DLAB
Filter
Showing 241–258 of 258 results
| Brand | DLAB |
|---|---|
| Model | TB-H240-V1 |
| Type | Heating Bath Circulator |
| Temperature Range | 25–240°C |
| Temperature Resolution | 0.1°C |
| Temperature Stability | ±0.5°C (at setpoint) |
| Over-Temperature Cutoff | 280°C |
| Input Power | 360 W |
| Heat Output | 350 W |
| Voltage/Frequency | 100–120 V or 200–240 V, 50/60 Hz |
| Bath Chamber Dimensions | Ø150 × 100 mm |
| External PT1000 Sensor Port | Yes |
| IP Rating | IP21 |
| Net Weight | 2.2 kg |
| Overall Dimensions (L×W×H) | 310 × 220 × 135 mm |
| Operating Environment | 5–40°C, ≤80% RH |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96-well format (0.2 mL tubes, 8×12 strips, or full 96-well plates) |
| Temperature Range | 4–105°C (sample block), 30–110°C (heated lid) |
| Temperature Accuracy | ±0.3°C at 55°C |
| Temperature Uniformity | <0.3°C at 55°C |
| Max Ramp Rate | 5°C/sec |
| Gradient Range | 30–99°C |
| Gradient Span | 1–42°C |
| Block Material | Anodized aluminum |
| Display | 7-inch color TFT-LCD (800×480 resolution) |
| Control Interface | Capacitive touch screen |
| Program Storage | 16 folders × 16 programs/folder |
| Power Input | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 280 × 370 × 250 mm |
| Weight | 11 kg |
| Power Failure Protection | Yes |
| Temperature Display Resolution | ±0.1°C |
| Brand | DLAB |
|---|---|
| Model | TC1000-G-Pro |
| Instrument Type | Gradient PCR Thermal Cycler |
| Sample Capacity | 96 × 0.2 mL tubes / 12 × 0.2 mL strips / 0.2 mL 96-well plates |
| Block Temperature Range | 0–105 °C |
| Heat Lid Temperature Range | 30–115 °C |
| Temperature Display Accuracy | ±0.1 °C |
| Temperature Control Accuracy (at 55 °C) | ±0.1 °C |
| Temperature Uniformity (at 55 °C) | ±0.2 °C |
| Max Ramp Rate | 5 °C/sec |
| Gradient Range | 30–105 °C |
| Gradient Span | 1–42 °C |
| Temperature Control Mode | Block- or Tube-based |
| Block Material | Anodized Aluminum |
| Display | 7″ LCD (1024 × 600) |
| Input Method | Touchscreen + PC-based host software |
| Communication Interfaces | USB 2.0, Wi-Fi (IEEE 802.11 b/g/n) |
| Power Supply | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 280 × 370 × 250 mm |
| Weight | 9.5 kg |
| Data Retention (Power Loss Recovery) | >20,000 cycles (USB flash memory) |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | TC1000-S |
| Sample Throughput | 96-well format |
| Temperature Accuracy | ±0.3 °C |
| Well-to-Well Temperature Uniformity | <0.3 °C |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | TC1000-S+ |
| Temperature Accuracy | ±0.1°C |
| Temperature Uniformity | ±0.2°C @ 55°C |
| Block Temperature Range | 4–105°C |
| Heat Lid Temperature Range | 30–110°C |
| Temperature Resolution | 0.1°C |
| Max Ramp Rate | 5°C/sec |
| Gradient Span | Programmable |
| Block Material | Aluminum |
| Display | 7-inch LCD (800×480) |
| Input Method | Capacitive Touchscreen |
| Program Capacity | >200 protocols |
| Steps per Protocol | Up to 30 |
| Max Cycles per Protocol | 99 |
| Power Supply | 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (L×W×H) | 296×370×295 mm |
| Weight | 9.5 kg |
| Sample Compatibility | 96×0.2 mL tubes, 12×0.2 mL strip tubes, 0.2 mL 96-well PCR plates |
| Features | Touchdown PCR (±9.9°C offset), Long PCR timing adjustment (±9 min 59 sec), Auto heat lid shutdown (<30°C block temp), power-fail recovery, edge temperature compensation |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | TC2000-G1/G2/G3 |
| Temperature Range | 0–105 °C |
| Heating Rate | 5 °C/s |
| Temperature Accuracy | ±0.1 °C |
| Temperature Uniformity | ±0.2 °C |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer | DLAB Scientific Instruments Co., Ltd. |
| Type | Single-Channel & Multi-Channel Manual Pipette |
| Volume Range | 0.1 µL – 10 mL |
| Accuracy | ±0.3% to ±2.5% (varies by volume and model) |
| Calibration Certifications | ISO 9001:2008 & ISO 13485:2003 |
| Sterilization | Autoclavable (lower assembly only) |
| Chemical Resistance | High resistance to common laboratory solvents and corrosive reagents |
| Serviceability | Fully modular design with tool-assisted field calibration and maintenance |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | TopPette |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | 1 |
| Volume Range | 0.1 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.5% |
| Sterilization | Autoclavable (lower body only) |
| Chemical Resistance | High |
| Serviceability | Fully Serviceable with Tool-Assisted Calibration |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Pipette Type | Manual Single-Channel |
| Volume Range | 100–1000 µL |
| Maximum Capacity | 1000 µL |
| Accuracy | ±6 µL (±0.6%) |
| Precision | ±0.2% |
| Tip Compatibility | Standard Conical 1000 µL Tips |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Adjustable Volume | Yes |
| Volume Lock | Integrated |
| Weight | <120 g |
| Material | Chemically Resistant Polypropylene & Stainless Steel Components |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 50–200 µL |
| Volume Range | 50–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±2.5% |
| Precision (CV) | ±0.15% |
| Operating Principle | Air-displacement positive displacement |
| Channel Configuration | Single-channel |
