Agilent Technologies
Filter
Showing 151–180 of 567 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5890 II S/SL |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 5890 II GC |
| Price Range | USD $1,200 – $6,500 (FOB) |
| Product Category | Chromatography |
| Operational Age | ≥7 years |
| Warranty | 6 months limited hardware warranty |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5890II TCD |
| Price Range | USD $6,800–$13,600 (FOB) |
| Product Category | Chromatography |
| Operational Age | 4–5 years |
| Warranty | 6 months |
| Detector Configuration | Thermal Conductivity Detector (TCD) + Split/Splitless (S/SL) Inlet |
| Oven Temperature Range | 4°C above ambient to 450°C |
| Temperature Programming | Up to 3 ramps, initial/final holds, 0.1–70°C/min ramp rates, max 650 min run time |
| Injector Zones | Five independently heated zones |
| Column Compatibility | Capillary columns up to 1.2 mm OD |
| TCD Operating Range | Up to 400°C |
| TCD Minimum Detectable | 400 pg/mL carrier gas (equivalent to 1 ppm neon in 1 mL air) |
| TCD Linear Dynamic Range | ±5% over 10⁵ |
| FPD Optional Configurations | Sulfur mode (20 pg S/s, selectivity 10⁵ g S/g C), Phosphorus mode (0.9 pg P/s, selectivity 10⁶ g P/g C) |
| Septum Purge | Built-in at 3 mL/min |
| Back-Pressure Control | Enables independent split flow adjustment without affecting column flow |
| Injection Modes | Split and splitless (purge time adjustable in 0.01-min increments) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5900 ICP-OES |
| Instrument Type | Full-Spectrum Direct-Reading |
| Detection Limit | S (180.669 nm) < 5 µg/L |
| Repeatability | ≤1.0% RSD |
| Short-Term Stability | RSD ≤0.5% |
| Wavelength Range | 167–785 nm |
| Optical Resolution | ≤0.0065 nm (at As 188.980 nm) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5973N (G2576A) |
| Vacuum System | 90 L/s diffusion pump or 250 L/s turbomolecular pump |
| Ion Source | Independently heated electron ionization (EI) source |
| Mass Analyzer | Heated hyperbolic quadrupole mass filter |
| Detector | High-energy dynode (HED) electron multiplier |
| GC/MS Interface | Independently heated transfer line |
| Operating Age | 4 years |
| Warranty | 6 months |
| Compliance | Designed for integration with Agilent 6890 GC systems |
| Software Control | PC-based data system supporting tuning, full-scan acquisition, SIM, spectral library search (NIST), quantitation, and report generation |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5975C VL MSD |
| Instrument Type | Quadrupole Mass Spectrometer (Electron Ionization) |
| Detection Principle | Electron Impact Ionization (EI) with Triple-Axis HED-EM Detector |
| Operating Temperature Range | Ion Source up to 350 °C, Quadrupole up to 200 °C |
| Mass Range | 1.6–1050 u |
| Mass Resolution | Unit Mass Resolution (Standard) |
| Dynamic Range | >10⁶ (Peak-to-Peak) |
| Typical Detection Limit (IDL) | <10 fg OFN (Octafluoronaphthalene) in Full Scan Mode |
| Software Platform | Agilent ChemStation (G1701EA) with DRS v2.x and TID Support |
| Compliance | ASTM E260, ISO 17025 (when operated under GLP conditions), USP <1225>, FDA 21 CFR Part 11 (with validated configuration) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5975T |
| Price | USD $350,000 |
| Product Category | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty Period | 6 months |
| Instrument Model | 5975T |
| Operational Age | 4 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 5975T |
| Instrument Type | Portable GC-MS |
| Mass Range | 1.8–1050 amu |
| Dynamic Range | 6 orders of magnitude |
| Mass Resolution | Unit mass resolution, tunable via MS calibration |
| Maximum Scan Rate | 12,500 amu/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5975T |
| Mass Range | 1.8–1050 amu |
| Dynamic Range | 6 orders of magnitude |
| Mass Resolution | Unit mass resolution (tunable via tuning) |
| Maximum Scan Rate | 12,500 amu/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | 5977C GC/MSD |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | m/z 0.6 to 1091 |
| Sensitivity | HES EI – 10 fg IDL, 1 µL OFN injection |
| Hydro Inert Source with H₂ carrier – 100 fg OFN, 1 µL injection | IDL 50 fg |
| Scan Speed | ≤ 20,000 Da/s |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5982-9110 |
| Automation Level | Manual |
| Channel Count | 12-channel |
| Extraction Type | Column-based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Compatibility | Up to 5 different elution solvents |
