Bioengineering Equipment
Filter
Showing 1081–1110 of 1954 results
| Brand | NeuronBC |
|---|---|
| Origin | Beijing, China |
| Model | PTFE-NWF |
| Filtration Rating | 0.2 µm (liquid), <0.01 µm (gas), <0.003 µm (dual-layer) |
| Max Operating Temperature | 90 °C @ 0.20 MPa |
| Sterilization | 121 °C, 30 min (≥50 cycles) |
| Forward Pressure Rating | 0.42 MPa @ 25 °C |
| Reverse Pressure Rating | 0.21 MPa @ 25 °C |
| Endotoxin Level | <0.25 EU/mL |
| Extractables | <10 mg per 10-inch cartridge (Φ69 mm) |
| Chemical Resistance | Broad compatibility with acids, bases, and organic solvents |
| Brand | NeuronBC |
|---|---|
| Model | PVDF |
| Filter Material | Polyvinylidene Fluoride (PVDF) Microporous Membrane |
| Filtration Area (10″) | 0.60 m² |
| Liquid Sterile Filtration Rating | 0.22 µm |
| Gas Filtration Rating | 0.01 µm |
| Bubble Point (Isopropanol, 0.22 µm) | ≥ 0.065 MPa |
| Air Flow Rate | ≥ 6 m³/min at ΔP = 0.015 MPa (inlet pressure 0.13 MPa) |
| Forward Pressure Drop | 0.42 MPa at 25 °C |
| Reverse Pressure Drop | 0.21 MPa at 25 °C |
| Operating Temperature | ≤ 65 °C (standard), ≤ 95 °C (high-temp grade, 0.1 MPa) |
| Steam Sterilization | 121 °C, 0.1 MPa, 30 min per cycle (validated for ≥ 100 cycles) |
| Housing & Endcap Material | Polypropylene (PP) or PVDF |
| Core Support | Imported Polyester Nonwoven |
| Seal Material | Silicone or FKM (Fluoroelastomer) |
| Chemical Compatibility | Broad resistance to strong acids, aliphatic/aromatic hydrocarbons, ketones, ethers, and halogenated solvents |
| Brand | New Brunswick |
|---|---|
| Origin | USA |
| Model | NB Innova 40 R |
| Instrument Type | Refrigerated Temperature-Controlled Orbital Shaker |
| Timer Range | Continuous Operation |
| Oscillation Speed | 25–500 rpm |
| Orbit Diameter | 190 mm (standard), 250 mm (Innova 40 R) |
| Temperature Range | 5°C above ambient to 80°C |
| Platform | Single 46 × 46 cm stainless-steel shaker platform |
| Certifications | cETL, UL, CSA, CE |
| Sample Capacity | Up to three 3-L Erlenmeyer flasks simultaneously |
| Brand | New Chi / SCIENTZ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TDL |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 0.5–15 mL |
| Number of Simultaneous Channels | 4 |
| Cooling Compatibility | Ice-bath or pre-chilled adapter (1.5–2 mL × 4 wells) |
| Control Mode | Programmable pulsed/continuous operation |
| Memory Capacity | Up to 50 user-defined protocols |
| Safety Features | Real-time temperature monitoring, overload protection, auto-diagnostic error reporting |
| Compliance | Designed for GLP-compliant labs |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-302M |
| Detection Principles | Catalytic Combustion (LEL), Galvanic Cell (O₂), Electrochemical (H₂S, CO) |
| Detection Gases | Combustible Gas (CH₄), Oxygen (O₂), Hydrogen Sulfide (H₂S), Carbon Monoxide (CO) |
| Measurement Ranges | 0–100% LEL |
| 0–25 vol% (extended | 25.1–50 vol%) |
| 0–30 ppm (extended | 30.1–150 ppm) |
| 0–101 ppm (extended | 100–300 ppm) |
| Accuracy | ±2% LEL |
| Response Time | ≤25 s (1 m sampling tube) / ≤40 s (8 m sampling tube) |
| Operating Temperature | −10 °C to +40 °C, ≤95% RH |
| Power Supply | 4 × AA alkaline batteries |
| Continuous Operation | >8 h (20 °C, alarms/background light/data hold OFF) |
| Enclosure Rating | Intrinsic Safety (Ex ibd II BT3), LEL sensor: Flameproof (Ex d) |
| Dimensions | 152 × 152 × 42 mm (excl. protrusions) |
| Weight | ~870 g |
| Display | Backlit LCD (simultaneous 4-gas readout) |
| Alarms | 90 dB audible buzzer, flashing red LED, visual display alert |
| Key Functions | Auto backlight, flow-under detection (pressure sensor), battery/temperature/clock display, zero calibration, data hold, peak hold, alarm silencing, volume adjustment, alarm self-test |
| Standard Kits | 1-m or 8-m sampling hose configurations with filter/floating buoy, carrying case, or aluminum transport case with external alarm & AC adapter |
| Optional | Windows-compatible data logging kit (Windows 2000/XP) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-308B |
| Detection Principle | Potentiostatic Electrolytic (with DNPH-coated filter for VOC interference reduction) |
| Measurement Range | 0.01–0.38 mg/m³ (service range: 0.39–3.00 mg/m³) |
| 0.01–0.30 ppm (service range | 0.31–3.00 ppm) |