| Automation Level | Manual |
| Tip Compatibility | Standard conical 300 µL universal pipette tips |
| Sterilization | Autoclavable (121 °C, 20 min, fully assembled) |
| Tip Ejector | Integrated lightweight push-button ejector |
| Calibration | Tool-assisted field calibration compliant with ISO 8655-2 |
| Regulatory Compliance | Designed to support GLP/GMP workflows and ISO/IEC 17025 traceability requirements |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Pipette Type | Single-channel manual pipette |
| Volume Range | 10–100 µL |
| Accuracy | ±0.8% |
| Precision (CV) | ±0.15% |
| Increment | 1 µL |
| Tip Compatibility | Standard conical 300 µL universal tips |
| Sterilization | Autoclavable (121°C, 20 min) |
| Weight | ~95 g |
| Ergonomic Design | Full-hand grip, low operating force, fatigue-reducing actuation |
| Calibration | Tool-assisted, ISO 8655-compliant adjustment |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Pipette Type | Single-channel manual pipette |
| Channel Count | 1 |
| Volume Range | 0.1–2.5 µL |
| Maximum Capacity | 2.5 µL |
| Accuracy | ±2.5% |
| Precision (CV) | ±2.0% |
| Tip Compatibility | 10 µL low-retention filtered tips |
| Sterilization | Autoclavable (121°C, 20 min) |
| Weight | ~85 g |
| Ergonomic Design | Full-hand grip with thumb rest and textured surface |
| Volume Adjustment | Rotating volume selector with digital window display |
| Calibration | Tool-assisted in-field calibration |
| Filter Tip Adapter | Replaceable hydrophobic filter integrated into tip cone |
| Tip Ejector | Spring-assisted, low-force ejection mechanism |
| Tip Cone Material | Chemically resistant PTFE-coated stainless steel |
| Volume Lock | Mechanical lock to prevent accidental volume change |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 20–200 µL |
| Volume Range | 20–200 µL |
| Maximum Capacity | 200 µL |
| Accuracy | ±2.5% |
| Precision (CV) | ±0.15% |
| Operating Principle | Air-displacement |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Tip Compatibility | Standard conical universal pipette tips (300 µL) |
| Ergonomic Design | Full-hand grip, low actuation force, rotatable volume dial, lockable volume setting |
| Serviceability | Modular tip cone assembly, tool-free calibration access, replaceable filter barrier |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 0.5–10 µL |
| Volume Range | 0.5–10 µL |
| Maximum Capacity | 10 µL |
| Accuracy | ±2.5% |
| Precision (CV) | ±2.0% |
| Increment | 0.1 µL |
| Pipette Type | Manual Single-Channel |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Tip Compatibility | Standard 10 µL universal pipette tips |
| Tip Ejector | Integrated lightweight push-button ejector |
| Calibration | Tool-assisted field calibration supported |
| Ergonomics | Low-force plunger activation, contoured grip, balanced weight distribution |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 5–50 µL |
| Volume Range | 5–50 µL |
| Maximum Capacity | 50 µL |
| Accuracy | ±2.5% |
| Precision (CV) | ±0.3% |
| Increment | 0.5 µL |
| Pipette Type | Manual Single-Channel |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Tip Compatibility | Standard conical 300 µL universal tips |
| Tip Ejector | Integrated lightweight push-button ejector |
| Calibration | Tool-assisted field calibration supported |
| Ergonomics | Low-force plunger activation, contoured finger grips, balanced weight distribution |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 100–1000 µL |
| Volume Range | 0.1–5000 µL |
| Accuracy (typical) | ±0.5% to ±2.5% |
| Precision (typical) | ±0.15% to ±2.0% |
| Tip Compatibility | 10 µL, 300 µL, 1000 µL, and 5000 µL sterile filtered tips |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Tip Ejector | Integrated lightweight push-button |
| Calibration | Tool-assisted field calibration supported |
| Ergonomic Design | Low-force plunger activation, contoured finger grips, balanced weight distribution |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Model | 2–20 µL |
| Accuracy (±) | 0.9% |
| Precision (CV) | 0.4% |
| Volume Adjustment Increment | 0.5 µL |
| Tip Compatibility | 300 µL universal low-retention tips |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Regulatory Compliance | ISO 8655-2:2022, GLP-ready design |
| Brand | DLAB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | VC100 |
| Instrument Category | Vacuum Control System |
| Product Type | Oil-Lubricated Vacuum Pump Integrated Controller |
| Maximum Vacuum Level | 1 mbar |
| Vacuum Setpoint & Measurement Range | 1–1000 mbar |
| Control Modes | Single-Point Mode & Programmable Multi-Step Mode |
| Stored Programs | 5 user-defined programs (up to 5 segments per program) |
| Display | 5-inch TFT touch screen |
| Sensor Overpressure Limit | 1500 mbar |
| Gas Inlet Valve | Integrated inert gas purge valve |
| Venting Function | One-touch atmospheric venting |
| Pump Power Control | Auto-on/off relay output (compatible with oil-sealed rotary vane pumps) |
| Wetted Materials | PTFE, ceramic, silicone, polypropylene |
| External Dimensions | 189 × 207 × 193 mm (W × D × H) |
| Weight | 4.0 kg |
| Motor Power Rating | 600 W |
| Input Voltage | 110–240 V AC, 50/60 Hz |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |