GeneScience
Filter
Showing all 12 results
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | A10 MINI |
| Incubation Temperature Range | +3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | Ambient to 85% RH |
| Final Vacuum Pressure | < 50 mbar |
| Max Gas Injection Pressure | 1050 mbar |
| Gas Flow Rate (50 Hz) | 0.9 m³/h |
| External Dimensions | 14.5 × 23.5 × 28 cm |
| Net Weight | 5 kg |
| Chamber Volume | 3.5 L |
| Power Supply | 220 V, 50 Hz |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | A20 |
| Temperature Control Range | Ambient to 45 °C (optional temperature module) |
| Humidity Control Range | Ambient to 45 °C (optional temperature module) |
| Final Chamber Pressure | <50 mbar |
| Max Gas Input Pressure | 1 bar |
| Gas Flow Rate | 0.9 m³/h |
| Available Culture Volumes | 2.5 L, 3.5 L, 20 L, or 30 L (user-selectable) |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | A30 |
| Temperature Control Range | Ambient to 45 °C (optional temperature control module) |
| Humidity Control Range | Ambient to 45 °C (optional temperature control module) |
| Final Chamber Pressure | <50 mbar |
| Max Gas Injection Pressure | 1 bar |
| Gas Flow Rate | 0.9 m³/h |
| Available Culture Volumes | 2.5 L, 3.5 L, 20 L, or 30 L |
| Integrated Vacuum Pump | Yes |
| Sealing Interface | Quick-connect bayonet coupling |
| Chamber Material | High-gloss, impact-resistant, temperature-stable polyester |
| Optical Clarity | Fully transparent chamber body and lid |
| Programmable O₂ Setpoints | User-defined (0.1–10% O₂) with multi-stage gas purge logic |
| Process Reproducibility | Six-tier QC protocol with full audit trail logging |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AG300 |
| Temperature Range | Ambient +3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Control System | PID-based Digital Thermostat |
| Humidity Control | Automatic, Integrated Humidity Management System |
| Chamber Construction | 10 mm Acrylic Walls |
| Gas Configuration | Single-Gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-Gas (N₂ + Mixed Gas) |
| Gas Consumption | ~10 m³ lasts ~24 weeks (single-gas mode), ~33 weeks (dual-gas mode) |
| O₂ Detection Limit | <5 ppm (via Palladium Catalyst) |
| Anaerobic/Microaerophilic Mode | 0–10% O₂ programmable |
| Working Volume | 750 × 620 × 500 mm (W×D×H) |
| External Dimensions | 840 × 700 × 720 mm (W×D×H) |
| Weight | ~70 kg |
| Safety Features | Low-pressure alarm, over-temperature cutoff, dry泄压 valve, lift-off lid design |
| Optional Accessories | Anaerobic indicator pump, top-mounted fluorescent lamp kit, single-plate transfer port, rigid cuff system |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | AG300 Plus |
| Incubation Temperature Range | +3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Humidity Range | Ambient to 85% RH |
| O₂ Control Range | 0.0–20.9% (±0.1% accuracy) |
| CO₂ Control Range | 0.0–30.0% (±0.1% accuracy) |
| Operating Chamber Dimensions | 750 × 620 × 500 mm (L×W×H) |
| Transfer Lock Capacity | 20 × 90 mm Petri dishes |
| Maximum Culture Capacity | 400 × 90 mm Petri dishes or 70 × 250 mL Erlenmeyer flasks |
| Gas Supply | N₂, CO₂, compressed air, and pre-mixed anaerobic gas (e.g., 85% N₂ / 10% H₂ / 5% CO₂) |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | AG400plus |
| Incubation Temperature Range | Ambient +3°C to 52°C |
| Temperature Uniformity & Stability | ±0.3°C (PID-controlled) |
| Humidity Control | Up to <90% RH |
| Chamber Capacity | 400 × 90 mm Petri Dishes (operational mode), 500 × 90 mm Dishes (pure culture mode), 80 × 250 mL Erlenmeyer Flasks |
| Operating Chamber Dimensions | 770 × 680 × 610 mm (L×W×H) |
| External Dimensions | 860 × 760 × 830 mm (L×W×H) |
| Weight | ~85 kg |
| Gas Supply Options | Single-gas (10% H₂ + 10% CO₂ + 80% N₂) or Dual-gas (N₂ + premixed anaerobic gas) |
| Gas Consumption | ~10 m³ lasts ~30 weeks (dual-gas), ~22 weeks (single-gas) |
| O₂ Detection Limit | <5 ppm (Pd catalyst, 4-year service life) |
| Oxygen Control Range | 0–10% (anaerobic to microaerophilic) |