| Sampling Method | Micro-pump–driven active aspiration |
| Measurement Duration Options | 10-min or 30-min integrated sampling modes |
| Display | Digital LCD with bar graph and status indicators |
| Power Supply | Six AA alkaline/manganese batteries or optional DC 9 V AC adapter |
| Battery Life | ~50 measurements (30-min mode) / ~100 measurements (10-min mode) using manganese batteries |
| Filter Lifetime | 50 measurements (30-min mode) / 100 measurements (10-min mode) at 0.10 mg/m³ average formaldehyde concentration |
| Operating Temperature | 5–40 °C |
| Dimensions | 175 × 140 × 86 mm (W × H × D) |
| Weight | Approx. 2.5 kg (including batteries) |
| Data Storage | 32 measurement records |
| Accessories Included | Three DNPH filter cartridges, six AA manganese batteries, sampling tube, ten particulate filter discs, tweezers |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3110 |
| Detection Principle | Catalytic Bead (Pellistor) |
| Detection Range | 0–10% LEL and 0–100% LEL (dual-range) |
| Display | 4-digit LCD with backlight |
| Accuracy | ±5% of full scale |
| Response Time (T90) | <3 seconds |
| Alarm Threshold | 20% LEL (audible/visual) |
| Power Supply | 4 × AA alkaline batteries (6 V DC) |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions | 82 mm (W) × 162 mm (H) × 36 mm (D) |
| Weight | ~450 g (including batteries) |
| Sampling Method | Built-in micro diaphragm pump (active draw) |
| Certification | Intrinsically Safe (Ex ib IIB T4 Ga) |
| Compliance | JIS T 8201, JIS Z 8001, JIS C 0901, ATEX Directive 2014/34/EU (via representative EU importer), IEC 60079-0/-11 |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3140 |
| Weight | 450 g |
| Power Supply | AA alkaline batteries or dedicated rechargeable battery pack |
| Display | Dual-mode (digital + bar-graph) |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-3160 |
| Detection Principle | Catalytic Bead (Contact Combustion) |
| Detection Method | Pump-Aspirated |
| Measurable Gases | Combustible gases & vapors of combustible organic solvents (e.g., diesel, propane, methane, hexane) |
| Range | 0–5000 ppm or 0–1 vol% (auto-ranging) |
| Accuracy | ±5% FS (H-range), ±10% FS (L-range) |
| Alarm Thresholds | 250 ppm / 500 ppm (user-selectable) |
| Display | Backlit LCD with dual-mode output — numeric (0–5000 ppm / 0–1 vol%) and bar-graph scale (auto-switching between L-range: 0–500 ppm / 0–1000 ppm and H-range: 0–5000 ppm / 0–1 vol%) |
| Alarm Output | Audible buzzer + red LED flash (gas/fault) |
| Intrinsic Safety Rating | Ex ib d IIB T3 (combined intrinsic safety + flameproof enclosure) |
| Operating Temperature | −20 °C to +50 °C |
| Power Supply | Four AA alkaline batteries or optional Ni–Cd rechargeable pack |
| Battery Life | ~20 h (alkaline, no alarm/backlight), ~5 h (Ni–Cd, no alarm/backlight) |
| Dimensions | 82 × 162 × 36 mm (W × H × D) |
| Weight | ~450 g (without batteries) |
| Data Logging | Internal memory (standard) |
| Flow Anomaly Self-Check | Yes |
| Accessories Included | Leather carrying case, 4 × AA alkaline batteries, 1 m sampling hose, filter cartridge, filter disc, stainless steel probe tube, rubber suction tip |
| Optional Accessories | Extended sampling hose, gas mixer, data download kit (CD-ROM + USB cable), Ni–Cd battery pack, charger |
| Brand | New Cosmos |
|---|---|
| Origin | Japan |
| Model | XP-329M |
| Sensor Type | High-sensitivity tin oxide (SnO₂) sintered semiconductor |
| Display | 7-segment LED, 3.5-digit (000–999) |
| Measurement Range | 000–999 arbitrary odor units |
| Repeatability | ±5% ±1 digit (under identical conditions) |
| Sampling Method | Active aspiration (flow rate: 350 ± 100 mL/min) |
| Response Time (90%) | ≤20 s (with calibration odor) |
| Power Supply | 3 × AA alkaline batteries |
| Battery Life | Up to 10 h (at 25°C, typical use) |
| Operating Environment | 0–40°C, 10–80% RH (non-condensing) |
| Storage Environment | −10–50°C, ≤80% RH (non-condensing) |
| Dimensions (W×H×D) | 60 × 140 × 40 mm (excl. protrusions) |
| Weight | ≈300 g (incl. batteries) |
| Analog Output | DC 0–0.99 V (corresponding to 000–999 display) |
| Data Memory Capacity | 18,000 records |
| Included Accessories | Filter unit, 3 × AA alkaline batteries, set of 10 filter discs |
| Brand | FUJIKIN |
|---|---|
| Origin | Japan |
| Model | 112-605 |
