BINDER
Filter
Showing 31–60 of 70 results
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FDL |
| Instrument Type | High-Temperature Safety Drying Oven |
| Temperature Range | 10 °C above ambient to 300 °C |
| Temperature Uniformity (at 150 °C) | ±2.5 K |
| Temperature Fluctuation | ±0.8 K |
| External Dimensions | 830 mm × 805 mm × 685 mm |
| Internal Volume | 115 L |
| Internal Chamber Material | Stainless Steel (Si-free, dust-free) |
| Fresh Air Filtration | Replaceable M6-class filter |
| Door Seal | FKM (standard, ≤200 °C) or Silicone (optional, ≤300 °C) |
| Safety Compliance | DIN EN 1539:2010-08, DIN 12880 Class 2 |
| Controller | Programmable with interval & real-time scheduling |
| Interface | RS422 |
| Alarm System | Acoustic & optical fresh-air monitoring + automatic heating cutoff |
| Insulation Thickness | 60 mm |
| Shelf Capacity | 2 standard chrome-plated shelves (max. 30 kg each), up to 5 optional |
| Recovery Time (150 °C, 30 s door open) | 12 min |
| Heating Time to 150 °C | 20 min |
| Rated Power (230 V) | 2.9 kW |
| Net Weight (empty) | 90 kg |
| Max. Load Capacity | 60 kg |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FDL |
| Internal Volume | 115 L |
| Temperature Range | Ambient +10 °C to 300 °C |
| Temperature Uniformity at 150 °C | ±2.5 K |
| Temperature Fluctuation | ±0.8 K |
| Heating Time to 150 °C | 20 min 30 sec |
| Recovery Time after 30-sec Door Opening at 150 °C | 12 min |
| Rated Power (230 V) | 2.9 kW |
| Net Weight (empty) | 90 kg |
| Max. Total Load | 60 kg |
| Max. Load per Shelf | 30 kg |
| Standard Shelves | 2 (up to 5 optional) |
| Fresh Air Filter Class | M6 |
| Door Seal Material (standard) | FKM (solvent-resistant, ≤200 °C) |
| Optional Seal | Silicone (solvent-limited, ≤300 °C) |
| Safety Compliance | EN 1539:2010-08 |
| Independent Temperature Safety Device | DIN 12880 Class 2 |
| Controller | Programmable with Interval & Real-time Scheduling |
| Interface | RS 422 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FED56 / FED115 / FED260 / FED720 |
| Temperature Range | Ambient +10 °C to 300 °C |
| Interior Volume | 60 L to 741 L |
| Temperature Uniformity at 150 °C | ±0.3 K to ±2.0 K |
| Heating Time to 150 °C | 15–30 min |
| Recovery Time after Door Opening (at 150 °C) | 4–6 min |
| Max Load Capacity | 70–315 kg |
| Shelf Load Capacity | 30–45 kg per shelf |
| Power Supply | 230 V (1.1–2.3 kW) / 400 V (4.5 kW) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FED400 |
| External Dimensions (W×H×D, mm) | 1235 × 1025 × 765 |
| Internal Dimensions (W×H×D, mm) | 1000 × 800 × 510 |
| Internal Volume | 400 L |
| Net Weight (empty) | 145 kg |
| Max. Total Load | 90 kg |
| Max. Load per Shelf | 35 kg |
| Temperature Range | Ambient +5 °C to 300 °C |
| Temperature Uniformity at 150 °C | ±3.8 K |
| Temperature Fluctuation at 150 °C | ±0.7 K |
| Heating Time to 150 °C | 29 min 30 s |
| Recovery Time after 30-sec Door Opening at 150 °C | 6 min |
| Rated Power (208 V / 400 V) | 3.4 kW |
| Shelf Quantity (standard / max) | 2 / 10 |
| Fan Speed | Adjustable |
| Exhaust Valve | Continuously Adjustable |
| Controller | Advanced Timer Functionality with Optical Overtemperature Alarm |
| Safety | Dual-stage Independent Temperature Limitation (DIN 12880 Class 2) |
| Interface | RS 422 |
| Insulation | High-efficiency Mineral Wool |
| Shelves | 2 Chrome-plated, Height-adjustable |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | FP53 / FP115 / FP240 / FP400 / FP720 |
| Temperature Range | 5 °C to 300 °C |
| External Dimensions (W×H×D) | 1035 × 825 × 745 mm (FP240) |
| Internal Dimensions (W×H×D) | 800 × 600 × 510 mm (FP240) |
| Chamber Material | Stainless Steel |
| Internal Volume | 53–720 L |
