Agilent Technologies
Filter
Showing 211–240 of 567 results
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890N + 5973N |
| Price | USD 22,000 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973N |
| Instrument Type | Single Quadrupole GC-MS System |
| GC Configuration | Conventional Capillary Gas Chromatograph |
| MS Analyzer Type | Quadrupole Mass Filter |
| Mass Range | 1.5–650 u (nominal mass scale) |
| Resolution | Unit mass resolution (typical, 10% valley definition) |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in full-scan mode (m/z 272, S/N ≥ 10:1) |
| Scan Speed | Up to 6,400 Da/sec (full-scan, 0.1 sec/decade) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N–5975 |
| Instrument Type | Gas Chromatography–Mass Spectrometry (GC–MS) System |
| Condition | Pre-owned, Fully Refurbished & Performance-Verified |
| Operational Age | 2–3 years |
| Warranty | 6 months limited hardware warranty |
| Compliance | Designed to meet ASTM D1945, EPA Method 8260/8270, USP <621>, and ISO/IEC 17025-aligned laboratory requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Detector Options | FID (detection limit <5 pg C/s on propane), TCD, ECD, NPD, FPD, FTD |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Integrated Control | Agilent 7683 Autoinjector |
| Compliance | ASTM D3606, D5503, ISO 10301, USP <621>, FDA 21 CFR Part 11 ready (with ChemStation Plus configuration) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Instrument Type | Gas Chromatograph (GC) |
| Flow Rate Range | 0.001–10.00 mL/min |
| Maximum Operating Pressure | 40 MPa |
| Autosampler Capacity | 100 positions |
| Injection Volume Range | 1–50 µL |
| Oven Temperature Range | 10–60 °C |
| Wavelength Range | 190–700 nm |
| Data Acquisition Rate | 100 Hz |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N-5973 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| Mass Range | 1.6–800 amu |
| Resolution | Unit mass resolution (nominal) |
| EI Sensitivity | ≥20:1 S/N for 1 pg OFN at m/z 272 (full scan) |
| SIM Sensitivity | ≥10:1 S/N for 20 fg OFN at m/z 272 |
| Scan Speed | 11,000 amu/sec |
| Ion Source | Electron Ionization (EI), optional Chemical Ionization (CI) and Negative Chemical Ionization (NCI) |
| GC Oven Temperature Range | Ambient to 400 °C |
| GC Inlet Types | Programmable Temperature Vaporizing (PTV) inlet and split/splitless capillary inlet |
| Mass Spectrometer Operating Temperature | Independently controlled ion source and quadrupole (up to 350 °C) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N (GC) / 5973N (MSD) |
| Instrument Type | Single Quadrupole GC-MS |
| GC Configuration | Capillary Column Inlet with Electronic Pressure Control (EPC) |
| MS Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Mass Range | 1.6–800 u |
| Mass Accuracy | ±0.1 u |
| EI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 20:1 (full scan) |
| 20 fg OFN (m/z 272), S/N ≥ 10 | 1 (SIM) |
| PCI Sensitivity | 100 pg di-tert-butyl methylamine (m/z 183.1), S/N ≥ 75:1 |
| NCI Sensitivity | 1 pg OFN (m/z 272), S/N ≥ 500:1 |
| Quadrupole | Gold-coated quartz, temperature-controlled, hyperbolic geometry |
| Ion Source | Molybdenum alloy, independently heated, inert surface finish |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GCMS 6890N-5973N |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Conventional GC-MS |
| Mass Range | 1–1000 amu |
| Resolution | 1000–2000 (FWHM at m/z 272) |
| Sensitivity | >300:1 (S/N, EI mode, 1 pg octafluoronaphthalene, m/z 272) |
| Scan Speed | 15,000 u/s |
| Ionization Modes | Electron Impact (EI), Chemical Ionization (CI), Negative Chemical Ionization (NCI) |
| Injector Types | Split/Splitless and Programmable Temperature Vaporizing (PTV) inlets |
| Oven Temperature Range | Ambient to 400 °C |
| Mass Accuracy | ±0.1 u |
