| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Fluoride Ion Online Monitor |
| Instrument Type | Fluoride Ion Analyzer |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) |
| Range | 0–20 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max. Suspended Solids | 2% w/w, max. particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE-compliant, designed to meet general requirements for industrial environmental monitoring installations |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Hydrochloric Acid Concentration Analyzer |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Nitrate Online Monitor |
| Instrument Type | Nitrate Ion (NO₃⁻) Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Range Options | 0–10 ppm, 0–50 ppm, 0–100 ppm |
| Accuracy | ±5% of reading or full scale |
| Resolution | 0.001 ppm |
| Repeatability | ±5% of reading or full scale |
| Cycle Time | 2 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4″ compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, max particle size 1.27 mm (0.05″) |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4″ NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Dimensions (W×H×D) | 610 × 640 × 330 mm |
| Weight | ~36 kg (fully assembled) |
| Mounting | Wall-mounted with included hardware |
| Certifications | CE compliant |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Silicon Online Analyzer |
| Instrument Type | Silica (Orthosilicic Acid) Analyzer |
| Measurement Principle | Colorimetric Spectrophotometry (Molybdenum Blue Method) |
| Detection Wavelengths | 810 nm (low-range), 312 nm (high-range) |
| Range Options | 0–100 ppb, 0–500 ppb, 0–1000 ppb, 0–2 ppm, 0–5 ppm, 0–10 ppm |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppb (at lowest range) |
| Repeatability | ±2% of reading or full scale |
| Sample Flow Rate | 50–900 mL/min |
| Sample Interface | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Max Suspended Solids | 2% w/w, particle size ≤ 1.27 mm |
| Sample Pressure | 0–50 psig |
| Drain Outlet | 3/4" NPT male, atmospheric vent |
| Alarm Outputs | User-programmable digital relays |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with integrated hardware |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully assembled) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Sodium Ion Online Monitor |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) with Single Standard Addition (SSA/SKA) Method |
| Range | High Range 0–200 ppm, Low Range 0–200 ppb |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppm/ppb |
| Repeatability | ±2% of reading or full scale |
| Sample Volume | 19 mL |
| Reagent Consumption | 2 mL per analysis |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Suspended Solids | ≤2% w/w, max particle size 0.05" (1.27 mm) |
| Sample Pressure | 0–50 psig |
| Waste Outlet | 3/4" NPT male, open drain |
| Alarm Outputs | User-programmable digital outputs |
| Analog Output | 4–20 mA, fully configurable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted (hardware included) |
| Dimensions (W×H×D) | 387 × 406 × 210 mm |
| Weight | ~36 kg (fully assembled) |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OH⁻ in NaOCl Solution |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Total Manganese Online Monitor |
| Instrument Type | Multi-Ion Analyzer |
| Measurement Principle | Colorimetric Analysis (Formaldehyde Oxime Complexation) |
| Range | Low: 0–25 ppb, High: 0–200 ppb |
