Beiguang Precision Instrument
Filter
Showing all 21 results
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Voltage Output | AC/DC 0–50 kV (continuously adjustable up to 100 kV) |
| Power Capacity | 10 kVA |
| Voltage Accuracy | ≤ ±1% |
| Rise Rate | 0.1–5.0 kV/s (user-programmable) |
| Test Modes | AC/DC stepwise ramp, constant-rate ramp, and hold (withstand) testing |
| Protection | Overcurrent cutoff ≤ 0.05 s, dual-level fault alarm (HMI + embedded controller) |
| Electrode Media | Air or insulating oil |
| Compliance | Meets ASTM D149, IEC 60243-1, GB/T 1408.1, and ISO 60243-1 requirements |
| Calibration | Traceable to national metrology institutes (CNAS-accredited certificates available) |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BDH-20KV |
| Breakdown Voltage | 20 kV |
| Arc Current Range | 10–40 mA (continuous or pulsed) |
| Electrode Material | Tungsten Rod |
| Electrode Spacing | 6.35 ± 0.1 mm (IEC) / 6.0 ± 0.1 mm (ASTM) |
| Electrode Force | 0.5 ± 0.05 N |
| Arc Timing Accuracy | ±10 ms |
| Test Voltage Accuracy | ±3% |
| Current Measurement Accuracy | ±1.5% |
| Ambient Temp | 23 ± 2 °C |
| Ambient Humidity | 50 ± 5 %RH |
| Power Supply | 220 V ±5%, 50 Hz, 10 A |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | BDJC-50KV |
| Maximum Test Voltage | 50 kV |
| Compliance Standards | GB/T 1408.1, ASTM D149, IEC 60243-1, GB/T 1695, HG/T 3330, GB 12656 |
| Voltage Accuracy | ±1%–±5% |
| Ramp Rate Range | 0.01–3 kV/s (continuously adjustable) |
| Test Modes | AC/DC, Short-Time Breakdown, Stepwise Withstand, Gradient Ramp |
| Electrode Options | 25 mm & 75 mm brass disk electrodes (standard), optional wire & tubular electrodes |
| Transformer Capacity | 3–10 kVA |
| Safety Protection | 9-level interlock system including door interlock, zero-voltage startup, overvoltage cutoff, mechanical high-voltage limit, overcurrent trip, real-time arc detection, and exhaust ventilation |
| Dimensions (L×W×H) | 1000×600×1400 mm or 1700×600×1400 mm |
| Weight | 100–200 kg |
| Warranty | 3 years full coverage, lifetime technical support |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BEST-121 |
| Price | USD 2,800 (FOB Beijing) |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω (10 decades) |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Accuracy | ±1% (up to 10¹² Ω), ±5% + 2 digits (10¹³–10¹⁴ Ω), ±10–15% + 5 digits (>10¹⁴ Ω) |
| Display | Full-digit LCD |
| Operating Temperature | –10 °C to +50 °C |
| Relative Humidity | <90% RH |
| Power Supply | AC 220 V, 50 Hz, ~10 W |
| Dimensions | 300 mm × 280 mm × 150 mm |
| Weight | ~3.0 kg |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model Series | Beiguang BEST Series |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (selectable) |
| Accuracy | ±2% |
| Display | Dual 3.1/2-digit LED readouts (resistance & current) |
| Compliance | GB/T 1410–2006, ASTM D257–99 |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | 2.5 kg |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | BLD-6000V |
| Supply Voltage | 220 V AC |
| Power Rating | 5 kVA |
| Test Voltage Range | 100–600 V AC |
| Voltage Drop | ≤5% |
| Electrode Spacing | (50 ± 0.5) mm |
| Electrode Material | Stainless Steel |
| Sample Capacity | 5 specimens simultaneously |
| Short-Circuit Current | ≥60 mA for 2 s |
| Filter Paper Thickness | 0.15–0.17 mm |
| Chamber Internal Volume | ≥0.75 m³ |
| Compliance | IEC 60112, ASTM D3638, GB/T 4207 |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | BQS-37A |
| Price | USD 3,500 (FOB Beijing) |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BQS1-19 |
| Price | USD 2,500 (FOB Beijing) |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BT |
| Price | USD 1,050 (FOB Beijing) |
| Basic Accuracy | ≤1% |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V (user-selectable, stepwise) |
| Display | Dual LCD readout (resistance & current simultaneously) |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Compliance | Designed per GB/T 10580–2003, GB/T 1692–2008, IEC 60260, ASTM D257 |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BWD9 |
| Impact Energy | 1 J |
| Impact Velocity | 2 m/s ±0.2 m/s |
| Pendulum Torque (Impact Constant) | 1 N·m |
| Temperature Control Stability | <±0.5 ℃ over 3 min after thermal equilibrium |
| Specimen Holder to Impactor Center Distance | 11 ±0.5 mm |
| Cold Bath Volume | 700 mL |
| Operating Temperature Range | −70 ℃ to 0 ℃ (selectable: −60 ℃, −65 ℃, or −70 ℃ lower limit) |
| Power Consumption | 1100 W |
| Dimensions (W×D×H) | 720 × 700 × 1380 mm |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GDAT-C1 |
| Price | USD 3,500 (FOB Beijing) |
| Compliance | GB/T 5654–2007, IEC 60247 (referenced), ASTM D924 (functional equivalence) |
| Measurement Principle | High-voltage AC/DC bridge method with guarded three-electrode cell |
| Temperature Control | PID-regulated mid-frequency induction heating |
| Display | 7-inch color TFT touchscreen with full Chinese GUI |
| Data Storage | 100 test records with timestamp (RTC integrated) |
| Power Supply | AC 220 V ±10%, 50 Hz, <200 W |
| Dimensions | 420 × 380 × 385 mm |
| Weight | 21 kg |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDJC-10KV |
| Dielectric Breakdown Voltage Range | AC/DC 0–10 kV (configurable up to 20 kV for verification) |
| Voltage Accuracy | ±1% of reading |
| Rise Rate Adjustment | 0.1–5.0 kV/s (programmable) |
| Test Modes | AC/DC ramp-up, stepwise gradient, and hold-at-voltage (0–6 h) |
| Protection Response Time | <50 ms |
| Current Sensing Resolution | 0.1 mA (real-time acquisition) |
| Compliance Standards | GB/T 1408.1–2016, GB/T 1695–2005, ASTM D149, IEC 60243-1, HG/T 3330 |
| Power Supply | 220 V ±10%, 50 Hz ±1% single-phase |
| Enclosure Material | SUS304 stainless steel |
| Communication Interface | USB 2.0 (3 MB/s), RS-232, Bluetooth 5.0, optional Ethernet port |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDJC-50KV |
| Maximum Output Voltage | 50 kV AC/DC |
| Voltage Measurement Accuracy | ≤ ±2% |
| Ramp Rate | 0.1–10 kV/s |
| Power Output | 50 kVA |
| Compliance Standards | GB 1408.1–2006, GB 1408.2–2006, GB/T 1695–2005, ASTM D149 |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BDJC-50kV |
| Maximum Output Voltage | 50 kV AC/DC |
| Voltage Accuracy | ±3% |
| Transformer Capacity | 3 kVA (configurable up to 200 kVA) |
| Compliance | GB/T 1408.1, IEC 60243-1, ASTM D149, ISO 60243-1, IEC 60674-2, GB/T 10580 |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Test Voltage Range | DC 10 V, 50 V, 100 V, 250 V, 500 V, 1000 V |
| Resistance Measurement Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Measurement Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Compliance | GB/T 1410–2006 |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | BWN-5KN |
| Price | USD 3,500 (FOB) |
| Instrument Type | Electromechanical Universal Testing Machine |
| Max Test Load | 0–5 kN |
| Force Resolution | Constant Across Full Scale |
| Effective Force Range | 2–100% of Full Scale |
| Force Accuracy | ±1% of Indicated Value |
| Crosshead Speed Range | 0.05–500 mm/min (Infinitely Variable) |
| Displacement Resolution | 0.01 mm |
| Speed Control Accuracy | ±0.5% |
| Displacement Accuracy | ±0.5% |
| Tensile Stroke | 0–1000 mm (Excluding Fixtures) |
| Power Supply | 220 V AC, 50 Hz |
| Operating System | Windows XP (Legacy Software Environment) |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CLC-300 Series |
| Maximum Impact Energy | 300 J (expandable up to 2000 J) |
| Maximum Drop Height | 2000 mm |
| Drop Mass Range | 0.25–15 kg (±0.1% accuracy) |
| Hammer Nose Radius Options | R=5 mm, R=10 mm, R=20 mm, R=30 mm |
| Specimen Support | Simply Supported Beam Configuration |
| Height Scale Accuracy | ±1% |
| Electromagnetic Catch Force | ≥20 kgf |
| Motorized Lifting Capacity | 20 kgf |
| Alignment Tolerance (Impact Center vs. Fixture Center) | ≤2 mm |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDAT-A (70 MHz) |
| Price | USD 1,850 (approx.) |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HMLS-1000 |
| Price | USD 1,950 (FOB Beijing) |
| Load Capacity | 1000 N |
| Force Accuracy | ±1% of reading (optional ±0.5%) |
| Force Resolution | 1/30,000 full scale |
| Test Speed Range | 0.05–500 mm/min |
| Speed Accuracy | ±1% of set value (optional ±0.5%) |
| Effective Stroke | ≥850 mm |
| Effective Width | 400–550 mm (customizable) |
| Compliance Standards | GB/T 6344-2008, GB/T 10808-2006, ISO 1798:1997 |
| Protection | Dual-limit (mechanical + programmable), overload cutoff at 110% FS |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HMYX-2000 |
| Testing Speed | 100 mm/min |
| Force Range | 0–2000.0 N |
| Force Resolution | 0.25 N |
| Measurement Accuracy | < ±1% FS |
| Compliance Standards | GB/T 10807-2006, GB/T 10802 |
| Load Cell Type | 200 kg S-type load cell |
| Control Interface | PCI-based computer control card |
| Data Output | Real-time force–displacement curve, printable report |
| Brand | Beiguang Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HMYX-200 |
| Test Speed | 100 mm/min |
| Force Measurement Range | 0–2000.0 N |
| Force Resolution | 0.25 N |
| Measurement Accuracy | < ±1% FS |
| Compliance Standards | GB/T 10807–2006, GB/T 10802–2006 |