| [Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-2001-A Series |
| Instrument Type | Fast Low-Pressure Liquid Chromatograph |
| Max Operating Pressure | 3 MPa |
| Detection Wavelengths | 260 nm, 280 nm (optional: 310 nm, 405 nm) |
| Flow Rate Range | 0.5–900 mL/h (dual-pump configuration) |
| Fraction Collection | 100 tubes × 12 mL capacity |
| Timer Range | 1 s – 199 h 59 min 59 s |
| Drop Counting | 1–9999 drops |
| Peak Trigger Range | 0–100 mV / 0–250 mV |
| Gradient Capacity | 1000 mL (with TH-500A mixer) |
| Column Compatibility | GE-compatible interfaces (1.0×50 cm, 1.0×70 cm, 2.6×50 cm columns included)] |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | 2001-D-III |
| Instrument Type | Low-Pressure Liquid Chromatograph (LPLC) |
| Detection Wavelengths | 260 nm & 280 nm (standard), optional 310 nm & 405 nm |
| UV Light Source | LED cold light source (lifetime >50,000 h) |
| Flow Rate Range | 2 × (0.5–900) mL/h |
| Pump Speed Control | 0–65 rpm |
| Gradient Volume Capacity | 1000 mL |
| Fraction Collection | 100 tubes × up to 12 mL/tube |
| Tube Programming | User-defined start number, 1–9999 drops or 0–100 mV peak threshold |
| Timing Range | 1 s – 199 h 59 min 59 s |
| Display | 10.1-inch high-definition blue-membrane LCD |
| Column Compatibility | GE-standard fittings (1.0×40 cm, 1.6×50 cm, 2.6×60 cm |
| Integrated Modules | JP-3001 dual-beam nucleic acid/protein detector, TH-500A gradient mixer, DBS-100 fraction collector, HL-2S constant-flow peristaltic pump |
| Software | Real-time acquisition and display of time, UV absorbance, gradient profile, temperature, conductivity, and tube index |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-BL100 |
| Instrument Type | Benchtop |
| Wavelength | 470 nm (Blue LED) |
| Viewing Area | 190 × 112 mm |
| Filter Material | Amber Acrylic with Metal Frame |
| Filter Tilt Angle | 0–145° Adjustable |
| LED Lifetime | >60,000 h |
| Power Supply | AC 220 V, 50/60 Hz |
| DC Output | 12 V, 2 A |
| Dimensions (L×W×H) | 220 × 220 × 35 mm |
| Weight | 1 kg |
| Compatible Stains | GeneGreen, GelRed, GelGreen, SYBR Green I, SYBR Safe, GoldView, SYBR Gold, SYPRO Ruby, SYPRO Orange, SYPRO Tangerine, eGFP, Cy2, FITC, Ethidium Bromide (EB) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K3300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65,535 grayscale levels) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4, 6×6, 8×8 |
| Detection Sensitivity | ≥0.02 ng Protein |
| Signal-to-Noise Ratio | 56 dB |
| Lens Aperture | f/0.95 Fixed Focus Lens |
| CCD Sensor | Sony IMX533CLK-D, 4/3″ format |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Quantum Efficiency | >75% |
| Pixel Size | 5.4 µm × 5.4 µm |
| White Light Transilluminator | Uniform top-mounted LED source |
| Dual Imaging Area | 9.5 × 9.5 cm and 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-K3600 |
| Instrument Type | Chemiluminescent Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | >4.8 OD |
| CCD Sensor Size | 4/3" |
| Detection Sensitivity | Protein ≥0.02 ng, DNA ≥0.05 ng (EB-stained dsDNA ≤20 pg) |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens Aperture | f/0.95 Fixed Focus Lens |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Pixel Binning Options | 1×1 to 8×8 |
| White Light Transilluminator | Uniform Top-Illumination Panel |
| UV Transilluminator | 300 nm (transmission), optional 254/365 nm (reflection) |
| UV Tray Size | 200 × 200 mm |
| Filter Wheel | 5-position motorized (optional 10-position) |
| Standard Emission Filter | 590 nm |
| Dimensions (W×D×H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K900 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65535 grayscale) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4, 6×6, 8×8 |
| Detection Sensitivity | <20 pg double-stranded DNA stained with ethidium bromide |