| Power Supply | 100 V, 50/60 Hz AC |
| Maximum Stack Capacity | 25–30 sheets (64 g/m² paper) |
| Punch Cycle Time | 0.5 s per stroke (50/60 Hz) |
| Dimensions (W×D×H) | 277 × 436 × 308 mm |
| Weight | 37.7 kg |
| Die Block Compatibility | MOLE 605-112 |
| Compliance | Designed for GLP/GMP-aligned documentation integrity workflows |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | DNU-8020 |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Operating Frequency | 35–40 kHz |
| Ultrasonic Power Output | 50 W |
| Sample Volume per Tube | 2 mL |
| Maximum Simultaneous Samples | 8 |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | JY88-PRO |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 4.5–450 W |
| Sample Volume Capacity | 10–200 mL |
| Sample Throughput | Single-sample mode |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1200 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1000 mL |
| Sample Throughput | Single-sample processing |
| Transducer Material | Titanium Alloy Probe |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 19.5–20.5 kHz |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Sample Throughput | Single-sample processing per cycle |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | L1.5-8 Series |
| Temperature Range | –80 °C to 20 °C |
| Temperature Accuracy | ±0.5 °C |
| Control Algorithm | PID Fuzzy Logic |
| Communication Interface | RS-485 with MODBUS RTU Protocol |
| Display | 7-inch color touchscreen with real-time temperature curve visualization and logging |
| Programmability | Up to 5 multi-step programs (30 segments per program) |
| Temperature Feedback Points | Three independent PT100 inputs (unit internal temp, outlet fluid temp, external process material temp) |
| Safety Protections | Compressor overload protection, high-pressure switch, thermal relay, overheat sensor, low-fluid-level detection, sensor fault monitoring, self-diagnostic system |
| Circulation System | Fully sealed closed-loop design |
| Fluid Operating Range | –25 °C to 200 °C |
| Temperature Differential Control | Adjustable setpoint offset between jacket and process material temperature |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1.5 L (total) |
| Throughput | 8 or 16 samples per run |
| Cooling Interface | Integrated recirculating chiller port (4–10 °C operational range) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-08-II |
| Instrument Type | Non-contact ultrasonic cell disruptor (cup-horn system) |
| Operating Frequency | 40 kHz |
| Adjustable Ultrasonic Power | 1800 W |
| Sample Volume Range | 5 µL – 15 mL |
| Sample Capacity | 1–16 tubes |
| Power Adjustment Range | 1–99% |
| Timer Range | 1–999 min |
| Duty Cycle | 0.1–99.9% |
| Tank Volume | 1.5 L |
| Compatible Vessel Formats | 1–2 mL × 16 wells, 5 mL × 8 wells, 10–15 mL × 8 wells |
| Temperature Monitoring | Yes |
| Input Voltage | 220/110 V ±0.5%, 50/60 Hz |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power | 2200 W |
| Operating Frequency | 40 kHz |
| Sample Volume Capacity | 1–2 mL, 5 mL, or 10–15 mL per tube |
| Throughput | 17, 20, or 32 samples per run |
| Cooling System | Integrated recirculating chiller-compatible jacket (operating range: 4–10 °C) |
| Sample Container Compatibility | Standard microcentrifuge tubes (1.5/2.0 mL), PCR strips, and custom cryovials |
| Control Interface | Digital touchscreen with programmable protocols (time, amplitude, pulse mode, cycle count) |
| Safety Certification | CE-compliant design |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Non-Contact Ultrasonic Cell Disruptor |
| Ultrasonic Power Output | 1800 W |
| Operating Frequency | 20 kHz (±0.5 kHz) |
| Sample Volume Capacity | 900 mL |
| Sample Throughput | 1 tube per cycle (rotating holder supports single-tube continuous rotation) |
| Temperature Control | Integrated jacketed cup with external chiller compatibility (4–10 °C typical operational range) |
| Cooling Interface | Dual-layer borosilicate glass cup with external recirculating coolant port |
| Minimum Sample Volume | 5 µL |
| Acoustic Isolation | Built-in acoustic enclosure with transparent viewing window |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-1000J |
| Temperature Range | 0–99.9 °C |
| Operating Frequency | 20–25 kHz |