| Library | NIST 2008 Mass Spectral Library |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | WX-6890N-5973N |
| Service Fee | USD 700–1,400 (excl. parts) |
| Technician Experience | 10 years |
| Instrument Type | Analytical Instrument |
| Response Time | Within 12 hours |
| Service Scope | GC-MS Maintenance, Diagnostics, Calibration, and Component-Level Repair |
| Location | Beijing, China |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | 6890N-5975(G3170A) |
| Product Type | Mass Spectrometer |
| Warranty | None |
| Brand | Agilent Technologies |
|---|---|
| Origin | Canada |
| Model | 6890N-5975(G3172A) |
| Mass Spectrometer Type | Single Quadrupole MSD |
| Instrument Age | 3–4 Years |
| Vacuum System | Pfeiffer Dual-Stage Rotary Vane Pump with Agilent G1099 Exhaust Oil Mist Filter |
| Autosampler | Gerstel MPS2 Multi-Purpose Sampler |
| Configuration | Complete GC/MS System with PC, Acquisition Software (ChemStation E.02.02 or later), and Full Cabling Set |
| Condition | Fully Tested & Verified Operational |
| Warranty | Not Included |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 6890PLUS |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cool-Down Time | ~6 min (450 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–1200 mL/min |
| Carrier Gas Pressure Range & Control | 0–970 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 700 ICP-OES |
| Wavelength Range | 175–785 nm (continuous, gap-free) |
| Focal Length | 0.4 m |
| Echelle Grating Density | 97.4 lines/mm |
| Signal Stability | ≤1.0% RSD (4-hour measurement) |
| RF Generator Frequency | 40.68 MHz |
| Plasma Output Power | 700–1700 W |
| Plasma Cooling Gas Flow | 0–22.5 L/min (adjustable) |
| Detector | High-resolution CCD with >1 million pixels, anti-blooming architecture |
| Compliance | Fully compliant with FDA 21 CFR Part 11 for electronic records and signatures |
| Warranty | 12 months post-installation qualification |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole GC-MS |
| Configuration | Standalone Mass Spectrometer (requires compatible Agilent GC, e.g., 7890B/7820A) |
| Detection Principle | Electron Ionization (EI) and Chemical Ionization (CI) |
| Mass Range | 10–1000 m/z |
| Scan Speed | Up to 20,000 Da/sec in MRM mode |
| Sensitivity | <10 fg OFN (octafluoronaphthalene) in EI MRM mode |
| Mass Resolution | Unit mass resolution (0.7 Da at peak apex) |
| Vacuum System | Dual-stage turbomolecular pump (≥260 L/s for MS region) |
| Interface Temperature | Up to 350 °C |
| Data System Compatibility | Agilent MassHunter Workstation (vB.08.00 or later) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 7000E GC/MS |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| Chromatography Type | Conventional GC/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | Inert Plus EI Ion Source – IDL ≤ 4 fg (10 fg OFN injection) |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent Triple-Axis HED-EM with Extended-Life Electron Multiplier and Dynamically Ramped Iris |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Status | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole Mass Spectrometer |
| GC Configuration | Conventional GC-MS/MS |
| Mass Range | m/z 10–1050 |
| Sensitivity | IDL ≤ 0.3 fg for 1 fg OFN injection |
| Scan Speed | ≤ 20,000 Da/s |
| Detector | Agilent triple-axis high-efficiency dynamic electron multiplier (HED-EM) with extended-life EM and dynamically ramped iris aperture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 8-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 10–250 rpm |
| Bath Volume | 18 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 708-DS |
| Application | USP Apparatus 1–2–5–6 |
| Sample Volume Range | 100 mL to 2 L |
| Temperature Control Accuracy | ±0.2 °C (per USP <711>) |
| Mechanical Qualification (MQ) | Compliant with ASTM E2503 and FDA-recommended MQ protocols |