| Accuracy | ±2% of reading or full scale |
| Resolution | 0.001 ppb |
| Repeatability | ±2% of reading or full scale |
| Cycle Time | 10 minutes |
| Sample Flow Rate | 50–900 mL/min |
| Sample Inlet | 1/4" compression fitting |
| Sample Temperature | 5–70 °C |
| Suspended Solids | ≤2% w/w, max particle size 1.27 mm |
| Sample Pressure | 0–50 psig |
| Effluent Outlet | 3/4" NPT male, atmospheric discharge |
| Alarm Outputs | User-programmable |
| Analog Output | 4–20 mA, programmable |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting | Wall-mounted with included hardware |
| Dimensions (W×H×D) | 387 mm × 406 mm × 210 mm |
| Weight | ~36 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Sentinel Zinc Ion Online Monitor |
| Pricing | Upon Request |
| Instrument Type | Multi-Ion Analyzer |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | UC-A |
| Price Range | USD 0.14 – 428 |
| Instrument Type | Noise Enclosure for Grinding & Sonication Equipment |
| Noise Reduction | 20 dBA (A-weighted) |
| Perceived Noise Reduction | ~50% |
| Cooling Airflow | 80 m³/h |
| External Dimensions | 700 × 450 × 520 mm (W × D × H) |
| Internal Cavity Dimensions | 600 × 380 × 480 mm (W × D × H) |
| Mass | 40 kg |
| Fire Resistance | UL 94 V-0 compliant flame-retardant acoustic foam lining |
| Thermal Safety | Integrated temperature sensor with audible/visual overtemperature alarm |
| Key Features | AC servo motor drive |
|---|---|
| Test speed | 5–300 mm/min (software-controlled) |
| Stroke | 1000 mm (excluding grips) |
| Dimensions | 985 × 510 × 1600 mm (L×W×H) |
| Power | 220 V, 50/60 Hz |
| Compliance | ASTM D412, D3574, D5035, ISO 37, 1421, 1798, GB/T 16491, GB/T 1040, and over 40 additional international standards |
| Load capacity options | 50, 100, 200, 500, 1000 kg |
| Unit switching | g, kg, N, kN, lbf |
| Software | Real-time curve plotting, peak hold, auto-stop at break, overload protection, data export, customizable reporting |
| Origin | Taiwan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Domestic Product Classification | Yes |
| Model | MK350N Premium |
| Price Range | USD 2,800 – 7,000 |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | URE-2000 Series |
| Price Range | USD 42,000 – 70,000 |
| Scanning Throughput | 2 µm feature resolution |
| Resolution | 0.8 µm (with 2 µm positive photoresist) |
| Detection System Type | UV Optical Detection |
| Excitation Wavelength | 365 nm (i-line) |
| Emission Wavelength | 365 nm |
| Exposure Area | Up to 200 mm × 200 mm (URE-2000/A8) |
| Exposure Time Range | 0.1 s – 9999.9 s (programmable timer) |
| Mercury Lamp Power | 1000 W (DC, Osram Ultra-High-Pressure Hg Lamp) |
| Illumination Uniformity | ≤2.5% (Ø100 mm), ≤5% (Ø200 mm) |
| Alignment Accuracy | ±0.8 µm (single-side), ±2 µm (double-side, 0.8 mm wafer thickness) |
| Maximum Resist Thickness | 500 µm (SU-8, user-provided conditions) |
| Key Specifications | Temperature Range: RT to 85 °C (Operating Range: 50 ±10 °C) |
|---|---|
| Heating Rate | ≤25 min (RT → 85 °C) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Output | 295–450 nm |
| Irradiance | 200 ±8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90 % |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Key Specifications | Temperature Range: RT to 85 °C (operational test range: 50 °C ±10 °C) |
|---|---|
| Humidity Range | 40–70 % RH during irradiation |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Radiation Source | Single 2.5 kW air-cooled metal halide lamp |
| Spectral Output | 295–450 nm, filtered to match terrestrial solar UV + visible irradiance through 3 mm borosilicate glass |
| Sample Tray Dimensions | 500 × 400 mm |
| Key Features | UV Lamp Wavelength Range: 280–400 nm |
|---|---|
| Internal Chamber Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2 °C or ≤ ±3% |
| Humidity During Condensation Cycle | ≥95% RH |
| UV Exposure Time Programmable | 0–999 h |
| Lamp Type | Fluorescent UV Tubes (Avg. Service Life: ~2000 h) |
| Construction Material | SUS#304 Stainless Steel (Interior & Exterior) |
| Heating System | U-shaped Titanium Alloy Fast-Response Heaters |
| Safety Protections | Interlocked UV Shut-off on Door Opening, Over-Temperature Protection, Low-Water Level Cut-off |
| Power Supply | AC 220 ±5 V, 50 ±0.5 Hz |
| Brand | Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Distributor |
| Model | UV-Enhanced Silicon Photodiode |
| Pricing | Upon Request |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UV4E-UV |
| Pricing | Available Upon Request |
| Spectral Range | 200–400 nm |
| Spectral Resolution | 2 nm |
| Effective Slit Length | 9.3 mm |
| Optical Throughput | >50% |
| Relative Aperture | f/2.8 |
| Slit Width | 50 µm |
| Stray Light Level | 0.5% |
| Spectral Band Count | >100 |
| CCD Sensor | 1000 × 1000 pixels |
| A/D Conversion | 12-bit |
| Dynamic Range | 59 dB |
| Full-Frame Frame Rate | >30 fps |
| Binned Frame Rate | 150 fps |
| Interface | Camera Link |
| Lens Mount | C-Mount |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MZ 2C NT |
| Instrument Type | Diaphragm Vacuum Pump |
| Product Type | Oil-Free Vacuum Pump |
| Maximum Flow Rate | 2.0 m³/h |
| Ultimate Vacuum (Absolute) | 7 mbar |
| Ultimate Vacuum with Gas Ballast Enabled | 12 mbar |
| Dimensions (L×W×H) | 243 × 243 × 198 mm |
| Weight | 11.1 kg |
| Ordering Code | 732300 |
| Temperature Range | RT +10°C to 300°C (customizable up to 500°C) |
|---|---|
| Internal Chamber Dimensions | 450 × 400 × 400 mm (W×H×D) |
| External Dimensions | 650 × 900 × 600 mm (W×H×D) |
| Temperature Uniformity | ±1.5°C |
| Control Accuracy | ±0.5°C |
| Heating System | Dual independent 2 kW far-infrared Ni-Cr alloy heaters |
| Sensor | PT100 platinum resistance thermometer |
| Controller | Microprocessor-based digital touch controller with timer (0–999 min) |
| Air Circulation | Forced convection via bottom-mounted blower with left-side air outlet |
| Standard Shelving | 3 stainless steel wire shelves (SUS304) |
| Power Supply | AC220V ±5%, 50 Hz, 2000 W |
| Compliance | GB/T 2423.2 (High-Temperature Test Method B) |
| Safety Features | Leakage current protection, over-temperature alarm & cut-off, thermal fuse backup |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BCNX-AQ05 |
| Pricing | Upon Request |
| Price | USD 21,500 (FOB origin, ex-works) |
|---|---|
| [Key | Value] |
| 台面尺寸 (Tabletop Dimensions) | 350×350 mm |
| 台体尺寸 (Shaker Body Dimensions) | 500×200×500 mm (vertical) / 500×250×500 mm (horizontal) |
| 振动方向 (Vibration Axes) | Vertical (Z) + Horizontal (X) |
| 频率范围 (Frequency Range) | 1–3000 Hz |
| 频率显示精度 (Frequency Resolution) | ±0.01 Hz |
| 振幅范围 (Peak-to-Peak Displacement) | 0–5 mm adjustable |
| 最大负载 (Maximum Payload) | 75 kg |
| 最大激振力 (Maximum Force Output) | 1500 kgf (≈14.7 kN) |
| 最大加速度 (Maximum Acceleration) | ≤20 g |
| 振动波形 (Waveform Options) | Sine (full/half cycle) |
| 时间设� | 范围 (Test Duration): 0–999,999 s (programmable) |
| 额� | 功率 (Rated Power): 3.8 kW |
| 输入电流 (Input Current) | ≤10 A |
| 电源要求 (Supply Voltage) | 380 V ±20%, 3-phase, 50/60 Hz |
| 加速度计算公� | � (Acceleration Formula): a (g) = 0.002 × f² (Hz²) × D (mm p-p) |
| 工作环境温度 (Operating Ambient Temp) | −10 °C to +60 °C |
| 相对湿度 (Relative Humidity) | ≤95% RH (non-condensing) |
| 推荐操作环境 (Recommended Lab Conditions) | ≤28 °C, well-ventilated |
| Origin | Italy |
|---|---|
| Supplier Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M609 TECHINO |
| Pricing | Upon Request |
| Key | Origin: Sweden |
|---|---|
| Type | Imported Instrument |
| Model | VL400 |
| Measurement Principle | Dual-mode (Class 1 Laser / Pulse-Echo Ultrasonic) |
| Dimensions | 95 × 70 × 58 mm |
| Weight | 260 g (incl. battery) |
| Power | 1×CR2 3V lithium battery |
| Power Consumption | 60 mW |
| Operating Temperature | −15 °C to +45 °C |
| Max Height Range | 0–999 m |
| Height Resolution | 0.1 m |
| Angle Range | −55° to +85° |
| Angle Resolution/Accuracy | 0.1° |
| Laser Range (diffuse target) | up to 350 m |
| Laser Range (retroreflective) | 130–900 m |
| Laser Distance Resolution | 0.5 m (<100 m), 1 m (≥100 m) |
| Laser Distance Accuracy | ±0.25 m (<100 m), ±1 m (≥100 m) |
| Ultrasonic Range (60° transducer) | ≥30 m |
| Ultrasonic Range (360° transducer) | ≥20 m |
| Ultrasonic Resolution | 0.01 m |
| Ultrasonic Accuracy | <1% of reading |
| T3 Transponder Dimensions | Ø70 mm |
| T3 Weight | 85 g (incl. AA battery) |
| T3 Power | ≤9 mW |
| Interface | Built-in infrared data port |
| Units | Switchable metric/imperial (distance/height), degree/grade/% (angle) |
| Key | Temperature Range: -60°C to +80°C |
|---|---|
| Humidity Range | 20–98% RH (optional 5–98% RH) |
| Temp. Uniformity | ±0.5°C |
| Temp. Deviation | ±3°C (configurable) |
| Power Supply | AC 380 V, 50 Hz |
| Noise Level | ≤75 dB(A) |
| Construction | Double-skin color-coated steel insulated panels (EPS/polyurethane/rock wool, thickness 50–100 mm) |
| Structural Frame | Galvanized steel framework with aluminum or stainless-steel edging |
| Fire Rating | GB 8624–2012 Class B2 |
| Control System | Microprocessor-based PID + SSR + Timer, PLC-driven, touch-screen HMI |
| Compliance | Designed per ISO 16750-4, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, and ASTM D4332 |
| Key | Temperature Range: -60°C to 100°C (selectable variants: -35°C/–20°C to 100°C) |
|---|---|
| Humidity Range | 15–95% RH |
| Temperature Stability | ±0.5°C |
| Humidity Stability | ±2% RH |
| Temperature Uniformity | ±2°C |
| Humidity Uniformity | ±3% RH |
| Temperature/Humidity Deviation | ≤±2°C / ≤±3% RH |
| Refrigerant | HFC-404A & HFC-23 (zero ozone depletion potential) |
| Construction | Modular PU-insulated panels |
| Inner Chamber | SUS304 stainless steel |
| Outer Shell | Color-coated steel |
| Heating | Stainless finned-tube electric heaters |
| Humidification | Stainless-steel sheathed steam generator |
| Airflow Design | Ceiling-mounted low-velocity discharge for high uniformity and minimal sample disturbance |
| Safety | Overload protection, compressor overheat/overcurrent/overpressure protection, dry-run and low-water alarms, power failure memory |
| Controller | Large LED-based multi-function programmable controller |
| Standard Port | One φ50 mm test port |
| Lighting | Explosion-proof interior lamp |
| Power Supply | AC 3-phase 5-wire 380 V / 50 Hz |
| Compliance | GB/T 5170.2–1996, GB/T 10592–1993, GB/T 2423.2–2008 (IEC 60068-2-2), GJB 150.3–2009, GJB 150.4–2009, GJB 360B–2009 |