| Signal-to-Noise Ratio | ≥56 dB |
| Lens Aperture | F/0.95 fixed-focus lens |
| CCD Sensor | Sony IMX533CLK-D, 4/3″ format |
| Cooling Temperature | −45°C (ΔT ≈ −65°C vs ambient) |
| Pixel Size | 5.4 µm × 5.4 µm |
| Quantum Efficiency | >75% |
| Dark Current | <0.0005 e⁻/pixel/s |
| Transmission UV Source | 302 nm (standard), optional 254 nm / 365 nm reflectance UV |
| White Light Transilluminator | Integrated drawer-style uniform panel (200 × 200 mm) |
| Excitation Light Sources | UV transillumination (302 nm), optional UV reflectance (254/365 nm), blue/red/green LED fluorescence modules |
| Filter Wheel | Motorized 5-position (standard), optional 10-position |
| Imaging Area | Dual-stage—9.5 × 9.5 cm and 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio1000 |
| Spectral Bandwidth | 1.0, 0.5, 0.1, 0.05, 0.02 mm (auto-switching) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 185–910 nm |
| Cuvette Absorbance Range | 0–4 A |
| Sample Volume | 0.2–2.0 µL |
| Optical Path Lengths | 0.02–1.0 mm (motorized auto-adjustment) |
| Light Source | Xenon flash lamp (≥10⁹ flashes, ~10-year operational life) |
| Detector | 3648-pixel linear CCD array |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.002 A |
| OD₆₀₀ Mode | 600 ± 8 nm |
| Measurement Time | ≤5 s per sample |
| dsDNA Quantitation Range | 0–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Data Export | USB port, microSD slot |
| Optional fluorescence module (Ex | 460 nm, Em: 525 nm) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio1000 |
| Wavelength Accuracy | ±1 nm |
| Wavelength Range | 185–910 nm |
| Cuvette Mode (OD600) | 600 ± 8 nm |
| Sample Volume | 0–2.0 µL |
| Optical Path Lengths | 1.0 / 0.5 / 0.1 / 0.05 / 0.02 mm (auto-switching) |
| Light Source | Xenon flash lamp (≥10 yr lifetime) |
| Detector | 3648-pixel linear CCD array |
| Wavelength Resolution | ≤3 nm (FWHM at Hg 546 nm) |
| Absorbance Accuracy | ±1% (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.002 A |
| Absorbance Range (10-mm equivalent) | 0–780 A |
| OD600 Range | 0–4 A |
| Measurement Time | ≤5 s |
| dsDNA Quantification Range | 0–38,880 ng/µL |
| BSA Protein Range | 0.06–820 mg/mL |
| Data Export | USB port, SD-RAM card |
| Optional fluorescence module (Ex | 460 nm, Em: 525 nm) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio3009 |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Isocratic & Step Gradient |
| UV Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 3 bar |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% (with temperature compensation) |
| Solvent Compatibility | Aqueous buffers, common chromatographic mobile phases, and biocompatible solutions used in protein purification |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Model | JP-Keebio600 |
| Detection Method | Absorbance Photometry |
| Wavelength | 600 nm |
| Wavelength Accuracy | ±4.0 nm |
| Spectral Bandwidth | 8 nm |
| Absorbance Range | −0.3 to 3.0 A |
| Absorbance Accuracy | ±0.005 A (0–0.5 A), ±0.01 A (0.5–1.0 A) |
| Absorbance Repeatability | 0.002 A |
| Sample Volume | ≥200 µL |
| Light Source | Long-life LED (Cold White) |
| Detector | Silicon Photodiode |
| Display | 7-inch Color Touchscreen (1024 × 600) |
| Data Storage | Internal (128 MB) + USB/SD Card Export |
| Connectivity | USB-B |
| Power Supply | AC 100–240 V, 50/60 Hz or DC 12 V / 3 A |
| Dimensions (W×D×H) | 290 × 260 × 100 mm |
| Weight | 2.15 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | JP-KeebioFC |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mechanism | Suspended X-Y Robotic Movement |
| Display | 8.5-inch HD Touchscreen |
| Tube Capacity Options | 100 × 12 mL (standard), 16 × 100 mL (optional), 36 × 50 mL (optional), 169 × 5 mL (optional) |
| Timing Range | 1 s – 999 h 59 min 59 s |