| Software Integration | Compatible with Agilent Dissolution Software and third-party LIMS via RS-232/USB/Ethernet |
| Warranty | 6 months limited warranty |
| Operational Age | 3–4 years |
| Certifications | Factory-tested and PVT-verified per USP <711> and <724> |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 7100 |
| Instrument Category | Capillary Electrochromatography (CEC) |
| Sample Analysis Scope | Organic Compounds |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7200 |
| Price Range | USD 135,000 – 205,000 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-Time-of-Flight (Q-TOF) |
| GC Configuration | Conventional GC/MS |
| Mass Range | m/z 20–3000 |
| Resolution | >25,000 FWHM at m/z 271.9867, acquisition-rate independent |
| Sensitivity | IDL <60 fg for 100 fg OFN injection |
| Detector | Microchannel plate/scintillator/PMT with ADC electronics |
| Mass Accuracy | <2 ppm (1 pg OFN, m/z 271.9867) |
| Quadrupole Mass Range | m/z 20–1050 |
| Acquisition Rate | 1–50 spectra/sec, resolution-independent |
| Software Platform | Agilent MassHunter |
| GC Compatibility | Fully compatible with Agilent 8890/8860 GC systems and ZOEX thermal modulator for comprehensive 2D-GC (GC×GC) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7500 |
| Product Category | Mass Spectrometer |
| Instrument Age | 6–8 years |
| Warranty | 1 year |
| Condition | Refurbished & Fully Qualified for Routine Lab Use |
| Compliance | Meets original Agilent factory specifications for sensitivity, background, and stability |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Agilent 7500 ICP-MS |
| Price Range | USD 32,000 – 38,500 (FOB) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7500a |
| Instrument Type | Quadrupole ICP-MS |
| Operational Age | 4 years |
| Warranty | 6 months |
| Detection Limit | Sub-part-per-quadrillion (ppq) |
| Linear Dynamic Range | Up to 12 orders of magnitude |
| Sample Throughput | 1–3 min per sample |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Software Platform | Agilent MassHunter Workstation v4.x or later |
| Included Accessories | Standard sample introduction kit, torch, cones, vacuum pumps, cooling system, and calibration standards |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7500c |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 3–4 years |
| Warranty | 6 months |
| Sample Introduction | ASX-500 autosampler (200-position) |
| Matrix Compatibility | Up to 5% acid concentration (excluding HF) |
| Detection Principle | Quadrupole-based mass spectrometry coupled with ICP ion source |
| Core Technology | Octopole Reaction System (ORS) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7500ce |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer |
| Year of Service | 4 years |
| Warranty | 6 months |
| Sample Introduction | ASX-500 Autosampler |
| Detection Range | Sub-ppt to hundreds of ppm |
| Detection Limit | Low-pq to sub-ppq (element-dependent) |
| Linear Dynamic Range | >12 orders of magnitude |
| Analysis Time | 1–3 min per sample |
| Compliance | Designed to support ISO/IEC 17025, ASTM D5673, USP <232>/<233>, EPA Methods 200.8 & 6020B |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7500cx |
| Configuration | Fully Tested & Certified |
| Warranty | 90-Day Comprehensive Coverage |
| Compliance | Meets ASTM D5673, ISO/IEC 17025–aligned operational readiness |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7650A (50-position, G4567A) |
| Sample Capacity | 50 vials (3-tier configuration supported) |
| Maximum Injection Volume | 250 µL |
| Compatible Systems | Agilent 6890N GC, 7890/8890 GC, and 5975/5977 GC-MS platforms |
| Needle Options | Supports 250 µL and 500 µL syringes |
| Injection Modes | Single-injection, multi-injection, priority-sample injection, overlapping sequence execution |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |