Countstar
Filter
Showing all 14 results
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | AItair |
| Detection Time | 150 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IY1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IE1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IA1000 |
| Analysis Time | <20 s |
| Detection Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IM1200 |
| Detection Time | <20 s |
| Cell Concentration Range | 5×10⁴–5×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | IC1000 |
| Measurement Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per slide |
| Detectable Cell Diameter | 5–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Castor X |
| Fluorescence Channels | Dual (Green & Red) |
| Compatible Vessels | 6/12/24/96/384-well plates, Petri dishes, culture flasks |
| Imaging Sensor | Cooled high-resolution monochrome CMOS camera |
| Analysis Engine | AI-powered deep learning algorithms for clonal identification, confluency quantification, and transfection efficiency scoring |
| Software | Modular, GLP-compliant with audit trail and user permission management |
| Regulatory Alignment | Designed to support ISO 13485 workflows and FDA 21 CFR Part 11–ready data integrity practices |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira BF |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 2 – 180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL |
| Detection Time | 20–50 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 1–180 µm |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Plus |
| Measurement Time | 20–50 s |
| Cell Concentration Range | 1×10⁴ – 3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Size Range | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Enhanced via fixed-focus optical architecture |
| Fluorescence Channels | AO/PI, GFP, RFP |
| Compliance | FDA 21 CFR Part 11, GMP-aligned data integrity framework |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira FL Pro |
| Detection Time | 20–50 s |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Optical Magnification | 10× |
| Imaging Sensor | 8.3 MP CMOS |
| Compatible Consumables | Standard Countstar counting chambers & newly developed 60-µm-depth chambers |
| Regulatory Compliance | FDA 21 CFR Part 11, GMP-aligned |
| Validation Support | Full 3Q (IQ/OQ/PQ) documentation available |
| Data Management | Audit trail, user access control, server & printer integration |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Mira HT |
| Detection Concentration Range | 1 × 10⁴ – 3 × 10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 24 samples (standard) / 15 samples (fluorescence mode) |
| Detectable Cell Size | 1–180 µm |
| Imaging Sensor | 8.3 MP CMOS |
| Optical Resolution | Optimized for ≥2× field area vs. standard hemocytometer |
| Trypan Blue Mode Acquisition Time | <10 s per image |
| AO/PI Dual-Fluorescence Mode Acquisition Time | <22 s per image |
| Total Analysis Time per Sample | <30 s (brightfield), <60 s (fluorescence) |
| Software Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail, 3Q validation support |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Rigel |
| Detection Time | <20 s |
| Cell Concentration Range | 1×10⁴–3×10⁷ cells/mL |
| Sample Volume | 20 µL |
| Throughput | 5 samples per run |
| Detectable Cell Diameter | 3–180 µm |
| Fluorescence Channels | Up to 13 (4 excitation sources + 5 emission filter combinations) |
| Regulatory Compliance | CE-marked, FDA 21 CFR Part 11–compliant software architecture |
| Intended Use | Research use only (RUO), not for diagnostic purposes |
| Brand | Countstar |
|---|---|
| Origin | Shanghai, China |
| Model | Countstar Spica |
| Type | Label-Free Live-Cell Imaging System |
| Optical Configurations | Spica M1 (7.5×/10×/15× |
| 3-channel fluorescence | DAPI/GFP/RFP |
| 4-channel fluorescence | DAPI/GFP/RFP/APC |
| Environmental Integration | Incubator-compatible (37 °C, 5% CO₂, humidity control) |
| Software | AI-powered analysis platform with ≥12 pre-validated application modules, FDA 21 CFR Part 11–compliant audit trail (optional), GLP/GMP-ready data export (CSV, TIFF, JSON, PDF) |