| Net Weight (empty) | 44–194 kg |
| Max. Load Capacity | 40–120 kg |
| Shelf Load Capacity | 15–45 kg per shelf |
| Temp. Uniformity at 150 °C | ±1.8–±2.5 K |
| Temp. Stability at 150 °C | ±0.3 K |
| Heating Time to 150 °C | 24–39 min |
| Recovery Time (150 °C, 30-sec door opening) | 5–20 min |
| Rated Power (230 V) | 1.2–2.7 kW |
| Rated Power (400 V) | 3.45 kW |
| Fan Speed | Adjustable |
| Safety Classes | DIN 12880 Class 2 & Class 3.1 |
| Interface | Ethernet |
| Data Logging | Internal, USB exportable (CSV format) |
| Shelves | 2–16 chrome-plated, removable |
| Door Handle | Ergonomic design |
| Exhaust Valve | Motorized, adjustable |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KB PRO / KBF / KBF PRO with ICH or ICH-LQC Illumination Modules |
| Temperature Range (No Humidity Control) | +18°C to +32°C |
| Temperature & Humidity Range (KBF Series) | +20°C to +50°C / 20–50% RH |
| Extended Temp/Humidity Range (KBF PRO Series) | +10°C to +50°C / 10–80% RH |
| Compliance | ICH Q1B Option 2 (Visible Light) and UV Supplement via Fluorescent Lamps |
| Illumination Types | LED (visible spectrum) + T8 Fluorescent (UV-A/UV-B) |
| Optional Light Dose Control (LQC) | Yes |
| Chamber Volumes | 260 L, 470 L, 720 L |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB ECO 240 / KB ECO 400 / KB ECO 720 / KB ECO 1020 |
| Temperature Range | 0–70 °C (up to 28 K below ambient) |
| Temp. Uniformity at 37 °C | ±0.1 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 40 °C | 350–500 W |
| Recovery Time (30 s door open, 37 °C) | 3–6 min |
| Rated Power | 1.2 kW |
| Internal Volume | 247–1020 L |
| Net Weight | 152–327 kg |
| Max. Load per Shelf | 30–45 kg |
| Max. Total Load | 100–150 kg |
| Wall Clearance (rear/side) | 100 mm |
| External Dimensions (W×H×D) | 925×1461×796 mm to 1250×1925×1149 mm |
| Internal Dimensions (W×H×D) | 650×785×485 mm to 973×1250×836 mm |
| Shelf Capacity (standard/max) | 2/9 to 2/15 |
| Sound Pressure Level | 43–47 dB(A) |
| Energy Consumption at 37 °C | 65–105 Wh/h |
| Interface | Ethernet, USB |
| Display | LCD with alarm and data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Volumes | 260 L, 470 L, 720 L, 1060 L, 1600 L |
| Temperature Range (KB PRO) | 0 °C to +50 °C (no humidity control) |
| Temperature Range (KBF) | 10 °C to +50 °C, Humidity Range: 10–50 % RH |
| Temperature Range (KBF PRO) | 10 °C to +50 °C, Humidity Range: 10–90 % RH |
| LED System | 16 modular strips, each with independently controllable warm white (3000 K), cool white (6500 K), and deep red (660 nm) channels |
| PAR Irradiance | Up to 1000 µmol·m⁻²·s⁻¹ (simulating full sunlight) |
| Control Interface | Touch-enabled external controller with programmable light recipes, twilight simulation, and fresh-air exchange mode |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (safety), and compatible with GLP/GMP documentation workflows |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB PRO Series |
| Temperature Range | –20 °C to +100 °C |
| Temp. Uniformity at 37 °C | ±0.2 K |
| Temp. Stability at 37 °C | ±0.1 K |
| Max. Heat Compensation at 37 °C | 450–1000 W |
| Recovery Time (30 s door opening, 37 °C) | 2–6 min |
| Internal Volume | 127–1610 L |
| Power Supply | 208–240 V, 50/60 Hz |
| Rated Power | 1.0–1.8 kW |
| Net Weight | 135–443 kg |
| Noise Level (25 °C) | 46–52 dB(A) |
| Refrigerant | R-290 |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB Series |
| Temperature Range | 0 °C to +70 °C |
| Temperature Uniformity at 37 °C | ±0.2 K |
| Temperature Fluctuation at 37 °C | ±0.1 K (KB 130 and larger) |
| Recovery Time after 30-sec Door Opening at 37 °C | 3 min |
| Internal Volume | 63 L to 1070 L |
| Power Consumption | 0.9 kW to 1.5 kW |