| Ultrasonic Power Output | 1000 W (adjustable in 1% increments) |
| Duty Cycle | 0.1–99.9% |
| Sample Volume Capacity | 10–200 mL |
| Alarm Functions | Overtemperature, Overload, and Timer Alert |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 50–1200 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 50–1200 mL |
| Multi-sample Processing Capability | Yes |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-16TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Power Output | 2400 W |
| Sample Volume per Tube | 1–20 mL |
| Parallel Processing Capacity | 16 samples |
| Cooling Mode | Integrated temperature-controlled rack (ambient to ~15 °C recommended) |
| Pulse Mode | Adjustable on/off duty cycle |
| Protection Features | Overtemperature, overload, and system self-diagnosis |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-24TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Total Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 100 µL – 5 mL |
| Parallel Processing Capacity | 24 samples |
| Cooling Method | Integrated Temperature-Controlled Rack (External Chiller Interface Supported) |
| Pulse Mode | Adjustable Duty Cycle (Continuous / Intermittent) |
| Programmable Protocols | Up to 20 user-defined methods |
| Safety Features | Overtemperature & Overload Protection, Real-time System Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-48TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Maximum Ultrasonic Power | 2400 W |
| Sample Volume per Tube | 100 µL – 4 mL |
| Parallel Processing Capacity | 48 Samples |
| Temperature Control | Not Specified (External Cooling Required) |
| Pulse Mode | Adjustable Continuous or Duty-Cycle Mode |
| Programmable Protocols | Up to 20 User-Defined Methods |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-4TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Channel | 1–20 mL |
| Number of Simultaneous Samples | 4 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Onboard Memory for Up to 20 User-Defined Protocols |
| Safety Features | Real-time Overtemperature & Overload Detection, Auto-Shutdown, Fault Diagnostics |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Ultrasonic Power Range | 5–650 W (continuously adjustable) |
| Operating Frequency | 20–25 kHz (auto-tracking & adaptive) |
| Temperature Control Range | 0–99 °C |
| Sample Volume Capacity | 100 µL–500 mL |
| Multi-sample Processing Capability | Yes |
| Safety Features | Overtemperature, overload, and time-out alarms |
| Control Interface | Remote network connectivity (Ethernet/RS232) |
| Design | Stackable benchtop configuration with transparent front access panel and internal LED illumination |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650J |
| Design | Integrated Benchtop System |
| Transducer Material | TC4 Titanium Alloy (Grade 5 Ti-6Al-4V) |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (duty cycle programmable) |
| Safety Features | Overload, overtemperature, and timeout alarms |
| Acoustic Enclosure | Multi-layer acoustic damping panels (STC-rated) |
| Control Interface | Programmable digital controller with remote lift actuation |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-650L |
| Cooling | Built-in Refrigeration System |
| Power Adjustment | 1–100% in 1% increments |
| Time Resolution | 0.1 s (ultrasonication & interval) |
| Operating Modes | Continuous & Pulse (with test mode) |
| Safety Protections | Overload, overtemperature, and time-out alarms |
| Horn Material | TC4 Titanium Alloy (Grade 5, ASTM B348) |
| Acoustic Enclosure | Integrated 3D Sound-Dampening Chamber |
| Control | Motorized Vertical Lift with Remote Handheld Controller |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Ultrasonic Cell Disruptor |
| Model | SCIENTZ-6TD |
| Operating Frequency | 20 kHz ± 0.5 kHz |
| Ultrasonic Output Power | 2400 W |
| Sample Volume per Tube | 1–50 mL |
| Number of Simultaneous Samples | 6 |
| Cooling Method | Integrated Temperature-Controlled Jacket (External Circulator Required) |
| Pulse Mode | Adjustable Continuous or Intermittent (Duty Cycle Programmable) |
| Control Interface | Touchscreen with Embedded Microprocessor |
| Program Storage | Up to 20 User-Defined Protocols |
| Safety Features | Real-Time Overtemperature & Overload Monitoring, Auto-Shutdown, Fault Diagnostics |