 V, 15–50 HP |
| Air Supply | 50–150 psi, 1 SCFM @ 50 psi, Dew Point: 0–35 °F |
| Dimensions | 74 × 180 × 145 cm |
| Weight | 675–900 kg |
| Chamber Material | Diamond-Embedded Stainless Steel |
| Construction | Fully 316L Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110Y |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure Range | 3,000–23,000 psi |
| Max. Flow Rate | 250–600 mL/min |
| Feed Temperature Range | –25°C to +75°C |
| Minimum Sample Volume | 14 mL |
| Compressed Air Requirement | 57 scfm at 120 psi, 15 hp (11 kW) |
| Dimensions | 28 × 41 × 76 cm |
| Weight | 25 kg |
| Interaction Chamber Material | Diamond or Ceramic |
| Wetted Parts | 300-series Stainless Steel (Chromium-Plated Piston) |
| Integrated Cooling Coil | 17 ft (13 mL volume) |
| Cleaning | CIP-capable (Clean-in-Place) |
| Certification | Explosion-Proof & Portable Design |
| Brand | MICHEM (MechaTech) |
|---|---|
| Origin | United Kingdom |
| Model | Hyscan II |
| Measurement Principle | Quantitative Pressure-Reduction Solidification Method |
| Analysis Time | ≤ 5 min per sample |
| Detection Limit | 0.01 cm³/100 g Al |
| Accuracy | ±<5% RSD |
| Compliance | Designed for GLP/GMP-aligned foundry QA workflows |
| Portability | Benchtop with integrated vacuum system and field-deployable rugged chassis |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110EH |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 30,000 psi (207 MPa) |
| Max Flow Rate | 450 mL/min |
| Inlet Temp. Range | ≤75°C |
| Power Supply | 3-Phase, 380 V, 5 HP (3.7 kW) |
| Fluid Path Volume | 100 mL |
| Compressed Air Requirement | 35–150 psi |
| Dew Point | 0–35°F |
| Minimum Sample Volume | 120 mL |
| Dimensions | 73 × 87 × 148 cm |
| Weight | 205 kg |
| IXC Chamber Material | Synthetic Diamond |
| Regulatory Compliance | CE Certified |
| Cleaning | CIP-Compatible |
| Sterilization | SIP-Capable (Steam or Hot Water) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | iTOXcontrol |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-8000 |
| Price Range | USD $14,000–$70,000 |
| Instrument Type | High-Pressure Cell Disruptor |
| Max Operating Pressure | 1,000–8,000 psi |
| Max Flow Rate | 1,000 mL/min |
| Feed Temperature Limit | 75 °C |
| Compressed Air Requirement | 57 SCFM at 50 psi, dew point −17.7 to 1.6 °C, 15 hp (11 kW) |
| Minimum Sample Volume | 250 mL |
| Dimensions | 58 × 38 × 58 cm |
| Weight | 26.7 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Cleaning | CIP-capable high-pressure fluid path |
| Drive Mechanism | Pneumatic, explosion-proof |
| Sterilization Compliance | Autoclavable and SIP-compatible components |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Configuration | Sterile, Pre-assembled Transwell-Compatible Insert System |
| Membrane Material | Polycarbonate (PCF) or Polyester (PET) |
| Pore Size | 0.4 µm (PCF) or 1.0 µm (PET) |
| Well Count | 24 |
| Format | Integrated Insert + Receiver Plate + Lid |
| Sterility | Certified Sterile, Non-Pyrogenic, DNase/RNase-Free |
| Packaging | Individual Blister Pack or Multi-Pack |
| Compliance | ISO 13485–Certified Manufacturing |
| Intended Use | In vitro cell culture, co-culture, permeability assays, differentiation studies, and barrier function analysis |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MERS00002 |
| Price | USD 3,950 (excl. VAT & shipping) |
| Voltage Range | ±999.0 mV |
| Voltage Resolution | 0.1 mV |
| Resistance Range | 0–10,000 Ω |
| Resistance Resolution | 1 Ω |
| Excitation Current | ±10 µA nominal at 12.5 Hz AC square wave |
| Power Supply | Rechargeable 6 V NiMH 2200 mAh battery |
| Battery Life | 8–10 hrs per full charge |
| Analog Output | 1–10 V (1 mV/Ω scaling) |
| Operating Temperature | 10–38 °C |
| Relative Humidity | 0–90% non-condensing |