| Refrigerant | R-600a |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Manufacturer | BINDER GmbH |
| Type | Imported |
| Model | KB 1060 |
| Cooling Method | Compressor-based refrigeration |
| Heating Method | Water-jacketed heating |
| Temperature Range | 0 °C to +70 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C at 37 °C |
| Chamber Volume | 1070 L |
| External Dimensions (W×H×D) | 1285 mm × 1951 mm × 1175 mm |
| Refrigerant | R-600a |
| Insulation | HIT multi-layer jacket technology |
| Interior | Electropolished stainless steel (AISI 304) |
| Inner Door | Safety glass with metal oxide coating |
| Shelving | 2 adjustable stainless steel shelves |
| Data Interface | Ethernet, USB |
| Compliance | DIN 12880 Class 3.3 temperature safety device, GLP-compliant data logging |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KB 115 |
| Temperature Range | –10 °C to 100 °C |
| Internal Volume | 115 L |
| External Dimensions (W×H×D) | 834×1022×646 mm |
| Interior Dimensions (W×H×D) | 600×480×400 mm |
| Temperature Uniformity @ 5 °C | ±0.4 °C |
| @ 25 °C | ±0.1 °C |
| @ 40 °C | ±0.2 °C |
| Temperature Fluctuation @ 5 °C | ±0.1 °C |
| @ 40 °C | ±0.1 °C |
| Heating Time to 40 °C | 9 min |
| Cooling Time from 40 °C to 5 °C | 83 min |
| Recovery Time (30-s door opening) to 5 °C | 5 min |
| to 40 °C | 1 min |
| Power Supply | 230 V, 0.46 kW |
| Net Weight | 105 kg |
| Refrigerant | R134a |
| Shelf Load Capacity | 20 kg per shelf / 50 kg total |
| Shelves | 2 stainless steel standard shelves (up to 5 optional) |
| Door | 1 external door + 1 internal tempered glass door |
| Controller | MP programmable controller (2×10 or 1×20 segments), ramp function, timer functions (delay start/stop, temperature-dependent stop) |
| Fan Speed | 0–100% adjustable |
| Safety Device | Independent Class 3.1 overtemperature protection (DIN 12880) with visual and audible alarm |
| Interface | RS422 for APT-COM® software integration |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KB23 / KB53 / KB115 / KB240 / KB400 / KB720 |
| Temperature Range | −10 °C to 100 °C (KB23: 0 °C to 100 °C) |
| Refrigerant | R134a |
| Control Precision | ±0.1 °C |
| Safety Class | DIN 12880 Class 3.1 |
| Programmable Controller | MP series, 2×10-segment or 1×20-segment programs |
| Communication Interface | RS422 (APT-COM® compatible) |
| Fan Speed | 0–100% adjustable |
| Interior Door | Tempered glass |
| Shelving | 2 stainless-steel shelves |
| Timer Functions | Delayed start/stop, temperature-dependent shutdown |
| Ramp Function Editing | Supported |
| Printer Output | RS232/RS422 converter optional |
| Compliance | CE, ISO 13485 (manufacturer), GLP/GMP-ready architecture |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF PRO |
| Temperature Range | −20 to 100 °C |
| Humidity Range | 10–98 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.2 K (KBF PRO 130 & 260), ±0.3 K (KBF PRO 470–1600) |
| Temp. Stability (25 °C / 60 % RH) | ±0.1 K |
| Humidity Stability (25 °C / 60 % RH) | ±1 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1 min |
| Recovery Time (40 °C / 75 % RH, 30 s door open) | 3–5 min |
| Internal Volume | 127–1610 L |
| Power Consumption | 1.6–1.9 kW |
| Refrigerant | R-290 (eco-friendly hydrocarbon) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF Series |
| Type | Benchtop Environmental Test Chamber |
| Temperature Range | 0–70 °C |
| Humidity Range | 10–80 % RH |
| Temp. Uniformity (25 °C / 60 % RH) | ±0.1–0.4 K |
| Humidity Stability (25 °C / 60 % RH) | ±1.5 % RH |
| Recovery Time (25 °C / 60 % RH, 30 s door open) | 1–3 min |
| Power Consumption | 1.3–1.7 kW |
| Internal Volume | 127–1610 L |
| Refrigerant | R-600a |