| Humidity Management | Automated digital humidity control |
| Access Modes | Airlock transfer (20 plates/batch) or seal-and-reseal rapid transfer (<10 s recovery) |
| Safety Features | Low-pressure alarm, over-temperature cutoff, leak detection with time-stamped logging, dry-type pressure relief valve |
| Ergonomics | Lift-off acrylic lid (10 mm thickness), bare-hand operation compatible, foot-switch vacuum/N₂ control, integrated power outlets |
| Optional | Anaerobic indicator pump, top-mounted fluorescent lighting module |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | Anaero Mark |
| Temperature Range | Up to 100°C |
| Temperature Uniformity & Stability | ±0.3°C at 37°C (typical), validated across full operating range |
| Humidity Control | Ambient humidity-dependent, optimized for operation at 18–28°C ambient |
| Gas Interface | 8 total ports (3 gas cylinder inputs, 4 incubation chamber outputs, 1 spare) |
| Chamber Volumes | 3.5 L / 7 L / 10 L / 20 L (user-selectable, modular) |
| Gas Exchange Speed | <2 min for microaerophilic |
| Catalyst | Palladium-coated hydrogen catalyst, regenerable in situ |
| Compliance | Designed to support GLP/GMP workflows with optional audit-trail-capable data logging and 21 CFR Part 11–compliant software modules |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | Anaerobox IV |
| Temperature Range | Ambient +5°C to 75°C |
| Temperature Uniformity & Stability | ±0.5°C |
| Humidity Control Range | Ambient +5°C to 75°C |
| Chamber Volume | 4 × 5.5 L (each chamber: 18 × 18 × 18 cm) |
| Operating Pressure | 1.5 bar |
| Gas Flow Rate | 0.9 m³/h |
| Anaerobic Generation Time | <3 minutes |
| Vacuum Pump Type | Oil-free diaphragm pump |
| Dimensions (W×D×H) | 140 × 92 × 77 cm |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E200 |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Temperature Control Range | Ambient +3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Temperature Stability | ±0.1°C |
| Humidity Control Range | Ambient RH to 85% RH |
| Transfer Lock Cycle Time | ≤15 s |
| Internal Working Volume | ≥140 L |
| O₂ Reduction Capability | <5 ppm (via Pd-catalyzed H₂/N₂/CO₂ system) |
| Gas Supply Options | Single-gas (10% H₂ / 10% CO₂ / 80% N₂) or Dual-gas (N₂ + premixed gas) |
| Gas Consumption | ~0.38 m³/week (dual-gas mode) |
| Operating O₂ Range | 0–10% (anaerobic to microaerophilic) |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | E200plus |
| Temperature Range | Ambient +3°C to 52°C |
| Temperature Uniformity | ±0.3°C |
| Temperature Accuracy | ±0.1°C |
| Humidity Range | Ambient RH to 85% RH |
| O₂ Control Range | <5 ppm (anaerobic) or 0–25% (hypoxic), resolution 0.1% |
| CO₂ Control Range | 0–20%, resolution 0.1% |
| Transfer Lock Cycle Time | ≤15 s |
| Internal Volume | ≥130 L |
| Culture Capacity | Up to 400 × 90 mm Petri dishes |
| Gas Mixing System | Integrated touchscreen-controlled tri-gas (N₂/CO₂/Air) mixer with 6-stage programmable cycling |
| Data Logging | USB-exportable, 30-day continuous recording of O₂, CO₂, temperature, humidity, and gas inlet events |
| Catalyst Lifespan | ≥4 years (palladium-based, non-regenerative) |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | E500G |
| Price Range | USD $13,500 – $68,000 (FOB) |
| Temperature Control Range | Ambient +3°C to 52°C |
| Temperature Uniformity & Stability | ±0.1°C |
| Humidity Range | Up to 90% RH (with optional ultrasonic humidification) |
| Brand | GeneScience |
|---|---|
| Origin | USA |
| Model | E800 |
| Temperature Range | +3°C to 52°C |
| Temperature Uniformity & Stability | ±0.3°C |
| Humidity Control Range | Ambient to 90% RH |
| O₂ Control (Anaerobic Mode) | <50 ppm |
| O₂ Control (Microaerophilic Mode) | 0.1–20.0% (0.1% increments) |
| CO₂ Control Range | 0.1–20.0% (0.1% increments) |
| Internal Chamber Capacity | 1200 × 90 mm Petri Dishes |
| Transfer Lock Volume | 20 L (60 × 90 mm plates per cycle) |
| HEPA Filtration | U16 Class, 99.99995% @ 0.12 µm |
| Data Logging | USB-based, 30-day continuous recording of O₂, temperature, humidity, and gas flow events |