| Dimensions | 19 × 11 × 6 cm |
| Weight | 1.4 kg |
| Brand | Millipore |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | NovAseptic® Magnetic Stirrer |
| Pricing | Available Upon Request |
| Brand | Misonix |
|---|---|
| Origin | USA |
| Model | Sonicator 4000 |
| Output Power | 600 W |
| Operating Frequency | 20 kHz |
| Sample Volume Range | 0.1–4000 mL |
| Pulse Duration Adjustable | 1 s–24 hr |
| Continuous Operation Capability | 72 hr |
| Dimensions (W × D × H) | 27.9 × 50.8 × 13.9 cm |
| Weight | 12.0 kg |
| Probe Types | Tapped & Stepped, Diameter Range: 1.6–25.4 mm |
| Control Interface | Full Digital Touchscreen |
| Compliance | Designed for GLP/GMP-adjacent workflows, supports audit-ready operation with optional temperature probe (TP4000) |
| Brand | Misonix |
|---|---|
| Origin | USA |
| Model | XL2000 |
| Maximum Output Power | 100 W |
| Operating Frequency | 22.5 kHz |
| Sample Volume Range | 0.2–50 mL |
| Dimensions (W × D × H) | 19.0 × 33.0 × 17.8 cm |
| Weight | 4.1 kg |
| Display | LCD Digital Interface |
| Operating Modes | Continuous & Pulse |
| Probe Options | P-1 (1/8″, 0.5–15 mL), P-2 (3/16″, 2–25 mL), P-3 (3/32″, 0.2–5 mL), P-4 (1/4″, 5–50 mL) |
| Optional Accessories | Acoustic Enclosure, Cup Horn (Non-contact Sonication) |
| Brand | Merck |
|---|---|
| Origin | USA |
| Manufacturer | Merck KGaA, Darmstadt, Germany |
| Product Line | Mobius® CellReady |
| Vessel Volume | 3 L (working volume) |
| Configuration | Benchtop Stirred-Tank Bioreactor |
| Sterility | Pre-sterilized, Gamma-Irradiated |
| Material | USP Class VI–compliant Polymeric Film (Multi-layer EVOH barrier) |
| Controller Compatibility | Compatible with standard Mobius® controllers (e.g., Mobius® Control Unit, or third-party PID-based bioreactor controllers via analog/digital I/O) |
| Regulatory Support | Designed for use in process development under GMP-aligned workflows |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | SpectraMax Drop |
| Pricing | Available Upon Request |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer | Molecular Devices, LLC |
| Product Type | Imported Instrument |
| Model | Threshold® |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model Variants | BLCC03 (3-Channel), BLCC06 (6-Channel) |
| Price Range | USD 2,800 – 7,000 |
| Material | 316 Stainless Steel |
| Connection to Filter Units | #8 Rubber Stopper |
| Connection to Vacuum Flask | Φ6 mm Silicone Tubing |
| Sterilization | Autoclavable at 121°C for 30 min |
| Dimensions (BLCC03) | 400 × 150 × 160 mm |
| Weight (BLCC03) | 8.0 kg |
| Dimensions (BLCC06) | 820 × 150 × 160 mm |
| Weight (BLCC06) | 12.0 kg |
| Packaging | 1 set per carton |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | MX100-4A |
| Instrument Type | Microplate Shaker |
| Timer Range | 99 h 59 min |
| Oscillation Frequency | 200–1500 rpm (standard), 300–1000 rpm (full load) |
| Oscillation Amplitude | 3 mm horizontal orbital |
| Temperature Control | Ambient only |
| Plate Capacity | 4 standard microplates (96-well, 384-well, 24-/48-well plates) |
| Dimensions | 280 × 270 × 110 mm |
| Weight | 7 kg |
| Motor Type | Brushless DC motor |
| Display | LED digital display |
| Alarm | Audible end-of-program signal |
| Optional Accessory | 1.5/2.0 mL centrifuge tube holder |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Blaze™ System |
| Volume Range | 1 L (Blaze™) / up to 10 L (Blaze+™) |
| System Architecture | Closed, single-use, GMP-ready process development platform |
| Core Technology | NxGen™ microfluidic mixing |
| Regulatory Alignment | Supports FDA 21 CFR Part 11–compliant data integrity, GLP/GMP process transfer readiness |
| Disposable Components | NxGen™ single-use chips (with/without inline dilution), sterile tubing kits for external vessel integration |
| Downstream Compatibility | Integrated TFF, sterile filtration, and fill-finish workflow support |
| Scalability Pathway | Direct CPP/CQA transfer from Blaze™ → Blaze+™ → NanoAssemblr™ Production System |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | NanoAssemblr™ Commercial Manufacturing System |
| Pricing | Upon Request |
| Flow Rate Range | 6–48 L/h (dependent on disposable flow path kit) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ GMP System |
| Flow Rate Range | 60–200 mL/min (3.6–12 L/h) |
| Brand | Cytiva |
|---|---|
| Origin | Switzerland |
| Model | NanoAssemblr™ Spark™ Instrument |
| Sample Volume Range | 25–250 µL |
| Mixing Technology | NxGen™ Microfluidic Vortex Mixing |
| Sterility Design | BSC-Compatible, Aseptic Operation Ready |
| Chip Type | Single-Use, Gamma-Irradiated Cartridge |
| Scalability Pathway | Seamless Transition to NanoAssemblr™ Ignite™ and NxGen™ Production Platforms |
| Regulatory Context | Designed for GLP-compliant early-stage development, supports 21 CFR Part 11–ready software integration (optional) |
| Brand | NanoEX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | NanoEX |
| Price Range | USD 70,000 – 140,000 |
| Dimensions | 537 × 260 × 363 mm |
| Weight | 10 kg |
| Throughput | Up to 168 mL/h |
| Sample Volume Range | 100 µL – 500 mL |
| Display | Integrated TFT touchscreen |
| Sterilization Compatibility | Autoclavable components |
| Membrane Compatibility | Interchangeable asymmetric nanopore membrane (ANM) cassettes |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | IM-31 |
| Operating Modes | Count Mode (Pressure/Time/Count), Footswitch Mode (Pressure Only) |
| Pressure Range | 50–500 kPa |
| Time Setting Range | 10 ms – 99.99 s |
| Count Setting Range | 1–99 |
| Interval Setting Range | 10 ms – 99.99 s |
| Input Voltage | AC 100–240 V (±5%), 50/60 Hz |
| Dimensions | 240 × 215 × 130 mm |
| Weight | 4 kg |
| TTL Input | Negative logic compatible |
| Compatibility | Modular integration with Narishige micromanipulators (e.g., MMO-4, MDO-84) via adapter kits |
| Accessories | HI-7 syringe holder, tubing connectors, footswitch, silicone O-rings, power cord |
| Brand | NARISHIGE |
|---|---|
| Origin | Japan |
| Model | NT88-V3 |
| Type | Motorized/Hydraulic Hybrid Micromanipulator System |
| Compatibility | Designed exclusively for Nikon TE2000-series inverted microscopes |
| Positioning Resolution | Sub-micrometer (hydraulic fine control) + motorized coarse positioning |
| “Co-location” Function | Yes, enables rapid return to pre-set reference coordinates after dish exchange |
| Integrated XYZ Scale Indicators | Yes, independent mechanical scales for X, Y, Z axes |
| Vibration-Damped Microscope Interface | Yes, optimized for stable operation on optical tables or anti-vibration platforms |
| Ergonomic Joystick Controller | Height-adjustable, space-saving footprint |
| Primary Applications | Intracytoplasmic Sperm Injection (ICSI), transgenic embryo microinjection, fluorescent dye/indicator delivery, patch-clamp electrode positioning, nuclear transfer |
| Brand | NEPA GENE |
|---|---|
| Origin | Japan |
| Model | PF-NP-200 |
| Temperature Range | −80 °C to Ambient |
| Cooling Rate | −0.1 to −3.0 °C/min |
| Cooling Technology | Stirling Cycle Refrigeration |
| Display | LCD Touchscreen Interface |
| Data Export | CSV Format |
| Power Supply | AC 100 V, 50/60 Hz |
| Power Consumption | 200 W |
| Dimensions (L×W×H) | 340 × 366 × 466 mm |
| Weight | 18 kg |
| Sample Capacity | 55 × 2 mL Cryovials or 1 × 25 mL Cryobag (optional modules available) |
| Restart Function | Auto-resume after power failure |
| Compliance | Designed for GLP-compliant cell banking and ISO 13485-aligned bioprocessing environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Kuiqpick |
| Quotation | Upon Request |