| Drop Counting Range | 1–9999 drops |
| Peak Threshold Range | 1–200 mV |
| Programmable Segments | 1–10 segments |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 385 × 390 × 310 mm |
| Weight | 14 kg |
| Continuous Operation Time | >200 hours |
| Data Retention (Power Loss) | Up to 10 years |
| Valve Actuation | 12 V DC Solenoid |
| Tube Tray Design | Modular Square Rack with Integrated Waste Channel |
| Corrosion Resistance | Compatible with aqueous and common organic solvents (e.g., methanol, acetonitrile, chloroform, ethyl acetate) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-KeebioGO |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Types | Isocratic, Linear, and Step Gradients |
| Flow Rate Range | 0.001–25 mL/min |
| Flow Rate Accuracy | ±1.2% |
| UV Detection Range | –6 to +6 AU |
| Linearity | ±1.5% (0–2 AU) |
| Maximum System Pressure | 0–10 MPa (1500 psi) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Accuracy | ±2% with temperature compensation |
| pH Range | 0–14 (measurable range 2–12) |
| Accuracy | ±0.1 with temperature compensation |
| Temperature Sensor Range | 0–100 °C |
| Accuracy | ±1 °C |
| Detector Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| Wavelength Accuracy | ±1 nm |
| Repeatability | ±0.1 nm |
| Sample Cell Volume | 10 µL |
| Bubble Sensors | Installed at A/B inlets and sample inlet |
| Injection Valve | 3-position, 7-port, software-controllable, supporting Load/Inject/Waste modes |
| Fraction Collection Compatibility | JP-KeebioFC with configurable rack support |
| Data Export Format | Native Excel (.xlsx) |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 20 kg |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-KeebioStart |
| Price Range | USD 4,200 – 7,000 (FOB Shanghai) |
| Purification Principle | Ion Exchange Chromatography (IEX) |
| Gradient Type | Linear Gradient |
| Flow Rate Range | 0.1–10 mL/min |
| Flow Accuracy | ±1.2% |
| UV Detection Range | −6 to +6 AU (Linearity: ±1.5% within 0–2 AU) |
| Maximum Pressure | 3 MPa (30 bar) |
| Conductivity Range | 0.001–400.00 mS/cm |
| Conductivity Accuracy | ±2% |
| Temperature Detection Range | 0–100 °C (Accuracy: ±1 °C) |
| UV Wavelengths | 260 nm, 280 nm, 295 nm, 310 nm |
| UV Light Source | LED (Cold Light) |
| Wavelength Accuracy | ±1 nm |
| Sample Cell Volume | 10 µL |
| Mixer Volume | 200 µL (Static) |
| Fraction Collection | Optional JP-blupadFC collector with XY-axis positioning, peak-triggered collection (AU threshold, slope, conductivity), full-collection, and manual modes |
| Software | JP-blupad Chromatography Workstation (Registered Copyright No. 2019SR0680657) |
| Certifications | CN Utility Model Patent ZL201920802201.1, CN Design Patent ZL202130391697.0, CN Invention Patent ZL202110687106.3 |
| Operating Temperature | 4–40 °C |
| Dimensions (W×D×H) | 360 × 380 × 470 mm |
| Weight | 11 kg |
| Power Supply | 220 VAC |
| Brand | Jiapeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JP-UV1 |
| Instrument Type | Preparative Thin-Layer Chromatography (TLC) UV Visualization System |
| Operation Mode | Manual |
| Measurement Modes | Reflectance Absorption, Transmittance Absorption |
| Wavelengths | 254 nm, 365 nm (reflectance) |
| UV Light Source | Low-pressure mercury vapor lamps (8 W × 10) + white LED array |
| Imaging Wavelengths | 254 nm, 365 nm, visible white light |
| Viewing Area | 260 × 210 mm |
| UV Intensity at 20 cm | ≥20 µW/cm² (per JJF 1936–2021) |
| Optional UV Radiometer | 0–1000 µW/cm² range |
| Safety Features | >99% UV-blocking viewing window, dual side access ports |
| Dimensions (L×W×H) | 440 × 338 × 270 mm |
| Weight | 5.3 kg |
| Compliance | JJF 1936–2021 (National Verification Regulation for UV Analyzers), registered utility models ZL2012205175136 & ZL201920792756.2 |