| Compliance | DIN 12880, ICH Q1–Q5, GLP/GMP-ready |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KBF-S ECO Solid.Line |
| Temperature Range (with Humidification) | 0 °C to +70 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity (25 °C / 60 % RH) | ±0.1 K |
| Temperature Fluctuation (40 °C / 75 % RH) | ±0.1 K |
| Humidity Fluctuation (40 °C / 75 % RH) | ±0.3 % RH |
| Recovery Time after 30-sec Door Opening (40 °C / 75 % RH) | 11–17 min |
| Internal Volume Options | 247 L, 400 L, 700 L, 1020 L |
| Power Consumption (25 °C / 60 % RH) | 55–90 Wh/h |
| Noise Level | 45–49 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KBF, KBF ICH, KBF LQC, KMF |
| Temperature Range (dry) | 0–70 °C |
| Temperature Range (humidified) | 10–70 °C |
| Humidity Range | 10–80 % RH |
| Control System | MCS controller with 25 stored programs (up to 100 segments each, max. 500 total segments) |
| Humidity Sensor | Capacitive |
| Safety Class | DIN 12880 Class 3.1 |
| Connectivity | Ethernet interface for APT-COM™ software |
| Compliance | ICH Q1A, Q1B Option 2 (KBF LQC), ISO 17025-supportive validation documentation available |
| Accessories | 2 stainless-steel shelves, integrated water supply & drain kit (6 m total length), 30 mm port with silicone plug, double-glazed inner door with hermetic seal |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Chamber Type | Upright |
| Model Families | KBF, KBF P, KBF LQC, KMF |
| Temperature Range (dry) | 0–70 °C |
| Temperature Range (humidified) | 10–70 °C |
| Humidity Range | 10–80 % RH |
| Brand | BINDER |
|---|---|
| Origin | Germany (Manufactured under BINDER quality standards |
| Model | KBF115 |
| Instrument Type | Upright Environmental Test Chamber |
| Temperature Range (with humidity control) | 10–90 °C |
| Humidity Range | 10–90 % RH |
| Temperature Uniformity (at 37 °C, with humidity) | ±1.0 °C |
| Temperature Fluctuation (heating mode) | ±0.1 °C |
| Humidity Fluctuation | ±1.5 % RH |
| Heating Rate to 37 °C | 23 min |
| Cooling Rate from RT to 10 °C | 35 min |
| Recovery Time (30 s door opening, back to 37 °C) | 5 min |
| Internal Volume | 115 L |
| Internal Dimensions (W×H×D) | 600×480×400 mm |
| Stainless Steel Shelves (standard) | 2 pcs (20 kg load per shelf) |
| Refrigerant | R134a |
| Safety Class | Independent temperature safety device Class 3.1 (DIN 12880) |
| Controller | MCS microprocessor-based controller with 25 programmable protocols (100 segments each, max. 500 total segments) |
| Interface | RS422 for APT-COM® data logging and remote monitoring |
| Humidity Sensor | Capacitive, maintenance-free |
| Humidification | Electrode-type, compatible with tap water (conductivity 200–500 µS/cm) |
| Defrost System | Automatic, designed for continuous long-term operation |
| Door | Single, double-glazed internal glass door with condensate collection tray |
| Inlet Port | 30 mm silicone-sealed access port (right side) |
| Power Supply | 230 V ±10 %, 50/60 Hz, 1.7 kW |
| Net Weight | 115 kg |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | KBW, KBWF |
| Temperature Range | 0–70 °C (dry, dark) / 10–60 °C (humid, lit) |
| Humidity Range | 10–80 % RH (dry, dark) / 10–75 % RH (humid, lit) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | KT53 / KT115 / KT170 |
| Temperature Range | 4 °C to 100 °C |
| Internal Volume | 53 L / 102 L / 163 L |
| External Dimensions (W×H×D, mm) | 660×635×630 / 860×715×655 / 860×1025×655 |
| Internal Dimensions (W×H×D, mm) | 400×400×334 / 600×455×355 / 600×765×355 |
| Net Weight | 63 kg / 83 kg / 102 kg |
| Inner Door | Tempered Safety Glass (ESG) |
| Interior | Stainless Steel Construction |
| Shelving | 2 Removable Stainless Steel Trays |