| Sample Capacity | 24 samples per run (with optional rack configuration) |
| Sample Loading Volume | 1–30 mL |
| Wetted Materials | Borosilicate glass, PTFE, UHMW polyethylene |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 5982-9120 |
| Automation Level | Manual |
| Channel Count | 20-Channel |
| Extraction Type | Column-Based SPE |
| Flow Rate Control Range | 0.1–30 mL/min |
| Solvent Types Supported | Up to 5 Different Solvents |
| Sample Capacity | 20 Samples |
| Sample Loading Volume | 1–30 mL |
| Wetted Materials | Borosilicate Glass, PTFE, UHMW Polyethylene |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6100 |
| Instrument Type | Single Quadrupole LC/MS (not Tandem Quadrupole) |
| Scan Speed | Up to 10,000 u/s |
| Detection Limit | Sub-picogram (with Agilent Jet Stream Technology on 6130/6150 variants) |
| Compatibility | Fully Integrated with Agilent 1220/1260/1290 Infinity LC Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6110A |
| Mass Range | 10–1500 m/z |
| Mass Accuracy | ±0.13 u (scan mode, calibrated range) |
| Mass Stability | ±0.1 u / 12 h |
| Scan Speed | 2500 u/s |
| ESI Sensitivity (SIM) | 10 pg reserpine (m/z 609.3), 100:1 RMS |
| Ionization Modes | ESI & APCI |
| Warranty | 6 months |
| Operational Age | ~3 years |
| Configuration | Integrated with Agilent 1200 Prep HPLC (dual G1361A pumps, G2258A autosampler, G1364B fraction collector, G1315B UV-Vis detector) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Time-of-Flight Mass Spectrometer (oa-TOF) |
| Model | 6210 |
| Configuration | Integrated with Agilent 1200 Series LC (G1312A Binary Pump, G1313A Autosampler, G1316A Column Oven, G1322A Degasser) |
| Ionization Sources Supported | ESI, APCI, APPI, MMI |
| Flow Regime Compatibility | Conventional, Micro, and Nano-LC |
| Operational Age | 4 years |
| Warranty | 6 months |
| Regulatory Readiness | Compliant with GLP/GMP data integrity expectations |
| Software Platform | MassHunter Workstation (vB.07.x or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6224 |
| Instrument Type | Mass Spectrometer |
| Usage Duration | 3–4 years |
| Warranty | 6 months |
| Configuration | Fully Tested and Refurbished LC/MS System |
| Compliance | Designed for GLP/GMP- and FDA 21 CFR Part 11–compatible workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | 6230B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) LC/MS System |
| Mass Accuracy | <1 ppm (RMS) |
| Mass Resolution | >22,000 (FWHM at m/z 556) |
| Acquisition Rate | Up to 30 spectra/sec |
| Dynamic Range | 5 orders of magnitude |
| Sensitivity | Sub-picomolar on-column detection (using Agilent Jet Stream ESI source) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6230B |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Mass Accuracy (Positive Mode) | <1 ppm RMS |
| Acquisition Rate | 30 spectra/sec |
| Resolution (FWHM) | >22,000 at m/z 1522, independent of acquisition speed |
| Mass Range | m/z 25–20,000 |
| Ion Sources | ESI, AJS-ESI, APCI, Dual ESI/APCI, NanoESI, CE-ESI, GC-APCI |
| Dynamic Range (within single spectrum) | 5 decades |
| Polarity Switching Duty Cycle | <1 sec |
| Mass Stability | <2 ppm / 2 °C |
| Software Platform | MassHunter Suite (including WalkUp, BioConfirm, Mass Profiler Professional, Vista, Flux) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6460C |
| Configuration | Includes Agilent 1290 Infinity uHPLC, Jet Stream Electrospray Ionization Source, MassHunter Workstation Software, and Dedicated PC |
| Warranty | 90-day comprehensive hardware warranty |
| Compliance | Fully tested per Agilent-recommended performance verification protocols (PVPs) for sensitivity, mass accuracy, retention time stability, and MRM reproducibility |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 6470 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | Universal |
| Sensitivity | Up to 5× higher than conventional ESI sources |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer | Agilent Technologies |
| Import Status | Imported |
| Model | 6470B |
| Instrument Type | Triple Quadrupole (TQ) |
| Application Scope | General-Purpose |
| Mass Range | m/z 5–3000 |
| Sensitivity | < 4 fg on-column ritalin (reserpine), < 4 ppt in solution |
| Resolution Modes | Narrow = 0.4 Da, Unit = 0.7 Da, Wide = 1.2 Da, Widest = 2.5 Da |
| Pressure Range | Not applicable (vacuum-operated system) |
| Ion Sources | Agilent Jet Stream (AJS), Electrospray Ionization (ESI), Atmospheric Pressure Chemical Ionization (APCI), Multi-Mode Ionization (MMI) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | 6475 |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | Universal |
| Mass Range | m/z 5–3000 |
| Sensitivity | < 3.5 fg on-column reserpine (positive mode), < 3.5 ppt IDL (using Agilent Jet Stream Ion Source + Verification Column + 1290 Infinity II LC system) |
| Negative Mode IDL | < 4 fg chloramphenicol, < 4 ppt IDL (same configuration) |
| MRM Transition Rate | 500 transitions/s |
| Quadrupole Resolution (FWHM) | 0.4 Da (narrow), 0.7 Da (unit mass), 1.2 Da (wide), 2.5 Da (broad) |
| Scan Speed | 18,700 Da/s |
| Minimum MRM Dwell Time | 0.5 ms |
| Polarity Switching Time | < 25 ms |
| Collision Cell Cleaning Time | < 1 ms |
| Ion Sources | ESI, APCI, MultiMode (ESI/APCI), Nano-ESI, Agilent Jet Stream (AJS) |
| Dimensions (W × D × H) | 47.5 cm × 77.3 cm × 84 cm |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495 |
| Instrument Type | Tandem Quadrupole (QqQ) Mass Spectrometer |
| LC Integration | Fully Compatible with Agilent 1200/1290 UHPLC Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495B |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Mass Range | m/z 3000 |
| Ion Source | Electrospray Ionization (ESI) / Atmospheric Pressure Chemical Ionization (APCI) |
| Key Technology | iFunnel Ion Optics |
| Maintenance Feature | Plug-and-Play Ion Source with Vacuum Isolation Valve |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495C |
| Instrument Type | Tandem Quadrupole (Triple Quadrupole) |
| Application Scope | General-Purpose Quantitative and Qualitative Analysis |
| Mass Range | 5–3000 m/z |
| Ion Source Maintenance | Vacuum-Shield Enabled (No Vent Required) |
| Key Technology | Third-Generation All-Metal iFunnel, Triggered Multiple Reaction Monitoring (tMRM), Direct Skyline Integration, MassHunter Software Platform |
| Regulatory Compliance | Designed for US FDA 21 CFR Part 11, EU Annex 11, and GLP/GMP Data Integrity Requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 6495D |
| Instrument Type | Tandem Quadrupole (QqQ) |
| Application Scope | General-Purpose Targeted Quantitation |
| Mass Range | m/z 5–3000 |
| Resolution (FWHM) | Unit Mass = 0.7 Da |
| MRM Transition Rate | 700 transitions/s |
| Minimum MRM Dwell Time | 0.5 ms |
| Polarity Switching Speed | <25 ms |
| Ion Sources | ESI, AJS-ESI, APCI, Dual ESI/APCI, Nano-ESI |
| Vacuum Pump Options | MS120 Roughing Pump or Edwards nXL200i Oil-Free Dry Pump (Optional) |
| Collision Cell Clean Time | <1 ms |
| Dimensions (W×D×H) | 91.5 cm × 77.3 cm × 47.5 cm |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6520 |
| Product Type | Mass Spectrometer |
| Usage Duration | 4–5 years |
| Warranty Period | 6 months |
| LC Configuration | Agilent 1200 Series (G1312A Binary Pump, G1313A Autosampler, G1316A Column Compartment, G1322A Degasser) |
| Software Platform | MassHunter Workstation |
| Mass Accuracy (MS) | <2 ppm |
| Mass Accuracy (MS/MS) | <5 ppm |
| Resolution (FWHM) | 20,000 at m/z 556 |
| Dynamic Range (within spectrum) | 10× improvement without sensitivity loss |
| Acquisition Speed | up to 10 MS/MS spectra/sec |
| Mass Range | m/z 25–20,000 |
| Included Hardware | Dedicated PC with pre-installed MassHunter software and calibration kits |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6530A |
| Configuration | LC-Q-TOF System with Jet Stream Electrospray Ionization Source |
| Warranty | 90-day hardware warranty |
| Compliance | Fully tested and validated per Agilent factory specifications |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 6530B |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| Pricing | Available Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6540A |
| Instrument Type | Quadrupole Time-of-Flight Mass Spectrometer (Q-TOF) |
| Configuration | Integrated with Agilent 1260 HPLC (G1312B binary pump, G1367E high-performance autosampler, G1316A column oven, G1322A vacuum degasser, G1330B autosampler chiller) |
| Software | MassHunter Workstation (Qualitative & Quantitative Analysis) |
| Dynamic Range | Up to 5 orders of magnitude (within-spectrum) |
| Acquisition Rate | Up to 50 spectra/sec |
| Ion Source | Dual AJS (Advanced Jet Stream) ESI/APCI interface |
| Mass Accuracy | < 2 ppm (internal calibration), < 3 ppm (external calibration) |
| Mass Resolution | > 35,000 FWHM (at m/z 922) |
| Warranty | 6 months |
| Service History | Fully refurbished and performance-verified by SpectraLab Scientific |
| Usage Duration | 4 years |
| Compliance | Designed for GLP/GMP environments |