| Vacuum Pressure Range | 0–588.8 mmHg |
| Vacuum Pulse Duration | 0–1 s |
| Linear Actuator Step Resolution | 1.5 µm |
| Linear Actuator Max Travel | 8.9 mm |
| Linear Actuator Max Speed | 0.35 mm/s |
| Illumination | 144-LED Ring Light (Lifespan: 10,000 h) |
| Compatible Tissue Thickness | 5–300 µm |
| Compatible Sample Types | Fresh-frozen, sucrose-processed, and live unfixed tissues |
| Capillary Inner Diameters | 15, 20, 30, 40, 50, 60, 80, 100 µm |
| Capillary Total Length | 4.2 ± 0.2 cm |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 30–80% (at 31 °C) |
| Compatible Microscopes | Olympus CKX31/CKX41, Labomed TCM400 |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | GT-3.0 |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 1000 W |
| Test Pressure Range | 300–1500 Pa (adjustable) |
| Leak Rate Detection Limit | ≤10 Pa |
| Noise Level | ≤50 dB(A) |
| Operating Mode | Continuous |
| Weight | ~45 kg |
| Dimensions | 400 mm × 383 mm × 1100 mm |
| User Management | Multi-level Access Control with Electronic Signature Compliance |
| Communication | Customizable Protocol Support for SCADA/DCS Integration |
| Software | PC-based Data Acquisition and Reporting Suite with Audit Trail Capability |
| Brand | NeuronBC |
|---|---|
| Model | NBTB |
| Material | Sintered Titanium Powder |
| Filtration Accuracy | 1–50 µm (standard options: 1, 2, 3, 5, 10, 15, 30, 50 µm) |
| Porosity | 35–45% |
| Air Permeability Coefficient | 5×10⁻⁷ – 1×10⁻⁴ L/cm²·min·Pa |
| Minimum Burst Strength | ≥4 MPa |
| End Cap Configurations | Threaded, 222, 226, Flat-Plate |
| Outer Diameter | 30–80 mm |
| Length | 5", 10", 20", 30", 40" |
| Origin | Beijing, China |
| Regulatory Compliance | Designed for USP <788>, ISO 4074, and GMP-compliant bioprocessing environments |
| Brand | NeuronBC |
|---|---|
| Model | NL |
| Filter Material | Nylon 6 / Nylon 66 |
| Pore Sizes | 0.1 µm, 0.22 µm, 0.45 µm, 0.65 µm, 0.8 µm, 1.2 µm |
| Filtration Area | 0.60 m² |
| Bubble Point (0.22 µm) | ≥ 0.28 MPa |
| Bubble Point (0.45 µm) | ≥ 0.18 MPa |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Service Temperature | ≤ 65°C @ 0.21 MPa |
| Steam Sterilization | 121°C, 0.1 MPa, 30 min per cycle (up to 30 cycles) |
| Delta-P Replacement Threshold | 0.20 MPa |
| Housing & Endcaps | Polypropylene (PP) |
| Core Support | 304 or 316 Stainless Steel |
| Internal Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Silicone or Fluoroelastomer (FKM) |
| Pure Water Flow Rate (ΔP = 0.01 MPa) | 3.3 L/min (0.22 µm), 5.1 L/min (0.45 µm) |
| Bacterial Retention | ≥ 10⁷ CFU/cm² |
| Integrity Test Method | Forward Flow / Bubble Point |
| Compliance | GMP-compliant manufacturing, pre-sterilized options available, fully traceable lot documentation |
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE |
| Filtration Rating (Liquid) | 0.22 µm & 0.45 µm |
| Filtration Rating (Gas) | 0.01 µm |
| Bubble Point | ≥ 0.08 MPa (95% IPA) |
| Diffusion Flow | ≤ 5.5 mL/min (60:40 IPA:Water at 0.064 MPa) |
| Gas Flow Rate (Hydrophobic, 0.01 µm) | ≥ 6 m³/min (ΔP = 0.015 MPa at 0.13 MPa inlet) |
| Water Flow Rate (Hydrophilic, 0.22 µm) | ≥ 6.89 L/min (ΔP = 0.01 MPa at 0.13 MPa inlet) |
| Max Operating Pressure (Forward) | 0.42 MPa @ 25°C |
| Max Reverse Pressure | 0.21 MPa @ 25°C |
| Max Service Temperature | 65°C @ 0.21 MPa (Standard), 95°C @ 0.1 MPa (High-Temp Grade) |
| Sterilization | 142°C @ 0.276 MPa (Autoclave) |
| Online Steam | 135°C @ 0.1 MPa, 30 min per cycle (up to 160 cycles) |
| Max ΔP for Replacement | 0.20 MPa |
| Housing Material | Polypropylene (PP) |
| Core Support | PP, 304 SS, or 316 SS |
| End Cap & Connector | PP |
| Support Layer | Imported Polyester Nonwoven |
| Seal Materials | Food-Grade EPDM, Silicone, or FKM |
| Effective Filtration Area | 0.70 m² (10-inch format) |