| Stacking Capability | Up to KT115 Units |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 240 |
| Temperature Range | −40 °C to +110 °C (extendable to +120 °C with dual safety cut-off) |
| Temperature Uniformity | ±0.1 K to ±1.2 K (dependent on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K |
| Heating Rate (IEC 60068-3-5) | 5 K/min |
| Cooling Time (110 °C → −40 °C) | 160 min |
| Average Cooling Rate (IEC 60068-3-5) | 3.5 K/min |
| Thermal Compensation at 25 °C | 3000 W |
| Rated Voltage | 400 V or 480 V AC, 3~ |
| Frequency | 50/60 Hz |
| Nominal Power | 5.6 kW |
| Fuse Rating | 16 A |
| Internal Volume | 228 L |
| Net Weight (empty) | 375 kg |
| Max. Load Capacity | 70 kg |
| Shelf Load per Rack | 30 kg |
| Viewing Window | 508 mm × 300 mm (heated, LED-lit) |
| Internal Dimensions (W×H×D) | 735 mm × 700 mm × 443 mm |
| External Dimensions (W×H×D) | 1335 mm × 1929 mm × 925 mm |
| Rear Clearance | 300 mm |
| Side Clearance | 200 mm |
| Sound Pressure Level | 62 dB(A) |
| Safety Systems | Dual independent Class 2 temperature cut-offs (DIN 12880), CO/H₂/O₂/temperature gas monitoring, CO₂ fire suppression, reinforced door lock, reversible stainless-steel pressure relief valve, APT.line™ pre-heating chamber, condensation protection programming, fluorine-free refrigerant R-452A |
| Control Interface | Touchscreen controller with time-segment & real-time programming, APT-COM™ Basic software, Ethernet interface, USB data export (open CSV format), internal datalogger, 230 V socket on right-side panel |
| Standard Equipment | 1 stainless-steel shelf, compressed-air-cooled refrigeration unit |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | LIT MK 720 |
| Temperature Range | –40 °C to +110 °C |
| Temperature Uniformity (±K) | 0.1–0.5 |
| Temperature Stability (±K) | 0.3–2.0 |
| Avg. Heating Rate (IEC 60068-3-5) | 4 K/min |
| Avg. Cooling Rate (IEC 60068-3-5) | 3.4 K/min |
| Internal Volume | 734 L |
| Max. Load Capacity | 160 kg |
| Net Weight | 570 kg (LIT MK 720-400V) / 522 kg (LIT MK 720-480V-C) |
| Power Supply | 400 V, 3~ |
| Refrigerant | R-452A |
| Sound Pressure Level | 65–67 dB(A) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | M53 / M115 / M240 / M400 / M720 |
| Temperature Range | Ambient +5 °C to 300 °C |
| Internal Volume | 53–720 L |
| External Dimensions (W×H×D) | 1235 mm × 1690 mm × 865 mm |
| Internal Dimensions (W×H×D) | 1000 mm × 1200 mm × 610 mm |
| Heating Method | Forced Convection (Hot Air) |
| Temperature Uniformity at 150 °C | ±1.3–1.9 K |
| Temperature Fluctuation at 150 °C | ±0.3 K |
| Heating Time to 150 °C | 15–21 min |
| Recovery Time after 30-sec Door Opening at 150 °C | ≤3 min |
| Max. Load Capacity | 40–120 kg |
| Max. Shelf Load | 15–45 kg |
| Standard Shelves | 2 (adjustable), Max. Shelves: 5–16 |
| Power Rating (230 V) | 1.2–2.7 kW |
| Power Rating (400 V) | 3.45 kW |
| Interface | Ethernet, USB for Data Logger Export |
| Safety | Dual Independent Temperature Safety Devices (DIN 12880 Class 2 & Class 3.1), Redundant Pt100 Sensor |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | M, MK, MKT |
| Application Scope | Thermal Stress Testing, Stability & Durability Evaluation, Material Aging (per EN 60811-1-2 / IEC 60811-1-2) |
| Compliance | ISO 17025-accredited laboratory use, GLP/GMP-compatible operation, FDA 21 CFR Part 11-ready software options available |
| Cooling Method | Dual-circuit refrigeration with cascade system (for MKT series down to –70 °C) |
| Temperature Range | –70 °C to +180 °C (MKT), –40 °C to +180 °C (MK), –20 °C to +180 °C (M) |
| Uniformity | ±0.3 °C (at 100 °C, load-free) |
| Control System | BINDER CTC Advanced Touchscreen Controller with programmable ramp/soak profiles, real-time data logging, and Ethernet interface |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MDL |
| External Dimensions (L×H×W) | 834×800×685 mm |
| Internal Dimensions (L×H×W) | 600×435×435 mm |
| Temperature Range | +5 °C above ambient to 350 °C |
| Internal Volume | 115 L |
| Temperature Uniformity | ≤ ±0.5 °C |
| Airflow Rate | 400 L/min |
| Heating Power | 9.0 kW |
| Safety Class | Dual independent temperature safety device (DIN 12880, Class 2) |
| Fresh Air Filter | EU6 (F6), particle retention ≥1 µm |
| Rear Exhaust Port | Ø100 mm |
| Shelves | 2 chrome-plated adjustable shelves |
| Controller | MCS microprocessor-based controller with 25 stored programs, 100 segments per program, up to 500 total segments |
| Display | User-friendly LCD with intuitive menu navigation |
| Data Logging | Built-in electronic chart recorder with multiple real-time graphical display options |
| Real-Time Clock | Integrated |
| Ramp Function | Programmable via on-board editor |
| Door Seal | High-temperature silicone gasket |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MK Series |
| Temperature Range | –40 °C to +180 °C |
| Internal Volume | 56–1020 L |
| Temperature Uniformity | ±0.1 K to ±2.0 K (depends on setpoint) |
| Temperature Stability | ±0.1 K to ±0.5 K (depends on setpoint) |
| Heating Rate (IEC 60068-3-5) | up to 5.5 K/min |
| Cooling Rate (IEC 60068-3-5) | up to 4.5 K/min |
| Refrigerant | R-452A (non-ozone-depleting) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MK |
| Temperature Range (Standard) | −40 °C to +180 °C |
| Temperature Range (Low-Temp Variant, MKT/MKFT) | −70 °C to +180 °C |
| Humidity Range (MKF/MKFT) | 10 %RH to 98 %RH |
| Humidity-Enabled Temp Range | +10 °C to +95 °C |
| Available Interior Volumes | 53 L, 115 L, 240 L, 720 L |
| Control System | MCSE microprocessor controller with APT.line® preheating technology |
| Programmability | 25 stored programs, up to 100 segments per program (max. 500 total segments) |
| Interface Options | Ethernet or RS-422 (APT-COM software compatible) |
| Safety | Dual-stage temperature safety device (DIN 12880), audible/visual alarm |
| Refrigerant | R404A (environmentally compliant) |
| Standard Accessories | 1 stainless steel shelf, heated observation window with interior lighting, built-in electronic chart recorder, condensation protection for test specimens |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model | MKF Series |
| Temperature Range | −70 °C to +180 °C (−94 °F to +356 °F) |
| Humidity Range | 10–90 % RH (MKF 240 only) |
| Internal Volume | 228–734 L |
| Temperature Uniformity | ±0.1–±1.0 K |
| Temperature Stability | ±0.1–±0.5 K |
| Heating Rate (−40 °C → 180 °C) | 1.1–5.5 min |
| Cooling Rate (180 °C → −40 °C) | 0.6–5.2 min |
| Refrigerant | R404a |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, GLP/GMP, FDA 21 CFR Part 11 (via APT-COM) |
| Brand | BINDER |
|---|---|
| Origin | Germany |
| Model Series | MKF / MK / MKT |
| Internal Volume Options | 53 L, 115 L, 240 L, 400 L, 720 L |
| Temperature Range | MK/MKF: −40 °C to +180 °C |
| MKT | −70 °C to +180 °C |
| M-Series | +5 °C above ambient to +300 °C |
| Humidity Range (MKF only) | 10–98 % rH |
| Control System | MB1 4-channel touchscreen controller (25 programs × 100 segments) |
| Cooling Technology | DCT® Direct Cooling Technology |
| Preconditioning Chamber | APT-Line® |
| Air Circulation | Digitally adjustable high-power turbine |
| Compliance | DIN EN 60068-3-5, IEC 60068-3-6, ISO 16750-4, ASTM D4329, USP <1151> (environmental stress testing), GLP-compliant data logging via APT-COM software |
| Interface | RS422 for APT-COM v3.x integration |
| Insulation | High-efficiency vacuum-insulated door & polyurethane foam walls |